{"contenttype":"article","language":"en","availableLanguages":"de,en,es,fr,it","rcn":"81631","id":"81631-reliable-and-quick-detection-of-antigens","title":"Reliable and quick detection of antigens","teaser":"Focusing on increasing the sensitivity, reliability and speediness of measurements performed by biosensors, a new nanostructured biochemical interface has been designed.","body":"\u003Csection\u003E\u003CsectionBody\u003EThe introduction of advanced biosensor technology has brought dramatic changes in the field of immunodiagnostics and testing. As an example, a newly developed biosensor measures the Prostate Specific Antigen (PSA) level in the blood for monitoring patients diagnosed with prostate cancer. \n\nOne of the key components of this biosensor is the surface linking layer, which comprises two-dimensional crystalline protein mono-layers (S-layers) coming from bacterial cell surfaces. The biological S-layers are isolated from bacterial walls and used for the development of nanobiotechnological products. \n\nAt the transducer surface, PSA specific camel antibody fragments (VHH) are bound to the S-layer protein in a well-controlled, highly organised way displaying increased stability and reproducibility. This innovative design constitutes a unique biological self-assembly system that shows advanced capabilities of re-crystallising on organic surfaces including silicon, glass or gold. \n\nFurthermore, this novelty has the potential to become a versatile and robust molecular construction kit for various biological-sensing applications. This is mainly due to the availability of a large variety of functional domains with a specified position and orientation. \n\nThe S-layer proteins can be smoothly integrated in the fabrication process of micro sensor technology in order to generate the overall micro-Total Analysis System (TAS) modules. For more information click: http:\/\/www.imec.be\/PAMELA\u003C\/sectionBody\u003E\u003C\/section\u003E","contentCreationDate":"2005-09-18 17:50:44","contentUpdateDate":"2005-09-18 17:50:44","lastUpdateDate":"2019-09-05 10:31:46","archivedDate":"2024-06-10 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"health","title":"Health","displayCode":"\/Health","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"brief","title":"Result in Brief","description":"Article: Classic and enhanced","displayCode":"\/Result in Brief","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"54502","id":"IST-1999-13478","acronym":"PAMELA","teaser":"The aim is a more efficient system for monitoring patients diagnosed with prostate cancer, by measurement of the Prostate Specific Antigen (PSA) level in the blood. It is foreseen that the new technology will have an overwhelming impact in related areas of immunodiagnostic tes...","title":"An integrated microbiosensor system for patient monitoring by measurement of extremely low analyte concentrations present in the blood","archivedDate":"2024-05-27 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/21\/39\/225\/1473","title":"prostate cancer","displayCode":"\/medical and health sciences\/clinical medicine\/oncology\/prostate cancer","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/43\/269\/811\/34823946","title":"microfluidics","displayCode":"\/natural sciences\/physical sciences\/classical mechanics\/fluid mechanics\/microfluidics","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/73\/453\/58525161\/66357197","title":"biosensors","displayCode":"\/engineering and technology\/electrical engineering, electronic engineering, information engineering\/electronic engineering\/sensors\/biosensors","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/59\/379\/16253769","title":"lab on a chip","displayCode":"\/engineering and technology\/other engineering and technologies\/microtechnology\/lab on a chip","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/63\/391","title":"coating and films","displayCode":"\/engineering and technology\/materials engineering\/coating and films","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"CSC","title":"Cost-sharing contracts","displayCode":"\/Cost-sharing contracts","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"de,en,es,fr,it","rcn":"641","code":"FP5-IST","frameworkProgramme":"FP5","pga":"FP5-IST","title":"Programme for research, technological development and demonstration on a \u0022User-friendly information society, 1998-2002\u0022","shortTitle":"User-friendly information society","parent":{"rcn":"624","code":"FP5"},"archivedDate":"2023-03-27 11:33:43","relations":{"categories":[{"language":"en","code":"legalbasis","title":"Legal Basis","description":"Programme: Legal basis for research funding","displayCode":"\/Legal Basis","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedLegalBasis"}},{"availableLanguages":"en","rcn":"6000","code":"1.1.2.-4.7.3","frameworkProgramme":"FP5","title":"Microsystems","parent":{"rcn":"5997\/5973\/641\/624","code":"1.1.2.-4.7.\/1.1.2.-4.\/FP5-IST\/FP5"},"archivedDate":"2023-03-27 11:33:43","relations":{"categories":[{"language":"en","code":"topic","title":"Topic","description":"Programme: Part of the Commission work programme implementing legal basis","displayCode":"\/Topic","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedTopic"}}]},"contenttype":"project","attributes":{"source":"editorial","type":"relatedProject"}},{"availableLanguages":"en","rcn":"32034","title":"Nanostructured S-layer technology","teaser":"A well controlled, nanostructured biochemical interface, which provides optimum conditions for sensitive, reliable, and fast detection of antigens (PSA) was a basic concept of the PAMELA sensor. The envisaged design consisted of S-layer proteins as a crystalline linking layer ...","contentUpdateDate":"2004-02-03 00:00:00","archivedDate":"2024-06-20 00:00:00","relations":{"categories":[{"language":"en","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"id17","title":"Scientific and\/or technical knowledge (basic research)","attributes":{"classification":"resultDevelopmentStage","type":"relatedResultDevelopmentStage"}},{"language":"en","code":"eTip","title":"e-TIP","description":"FP5 reporting system (CORDIS application)","displayCode":"\/e-TIP","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"rcn":"54502","id":"IST-1999-13478","title":"An integrated microbiosensor system for patient monitoring by measurement of extremely low analyte concentrations present in the blood","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/21\/39\/225\/1473","title":"prostate cancer","displayCode":"\/medical and health sciences\/clinical medicine\/oncology\/prostate cancer","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/43\/269\/811\/34823946","title":"microfluidics","displayCode":"\/natural sciences\/physical sciences\/classical mechanics\/fluid mechanics\/microfluidics","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/73\/453\/58525161\/66357197","title":"biosensors","displayCode":"\/engineering and technology\/electrical engineering, electronic engineering, information engineering\/electronic engineering\/sensors\/biosensors","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/59\/379\/16253769","title":"lab on a chip","displayCode":"\/engineering and technology\/other engineering and technologies\/microtechnology\/lab on a chip","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/63\/391","title":"coating and films","displayCode":"\/engineering and technology\/materials engineering\/coating and films","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"CSC","title":"Cost-sharing contracts","displayCode":"\/Cost-sharing contracts","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"project","attributes":{"source":"eTip","type":"relatedProject"}}]},"contenttype":"result","attributes":{"source":"editorial","type":"relatedResult"}},{"language":"en","availableLanguages":"en,any","uri":"\/docs\/results\/images\/2005-09\/32034.jpg","mimetype":"image\/jpeg","size":"0","copyright":"\u00a9 PhotoDisc","contenttype":"webItem","attributes":{"represents":"article","source":"editorial","type":"relatedImage"}}],"regions":[{"name":"Austria","rcn":"175540776","nutsCode":"AT","euCode":"AT","isoCode":"AT","attributes":{"source":"editorial","type":"relatedRegion"}}]},"modelVersion":"132","icaVersion":"20.0.0-48f81e07"}