{"contenttype":"article","language":"en","availableLanguages":"de,en,es,fr,it","rcn":"80932","id":"80932-rebuilding-indoor-air-quality-standards","title":"Rebuilding indoor air quality standards","teaser":"With the realisation that most people spend more time indoors than anywhere else, the importance of indoor air quality has become one of international focus. Initial discoveries concerning ailments such as sick building syndrome that affect both human health and productivity lead to even greater research initiatives. The current investigation seeks to establish the correlating data between how office refurbishment affects indoor air quality.","body":"\u003Csection\u003E\u003CsectionBody\u003EBecause of the growing trend in Europe to refurbish buildings rather than build new ones, an EC funded project undertook studies relating to how refurbishment affects indoor air quality. The study resulted in the development of protocols and supporting Management Information Systems to assist in controlling the effects refurbishing has on indoor air quality.\n\nThe protocol\u0027s components included three developments, a database of pollutants, a methodology for building diagnostics (including IAQ surveys on existing structures) and a specification system for IAQ monitoring and evaluation. The database includes such factors as pollutants from refurbishment materials and methods as well as their respective threshold limit values (TLV). These values determine the maximum limit of pollutant chemicals that can be found in an environment in order not to compromise human health.\n\nThe diagnostic element, both pre and during refurbishment provide details on specifications and measure to control pollutants through treating materials at source. It also includes such integral factors as ventilation and air conditioning systems, including a model to estimate pollution load and rate of decay during and after material application.\n\nOverall, the protocol provides much needed information to bring to light just how renovation and refurbishing does affect the environment and human health. The research is entering further development but support to establish a code of practice and integration of the protocol into total quality management practices is being sought.\u003C\/sectionBody\u003E\u003C\/section\u003E","contentCreationDate":"2005-09-18 17:48:59","contentUpdateDate":"2005-09-18 17:48:59","lastUpdateDate":"2021-10-28 19:30:14","archivedDate":"2024-06-10 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"indust","title":"Industrial Technologies","displayCode":"\/Industrial Technologies","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"brief","title":"Result in Brief","description":"Article: Classic and enhanced","displayCode":"\/Result in Brief","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"22784","id":"BRE20576","teaser":"\nThe research results comprises a Refurbishment Protocol and supporting Information system for IAQ assurance in refurbishment work, on a CD ROM. Components of the Protocol include:\n\n- A Data Base on Pollutants from Refurbishment Materials and Process and their TLVs;\n- A Method...","title":"PROTOCOL AND MANAGEMENT INFORMATION SYSTEM FOR INDOOR AIR QUALITY ASSURANCE IN THE REFURBISHMENT OF OFFICE BUILDINGS","archivedDate":"2024-04-19 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/47\/303","title":"databases","displayCode":"\/natural sciences\/computer and information sciences\/databases","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/75\/471","title":"thermodynamic engineering","displayCode":"\/engineering and technology\/mechanical engineering\/thermodynamic engineering","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/29\/91\/521\/1299\/1757","title":"productivity","displayCode":"\/social sciences\/economics and business\/economics\/production economics\/productivity","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/67\/39381296","title":"air pollution engineering","displayCode":"\/engineering and technology\/environmental engineering\/air pollution engineering","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/45\/277\/829","title":"pollution","displayCode":"\/natural sciences\/earth and related environmental sciences\/environmental sciences\/pollution","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"CSC","title":"Cost-sharing contracts","displayCode":"\/Cost-sharing contracts","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"undefined","title":"Undefined","description":"Legacy content transferred to CORDIS - no documentation","displayCode":"\/Undefined","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"de,en,es,fr,it","rcn":"198","code":"FP3-BRITE\/EURAM 2","frameworkProgramme":"FP3","pga":"FP3-BRITE\/EURAM 2","title":"Specific programme (EEC) of research and technological development in the field of industrial and materials technologies, 1990-1994","shortTitle":"Industrial and materials technologies","parent":{"rcn":"1005","code":"FP3"},"archivedDate":"2023-03-27 11:33:43","relations":{"categories":[{"language":"en","code":"legalbasis","title":"Legal Basis","description":"Programme: Legal basis for research funding","displayCode":"\/Legal Basis","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"undefined","type":"relatedLegalBasis"}},{"availableLanguages":"en","rcn":"663641","code":"2.3.3","frameworkProgramme":"FP3","title":"Human factors in engineering and manufacturing management","parent":{"rcn":"663638\/663629\/663607\/198\/1005","code":"2.3\/2\/0\/FP3-BRITE\/EURAM 2\/FP3"},"archivedDate":"2023-03-27 11:33:43","relations":{"categories":[{"language":"en","code":"topic","title":"Topic","description":"Programme: Part of the Commission work programme implementing legal basis","displayCode":"\/Topic","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"undefined","type":"relatedTopic"}}]},"contenttype":"project","attributes":{"source":"editorial","type":"relatedProject"}},{"availableLanguages":"en","rcn":"19884","title":"Office building refurbishment and indoor air quality","teaser":"The strong link between refurbishment and indoor air quality (IAQ) has been researched and a Protocol and supporting Management Information System have been developed to control IAQ problems in refurbishment work. The technical work comprised of three inter-related tasks. The ...","contentUpdateDate":"2001-08-09 00:02:53","archivedDate":"2024-06-22 00:00:00","relations":{"categories":[{"language":"en","code":"exploitable","title":"Exploitable Result","description":"Result: main interesting result, which has been selected and prioritized due to its high potential to be \u0022exploited\u0022","displayCode":"\/Exploitable Result","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"undefined","title":"Undefined","description":"Legacy content transferred to CORDIS - no documentation","displayCode":"\/Undefined","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"rcn":"22784","id":"BRE20576","title":"PROTOCOL AND MANAGEMENT INFORMATION SYSTEM FOR INDOOR AIR QUALITY ASSURANCE IN THE REFURBISHMENT OF OFFICE BUILDINGS","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/47\/303","title":"databases","displayCode":"\/natural sciences\/computer and information sciences\/databases","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/75\/471","title":"thermodynamic engineering","displayCode":"\/engineering and technology\/mechanical engineering\/thermodynamic engineering","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/29\/91\/521\/1299\/1757","title":"productivity","displayCode":"\/social sciences\/economics and business\/economics\/production economics\/productivity","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/67\/39381296","title":"air pollution engineering","displayCode":"\/engineering and technology\/environmental engineering\/air pollution engineering","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/45\/277\/829","title":"pollution","displayCode":"\/natural sciences\/earth and related environmental sciences\/environmental sciences\/pollution","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"CSC","title":"Cost-sharing contracts","displayCode":"\/Cost-sharing contracts","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"undefined","title":"Undefined","description":"Legacy content transferred to CORDIS - no documentation","displayCode":"\/Undefined","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"project","attributes":{"source":"undefined","type":"relatedProject"}}]},"contenttype":"result","attributes":{"source":"editorial","type":"relatedResult"}},{"language":"en","availableLanguages":"en,any","uri":"\/docs\/results\/images\/2005-09\/19884.jpg","mimetype":"image\/jpeg","size":"0","copyright":"\u00a9 Photodisc","contenttype":"webItem","attributes":{"represents":"article","source":"editorial","type":"relatedImage"}}],"regions":[{"name":"Netherlands","rcn":"391547432","nutsCode":"NL","euCode":"NL","isoCode":"NL","attributes":{"source":"editorial","type":"relatedRegion"}}]},"modelVersion":"132","icaVersion":"20.0.0-48f81e07"}