{"contenttype":"project","language":"en","availableLanguages":"en","rcn":"86247","id":"212825","acronym":"PROTEST","teaser":"One of the major causes of failures of mechanical systems (e.g. drive trains, pitch systems, and yaw systems) in wind turbines is insufficient knowledge of the loads acting on these components. The objective of this pre-normative project is to set up a methodology that enable...","objective":"One of the major causes of failures of mechanical systems (e.g. drive trains, pitch systems, and yaw systems) in wind turbines is insufficient knowledge of the loads acting on these components. The objective of this pre-normative project is to set up a methodology that enables better specification of design loads for the mechanical components. The design loads will be specified at the interconnection points where the component can be \u0026quot;isolated\u0026quot; from the entire wind turbine structure (for gearboxes for instance the interconnection points are the shafts and the attachments to the nacelle frame). The focus will be on developing guidelines for measuring load spectra at the interconnection points during prototype measurements and to compare them with the initial design loads. Ultimately, the new procedures for the mechanical components will be brought at the same high level as the state-of-the-art procedures for designing and testing rotor blades and towers which are critical to safety. A well balanced consortium, consisting of a turbine manufacturer, component manufacturer, certification institute, and R\u0026amp;D institutes will describe the current practice for designing and developing mechanical components. Based on this starting point, the project team will draft improved procedures for determining loads at the interconnection points. The draft procedures will be applied to three case studies with each a different focus, viz. determining loads at the drive train, pitch system, and yaw system; the latter one taking into account complex terrain. The procedures will be assessed by the project team and depending on the outcome the procedures will be updated accordingly and disseminated. All partners will incorporate the new procedures in their daily practices for designing turbines and components, certifying them, and carrying out prototype measurements. Project results will be submitted to relevant standardisation committees.","title":"PROcedures for TESTing and measuring wind energy systems","keywords":"drive,energy,loads,measurements,mechanical,mechanical loads,reliability,reliability drive,standards,train,wind,wind energy,wind energy mechanical loads reliability drive train standards measurements","totalCost":"2675619","ecMaxContribution":"1980119","startDate":"2008-03-01","endDate":"2010-08-31","duration":"30","status":"CLOSED","validation":{"euroSciVoc":"false"},"contentCreationDate":"2008-03-31 00:00:00","contentUpdateDate":"2019-07-15 16:01:18","lastUpdateDate":"2026-02-18 16:58:39","archivedDate":"2024-06-18 00:00:00","relations":{"associations":[{"availableLanguages":"de,en,es,fr,it,pl","rcn":"86130","id":"86130-wind-turbines-examined-to-improve-technology","title":"Wind turbines examined to improve technology","teaser":"A series of reports on wind turbines, their mechanical systems, loads and rotor blades will improve their construction and workings.","contentUpdateDate":"2011-02-14 12:51:34","archivedDate":"2024-06-10 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"ener","title":"Energy","displayCode":"\/Energy","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"brief","title":"Result in Brief","description":"Article: Classic and enhanced","displayCode":"\/Result in Brief","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"de,en,es,fr,it,pl","rcn":"400703","title":"Research for regions: a coherent research area for Europe","archivedDate":"2024-05-29 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"mag","title":"research*eu magazine","description":"Article: Both results and focus magazines","displayCode":"\/research*eu magazine","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"isContainedIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl,any","uri":"\/docs\/results\/images\/2011-02\/45542.jpg","mimetype":"image\/jpeg","size":"0","copyright":"\u00a9 Shutterstock","contenttype":"webItem","attributes":{"represents":"article","source":"editorial","type":"relatedImage"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"relatedArticle"}},{"rcn":"87801","title":"FP7-ENERGY-2007-1-RTD","identifier":"FP7-ENERGY-2007-1-RTD","contenttype":"call","attributes":{"source":"corda","type":"relatedSubCall"}},{"availableLanguages":"en","rcn":"1923671","id":"999920039","vatNumber":"DE228282604","legalName":"GERMANISCHER LLOYD INDUSTRIAL SERVICES GMBH","shortName":"GLIS","address":{"street":"BROOKTORKAI 18","city":"Hamburg","postalCode":"20457","country":"DE","url":"http:\/\/www.dnvgl.com","geolocation":"53.544376792,9.9999810522"},"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"PRC","title":"Private for-profit entities (excluding Higher or Secondary Education Establishments)","displayCode":"\/Private for-profit entities (excluding Higher or Secondary Education Establishments)","attributes":{"classification":"organizationActivityType","type":"relatedOrganizationActivityType"}}],"regions":[{"name":"Hamburg","rcn":"221798400","nutsCode":"DE600","parents":{"name":"Hamburg\/Hamburg\/Germany","rcn":"221798440\/221801000\/221940264","nutsCode":"DE60\/DE6\/DE","euCode":"DE","isoCode":"DE"},"attributes":{"type":"relatedNutsCode"}},{"name":"Germany","rcn":"221940264","nutsCode":"DE","euCode":"DE","isoCode":"DE","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"ecContribution":"65146","source":"corda","type":"participant","terminated":"false","order":"6"}},{"availableLanguages":"en","rcn":"1907297","id":"999646014","vatNumber":"EL090072876","legalName":"CENTRE FOR RENEWABLE ENERGY SOURCES AND SAVING FONDATION","shortName":"CRES","address":{"street":"MARATHONOS 19TH KM","city":"PIKERMI","postalCode":"190 09","country":"EL","url":"http:\/\/www.cres.gr","geolocation":"38.9953683,21.9877132"},"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"REC","title":"Research Organisations","displayCode":"\/Research Organisations","attributes":{"classification":"organizationActivityType","type":"relatedOrganizationActivityType"}}],"regions":[{"name":"\u0391\u03bd\u03b1\u03c4\u03bf\u03bb\u03b9\u03ba\u03ae \u0391\u03c4\u03c4\u03b9\u03ba\u03ae","rcn":"1465349","nutsCode":"EL305","parents":{"name":"A\u03c4\u03c4\u03b9\u03ba\u03ae\/\u0391\u03c4\u03c4\u03b9\u03ba\u03ae \/Greece","rcn":"1464908\/1464907\/240552488","nutsCode":"EL30\/EL3\/EL","euCode":"EL","isoCode":"EL"},"attributes":{"type":"relatedNutsCode"}},{"name":"Greece","rcn":"240552488","nutsCode":"EL","euCode":"EL","isoCode":"EL","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"ecContribution":"314020","source":"corda","type":"participant","terminated":"false","order":"3"}},{"availableLanguages":"en","rcn":"2117287","id":"996564227","legalName":"Suzlon Energy GmbH","shortName":"SUZLON","address":{"street":"August-Bebel-Stra\u00dfe 10","city":"Rostock","postalCode":"18055","country":"DE","url":"http:\/\/www.suzlon.de"},"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"PRC","title":"Private for-profit entities (excluding Higher or Secondary Education Establishments)","displayCode":"\/Private for-profit entities (excluding Higher or Secondary Education Establishments)","attributes":{"classification":"organizationActivityType","type":"relatedOrganizationActivityType"}}],"regions":[{"name":"Germany","rcn":"221940264","nutsCode":"DE","euCode":"DE","isoCode":"DE","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"ecContribution":"179125","source":"corda","type":"participant","terminated":"false","order":"8"}},{"availableLanguages":"en","rcn":"1905886","id":"999988715","vatNumber":"NL001752625B01","legalName":"NRG PALLAS BV","address":{"street":"WESTERDUINWEG  3","city":"Petten","postalCode":"1755 LE","country":"NL","url":"http:\/\/www.ecn.nl","geolocation":"52.76667,4.66111"},"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"PRC","title":"Private for-profit entities (excluding Higher or Secondary Education Establishments)","displayCode":"\/Private for-profit entities (excluding Higher or Secondary Education Establishments)","attributes":{"classification":"organizationActivityType","type":"relatedOrganizationActivityType"}}],"regions":[{"name":"Kop van Noord-Holland","rcn":"391393409","nutsCode":"NL321","parents":{"name":"Noord-Holland\/West-Nederland\/Netherlands","rcn":"391393448\/391395880\/391547432","nutsCode":"NL32\/NL3\/NL","euCode":"NL","isoCode":"NL"},"attributes":{"type":"relatedNutsCode"}},{"name":"Netherlands","rcn":"391547432","nutsCode":"NL","euCode":"NL","isoCode":"NL","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"ecContribution":"912152","source":"corda","type":"coordinator","terminated":"false","order":"1"}},{"availableLanguages":"en","rcn":"1905614","id":"999974747","vatNumber":"DE147794196","legalName":"UNIVERSITY OF STUTTGART","shortName":"USTUTT","address":{"street":"KEPLERSTRASSE 7","city":"Stuttgart","postalCode":"70174","country":"DE","url":"http:\/\/www.uni-stuttgart.de","geolocation":"48.781548989,9.1747319741"},"departmentName":["High Performance Computing Centre Stuttgart"],"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"HES","title":"Higher or Secondary Education Establishments","displayCode":"\/Higher or Secondary Education Establishments","attributes":{"classification":"organizationActivityType","type":"relatedOrganizationActivityType"}}],"regions":[{"name":"Stuttgart, Stadtkreis","rcn":"221777985","nutsCode":"DE111","parents":{"name":"Stuttgart\/Baden-W\u00fcrttemberg\/Germany","rcn":"221778024\/221780520\/221940264","nutsCode":"DE11\/DE1\/DE","euCode":"DE","isoCode":"DE"},"attributes":{"type":"relatedNutsCode"}},{"name":"Germany","rcn":"221940264","nutsCode":"DE","euCode":"DE","isoCode":"DE","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"ecContribution":"215168","source":"corda","type":"participant","terminated":"false","order":"7"}},{"availableLanguages":"en","rcn":"2117286","id":"999955153","vatNumber":"BE0403646296","legalName":"ZF WIND POWER ANTWERPEN NV","shortName":"ZF WPA","address":{"street":"GERARD MERCATORSTRAAT 40","city":"LOMMEL","postalCode":"3920","country":"BE","url":"http:\/\/www.hansentransmissions.com\/","geolocation":"51.2096939,5.264658122474955"},"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"PRC","title":"Private for-profit entities (excluding Higher or Secondary Education Establishments)","displayCode":"\/Private for-profit entities (excluding Higher or Secondary Education Establishments)","attributes":{"classification":"organizationActivityType","type":"relatedOrganizationActivityType"}}],"regions":[{"name":"Arr. Maaseik","rcn":"1464814","nutsCode":"BE225","parents":{"name":"Prov. Limburg (BE)\/Vlaams Gewest\/Belgium","rcn":"188227752\/188230184\/188385832","nutsCode":"BE22\/BE2\/BE","euCode":"BE","isoCode":"BE"},"attributes":{"type":"relatedNutsCode"}},{"name":"Belgium","rcn":"188385832","nutsCode":"BE","euCode":"BE","isoCode":"BE","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"ecContribution":"148526","source":"corda","type":"participant","terminated":"false","order":"4"}},{"availableLanguages":"en","rcn":"2117283","id":"999691701","vatNumber":"DE117895432","legalName":"UL INTERNATIONAL GMBH","address":{"street":"EBERTSTRASSE 96","city":"Wilhelmshaven","postalCode":"26382","country":"DE","url":"http:\/\/www.dewi.de","geolocation":"53.5186841,8.0973615"},"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"PRC","title":"Private for-profit entities (excluding Higher or Secondary Education Establishments)","displayCode":"\/Private for-profit entities (excluding Higher or Secondary Education Establishments)","attributes":{"classification":"organizationActivityType","type":"relatedOrganizationActivityType"}}],"regions":[{"name":"Wilhelmshaven, Kreisfreie Stadt","rcn":"221810949","nutsCode":"DE945","parents":{"name":"Weser-Ems\/Niedersachsen\/Germany","rcn":"221810984\/221813288\/221940264","nutsCode":"DE94\/DE9\/DE","euCode":"DE","isoCode":"DE"},"attributes":{"type":"relatedNutsCode"}},{"name":"Germany","rcn":"221940264","nutsCode":"DE","euCode":"DE","isoCode":"DE","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"ecContribution":"145982","source":"corda","type":"participant","terminated":"false","order":"2"}},{"availableLanguages":"de,en,es,fr,it,pl","rcn":"856","id":"FP7-ENERGY","code":"FP7-ENERGY","frameworkProgramme":"FP7","pga":"FP7-ENERGY","title":"Specific Programme \u0022Cooperation\u0022: Energy","shortTitle":"Energy","parent":{"rcn":"846\/1401\/837","code":"FP7-COOPERATION\/EC\/FP7"},"archivedDate":"2024-06-12 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"legalbasis","title":"Legal Basis","description":"Programme: Legal basis for research funding","displayCode":"\/Legal Basis","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedLegalBasis"}},{"availableLanguages":"en","rcn":"10953","id":"FP7_ENERGY-2007-2.3-03","code":"ENERGY-2007-2.3-03","frameworkProgramme":"FP7","title":"Testing, standards and certification for wind energy systems","parent":{"rcn":"10104\/10102\/10962\/856\/846\/1401\/837","code":"ENERGY-2.3\/ENERGY-2\/ENERGY\/FP7-ENERGY\/FP7-COOPERATION\/EC\/FP7"},"archivedDate":"2024-06-14 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"topic","title":"Topic","description":"Programme: Part of the Commission work programme implementing legal basis","displayCode":"\/Topic","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedTopic"}},{"availableLanguages":"en","rcn":"46605","id":"212825_46605_PS","title":"Periodic Report Summary 2 - PROTEST (PROcedures for testing and measuring wind energy systems)","teaser":"Currently the analyses and measurements performed on wind turbine prototypes, are rather detailed when looking at the blades and tower, but the mechanical components such as the pitch system, the yaw system and the drive train are not up to those standards. The fact that these...","sourceUpdateDate":"2017-02-16 13:15:20","contentUpdateDate":"2011-03-29 00:02:53","archivedDate":"2024-06-23 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"pubsum","title":"Report Summary","description":"Result: Publishable summary (FP7 SESAM) and Summary for publication (H2020 SyGMa)","displayCode":"\/Report Summary","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"sesam","title":"SESAM","description":"RTD FP7 reporting system (including FP6 Marie Curie)","displayCode":"\/SESAM","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"3115674","legalName":"STICHTING ENERGIEONDERZOEK CENTRUM NEDERLAND","address":{"city":"PETTEN","country":"NL"},"relations":{"regions":[{"name":"Netherlands","rcn":"391547432","nutsCode":"NL","euCode":"NL","isoCode":"NL","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"sesam","type":"relatedOrganization"}},{"language":"en","availableLanguages":"en","uri":"\/docs\/results\/212\/212825\/119922251-6.pdf","title":"Periodic Report 2 - PROTEST (PROcedures for testing and measuring wind energy systems)","size":"27600","description":"The PROTEST project was a European funded project within the Seventh Framework Programme (FP7) which led in some first suggestions to improve the standards concerning the wind turbine prototype testing focusing on the mechanical components. \n\n A major weak point in the former approach that had been adopted was that the aero-elastic tools did not include the necessary information about the mechanical components. For this reason three cases have been identified which needed further simulations to improve the current standards. These are the cases of low voltage ride through and an electrical fault in the grid may have a large impact on the loads of turbine. Though electrical faults were included in those standards, the simulating tools were not able to simulate these cases sufficiently. The possibility of resonance concerning the gearbox should be investigated in different frequency ranges. And finally, considering the possible misalignment in the drive train, simulations should be performed including the maximum allowed misalignment. \n\n A description concerning the loads that should be provided to the component manufacturer was given to answer the question of how loads could be communicated between the component manufacturer and the wind turbine manufacturer. \n\n The results of the project include a flexible approach that can be adopted to set up and use a prototype measurement campaign to validate the model and possibly improve the model characteristics. As the mechanical components buildup varies widely in wind turbines while at the same time the models available vary, as well, it was concluded that only a flexible method would be useful.","contenttype":"webItem","attributes":{"source":"undefined","type":"relatedResultAttachment"}}]},"contenttype":"result","attributes":{"source":"sesam","type":"relatedResult"}}],"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/67\/425\/1169\/1695","title":"wind energy","displayCode":"\/engineering and technology\/environmental engineering\/energy and fuels\/renewable energy\/wind energy","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"CP-FP","title":"Small or medium-scale focused research project","displayCode":"\/Small or medium-scale focused research project","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"modelVersion":"132","icaVersion":"19.1.0-ea6a1f3f"}