{"contenttype":"article","language":"en","availableLanguages":"de,en,es,fr,it,pl","rcn":"92513","id":"92513-thermal-comfort-for-fire-fightersinaction","title":"Thermal comfort for fire fighters-in-action","teaser":"Exposure to extreme heat when fighting a fire can cause heat exhaustion, injury and even death. A novel cooling vest may soon help firefighters artificially sweat through protective clothing for longer periods of activity.","body":"\u003Csection\u003E\u003CsectionBody\u003EFirefighters are in danger of experiencing thermal stress on exposure to the very high heat and thermal radiation associated with blazing fires. The main time-limiting factor for fire-fighters attending to a fire is thermal stress rather than air quality and smoke inhalation. Effective personal cooling could increase a fire-fighter\u0027s efficiency and reduce the risk of heat exhaustion. This should decrease injuries and improve the survival chances for fire-fighters and those they are called upon to help.\n\nScientists developed a novel garment that reduces core body temperature with EU funding of the project \u0027Lightweight, long endurance body cooling for fire fighters\u0027 (STAYCOOL). It promises to increase firefighter comfort and efficiency while reducing heat exhaustion-related accidents. The cooling vest acts to bypass the protective clothing worn by fire-fighters, \u0027sweating\u0027 through a biomimetic surface outside of the firefighter\u0027s protective clothing. It incorporates cooling pads or patches that are in touch with the skin and connected to a low-energy heat exchanger system. The heat exchangers use water to remove body heat and transfer it to the environment by evaporation.\n\nThe STAYCOOL system is lighter and consumes less energy than comparable cooling vests on the market. Both properties make it suitable for extended use. Its inexpensive, high-volume manufacturing processes help to keep unit costs very competitive. This could also be quite useful to industrial plant operators, police officers with protective clothing working in hot climates and even in extreme sports.\n\nCommercialisation should have major impact on the safety and comfort of fire-fighters while reducing the personal and infrastructure costs of fires. Regaining the market share from low-cost Asian imports and high-cost United States technology will also have important benefits for EU small and medium-sized enterprises.\u003C\/sectionBody\u003E\u003C\/section\u003E","contentCreationDate":"2014-04-02 15:34:40","contentUpdateDate":"2014-04-02 15:34:40","lastUpdateDate":"2023-10-02 08:33:55","archivedDate":"2024-06-10 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"indust","title":"Industrial Technologies","displayCode":"\/Industrial Technologies","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"brief","title":"Result in Brief","description":"Article: Classic and enhanced","displayCode":"\/Result in Brief","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"99604","id":"262673","acronym":"STAYCOOL","teaser":"There are about 500 000 professional fire fighters in the European Union (EU). When called to fight fires they can be exposed to high levels of heat stress, which results in decreased physical performance and even heat exhaustion. If a fire fighter succumbs to heat exhaustion...","title":"Lightweight, long endurance body cooling for fire fighters","archivedDate":"2024-06-18 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/63\/399","title":"textiles","displayCode":"\/engineering and technology\/materials engineering\/textiles","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/29\/93\/47293307","title":"ergonomics","displayCode":"\/social sciences\/psychology\/ergonomics","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"BSG-SME","title":"Research for SMEs","displayCode":"\/Research for SMEs","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"de,en,es,fr,it,pl","rcn":"862","code":"FP7-SME","frameworkProgramme":"FP7","pga":"FP7-SME","title":"Specific Programme \u0022Capacities\u0022: Research for the benefit of SMEs","shortTitle":"Research for the benefit of SMEs","parent":{"rcn":"847\/1401\/837","code":"FP7-CAPACITIES\/EC\/FP7"},"archivedDate":"2024-06-12 00:00:00","relations":{"categories":[{"language":"en","code":"legalbasis","title":"Legal Basis","description":"Programme: Legal basis for research funding","displayCode":"\/Legal Basis","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedLegalBasis"}},{"availableLanguages":"en","rcn":"10384","code":"SME-1","frameworkProgramme":"FP7","title":"Research for SMEs","parent":{"rcn":"11727\/862\/847\/1401\/837","code":"SME\/FP7-SME\/FP7-CAPACITIES\/EC\/FP7"},"archivedDate":"2024-06-14 00:00:00","relations":{"categories":[{"language":"en","code":"topic","title":"Topic","description":"Programme: Part of the Commission work programme implementing legal basis","displayCode":"\/Topic","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedTopic"}}]},"contenttype":"project","attributes":{"source":"editorial","type":"relatedProject"}},{"availableLanguages":"en","rcn":"57945","title":"Final Report Summary - STAYCOOL (Lightweight, long endurance body cooling for fire fighters)","teaser":"Executive summary\n\nCurrently, time spent attending to a fire is limited by thermal stress (surpassing the 39 \u00b0C body-temperature limit) experienced by the firefighter, and not by the amount of breathing air that is available. Control of wild fires can require firefighters to o...","contentUpdateDate":"2013-08-14 00:00:00","archivedDate":"2024-06-23 00:00:00","relations":{"categories":[{"language":"en","code":"pubsum","title":"Report Summary","description":"Result: Publishable summary (FP7 SESAM) and Summary for publication (H2020 SyGMa)","displayCode":"\/Report Summary","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"sesam","title":"SESAM","description":"RTD FP7 reporting system (including FP6 Marie Curie)","displayCode":"\/SESAM","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"rcn":"99604","id":"262673","title":"Lightweight, long endurance body cooling for fire fighters","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/63\/399","title":"textiles","displayCode":"\/engineering and technology\/materials engineering\/textiles","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/29\/93\/47293307","title":"ergonomics","displayCode":"\/social sciences\/psychology\/ergonomics","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"BSG-SME","title":"Research for SMEs","displayCode":"\/Research for SMEs","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"project","attributes":{"source":"sesam","type":"relatedProject"}},{"language":"en","availableLanguages":"en,any","uri":"\/docs\/results\/262\/262673\/staycool-final-publisable-summary-report.pdf","title":"Final Report - STAYCOOL (Lightweight, long endurance body cooling for fire fighters)","mimetype":"application\/pdf","size":"329065","description":"This is the final report of the STAYCOOL project, which is funded under the European Commission (EC) Seventh Framework Programme (FP7). The project developed the STAYCOOL personal cooling system, a lightweight mobile active cooling device designed to prevent thermal stress on humans, maintain a constant heat-extraction temperature at a comfortable range, and avoid the effect of cool spots. The system regulates body temperature through a set of patches on a garment in contact with skin. These patches are attached to a secondary water-cooled heat exchanger which removes the heat extracted from the body by evaporation. The STAYCOOL system can significantly increase the time a firefighter can spend attending a fire, thereby reducing the time taken to extinguish it, damage to property and potential loss of life. Further product development could focus on applications requiring low-weight, mobile and smart thermal stress control.","contenttype":"webItem","attributes":{"source":"undefined","type":"relatedResultAttachment"}}]},"contenttype":"result","attributes":{"source":"editorial","type":"relatedResult"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl,any","uri":"\/docs\/results\/images\/2014-04\/57945.jpg","mimetype":"image\/jpeg","size":"0","copyright":"\u00a9 Thinkstock","contenttype":"webItem","attributes":{"represents":"article","source":"editorial","type":"relatedImage"}}]},"modelVersion":"132","icaVersion":"20.0.0-48f81e07"}