{"contenttype":"project","language":"en","availableLanguages":"en","rcn":"250791","id":"101088351","acronym":"GLUCO-SCAN","teaser":"The targeted scientific breakthrough of GLUCO-SCAN is the development and clinical evaluation of a disruptive whole-body molecular imaging concept for cancer assessment. The only currently established whole-body molecular imaging device is positron emission tomography (PET)...","objective":"The targeted scientific breakthrough of GLUCO-SCAN is the development and clinical evaluation of a disruptive whole-body molecular imaging concept for cancer assessment. The only currently established whole-body molecular imaging device is positron emission tomography (PET). Glucose (Glc)-sensitive PET is widely used in cancer diagnosis and treatment assessment, but has several major limitations: PET involves harmful ionizing radiation, is expensive, not widely available, and cannot differentiate between cancer-specific and normal cellular glucose uptake. These limitations prohibit an even more widespread use of PET, e.g. for screening. We propose a new Magnetic Resonance Imaging (MRI) concept, whole-body deuterium metabolic imaging (DMI) that will overcome these limitations.\nDeuteration is a simple chemical procedure with which it is possible to artificially label a broad range of molecules with an equally broad range of potential applications, e.g., targeting Glc metabolism in cancer. After ingestion, this labeled Glc is metabolized in cells and the label is transferred to all metabolic products, which can be tracked by DMI.\nBuilding on our recent preliminary results in Nature Biomed, we propose a combination of novel MRI hardware, dynamic spectroscopic data sampling, deep learning algorithms, and a clinical validation to answer the following three research questions in a 5-year project:\n(i) Is DMI a viable alternative for whole-body cancer assessment?\n(ii) How is DMI positioned compared to Glc-sensitive PET?\n(iii) Can DMI be performed on widely available MRI systems and simultaneous with standard MRI?\nGLUCO-SCAN will fill a gap in current medical imaging by offering an alternative for whole-body PET examinations and potentially even for screening of high risk populations. Ultimately, it will pave the way for a new generation of MR scanners with all-in-one whole-body imaging capability that would capture morphologic and molecular information simultaneously.","title":"Deuterium labeling of GLUCOse improves magnetic resonance imaging Sensitivity to CANcer metabolism","keywords":"Magnetic resonance imaging, magnetic resonance spectroscopy, ultra-high field, glucose metabolism, oxidative\/glycolytic metabolism, cancer diagnosis, oncology","totalCost":"2495924","ecMaxContribution":"2495924","startDate":"2023-12-01","endDate":"2028-11-30","ecSignatureDate":"2023-06-05","duration":"60","status":"SIGNED","identifiers":{"grantDoi":"10.3030\/101088351"},"validation":{"euroSciVoc":"true"},"sourceUpdateDate":"2025-11-13 07:46:05","contentCreationDate":"2023-06-28 15:12:14","contentUpdateDate":"2025-11-13 07:46:05","lastUpdateDate":"2026-11-05 08:21:39","relations":{"associations":[{"availableLanguages":"de,en,es,fr,it,pl","rcn":"444671","id":"444671-deuterium-labelling-to-enhance-magnetic-resonance-imaging-specificity-and-sensitivity-in","title":"Deuterium labelling to enhance magnetic resonance imaging specificity and sensitivity in cancer diagnostics","contentUpdateDate":"2023-11-27 10:33:49","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"projectDescription","title":"Project description","description":"Article: description of linked project written by editorial team","displayCode":"\/Project description","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"relatedArticle"}},{"rcn":"55605","title":"ERC-2022-COG","identifier":"ERC-2022-COG","contenttype":"call","attributes":{"source":"corda","type":"relatedMasterCall"}},{"rcn":"55605","title":"ERC-2022-COG","identifier":"ERC-2022-COG","contenttype":"call","attributes":{"source":"corda","type":"relatedSubCall"}},{"availableLanguages":"en","rcn":"1905549","id":"999989976","vatNumber":"ATU57469858","legalName":"MEDIZINISCHE UNIVERSITAET WIEN","address":{"street":"SPITALGASSE 23","city":"Wien","postalCode":"1090","country":"AT","url":"http:\/\/www.meduniwien.ac.at","geolocation":"48.20832,16.36984"},"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"HES","title":"Higher or Secondary Education Establishments","displayCode":"\/Higher or Secondary Education Establishments","attributes":{"classification":"organizationActivityType","type":"relatedOrganizationActivityType"}}],"regions":[{"name":"Wien","rcn":"175378624","nutsCode":"AT130","parents":{"name":"Wien\/Ost\u00f6sterreich\/Austria","rcn":"175378664\/1465444\/175540776","nutsCode":"AT13\/AT1\/AT","euCode":"AT","isoCode":"AT"},"attributes":{"type":"relatedNutsCode"}},{"name":"Austria","rcn":"175540776","nutsCode":"AT","euCode":"AT","isoCode":"AT","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"ecContribution":"2495924","sme":"false","source":"corda","type":"coordinator","netEcContribution":"2495924","terminated":"false","totalCost":"2495924","order":"1"}},{"availableLanguages":"en","rcn":"705727","id":"HORIZON.1.1","code":"HORIZON.1.1","frameworkProgramme":"HORIZON","pga":"HORIZON.1.1","title":"European Research Council (ERC)","parent":{"rcn":"705726\/705725","code":"HORIZON.1\/HORIZON"},"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"legalbasis","title":"Legal Basis","description":"Programme: Legal basis for research funding","displayCode":"\/Legal Basis","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedLegalBasis","uniqueProgrammePart":"true"}},{"availableLanguages":"en","rcn":"706731","id":"HORIZON_ERC-2022-COG","code":"ERC-2022-COG","frameworkProgramme":"HORIZON","title":"ERC CONSOLIDATOR GRANTS","parent":{"rcn":"20300","code":"HORIZON-Topics"},"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"topic","title":"Topic","description":"Programme: Part of the Commission work programme implementing legal basis","displayCode":"\/Topic","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedTopic"}},{"availableLanguages":"en","rcn":"1419229","id":"101088351_299475_PUBLIHORIZON","title":"Comparison of Low\u2010Rank Denoising Methods for Dynamic Deuterium MRSI at 7\u2009T","details":"\r\n    \u003Cauthors\u003EAnna Duguid; Fabian Niess; Wolfgang Bogner; Lukas Hingerl; Viola Bader; Sabina Frese; Aaron Osburg; Bernard Lanz; Brayan Alves; Cristina Cudalbu; Simon\u00a0Daniel Robinson; Korbinian Eckstein; Bernhard S\u003C\/authors\u003E\r\n    \u003CjournalNumber \/\u003E\r\n    \u003CjournalTitle\u003ENMR in Biomedicine\u003C\/journalTitle\u003E\r\n    \u003CpublishedPages \/\u003E\r\n    \u003CpublishedYear\u003E2025\u003C\/publishedYear\u003E\r\n    \u003Cpublisher\u003EWiley\u003C\/publisher\u003E\r\n  ","identifiers":{"doi":"10.1002\/NBM.70125","issn":["1099-1492"]},"sourceUpdateDate":"2026-01-16 13:38:52","contentUpdateDate":"2026-01-18 10:54:17","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"publication","title":"Project publication","description":"Result: Project publications","displayCode":"\/Project publication","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"PEER_REVIEWED_ARTICLE","title":"Peer reviewed articles","displayCode":"\/Peer reviewed articles","attributes":{"classification":"projectPublication","type":"isPublishedAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"1515511","id":"101088351_468752_PUBLIHORIZON","title":"Assessment of T1 and T2 relaxation times of deuterium (2H) labeled resonances in the human liver and kidney using k-space reordered 3D concentric ring trajectory sampling at 7T","details":"\r\n    \u003Cauthors\u003EViola Bader; Bernhard Strasser; Lukas Hingerl; Johannes J. Kovarik; Sabina Frese; Lorenz Pfleger; Anna Duguid; Aaron Osburg; Martin Kr\u0161\u0161\u00e1k; Thomas Scherer; Wolfgang Bogner; Fabian Niess\u003C\/authors\u003E\r\n    \u003CjournalNumber \/\u003E\r\n    \u003CjournalTitle\u003EMagnetic Resonance Materials in Physics, Biology and Medicine\u003C\/journalTitle\u003E\r\n    \u003CpublishedPages \/\u003E\r\n    \u003CpublishedYear\u003E2026\u003C\/publishedYear\u003E\r\n    \u003Cpublisher\u003ESpringer Nature\u003C\/publisher\u003E\r\n  ","identifiers":{"doi":"10.1007\/S10334-025-01320-9","issn":["1352-8661"]},"sourceUpdateDate":"2026-07-04 06:10:31","contentUpdateDate":"2026-07-08 09:32:57","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"publication","title":"Project publication","description":"Result: Project publications","displayCode":"\/Project publication","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"PEER_REVIEWED_ARTICLE","title":"Peer reviewed articles","displayCode":"\/Peer reviewed articles","attributes":{"classification":"projectPublication","type":"isPublishedAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"1515519","id":"101088351_468751_PUBLIHORIZON","title":"Advanced methods in deuterium metabolic imaging","details":"\r\n    \u003Cauthors\u003EFabian Niess; Bernhard Strasser; Bernard Lanz; Wolfgang Bogner\u003C\/authors\u003E\r\n    \u003CjournalNumber \/\u003E\r\n    \u003CjournalTitle\u003EMagnetic Resonance Materials in Physics, Biology and Medicine\u003C\/journalTitle\u003E\r\n    \u003CpublishedPages \/\u003E\r\n    \u003CpublishedYear\u003E2026\u003C\/publishedYear\u003E\r\n    \u003Cpublisher\u003ESpringer Nature\u003C\/publisher\u003E\r\n  ","identifiers":{"doi":"10.1007\/S10334-026-01322-1","issn":["1352-8661"]},"sourceUpdateDate":"2026-07-04 06:10:31","contentUpdateDate":"2026-07-08 09:33:02","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"publication","title":"Project publication","description":"Result: Project publications","displayCode":"\/Project publication","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"PEER_REVIEWED_ARTICLE","title":"Peer reviewed articles","displayCode":"\/Peer reviewed articles","attributes":{"classification":"projectPublication","type":"isPublishedAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"1419298","id":"101088351_299480_PUBLIHORIZON","title":"A deep autoencoder for fast spectral\u2013temporal fitting of dynamic deuterium metabolic imaging data at 7T","details":"\r\n    \u003Cauthors\u003EAaron Paul Osburg, Amirmohammad Shamaei, Bernhard Strasser, Fabian Niess, Anna Duguid, Viola Bader, Sabina Frese, Lukas Hingerl, Hauke Fischer, William T. Clarke, Georg Langs, Wolfgang Bogner, Stanisl\u003C\/authors\u003E\r\n    \u003CjournalNumber\u003E324\u003C\/journalNumber\u003E\r\n    \u003CjournalTitle\u003ENeuroImage\u003C\/journalTitle\u003E\r\n    \u003CpublishedPages \/\u003E\r\n    \u003CpublishedYear\u003E2025\u003C\/publishedYear\u003E\r\n    \u003Cpublisher\u003EElsevier BV\u003C\/publisher\u003E\r\n  ","identifiers":{"doi":"10.1016\/J.NEUROIMAGE.2025.121632","issn":["1053-8119"]},"sourceUpdateDate":"2026-01-16 13:38:52","contentUpdateDate":"2026-01-18 10:54:33","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"publication","title":"Project publication","description":"Result: Project publications","displayCode":"\/Project publication","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"PEER_REVIEWED_ARTICLE","title":"Peer reviewed articles","displayCode":"\/Peer reviewed articles","attributes":{"classification":"projectPublication","type":"isPublishedAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"1565941","id":"101088351_PSHORIZON","title":"Periodic Reporting for period 1 - GLUCO-SCAN (Deuterium labeling of GLUCOse improves magnetic resonance imaging Sensitivity to CANcer metabolism)","teaser":"GLUCO-SCAN addresses a central need in oncology: clinicians require whole-body information on tumor metabolism to detect disease, stage it, and monitor therapy. Today this role is largely fulfilled by glucose-sensitive positron-emission tomography (FDG-PET) (often combined...","description":"periodic","sourceUpdateDate":"2026-11-04 07:22:10","contentUpdateDate":"2026-11-05 08:21:36","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"pubsum","title":"Report Summary","description":"Result: Publishable summary (FP7 SESAM) and Summary for publication (H2020 SyGMa)","displayCode":"\/Report Summary","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"1419288","id":"101088351_299478_PUBLIHORIZON","title":"Concentric Ring Trajectory Sampling With k\u2010Space Reordering Enables Assessment of Tissue\u2010Specific \u003Ci\u003ET\u003C\/i\u003E\u003Csub\u003E1\u003C\/sub\u003E and \u003Ci\u003ET\u003C\/i\u003E\u003Csub\u003E2\u003C\/sub\u003E Relaxation for \u003Csup\u003E2\u003C\/sup\u003EH\u2010Labeled Substrates in","details":"\r\n    \u003Cauthors\u003EBader, V; Strasser, B; Bogner, W; Hingerl, L; Frese, S; Duguid, A; Osburg, A; Clarke, W; Motyka, S; Krssak, M; Trattnig, S; Scherer, T; Lanzenberger, R; Niess, F\u003C\/authors\u003E\r\n    \u003CjournalNumber \/\u003E\r\n    \u003CjournalTitle\u003ENMR in Biomedicine\u003C\/journalTitle\u003E\r\n    \u003CpublishedPages \/\u003E\r\n    \u003CpublishedYear\u003E2024\u003C\/publishedYear\u003E\r\n    \u003Cpublisher\u003EWiley\u003C\/publisher\u003E\r\n  ","identifiers":{"doi":"10.1002\/NBM.5311","issn":["1099-1492"]},"sourceUpdateDate":"2026-01-16 13:38:52","contentUpdateDate":"2026-01-18 10:54:32","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"publication","title":"Project publication","description":"Result: Project publications","displayCode":"\/Project publication","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"PEER_REVIEWED_ARTICLE","title":"Peer reviewed articles","displayCode":"\/Peer reviewed articles","attributes":{"classification":"projectPublication","type":"isPublishedAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"1419291","id":"101088351_299485_PUBLIHORIZON","title":"Balanced Steady-State Free Precession Enables High-Resolution Dynamic 3D Deuterium Metabolic Imaging of the Human Brain at 7T","details":"\r\n    \u003Cauthors\u003ESabina Frese, Bernhard Strasser, Lukas Hingerl, Elton Montrazi, Lucio Frydman, Stanislav Motyka, Viola Bader, Anna Duguid, Aaron Osburg, Martin Krssak, Rupert Lanzenberger, Thomas Scherer, Wolfgang Bo\u003C\/authors\u003E\r\n    \u003CjournalNumber\u003E61\u003C\/journalNumber\u003E\r\n    \u003CjournalTitle\u003EInvestigative Radiology\u003C\/journalTitle\u003E\r\n    \u003CpublishedPages \/\u003E\r\n    \u003CpublishedYear\u003E2025\u003C\/publishedYear\u003E\r\n    \u003Cpublisher\u003EOvid Technologies (Wolters Kluwer Health)\u003C\/publisher\u003E\r\n  ","identifiers":{"doi":"10.1097\/RLI.0000000000001196","issn":["1536-0210"]},"sourceUpdateDate":"2026-01-16 13:38:52","contentUpdateDate":"2026-01-18 10:54:32","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"publication","title":"Project publication","description":"Result: Project publications","displayCode":"\/Project publication","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"PEER_REVIEWED_ARTICLE","title":"Peer reviewed articles","displayCode":"\/Peer reviewed articles","attributes":{"classification":"projectPublication","type":"isPublishedAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"1419289","id":"101088351_299477_PUBLIHORIZON","title":"Whole\u2010brain deuterium metabolic imaging via concentric ring trajectory readout enables assessment of regional variations in neuronal glucose metabolism","details":"\r\n    \u003Cauthors\u003ENiess, F; Strasser, B; Hingerl, L; Bader, V; Frese, S; Clarke, WT; Duguid, A; Niess, E; Motyka, S; Kr\u0161\u0161\u00e1k, M; Trattnig, S; Scherer, T; Lanzenberger, R; Bogner, W\u003C\/authors\u003E\r\n    \u003CjournalNumber \/\u003E\r\n    \u003CjournalTitle\u003EHuman Brain Mapping\u003C\/journalTitle\u003E\r\n    \u003CpublishedPages \/\u003E\r\n    \u003CpublishedYear\u003E2024\u003C\/publishedYear\u003E\r\n    \u003Cpublisher\u003EWiley\u003C\/publisher\u003E\r\n  ","identifiers":{"doi":"10.1002\/HBM.26686","issn":["1097-0193"]},"sourceUpdateDate":"2026-01-16 13:38:52","contentUpdateDate":"2026-01-18 10:54:32","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"publication","title":"Project publication","description":"Result: Project publications","displayCode":"\/Project publication","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"PEER_REVIEWED_ARTICLE","title":"Peer reviewed articles","displayCode":"\/Peer reviewed articles","attributes":{"classification":"projectPublication","type":"isPublishedAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"1419297","id":"101088351_299476_PUBLIHORIZON","title":"Feasibility of High\u2010Resolution Deuterium Metabolic Imaging of the Human Kidney Using Concentric Ring Trajectory Sampling at 7T","details":"\r\n    \u003Cauthors\u003EFabian Niess; Bernhard Strasser; Lukas Hingerl; Johannes\u00a0J. Kovarik; Viola Bader; Sabina Frese; Anna Duguid; Aaron Osburg; Eva Niess; Stanislav Motyka; Martin Kr\u0161\u0161\u00e1k; Thomas Scherer; Wolfgang Bogn\u003C\/authors\u003E\r\n    \u003CjournalNumber \/\u003E\r\n    \u003CjournalTitle\u003ENMR in Biomedicine\u003C\/journalTitle\u003E\r\n    \u003CpublishedPages \/\u003E\r\n    \u003CpublishedYear\u003E2025\u003C\/publishedYear\u003E\r\n    \u003Cpublisher\u003EWiley\u003C\/publisher\u003E\r\n  ","identifiers":{"doi":"10.1002\/NBM.70139","issn":["1099-1492"]},"sourceUpdateDate":"2026-01-16 13:38:52","contentUpdateDate":"2026-01-18 10:54:33","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"publication","title":"Project publication","description":"Result: Project publications","displayCode":"\/Project publication","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"PEER_REVIEWED_ARTICLE","title":"Peer reviewed articles","displayCode":"\/Peer reviewed articles","attributes":{"classification":"projectPublication","type":"isPublishedAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"1530016","id":"101088351_545913_PUBLIHORIZON","title":"Self-supervised spectral\u2013temporal denoising for dynamic deuterium metabolic imaging","details":"\r\n    \u003Cauthors\u003EHauke Fischer, Stanislav Motyka, Anna Duguid, Fabian Niess, Bernhard Strasser, Viola Bader, Sabina Frese, Sara Huskic, Georg Widhalm, Sumit Kaushik, Aaron P. Osburg, Wolfgang Bogner\u003C\/authors\u003E\r\n    \u003CjournalNumber\u003E338\u003C\/journalNumber\u003E\r\n    \u003CjournalTitle\u003ENeuroImage\u003C\/journalTitle\u003E\r\n    \u003CpublishedPages \/\u003E\r\n    \u003CpublishedYear\u003E2026\u003C\/publishedYear\u003E\r\n    \u003Cpublisher\u003EElsevier BV\u003C\/publisher\u003E\r\n  ","identifiers":{"doi":"10.1016\/J.NEUROIMAGE.2026.122137","issn":["1053-8119"]},"sourceUpdateDate":"2026-07-30 04:44:25","contentUpdateDate":"2026-09-11 13:29:52","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"publication","title":"Project publication","description":"Result: Project publications","displayCode":"\/Project publication","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"PEER_REVIEWED_ARTICLE","title":"Peer reviewed articles","displayCode":"\/Peer reviewed articles","attributes":{"classification":"projectPublication","type":"isPublishedAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}}],"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/21\/39\/225","title":"oncology","displayCode":"\/medical and health sciences\/clinical medicine\/oncology","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/47\/297\/933\/1589","title":"deep learning","displayCode":"\/natural sciences\/computer and information sciences\/artificial intelligence\/machine learning\/deep learning","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/57\/693\/1455","title":"magnetic resonance imaging","displayCode":"\/engineering and technology\/medical engineering\/diagnostic imaging\/magnetic resonance imaging","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"digitalAgenda","title":"Digital agenda","description":"This tracker monitors Horizon Europe\u2019s financial contribution to the development of digital technologies and the digitisation of the economy and society (known as \u2018Digital transition\u2019).","displayCode":"\/Digital agenda","attributes":{"weight":"0","classification":"policyPriorities","type":"marker"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"cleanAir","title":"Clean air","description":"This tracker monitors the Horizon Europe\u2019s financial contribution to the clean air policy (National Emission Ceiling Directive) aiming to improve ambient air quality and tackle air pollution, to protect the environment and human health.","displayCode":"\/Clean air","attributes":{"weight":"0","classification":"policyPriorities","type":"marker"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"ai","title":"Artificial intelligence","description":"This tracker monitors Horizon Europe\u2019s financial contribution to the development and deployment of AI-based technologies and solutions. Projects that develop AI-tools as part of their research method are included","displayCode":"\/Artificial intelligence","attributes":{"weight":"0","classification":"policyPriorities","type":"marker"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"climate","title":"Climate action","description":"This tracker monitors the Horizon Europe\u2019s financial contribution to both mitigating climate change (e.g., contributions to the reduction of greenhouse gas emissions) and adapting to climate change by building resilience (e.g., regarding floods, droughts, spatial planning and better governance, adaptation to changing climate in value chains, etc.).","displayCode":"\/Climate action","attributes":{"weight":"0","classification":"policyPriorities","type":"marker"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"biodiversity","title":"Biodiversity","description":"This tracker monitors the Horizon Europe\u2019s financial contribution to Europe\u2019s biodiversity\u2019s path to recovery including species protection, ecosystem conservation, and habitat rehabilitation, all essential for resilience in climate adaptation and addressing ecosystem services but also environmental crime and the health-environment connection.","displayCode":"\/Biodiversity","attributes":{"weight":"0","classification":"policyPriorities","type":"marker"}},{"language":"en","availableLanguages":"en","code":"HORIZON-ERC","title":"HORIZON ERC Grants","description":"HORIZON ERC Grants","displayCode":"\/HORIZON ERC Grants","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"modelVersion":"132","icaVersion":"20.0.0-48f81e07"}