{"contenttype":"project","language":"en","availableLanguages":"en","rcn":"101297","id":"286601","acronym":"AQUALITY","teaser":"\u0022Currently the identification and quantification of pollutants in water are mostly carried out manually through sampling and subsequent laboratory analysis (off-line analysis), with methodologies of work that involve some significant costs in terms of displacement to sampling...","objective":"\u0022Currently the identification and quantification of pollutants in water are mostly carried out manually through sampling and subsequent laboratory analysis (off-line analysis), with methodologies of work that involve some significant costs in terms of displacement to sampling points, reagents and specialized personnel dedicated to the operation, leading to time consuming and economically challenging approaches, causing the number of analyses performed to be kept at the bare minimum. The industry therefore is calling for novel, cost-effective solutions to meet these new challenges: we propose to develop an online water monitoring device for microbiological contamination analysis, that allows industries and environmental protection agencies to replace the routine activities of sampling and laboratory testing of pathogens. The new system, which will be produced in two versions, both for online and for offline measurements, will be able to real time monitor the quality of industrial process water and effluents basing on an opto-ultrasonic device and on a lipid-based diagnostic kit. The novelty of our approach is the use of engineered liposomes for detecting bacteria in water: these are nanoparticles formed by a lipid bilayer enclosing an aqueous compartment displaying features that can be different (pH, ionic strength, composition) with respect to the bulk. We will load liposomes with a chromophore and will engineer them in order to make them specifically react with one target bacteria; this is the simple operating system of the AQUALITY system, which is completed by an ultrasonic unit to concentrate bacteria and an optical unit for detecting the sample colour change following to the interaction between liposomes and bacteria.\u0022","title":"On-line industrial water quality analysis system for rapid and accurate detection of pathogens","totalCost":"1508840","ecMaxContribution":"1128745","startDate":"2011-12-01","endDate":"2014-03-31","duration":"28","status":"CLOSED","validation":{"euroSciVoc":"false"},"contentCreationDate":"2011-11-25 00:00:00","contentUpdateDate":"2015-03-10 21:05:24","lastUpdateDate":"2026-02-18 16:58:45","archivedDate":"2024-06-18 00:00:00","relations":{"associations":[{"availableLanguages":"de,en,es,fr,it,pl","rcn":"36501","id":"36501-a-hightech-solution-for-detecting-bacteria-in-water","title":"A high-tech solution for detecting bacteria in water","teaser":"Water quality and safety can never be taken for granted. Every day, millions of tons of inadequately treated sewage, industrial and agricultural wastes are poured into the world\u0027s lakes, rivers, and oceans - the equivalent of the weight of the entire human population in the fo...","contentUpdateDate":"2014-03-26 00:00:02","archivedDate":"2023-03-23 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"news","title":"News","description":"Article: news","displayCode":"\/News","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"language":"en","availableLanguages":"en,any","uri":"\/docs\/news\/images\/2014-03\/20140326-1.jpg","mimetype":"image\/jpeg","size":"0","contenttype":"webItem","attributes":{"represents":"article","source":"editorial","type":"relatedImage"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"relatedArticle"}},{"availableLanguages":"de,en,es,fr,it,pl","rcn":"93000","id":"93000-realtime-water-monitoring","title":"Real-time water monitoring","teaser":"EU researchers have created and tested a prototype biosensor that can rapidly detect bacterial pathogens in water.","contentUpdateDate":"2014-04-10 15:54:58","archivedDate":"2024-06-10 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"health","title":"Health","displayCode":"\/Health","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"brief","title":"Result in Brief","description":"Article: Classic and enhanced","displayCode":"\/Result in Brief","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl,any","uri":"\/docs\/results\/images\/2014-04\/153528.jpg","mimetype":"image\/jpeg","size":"0","copyright":"\u00a9 Thinkstock","contenttype":"webItem","attributes":{"represents":"article","source":"editorial","type":"relatedImage"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"relatedArticle"}},{"rcn":"99924","title":"FP7-SME-2011","identifier":"FP7-SME-2011","contenttype":"call","attributes":{"source":"corda","type":"relatedSubCall"}},{"availableLanguages":"en","rcn":"1906084","id":"999418452","legalName":"TEKNOLOGISK INSTITUTT AS","shortName":"TI","address":{"street":"KABELGATEN 2","city":"OSLO","postalCode":"N-0580","country":"NO","url":"http:\/\/www.teknologisk.no"},"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"REC","title":"Research Organisations","displayCode":"\/Research Organisations","attributes":{"classification":"organizationActivityType","type":"relatedOrganizationActivityType"}}],"regions":[{"name":"Norway","rcn":"392333864","nutsCode":"NO","euCode":"NO","isoCode":"NO","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"participant","terminated":"false","order":"9"}},{"availableLanguages":"en","rcn":"1913789","id":"963126484","legalName":"IRBM SCIENCE PARK SRL","shortName":"IRBM","address":{"street":"VIA PONTINA KM 30.600","city":"POMEZIA","postalCode":"00040","country":"IT"},"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"PRC","title":"Private for-profit entities (excluding Higher or Secondary Education Establishments)","displayCode":"\/Private for-profit entities (excluding Higher or Secondary Education Establishments)","attributes":{"classification":"organizationActivityType","type":"relatedOrganizationActivityType"}}],"regions":[{"name":"Italy","rcn":"309758504","nutsCode":"IT","euCode":"IT","isoCode":"IT","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"participant","terminated":"true","order":"-3"}},{"availableLanguages":"en","rcn":"1913787","id":"996622912","vatNumber":"DE811194853","legalName":"ARGUS Umweltbiotechnologie GmbH","shortName":"ARGUS","address":{"street":"KITZINGSTRASSE 11-13","city":"Berlin","postalCode":"12277","country":"DE","url":"http:\/\/www.argus-umwelt.de","geolocation":"52.5170365,13.3888599"},"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"PRC","title":"Private for-profit entities (excluding Higher or Secondary Education Establishments)","displayCode":"\/Private for-profit entities (excluding Higher or Secondary Education Establishments)","attributes":{"classification":"organizationActivityType","type":"relatedOrganizationActivityType"}}],"regions":[{"name":"Berlin","rcn":"221786112","nutsCode":"DE300","parents":{"name":"Berlin\/Berlin\/Germany","rcn":"221786152\/221788712\/221940264","nutsCode":"DE30\/DE3\/DE","euCode":"DE","isoCode":"DE"},"attributes":{"type":"relatedNutsCode"}},{"name":"Germany","rcn":"221940264","nutsCode":"DE","euCode":"DE","isoCode":"DE","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"ecContribution":"258901.0","source":"corda","type":"participant","terminated":"false","order":"2"}},{"availableLanguages":"en","rcn":"1913784","id":"969476492","vatNumber":"ESB26219691","legalName":"ENSATEC SL","address":{"street":"AVENIDA LENTISCARES 4 6","city":"Navarrete","postalCode":"26370","country":"ES","url":"https:\/\/www.ensatec.com","geolocation":"42.4289697,-2.5616234"},"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"PRC","title":"Private for-profit entities (excluding Higher or Secondary Education Establishments)","displayCode":"\/Private for-profit entities (excluding Higher or Secondary Education Establishments)","attributes":{"classification":"organizationActivityType","type":"relatedOrganizationActivityType"}}],"regions":[{"name":"La Rioja","rcn":"242229440","nutsCode":"ES230","parents":{"name":"La Rioja\/Noreste\/Spain","rcn":"242229480\/242231848\/242387496","nutsCode":"ES23\/ES2\/ES","euCode":"ES","isoCode":"ES"},"attributes":{"type":"relatedNutsCode"}},{"name":"Spain","rcn":"242387496","nutsCode":"ES","euCode":"ES","isoCode":"ES","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"ecContribution":"350526.0","source":"corda","type":"coordinator","terminated":"false","order":"1"}},{"availableLanguages":"en","rcn":"1913791","id":"953004146","vatNumber":"IT10482601001","legalName":"IRBM SPA","shortName":"IRBM","address":{"street":"VIA PONTINA KM 30600","city":"POMEZIA RM","postalCode":"00040","country":"IT","geolocation":"41.90085,12.49035"},"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"PRC","title":"Private for-profit entities (excluding Higher or Secondary Education Establishments)","displayCode":"\/Private for-profit entities (excluding Higher or Secondary Education Establishments)","attributes":{"classification":"organizationActivityType","type":"relatedOrganizationActivityType"}}],"regions":[{"name":"Roma","rcn":"1464004","nutsCode":"ITI43","parents":{"name":"Lazio\/Centro (IT)\/Italy","rcn":"1465012\/1465008\/309758504","nutsCode":"ITI4\/ITI\/IT","euCode":"IT","isoCode":"IT"},"attributes":{"type":"relatedNutsCode"}},{"name":"Italy","rcn":"309758504","nutsCode":"IT","euCode":"IT","isoCode":"IT","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"ecContribution":"208738.0","source":"corda","type":"participant","terminated":"false","order":"3"}},{"availableLanguages":"en","rcn":"1913788","id":"999635344","legalName":"LABOR SRL","shortName":"LABOR","address":{"street":"VIA DELLA SCROFA 117","city":"ROMA","postalCode":"00186","country":"IT"},"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"PRC","title":"Private for-profit entities (excluding Higher or Secondary Education Establishments)","displayCode":"\/Private for-profit entities (excluding Higher or Secondary Education Establishments)","attributes":{"classification":"organizationActivityType","type":"relatedOrganizationActivityType"}}],"regions":[{"name":"Italy","rcn":"309758504","nutsCode":"IT","euCode":"IT","isoCode":"IT","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"participant","terminated":"false","order":"6"}},{"availableLanguages":"en","rcn":"1905609","id":"999979500","vatNumber":"IT02118311006","legalName":"CONSIGLIO NAZIONALE DELLE RICERCHE","shortName":"CNR","address":{"street":"PIAZZALE ALDO MORO 7","city":"Roma","postalCode":"00185","country":"IT","url":"http:\/\/www.cnr.it","geolocation":"41.900756621,12.512511598"},"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"REC","title":"Research Organisations","displayCode":"\/Research Organisations","attributes":{"classification":"organizationActivityType","type":"relatedOrganizationActivityType"}}],"regions":[{"name":"Roma","rcn":"1464004","nutsCode":"ITI43","parents":{"name":"Lazio\/Centro (IT)\/Italy","rcn":"1465012\/1465008\/309758504","nutsCode":"ITI4\/ITI\/IT","euCode":"IT","isoCode":"IT"},"attributes":{"type":"relatedNutsCode"}},{"name":"Italy","rcn":"309758504","nutsCode":"IT","euCode":"IT","isoCode":"IT","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"participant","terminated":"false","order":"7"}},{"availableLanguages":"en","rcn":"1913792","id":"985000469","vatNumber":"NO983973736MVA","legalName":"ROROSMEIERIET AS","shortName":"ROROS","address":{"street":"SOLLIHAGAEN   2","city":"ROROS","postalCode":"7374","country":"NO","url":"https:\/\/www.rorosmeieriet.no","geolocation":"62.5731625,11.372825"},"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"PRC","title":"Private for-profit entities (excluding Higher or Secondary Education Establishments)","displayCode":"\/Private for-profit entities (excluding Higher or Secondary Education Establishments)","attributes":{"classification":"organizationActivityType","type":"relatedOrganizationActivityType"}}],"regions":[{"name":"Tr\u00f8ndelag","rcn":"1465390","nutsCode":"NO060","parents":{"name":"Tr\u00f8ndelag\/Norge\/Norway","rcn":"1465041\/1465039\/392333864","nutsCode":"NO06\/NO0\/NO","euCode":"NO","isoCode":"NO"},"attributes":{"type":"relatedNutsCode"}},{"name":"Norway","rcn":"392333864","nutsCode":"NO","euCode":"NO","isoCode":"NO","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"ecContribution":"57359.0","source":"corda","type":"participant","terminated":"false","order":"5"}},{"availableLanguages":"en","rcn":"1913786","id":"992676079","legalName":"Optomesures","shortName":"OPTO","address":{"street":"enceinte Serres","city":"Saint Marcel Paulel","postalCode":"31590","country":"FR","url":"http:\/\/www.optomesures.fr"},"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"PRC","title":"Private for-profit entities (excluding Higher or Secondary Education Establishments)","displayCode":"\/Private for-profit entities (excluding Higher or Secondary Education Establishments)","attributes":{"classification":"organizationActivityType","type":"relatedOrganizationActivityType"}}],"regions":[{"name":"France","rcn":"258902568","nutsCode":"FR","euCode":"FR","isoCode":"FR","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"ecContribution":"253221.0","source":"corda","type":"participant","terminated":"false","order":"4"}},{"availableLanguages":"en","rcn":"1905627","id":"999975329","vatNumber":"GB568630414","legalName":"UNIVERSITY OF SOUTHAMPTON","shortName":"SOUTHAMPTON","address":{"street":"Highfield","city":"SOUTHAMPTON","postalCode":"SO17 1BJ","country":"UK","url":"http:\/\/www.southampton.ac.uk","geolocation":"51.51089,-0.08689"},"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"HES","title":"Higher or Secondary Education Establishments","displayCode":"\/Higher or Secondary Education Establishments","attributes":{"classification":"organizationActivityType","type":"relatedOrganizationActivityType"}}],"regions":[{"name":"Southampton","rcn":"508637378","nutsCode":"UKJ32","parents":{"name":"Hampshire and Isle of Wight\/South East (England)\/United Kingdom","rcn":"508637416\/508639784\/508725800","nutsCode":"UKJ3\/UKJ\/UK","euCode":"UK","isoCode":"GB"},"attributes":{"type":"relatedNutsCode"}},{"name":"United Kingdom","rcn":"508725800","nutsCode":"UK","euCode":"UK","isoCode":"GB","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"participant","terminated":"false","order":"10"}},{"availableLanguages":"en","rcn":"1907450","id":"999979694","vatNumber":"GB615860927","legalName":"CARDIFF UNIVERSITY","shortName":"CARDIFF UNIVERSITY","address":{"street":"RESEARCH SERVICES C\/O MAIN BUILDING","city":"CARDIFF","postalCode":"CF10 3AT","country":"UK","url":"http:\/\/www.cardiff.ac.uk","geolocation":"51.518098,-3.1179335"},"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"HES","title":"Higher or Secondary Education Establishments","displayCode":"\/Higher or Secondary Education Establishments","attributes":{"classification":"organizationActivityType","type":"relatedOrganizationActivityType"}}],"regions":[{"name":"Cardiff and Vale of Glamorgan","rcn":"508645506","nutsCode":"UKL22","parents":{"name":"East Wales\/Wales\/United Kingdom","rcn":"508645544\/508647976\/508725800","nutsCode":"UKL2\/UKL\/UK","euCode":"UK","isoCode":"GB"},"attributes":{"type":"relatedNutsCode"}},{"name":"United Kingdom","rcn":"508725800","nutsCode":"UK","euCode":"UK","isoCode":"GB","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"participant","terminated":"true","order":"8"}},{"availableLanguages":"de,en,es,fr,it,pl","rcn":"862","id":"FP7-SME","code":"FP7-SME","frameworkProgramme":"FP7","pga":"FP7-SME","title":"Specific Programme \u0022Capacities\u0022: Research for the benefit of SMEs","shortTitle":"Research for the benefit of SMEs","parent":{"rcn":"847\/1401\/837","code":"FP7-CAPACITIES\/EC\/FP7"},"archivedDate":"2024-06-12 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"legalbasis","title":"Legal Basis","description":"Programme: Legal basis for research funding","displayCode":"\/Legal Basis","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedLegalBasis"}},{"availableLanguages":"en","rcn":"15653","id":"FP7_SME-2011-1","code":"SME-2011-1","frameworkProgramme":"FP7","title":"Research for SMEs","parent":{"rcn":"10384\/11727\/862\/847\/1401\/837","code":"SME-1\/SME\/FP7-SME\/FP7-CAPACITIES\/EC\/FP7"},"archivedDate":"2024-06-14 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"topic","title":"Topic","description":"Programme: Part of the Commission work programme implementing legal basis","displayCode":"\/Topic","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedTopic"}},{"availableLanguages":"en","rcn":"153528","id":"286601_PS","title":"Final Report Summary - AQUALITY (On-line industrial water quality analysis system for rapid and accurate detection of pathogens)","teaser":"Executive Summary:Diseases caused by bacteria, viruses, fungi and other parasites are major causes of death, disability, and social and economic disruption for millions of people. Water is an important environmental source and agent for transmission of many of these pathogens...","sourceUpdateDate":"2017-02-17 17:29:42","contentUpdateDate":"2015-01-05 15:24:13","archivedDate":"2024-06-23 00:00:00","relations":{"associations":[{"availableLanguages":"de,en,es,fr,it,pl","rcn":"93000","title":"Real-time water monitoring","archivedDate":"2024-06-10 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"health","title":"Health","displayCode":"\/Health","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"brief","title":"Result in Brief","description":"Article: Classic and enhanced","displayCode":"\/Result in Brief","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"relatedArticle"}},{"availableLanguages":"en","rcn":"3124583","legalName":"ENSATEC SL","address":{"country":"ES"},"contenttype":"organization","attributes":{"source":"sesam","type":"relatedOrganization"}},{"language":"en","availableLanguages":"en,any","uri":"\/docs\/results\/286\/286601\/final1-section-1-executive-summary.pdf","mimetype":"application\/pdf","size":"48066","contenttype":"webItem","attributes":{"source":"sesam","type":"relatedResultAttachment"}}],"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"pubsum","title":"Report Summary","description":"Result: Publishable summary (FP7 SESAM) and Summary for publication (H2020 SyGMa)","displayCode":"\/Report Summary","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"sesam","title":"SESAM","description":"RTD FP7 reporting system (including FP6 Marie Curie)","displayCode":"\/SESAM","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"result","attributes":{"source":"sesam","type":"relatedResult"}},{"language":"en","availableLanguages":"en","defaultLanguage":"en","title":"Project website","id":"91a8de590ef709306a5faf0f260899ee","archivedDate":"2025-09-10 00:00:00","physUrl":"http:\/\/web.archive.org\/web\/20140305020231\/http:\/\/aquality-project.eu\/","status":"webArchive","contenttype":"webLink","attributes":{"represents":"project","source":"editorial","type":"relatedWebsite"}}],"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/47\/307\/979\/973\/1601","title":"operating systems","displayCode":"\/natural sciences\/computer and information sciences\/software\/software applications\/system software\/operating systems","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/63\/409","title":"colors","displayCode":"\/engineering and technology\/materials engineering\/colors","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/49\/341\/1035","title":"bacteriology","displayCode":"\/natural sciences\/biological sciences\/microbiology\/bacteriology","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/45\/287","title":"hydrology","displayCode":"\/natural sciences\/earth and related environmental sciences\/hydrology","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/69\/435","title":"nano-materials","displayCode":"\/engineering and technology\/nanotechnology\/nano-materials","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"BSG-SME","title":"Research for SMEs","displayCode":"\/Research for SMEs","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"modelVersion":"132","icaVersion":"20.0.0-48f81e07"}