{"contenttype":"programme","language":"en","availableLanguages":"en","rcn":"708120","id":"HORIZON_HORIZON-JTI-CLEANH2-2023-03-02","cordaId":"45808652","code":"HORIZON-JTI-CLEANH2-2023-03-02","frameworkProgramme":"HORIZON","title":"Development of a large fuel cell stack for maritime applications","teaser":"Proposals should cover the development of a high-power stack for maritime applications and should address in particular either PEM or Solid Oxide technologies, which are considered the most promising technologies for maritime sector as already proven by the already funded...","objective":"\u003Cp\u003EProposals should cover the development of a high-power stack for maritime applications and should address in particular either PEM or Solid Oxide technologies, which are considered the most promising technologies for maritime sector as already proven by the already funded projects MARANDA[[\u003Ca href=\u0022https:\/\/cordis.europa.eu\/project\/id\/735717\/es\u0022\u003Ehttps:\/\/cordis.europa.eu\/project\/id\/735717\/es\u003C\/a\u003E]], HyShip[[\u003Ca href=\u0022https:\/\/cordis.europa.eu\/project\/id\/101007205\u0022\u003Ehttps:\/\/cordis.europa.eu\/project\/id\/101007205\u003C\/a\u003E]], FLAGSHIPS[[\u003Ca href=\u0022https:\/\/cordis.europa.eu\/project\/id\/826215\u0022\u003Ehttps:\/\/cordis.europa.eu\/project\/id\/826215\u003C\/a\u003E]], and ShipFC.\u003C\/p\u003E\u003Cp\u003EA large FC stack for maritime applications should be developed by the end of the project according to either one of the following minimum requirements:\u003C\/p\u003E\u003Cul level=\u00220\u0022\u003E\u003Cli\u003EA PEM stack with nominal power in the range of 250-500 kW at beginning of life and with scalability at system level to several tens of MW;\u003C\/li\u003E \u003C\/ul\u003E\u003Cp\u003Eor\u003C\/p\u003E\u003Cul level=\u00220\u0022\u003E\u003Cli\u003EA Solid Oxide (SO) stack with nominal power in the range of 100-250 kW at beginning of life and with scalability at system level to tens of MW.\u003C\/li\u003E \u003C\/ul\u003E\u003Cp\u003EAbove mentioned power capacity levels should be targeted at single stack level (not at subsystem level, overcoming stacks currently validated in the projects HyShip, FLAGSHIPS, MARANDA and ShipFC) with a robust testing campaign to prove stack reliability.\u003C\/p\u003E\u003Cp\u003EResearch should be undertaken based on the newly developed stacks in view of outlining a pathway for a fuel cell system of high power (multi-MW range) that can be adapted to maritime applications (building on the project outcomes and integrating stacks developed in this project), with spill overs towards stationary applications.\u003C\/p\u003E\u003Cp\u003EEach project should develop one stack technology (PEM or SO) and therefore, at least one FC stack manufacturer should be part of the consortium.\u003C\/p\u003E\u003Cp\u003EFor this purpose, the stack should be developed and validated in relevant environment (at the end of the project, each stack should reach at minimum TRL 6 considering:\u003C\/p\u003E\u003Cul level=\u00220\u0022\u003E\u003Cli\u003EThe optimised design of a large active area stack design (PEMFC stack in the range 250-500kW; SOFC stack in the range 100-250 kW) able to operate in multi-modal modular stack systems towards 10 MW scale (also based on the StaSHH project guidelines[[\u003Ca href=\u0022https:\/\/www.stashh.eu\/\u0022\u003Ehttps:\/\/www.stashh.eu\/\u003C\/a\u003E.]] defining an open standard for heavy-duty fuel-cell modules);\u003C\/li\u003E\u003Cli\u003EAt least 2,000 hours of testing of the stack, to be fully characterised in relevant environment, enabling to test modules in moisty and salty conditions and considering different air inlet temperature (to simulate different installation areas on board of vessels);\u003C\/li\u003E\u003Cli\u003EThe FC stack should be validated to provide power according to sailing profile\/load request of a real vessel in a simulation approach;\u003C\/li\u003E\u003Cli\u003EHigh reliability and robustness of FC cell components with high lifetime requirements (\u0026gt; 40,000 hours in maritime application, to be guaranteed via ex-situ and in-situ qualification of components;\u003C\/li\u003E\u003Cli\u003EThe stack should incorporate features allowing for an on-line diagnostic and prognostics with the goal of reaching a target stack life of 40,000 hours (lifetime of FC stack);\u003C\/li\u003E\u003Cli\u003EDemonstration of 40,000 hours stack life should be performed by means of accelerated test procedure, which should also be developed as part of the project;\u003C\/li\u003E\u003Cli\u003EThe definition of manufacturing and production processes and tolerances for the upscale of the components of the large fuel cell stack;\u003C\/li\u003E\u003Cli\u003EMulti-modular connected stack should be able to operate when subject to vibrations and to temporary (for limited duration) tilting of +\/- 22.5\u00b0 in all directions;\u003C\/li\u003E\u003Cli\u003EIdentification of appropriate air filter specific for marine application should be also part of the project;\u003C\/li\u003E\u003Cli\u003EDiagnostic and prognostics of the FC Stack should be developed also targeting features that could advice in advance the best timing for air filter replacement;\u003C\/li\u003E\u003Cli\u003EDevelopment of innovative measuring \/ sensor architecture and devices for proposed diagnostics approaches and testing purposes.\u003C\/li\u003E \u003C\/ul\u003E\u003Cp\u003EDevelopment of a full FC system is not expected at this stage, the focus should be at stack level where versatility (in terms of responsiveness to load demand of different on-board services and type of vessels) is key. Nevertheless, the proposed solutions should be conceived as multi-modular connected stacks. Development of a proper power electronics\/conversion architecture to be developed hand-in-hand with proposed stack and development of single stack to be used into the connected stack system below should be integral part of the project. Therefore, the following specifications should be considered:\u003C\/p\u003E\u003Cul level=\u00220\u0022\u003E\u003Cli\u003EDevelopment should include a multi-modular connection for single stacks into one connected stack system with power from 1 to 5 MW;\u003C\/li\u003E\u003Cli\u003EThe multi-modular connected stack boundary should be designed in a way that the system integrator uses it as a single fuel cell stack;\u003C\/li\u003E\u003Cli\u003EMulti-modular connected stack VI curve and more in general electrical characteristics should be compatible with the commonly used power electronic in the marine application for the 1 to 5 MW range;\u003C\/li\u003E\u003Cli\u003EClear plan for further progress of the technologies towards systems integrated in their powertrain applications should be outlined;\u003C\/li\u003E\u003Cli\u003EClear plan for future capability of the proposed SOFC Stack to operate with fuels different than pure hydrogen should be developed (e.g. ammonia, methanol, natural gas (NG), liquid organic hydrogen carriers (LOHC)\u2026 - which could serve as transition fuels for the sector in the near future) should be developed.\u003C\/li\u003E \u003C\/ul\u003E\u003Cp\u003ELooking at future development and on-board integration, the following activities should be envisaged:\u003C\/p\u003E\u003Cul level=\u00220\u0022\u003E\u003Cli\u003EScale up activities (targeting specific multi-stack FC systems sizes and cost functions), the setup of a roadmap to TRL9 and the development of potential studies for MW-scale integration on board (and FC stack\/system design) are also required. At least one use case , supported by an industrial ship-owner\/manager (expected to be part of the consortium or of the Advisory Board), should be developed during the project;\u003C\/li\u003E\u003Cli\u003EEngagement of end-users is crucial to collect their feedback about the proposed FC technology, also at regulatory and non-technical level. In this sense, support from ZEWT partnership is of particular importance;\u003C\/li\u003E\u003Cli\u003EThe possibility to study the applicability of proposed FC stack with batteries and in hybrid systems with traditional on-board propulsion system ,e.g . SOFC gas turbine (GT) system (cycle integrating SOFC and GT) and ICE should be explored at simulation or at experimental level.\u003C\/li\u003E \u003C\/ul\u003E\u003Cp\u003ECooperation with FC application in other maritime or similar projects is expected (such as StaSHH, HyShip, FLAGSHIPS, MARANDA, ShipFC, etc.) in order to start from their results on stack design. Proposals are expected to explore synergies with the activities of ZEWT partnership.\u003C\/p\u003E\u003Cp\u003EWhile designing the FC stack, applicants should apply a \u2018circularity by design\u2019 approach and assess the sustainability of the proposed solutions from a life cycle perspective (also benchmarking it with batteries and other FCs not investigated in design\/demonstration). e.g. should estimate the carbon footprint expressed in gr CO2-eq\/kWh\u003Csub\u003Eel\u003C\/sub\u003E.\u003C\/p\u003E\u003Cp\u003EActivities developing test protocols and procedures for the performance and durability assessment of electrolysers and fuel cell components proposals should foresee a collaboration mechanism with JRC (see section 2.2.4.3 \u0022Collaboration with JRC\u0022), in order to support EU-wide harmonisation. Test activities should adopt the already published EU harmonised testing protocols[[\u003Ca href=\u0022https:\/\/www.clean-hydrogen.europa.eu\/knowledge-management\/collaboration-jrc-0_en\u0022\u003Ehttps:\/\/www.clean-hydrogen.europa.eu\/knowledge-management\/collaboration-jrc-0_en\u003C\/a\u003E]] to benchmark performance and quantify progress at programme level.\u003C\/p\u003E\u003Cp\u003E\u003Cstrong\u003EActivities are expected to start at TRL 4 and achieve TRL 6 by the end of the project - see General Annex B.\u003C\/strong\u003E\u003C\/p\u003E\u003Cp\u003E\u003Cstrong\u003EThe JU estimates that an EU contribution of maximum EUR 7.50 million would allow these outcomes to be addressed appropriately.\u003C\/strong\u003E\u003C\/p\u003E\u003Cp\u003E\u003Cstrong\u003EThe conditions related to this topic are provided in the chapter 2.2.3.2 of the Clean Hydrogen JU 2023 Annual Work Plan and in the General Annexes to the Horizon Europe Work Programme 2023\u20132024 which apply mutatis mutandis.\u003C\/strong\u003E\u003C\/p\u003E","parent":{"rcn":"20300","code":"HORIZON-Topics"},"sourceUpdateDate":"2022-12-16 15:45:35","contentCreationDate":"2022-12-26 18:38:58","contentUpdateDate":"2022-12-26 18:38:48","lastUpdateDate":"2025-07-02 17:31:58","relations":{"associations":[{"availableLanguages":"en","rcn":"56133","title":"HORIZON-JTI-CLEANH2-2023-1","identifier":"HORIZON-JTI-CLEANH2-2023-1","contenttype":"call","attributes":{"source":"corda","type":"relatedCall"}},{"availableLanguages":"en","rcn":"705767","id":"HORIZON.2.5","code":"HORIZON.2.5","title":"Climate, Energy and Mobility","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"legalbasis","title":"Legal Basis","displayCode":"\/Legal Basis","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedLegalBasis"}}],"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"topic","title":"Topic","displayCode":"\/Topic","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}},{"language":"en","availableLanguages":"en","code":"43451404","title":"Electrochemistry, batteries and fuel cells","displayCode":"\/Electrochemistry, batteries and fuel cells","attributes":{"classification":"topicKeyword","type":"isAbout"}},{"language":"en","availableLanguages":"en","code":"43453348","title":"Hydrogen","displayCode":"\/Hydrogen","attributes":{"classification":"topicKeyword","type":"isAbout"}},{"language":"en","availableLanguages":"en","code":"43452376","title":"Fuel cell technology","displayCode":"\/Fuel cell technology","attributes":{"classification":"topicKeyword","type":"isAbout"}}]},"modelVersion":"132","icaVersion":"20.0.0-48f81e07"}