{"contenttype":"article","language":"en","availableLanguages":"de,en,es,fr,it,pl","rcn":"86182","id":"86182-renewable-energy-from-existing-highrise-buildings","title":"Renewable energy from existing high-rise buildings","teaser":"When you think of renewable energy in the building sector, the image that usually comes to mind is that of domestic solar water heaters and photovoltaic (PV) systems used in the family home. However, these concepts must be applied to large buildings if renewable energy use is to significantly increase.","body":"\u003Csection\u003E\u003CsectionBody\u003EHigh-rise buildings have a small roof area compared to their floor area and the roof is often occupied with installations such as cooling towers. In addition, existing buildings usually have a higher energy demand than new ones. The solution to these challenges is to convert the facades of existing buildings into multifunctional elements for harvesting solar energy. A major increase in the number of solar energy components mounted on buildings or integrated into the structure of a building will help the EU achieve its goal of carbon dioxide (CO2) neutrality for the building stock by 2050.\n\nThe \u0027Resource and cost-effective integration of renewables in existing high-rise buildings\u0027 (COST-EFFECTIVE) project developed five new facade components and systems. Each system was customised according to the building under consideration, taking into consideration size, wind load and safety barrier function. The intention is that the facade components will be produced by local manufacturers on demand, thereby providing an opportunity for European manufacturers in the European market.\n\nConsortium members developed a glazing integrated transparent solar thermal collector and air-heating vacuum tube collectors for facade application. Project partners also developed an angle-selective transmittance building-integrated photovoltaic (BIPV) component. In addition, a facade-integrated natural ventilation system with heat recovery was created together with a solar-assisted decentralised heat pump system that used unglazed solar thermal collectors with plaster covering.\n\nResearchers also combined technical concepts and corresponding business models for the most important categories of existing high-rise buildings in Europe. The new business and cost models considered the whole life cycle of a building and incorporated the benefits from reduced running costs and greenhouse gas emissions. The consortium also demonstrated the practical feasibility of their work in two pilot buildings, one in Spain and the other in Slovenia.\n\nWork conducted by the COST-EFFECTIVE consortium will help increase the uptake of renewable technology for heating and cooling Europe\u0027s existing high-rise buildings and ensure that the 2050 CO2 neutrality target is met.\u003C\/sectionBody\u003E\u003C\/section\u003E","contentCreationDate":"2011-02-21 14:52:24","contentUpdateDate":"2011-02-21 14:52:24","lastUpdateDate":"2026-07-31 14:33:31","archivedDate":"2024-06-10 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"ener","title":"Energy","displayCode":"\/Energy","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"brief","title":"Result in Brief","description":"Article: Classic and enhanced","displayCode":"\/Result in Brief","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"de,en,es,fr,it,pl","rcn":"400706","id":"400706-innovative-modes-of-transport-where-would-we-be-without-cars","title":"Innovative modes of transport: where would we be without cars?","contentUpdateDate":"2011-07-01 00:00:01","archivedDate":"2024-05-29 00:00:00","relations":{"categories":[{"language":"en","code":"mag","title":"research*eu magazine","description":"Article: Both results and focus magazines","displayCode":"\/research*eu magazine","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl,any","uri":"\/docs\/article\/images\/2017-10\/400706.jpg","mimetype":"image\/jpeg","size":"0","contenttype":"webItem","attributes":{"represents":"magazineCover","source":"editorial","type":"relatedImage"}},{"language":"en","availableLanguages":"en","defaultLanguage":"en","title":"Download ePUB version","id":"87fda8bf-fc42-4164-801d-945e5fecb6a4_epub","physUrl":"https:\/\/op.europa.eu\/o\/opportal-service\/download-handler?identifier=87fda8bf-fc42-4164-801d-945e5fecb6a4\u0026format=EPUB\u0026language=en\u0026productionSystem=cellar","status":"legacy","contenttype":"webLink","attributes":{"represents":"article","source":"editorial","type":"formatEpub"}},{"language":"en","availableLanguages":"en","defaultLanguage":"en","title":"Download PDF version","id":"87fda8bf-fc42-4164-801d-945e5fecb6a4_pdf","physUrl":"https:\/\/op.europa.eu\/o\/opportal-service\/download-handler?identifier=87fda8bf-fc42-4164-801d-945e5fecb6a4\u0026format=PDF\u0026language=en\u0026productionSystem=cellar","status":"legacy","contenttype":"webLink","attributes":{"represents":"article","source":"editorial","type":"formatPdf"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","defaultLanguage":"en","title":"Order paper copy","id":"87fda8bf-fc42-4164-801d-945e5fecb6a4_print","physUrl":"https:\/\/op.europa.eu\/en\/publication-detail\/-\/publication\/87fda8bf-fc42-4164-801d-945e5fecb6a4\/","status":"legacy","contenttype":"webLink","attributes":{"represents":"article","source":"editorial","type":"orderPrint"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"isContainedIn"}},{"availableLanguages":"en","rcn":"89638","id":"212206","acronym":"COST-EFFECTIVE","teaser":"The use of renewable energy in the building sector is today dominated by the application of solar domestic hot water and PV systems in single-family houses. In order to significantly increase the use of renewable energy in the building sector, concepts have to be developed fo...","title":"Resource- and Cost-effective integration of renewables in existing high-rise buildings","archivedDate":"2024-06-18 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/63\/391","title":"coating and films","displayCode":"\/engineering and technology\/materials engineering\/coating and films","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/67\/425\/1171","title":"energy conversion","displayCode":"\/engineering and technology\/environmental engineering\/energy and fuels\/energy conversion","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/67\/425\/1169\/1685\/98939167","title":"photovoltaic","displayCode":"\/engineering and technology\/environmental engineering\/energy and fuels\/renewable energy\/solar energy\/photovoltaic","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"CP-IP","title":"Large-scale integrating project","displayCode":"\/Large-scale integrating project","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"de,en,es,fr,it,pl","rcn":"854","code":"FP7-NMP","frameworkProgramme":"FP7","pga":"FP7-NMP","title":"Specific Programme \u0022Cooperation\u0022: Nanosciences, Nanotechnologies, Materials and new Production Technologies","shortTitle":"Nanosciences, nanotechnologies, materials and new production technologies","parent":{"rcn":"846\/1401\/837","code":"FP7-COOPERATION\/EC\/FP7"},"archivedDate":"2024-06-12 00:00:00","relations":{"categories":[{"language":"en","code":"legalbasis","title":"Legal Basis","description":"Programme: Legal basis for research funding","displayCode":"\/Legal Basis","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedLegalBasis"}},{"availableLanguages":"en","rcn":"12003","code":"NMP-2007-4.0-5","frameworkProgramme":"FP7","title":"Resource Efficient and Clean Buildings","parent":{"rcn":"10348\/19513\/854\/846\/1401\/837","code":"NMP-4\/NMP\/FP7-NMP\/FP7-COOPERATION\/EC\/FP7"},"archivedDate":"2024-06-14 00:00:00","relations":{"categories":[{"language":"en","code":"topic","title":"Topic","description":"Programme: Part of the Commission work programme implementing legal basis","displayCode":"\/Topic","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedTopic"}}]},"contenttype":"project","attributes":{"source":"editorial","type":"relatedProject"}},{"availableLanguages":"en","rcn":"56956","title":"Final Report Summary - COST-EFFECTIVE (Resource and cost-effective integration of renewables in existing high-rise buildings)","teaser":"Recent studies by Fraunhofer ISE reliably prove that electricity and heat supply systems for Germany based completely on renewable energy sources would cause lower macroeconomic costs than the current energy system relying mainly on nuclear and fossil fuels. The total costs fo...","contentUpdateDate":"2013-06-12 00:02:53","archivedDate":"2024-06-23 00:00:00","relations":{"categories":[{"language":"en","code":"pubsum","title":"Report Summary","description":"Result: Publishable summary (FP7 SESAM) and Summary for publication (H2020 SyGMa)","displayCode":"\/Report Summary","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"sesam","title":"SESAM","description":"RTD FP7 reporting system (including FP6 Marie Curie)","displayCode":"\/SESAM","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"rcn":"89638","id":"212206","title":"Resource- and Cost-effective integration of renewables in existing high-rise buildings","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/63\/391","title":"coating and films","displayCode":"\/engineering and technology\/materials engineering\/coating and films","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/67\/425\/1171","title":"energy conversion","displayCode":"\/engineering and technology\/environmental engineering\/energy and fuels\/energy conversion","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/67\/425\/1169\/1685\/98939167","title":"photovoltaic","displayCode":"\/engineering and technology\/environmental engineering\/energy and fuels\/renewable energy\/solar energy\/photovoltaic","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"CP-IP","title":"Large-scale integrating project","displayCode":"\/Large-scale integrating project","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"project","attributes":{"source":"sesam","type":"relatedProject"}},{"language":"en","availableLanguages":"en,any","uri":"\/docs\/results\/212\/212206\/costeff-d0-1-4-final-publishable-summary-report-ise-no33-rev2013-02-28.pdf","title":"Final Report - COST-EFFECTIVE (Resource and cost-effective integration of renewables in existing high-rise buildings)","mimetype":"application\/pdf","size":"4274061","description":"This is the final publishable summary report for the COST-EFFECTIVE project. Funded under the European Commission (EC)\u0027s Seventh Framework Programme (FP7), COST-EFFECTIVE\u0027s main objective was to convert facades of existing high-rise buildings into multifunctional, energy gaining components. The report includes an executive summary covering the project context, objectives and the activities carried out. It goes on explaining in further detail the project concept and main aims and then analyses the tasks and the related outcomes which are classified in eight work packages. Finally, it covers the results\u0027 potential impact and also includes the project website and logo.","contenttype":"webItem","attributes":{"source":"undefined","type":"relatedResultAttachment"}}]},"contenttype":"result","attributes":{"source":"editorial","type":"relatedResult"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl,any","uri":"\/docs\/results\/images\/2011-02\/56956.jpg","mimetype":"image\/jpeg","size":"0","copyright":"\u00a9 Thinkstock","contenttype":"webItem","attributes":{"represents":"article","source":"editorial","type":"relatedImage"}}],"regions":[{"name":"Germany","rcn":"221940264","nutsCode":"DE","euCode":"DE","isoCode":"DE","attributes":{"source":"editorial","type":"relatedRegion"}}]},"modelVersion":"132","icaVersion":"20.0.0-48f81e07"}