{"contenttype":"article","language":"fr","availableLanguages":"de,en,es,fr,it,pl","rcn":"89896","id":"89896-groundshaking-research-for-europe","title":"Une recherche r\u00e9volutionnaire pour l\u0027Europe","teaser":"Pour tester des structures r\u00e9elles dans des conditions sismiques r\u00e9alistes, il faut disposer de beaucoup de place et de tr\u00e8s grandes tables \u00e0 secousses. L\u0027\u0027UE a financ\u00e9 un projet visant \u00e0 doter l\u0027\u0027Europe de sa propre installation de tests sismiques.","body":"\u003Csection\u003E\u003CsectionBody\u003EPour beaucoup de pays d\u00e9velopp\u00e9s, les tremblements de terre repr\u00e9sentent un risque majeur. Le nombre de victimes diminue, mais les co\u00fbts et les cons\u00e9quences augmentent. Le Japon et les \u00c9tats-Unis disposent d\u0027\u0027infrastructures de tests sismiques, mais l\u0027\u0027extrapolation des r\u00e9sultats en Europe et notamment en r\u00e9gion m\u00e9diterran\u00e9enne est difficile \u00e0 cause de la diff\u00e9rence de structure des constructions.\n\nL\u0027\u0027UE a besoin d\u0027\u0027une infrastructure d\u0027\u0027\u00e9tudes sismiques exp\u00e9rimentales convenant \u00e0 ses besoins, d\u0027\u0027une part pour maintenir la comp\u00e9titivit\u00e9 de l\u0027\u0027important secteur des services et conseils en g\u00e9nie civil, mais aussi pour mieux prot\u00e9ger ses propres infrastructures et ses citoyens. Le projet E-FAST (\u00abDesign study of a European facility for advanced seismic testing\u00bb) financ\u00e9 par l\u0027\u0027UE s\u0027\u0027est attaqu\u00e9 \u00e0 r\u00e9pondre \u00e0 ce besoin pressant. L\u0027\u0027objectif \u00e9tait d\u0027\u0027utiliser des tables \u00e0 secousses performantes et assez grandes pour \u00e9viter les erreurs r\u00e9sultant de l\u0027\u0027extrapolation des r\u00e9sultats.\n\nLa conception a port\u00e9 sur des tables \u00e0 secousses de 6 m\u00e8tres sur 6, capable de se d\u00e9placer selon les axes x, y et z, mais aussi en rotation. Chaque table peut supporter 100 tonnes et fonctionner ind\u00e9pendamment ou en liaison avec les autres, dans ce dernier cas de mani\u00e8re synchrone ou asynchrone. Une autre table, plus grande (11 x 11 m), ne se d\u00e9place qu\u0027\u0027horizontalement et peut supporter 500 tonnes.\n\nPour soutenir les tables \u00e0 secousses, le projet a int\u00e9gr\u00e9 \u00e0 la salle exp\u00e9rimentale une masse r\u00e9active, des pompes et des accumulateurs hydrauliques, et une solide dalle de plancher pos\u00e9e directement sur le sol. Cette dalle \u00e9vite les co\u00fbts et la complexit\u00e9 d\u0027\u0027ajouter des syst\u00e8mes pour isoler des vibrations. La structure r\u00e9active modulaire permet de combiner les tables et les actionneurs dans diverses configurations. Enfin, une vaste zone en ext\u00e9rieur est pr\u00e9vue pour construire les mod\u00e8les qui seront d\u00e9plac\u00e9s dans la salle d\u0027\u0027exp\u00e9riences via un pont roulant de grande capacit\u00e9. Les tests pr\u00e9liminaires d\u0027\u0027exp\u00e9rience et de mod\u00e9lisation du concept ont mis en avant d\u0027\u0027importantes consid\u00e9rations et capacit\u00e9s.\n\nLe projet E-FAST a pos\u00e9 les bases d\u0027\u0027une installation europ\u00e9enne sophistiqu\u00e9e pour les tests sismiques. Elle promet de r\u00e9duire la vuln\u00e9rabilit\u00e9 et de favoriser un d\u00e9veloppement \u00e9conomique durable en r\u00e9duisant les pertes en vies et en structures, et en am\u00e9liorant la comp\u00e9titivit\u00e9 technologique.\u003C\/sectionBody\u003E\u003C\/section\u003E","contentCreationDate":"2012-12-04 16:00:12","contentUpdateDate":"2012-12-04 16:00:12","lastUpdateDate":"2023-04-24 14:40:07","archivedDate":"2024-06-10 00:00:00","relations":{"categories":[{"language":"fr","availableLanguages":"de,en,es,fr,it,pl","code":"ener","title":"\u00c9nergie","displayCode":"\/\u00c9nergie","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"fr","availableLanguages":"de,en,es,fr,it,pl","code":"brief","title":"R\u00e9sultat en bref","description":"Article: classique et am\u00e9lior\u00e9","displayCode":"\/R\u00e9sultat en bref","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"fr","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"\u00c9ditorial CORDIS","description":"R\u00e9dig\u00e9 par CORDIS","displayCode":"\/\u00c9ditorial CORDIS","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"87830","id":"212109","acronym":"E-FAST","archivedDate":"2024-06-18 00:00:00","relations":{"categories":[{"language":"fr","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Projet","description":"Fiches d\u0027information du projet","displayCode":"\/Projet","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"fr","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/77\/473\/1255","title":"g\u00e9nie sismique","displayCode":"\/ing\u00e9nierie et technologie\/g\u00e9nie civil\/ing\u00e9nierie des structures\/g\u00e9nie sismique","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"fr","availableLanguages":"en","code":"CP","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"fr","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"Centrale de donn\u00e9es de la recherche RTD","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"de,en,es,fr,it,pl","rcn":"859","code":"FP7-INFRASTRUCTURES","frameworkProgramme":"FP7","pga":"FP7-INFRASTRUCTURES","title":"Programme sp\u00e9cifique \u0022Capacit\u00e9s\u0022: Infrastructures de recherche","shortTitle":"Infrastructures de recherche","parent":{"rcn":"847\/1401\/837","code":"FP7-CAPACITIES\/EC\/FP7"},"archivedDate":"2024-06-12 00:00:00","relations":{"categories":[{"language":"fr","code":"legalbasis","title":"Base juridique","description":"Programme: Base juridique pour le financement de la recherche","displayCode":"\/Base juridique","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"fr","code":"editorial","title":"\u00c9ditorial CORDIS","description":"R\u00e9dig\u00e9 par CORDIS","displayCode":"\/\u00c9ditorial CORDIS","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedLegalBasis"}},{"availableLanguages":"en","rcn":"11009","code":"INFRA-2007-2.1-01","frameworkProgramme":"FP7","parent":{"rcn":"10314\/10312\/11458\/859\/847\/1401\/837","code":"INFRASTR-2.1\/INFRA-2\/INFRA\/FP7-INFRASTRUCTURES\/FP7-CAPACITIES\/EC\/FP7"},"archivedDate":"2024-06-14 00:00:00","relations":{"categories":[{"language":"fr","code":"topic","title":"Th\u00e8me","description":"Programme: Partie du programme de travail de la Commission mettant en \u0153uvre la base juridique","displayCode":"\/Th\u00e8me","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"fr","code":"editorial","title":"\u00c9ditorial CORDIS","description":"R\u00e9dig\u00e9 par CORDIS","displayCode":"\/\u00c9ditorial CORDIS","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedTopic"}}]},"contenttype":"project","attributes":{"source":"editorial","type":"relatedProject"}},{"availableLanguages":"en","rcn":"54660","archivedDate":"2024-06-23 00:00:00","relations":{"categories":[{"language":"fr","code":"pubsum","title":"R\u00e9sum\u00e9 du rapport","description":"R\u00e9sultat: R\u00e9sum\u00e9 publiable (FP7 SESAM) et R\u00e9sum\u00e9 soumis \u00e0 la publication (H2020 SyGMa)","displayCode":"\/R\u00e9sum\u00e9 du rapport","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"fr","code":"sesam","title":"SESAM","description":"Syst\u00e8me de rapport de RTD du 7e PC (dont Marie Curie du 6e PC)","displayCode":"\/SESAM","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"rcn":"87830","id":"212109","relations":{"categories":[{"language":"fr","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Projet","description":"Fiches d\u0027information du projet","displayCode":"\/Projet","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"fr","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/77\/473\/1255","title":"g\u00e9nie sismique","displayCode":"\/ing\u00e9nierie et technologie\/g\u00e9nie civil\/ing\u00e9nierie des structures\/g\u00e9nie sismique","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"fr","availableLanguages":"en","code":"CP","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"fr","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"Centrale de donn\u00e9es de la recherche RTD","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"project","attributes":{"source":"sesam","type":"relatedProject"}},{"language":"any","availableLanguages":"en,any","uri":"\/docs\/results\/212\/212109\/final-report-efast.pdf","title":"final_report_EFAST","mimetype":"application\/pdf","size":"0","contenttype":"webItem","attributes":{"source":"undefined","type":"relatedResultAttachment"}}]},"contenttype":"result","attributes":{"source":"editorial","type":"relatedResult"}},{"language":"fr","availableLanguages":"de,en,es,fr,it,pl,any","uri":"\/docs\/results\/images\/2012-12\/54660.jpg","mimetype":"image\/jpeg","size":"0","copyright":"\u00a9 Thinkstock","contenttype":"webItem","attributes":{"represents":"article","source":"editorial","type":"relatedImage"}}],"regions":[{"name":"France","rcn":"258902568","nutsCode":"FR","euCode":"FR","isoCode":"FR","attributes":{"source":"editorial","type":"relatedRegion"}}]},"modelVersion":"132","icaVersion":"20.0.0-48f81e07"}