{"contenttype":"article","language":"en","availableLanguages":"de,en,es,fr,it","rcn":"81502","id":"81502-disposable-sensor-for-organ-transplantation","title":"Disposable sensor for organ transplantation","teaser":"The ever-increasing need for organs for transplantation can only be covered by an increase in the number of the donors. However, the success rate of transplantations of current organ supplies can be improved through organ viability monitoring.","body":"\u003Csection\u003E\u003CsectionBody\u003EAn organ due for transplantation has a time fixed viability, designed on a worst-case directive. However, this often leads to the discarding of viable organs, when the expiration time has expired. Continuous monitoring of the organ would not only allow the timely assurance of its viability but also the evaluation of its behavior during preservation, transport and initial postoperative period.\n\nIn the context of the European project, MICROTRANS, a new and reliable multi-sensor micro-probe, based on silicon, has been developed, allowing the constant monitoring of the organ due for transplantation. The use of microelectronic technologies in the fabrication of micro probes provides high reliability and low costs, while at the same time the monitoring of organ viability is attained with respect to the need for ideal temperature and pathogen isolation of the organ during transport.\n\nThe micro-probe includes sensors of temperature, pH, potassium and impedance, which comprise essential parameters for the evaluation of the physiological status of living organs. Its conformance with the medical devices directives on electrical safety and biocompatibility allowed use of the micro-probe in experimental and clinical practice.\n\nThe validation of the system was performed through a custom-made instrumentation system, developed under MICROTRANS, for use in both clinical environment and in-vivo experimentation. The system has a modular architecture, hosting different modules for each parameter of interest, offering flexibility for the variety of sensor types and technologies that may be used. The software for the processing (filtering and calibration), control, display and store the measured data sent from the different modules has been developed on the basis of Lab View software platform.\n\nDiverse experimental works, both in vitro and in vivo, have been carried out to verify the behavior of the system, demonstrating promising results. The micro-sensor electronic system based on silicon for multiple-parameter in vivo measurement open new trails in the in-situ monitoring of grafts, thus expanding the number of available grafts and their possible destinies.\u003C\/sectionBody\u003E\u003C\/section\u003E","contentCreationDate":"2005-09-18 17:50:21","contentUpdateDate":"2005-09-18 17:50:21","lastUpdateDate":"2019-09-05 10:30:59","archivedDate":"2024-06-10 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"health","title":"Health","displayCode":"\/Health","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"brief","title":"Result in Brief","description":"Article: Classic and enhanced","displayCode":"\/Result in Brief","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"54497","id":"IST-1999-13047","acronym":"MICROTRANS","teaser":"This proposal seeks to provide the medical community with an innovative way for reliable monitoring of organs during transplantation. The monitoring, done using a purposely developed microsystem, would provide means for continuous evaluation of organ feasibility both during tr...","title":"Microprobe multi-sensor for graft viability monitoring during organ preservation and transplantation","archivedDate":"2024-05-27 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/71\/447","title":"biosensing","displayCode":"\/engineering and technology\/environmental biotechnology\/biosensing","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/43\/259\/783","title":"microelectronics","displayCode":"\/natural sciences\/physical sciences\/electromagnetism and electronics\/microelectronics","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/53\/365\/71735538","title":"metalloids","displayCode":"\/natural sciences\/chemical sciences\/inorganic chemistry\/metalloids","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/21\/39\/237","title":"transplantation","displayCode":"\/medical and health sciences\/clinical medicine\/transplantation","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/59\/379","title":"microtechnology","displayCode":"\/engineering and technology\/other engineering and technologies\/microtechnology","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"CSC","title":"Cost-sharing contracts","displayCode":"\/Cost-sharing contracts","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"de,en,es,fr,it","rcn":"641","code":"FP5-IST","frameworkProgramme":"FP5","pga":"FP5-IST","title":"Programme for research, technological development and demonstration on a \u0022User-friendly information society, 1998-2002\u0022","shortTitle":"User-friendly information society","parent":{"rcn":"624","code":"FP5"},"archivedDate":"2023-03-27 11:33:43","relations":{"categories":[{"language":"en","code":"legalbasis","title":"Legal Basis","description":"Programme: Legal basis for research funding","displayCode":"\/Legal Basis","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedLegalBasis"}},{"availableLanguages":"en","rcn":"6000","code":"1.1.2.-4.7.3","frameworkProgramme":"FP5","title":"Microsystems","parent":{"rcn":"5997\/5973\/641\/624","code":"1.1.2.-4.7.\/1.1.2.-4.\/FP5-IST\/FP5"},"archivedDate":"2023-03-27 11:33:43","relations":{"categories":[{"language":"en","code":"topic","title":"Topic","description":"Programme: Part of the Commission work programme implementing legal basis","displayCode":"\/Topic","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedTopic"}}]},"contenttype":"project","attributes":{"source":"editorial","type":"relatedProject"}},{"availableLanguages":"en","rcn":"32022","title":"A electronic instrumentation to measure living tissue conditions","teaser":"Two kind of a measurement system have been developed, the first one to be used in clinical environment and the other one for in-vivo experimentation. Electronics for \u0022on line\u0022 sensor characterization have been also developed.\n\nDeveloped instrumentation allows it to display, to...","contentUpdateDate":"2004-02-03 00:00:00","archivedDate":"2024-06-20 00:00:00","relations":{"categories":[{"language":"en","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"id15","title":"Results of demonstration trials available","displayCode":"\/Results of demonstration trials available","attributes":{"classification":"resultDevelopmentStage","type":"relatedResultDevelopmentStage"}},{"language":"en","code":"eTip","title":"e-TIP","description":"FP5 reporting system (CORDIS application)","displayCode":"\/e-TIP","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"rcn":"54497","id":"IST-1999-13047","title":"Microprobe multi-sensor for graft viability monitoring during organ preservation and transplantation","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/71\/447","title":"biosensing","displayCode":"\/engineering and technology\/environmental biotechnology\/biosensing","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/43\/259\/783","title":"microelectronics","displayCode":"\/natural sciences\/physical sciences\/electromagnetism and electronics\/microelectronics","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/53\/365\/71735538","title":"metalloids","displayCode":"\/natural sciences\/chemical sciences\/inorganic chemistry\/metalloids","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/21\/39\/237","title":"transplantation","displayCode":"\/medical and health sciences\/clinical medicine\/transplantation","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/59\/379","title":"microtechnology","displayCode":"\/engineering and technology\/other engineering and technologies\/microtechnology","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"CSC","title":"Cost-sharing contracts","displayCode":"\/Cost-sharing contracts","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"project","attributes":{"source":"eTip","type":"relatedProject"}}]},"contenttype":"result","attributes":{"source":"editorial","type":"relatedResult"}},{"language":"en","availableLanguages":"en,any","uri":"\/docs\/results\/images\/2005-09\/32022.jpg","mimetype":"image\/jpeg","size":"0","copyright":"\u00a9 PhotoDisc","contenttype":"webItem","attributes":{"represents":"article","source":"editorial","type":"relatedImage"}}],"regions":[{"name":"Spain","rcn":"242387496","nutsCode":"ES","euCode":"ES","isoCode":"ES","attributes":{"source":"editorial","type":"relatedRegion"}}]},"modelVersion":"132","icaVersion":"20.0.0-48f81e07"}