{"contenttype":"project","language":"en","availableLanguages":"en","rcn":"196048","id":"661092","acronym":"STRETCHLENS","teaser":"A smart contact lens is a device in direct contact with the eye, having integrated electronic functionalities in order to improve the well-being of the user. In that respect, these devices are envisaged to address diverse complex aspects, such as providing augmented reality...","objective":"A smart contact lens is a device in direct contact with the eye, having integrated electronic functionalities in order to improve the well-being of the user. In that respect, these devices are envisaged to address diverse complex aspects, such as providing augmented reality, performing biomedical sensing and correcting or improving vision. For the first two application areas, possible approaches have already been demonstrated. However, the use of smart contact lenses to correct vision has only been recently proposed through the help of integrated liquid crystal (LC) cells. The integration of these LC cells in a contact lens is in particular appealing for ophthalmological disorders like iris perforation and presbyopia; the latter alone affecting more than 1 billion people. The STRETCHLENS platform envisages the hybrid integration of electro-optic capabilities (e.g. LC cells), RF transmission (e.g. antenna, ultra-thin Si chip - UTC), specific biomarker sensing (e.g. to identify some types of cancer cells) and thin-film based stretchable electrical interconnections. The platform, besides being stretchable due to the spherical shape of eye and manipulations during insertion\/extraction of the lens, will incorporate novel 3-D electrical interconnections which will allow for multilayer metallization to integrate UTC\u2019s, minimizing surface area and greatly improving miniaturization. Furthermore, the project will develop new knowledge through technological advancement and models of adhesion\/cohesion at the interface of hard\/soft composites, in order to predict delamination failures and optimize assemblies through design. The completion and development of such highly integrated stretchable systems will open up diverse research opportunities in the fields of biomaterial science, stretchable micromechanics, and autonomous biomedical and conformal electronics smart systems.","title":"Deformable platform with thin-film based circuits and ultra-thin Si chips for smart contact lens applications","totalCost":"160800","ecMaxContribution":"160800","startDate":"2016-09-01","endDate":"2018-08-31","ecSignatureDate":"2015-03-24","duration":"24","status":"CLOSED","identifiers":{"grantDoi":"10.3030\/661092"},"validation":{"euroSciVoc":"false"},"sourceUpdateDate":"2019-04-15 04:49:52","contentCreationDate":"2015-05-05 20:01:14","contentUpdateDate":"2022-08-09 19:28:15","lastUpdateDate":"2026-08-26 11:44:34","relations":{"associations":[{"rcn":"183","title":"H2020-MSCA-IF-2014","identifier":"H2020-MSCA-IF-2014","contenttype":"call","attributes":{"source":"corda","type":"relatedMasterCall"}},{"rcn":"183","title":"H2020-MSCA-IF-2014","identifier":"H2020-MSCA-IF-2014","contenttype":"call","attributes":{"source":"corda","type":"relatedSubCall"}},{"availableLanguages":"en","rcn":"1905930","id":"999981149","vatNumber":"BE0425260668","legalName":"INTERUNIVERSITAIR MICRO-ELECTRONICA CENTRUM","shortName":"IMEC","address":{"street":"KAPELDREEF 75","city":"Leuven","postalCode":"3001","country":"BE","url":"http:\/\/www.imec.be","geolocation":"50.865405118,4.6800449419"},"departmentName":["Business development \/ Public R\u0026D Policies and programs"],"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"REC","title":"Research Organisations","displayCode":"\/Research Organisations","attributes":{"classification":"organizationActivityType","type":"relatedOrganizationActivityType"}}],"regions":[{"name":"Arr. Leuven","rcn":"188227842","nutsCode":"BE242","parents":{"name":"Prov. Vlaams-Brabant\/Vlaams Gewest\/Belgium","rcn":"188227880\/188230184\/188385832","nutsCode":"BE24\/BE2\/BE","euCode":"BE","isoCode":"BE"},"attributes":{"type":"relatedNutsCode"}},{"name":"Belgium","rcn":"188385832","nutsCode":"BE","euCode":"BE","isoCode":"BE","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"ecContribution":"160800","sme":"false","source":"corda","type":"coordinator","netEcContribution":"160800","terminated":"false","totalCost":"160800","order":"1"}},{"availableLanguages":"en","rcn":"664546","id":"H2020_MSCA-IF-2014-EF","code":"MSCA-IF-2014-EF","frameworkProgramme":"H2020","title":"Marie Sk\u0142odowska-Curie Individual Fellowships (IF-EF)","parent":{"rcn":"20200","code":"H2020-Topics"},"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"topic","title":"Topic","description":"Programme: Part of the Commission work programme implementing legal basis","displayCode":"\/Topic","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedTopic"}},{"availableLanguages":"de,en,es,fr,it,pl","rcn":"664109","id":"H2020-EU.1.3.","code":"H2020-EU.1.3.","frameworkProgramme":"H2020","pga":"H2020-EU.1.3.","title":"EXCELLENT SCIENCE - Marie Sk\u0142odowska-Curie Actions","shortTitle":"Marie-Sklodowska-Curie Actions","parent":{"rcn":"664091\/664087\/664086","code":"H2020-EU.1.\/H2020-EC\/H2020"},"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"legalbasis","title":"Legal Basis","description":"Programme: Legal basis for research funding","displayCode":"\/Legal Basis","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedLegalBasis","uniqueProgrammePart":"true"}},{"availableLanguages":"de,en,es,fr,it,pl","rcn":"664113","id":"H2020-EU.1.3.2.","code":"H2020-EU.1.3.2.","frameworkProgramme":"H2020","pga":"H2020-EU.1.3.2.","title":"Nurturing excellence by means of cross-border and cross-sector mobility","shortTitle":"MSCA Mobility","parent":{"rcn":"664109\/664091\/664087\/664086","code":"H2020-EU.1.3.\/H2020-EU.1.\/H2020-EC\/H2020"},"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"legalbasis","title":"Legal Basis","description":"Programme: Legal basis for research funding","displayCode":"\/Legal Basis","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedLegalBasis"}},{"availableLanguages":"en","rcn":"531245","id":"661092_269354_PUBLI","title":"Simple multifocal lens based on liquid crystals","details":"\n    \u003Cauthors\u003EHerbert De Smet,\u00a0Xiaobing Shang,\u00a0Celine Vanhaverbeke\u00a0and\u00a0Andr\u00e9s Felipe Vasquez Quintero\u003C\/authors\u003E\n    \u003CjournalTitle\u003EEuroDisplay\u003C\/journalTitle\u003E\n    \u003CjournalNumber\u003EEvery year\u003C\/journalNumber\u003E\n    \u003Cpublisher\u003EEuroDisplay\u003C\/publisher\u003E\n    \u003CpublishedYear\u003E2017\u003C\/publishedYear\u003E\n    \u003CpublishedPages\u003E\u003C\/publishedPages\u003E\n","sourceUpdateDate":"2020-08-15 23:38:30","contentUpdateDate":"2020-09-10 11:38:05","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"publication","title":"Project publication","description":"Result: Project publications","displayCode":"\/Project publication","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"CONFERENCE_PROCEEDING","title":"Conference proceedings","displayCode":"\/Conference proceedings","attributes":{"classification":"projectPublication","type":"isPublishedAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"531246","id":"661092_269355_PUBLI","title":"Fabrication of fixed-shape soft smart objects by thermoplastic forming of flat stretchable circuits","details":"\n    \u003Cauthors\u003EAndr\u00e9s Felipe Vasquez Quintero,\u00a0Jan Vanfleteren,\u00a0Frederick Bossuyt,\u00a0Bart Plovie,\u00a0Rik Verplancke\u00a0and\u00a0Herbert De Smet\u003C\/authors\u003E\n    \u003CjournalTitle\u003EMaterials Research Society\u003C\/journalTitle\u003E\n    \u003CjournalNumber\u003EEvery 6 months\u003C\/journalNumber\u003E\n    \u003Cpublisher\u003EMRS\u003C\/publisher\u003E\n    \u003CpublishedYear\u003E2017\u003C\/publishedYear\u003E\n    \u003CpublishedPages\u003E\u003C\/publishedPages\u003E\n","sourceUpdateDate":"2020-08-15 23:38:30","contentUpdateDate":"2020-09-10 11:38:05","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"publication","title":"Project publication","description":"Result: Project publications","displayCode":"\/Project publication","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"CONFERENCE_PROCEEDING","title":"Conference proceedings","displayCode":"\/Conference proceedings","attributes":{"classification":"projectPublication","type":"isPublishedAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"531247","id":"661092_269356_PUBLI","title":"Stretchable Electronic Platform for Soft and Smart Contact Lens Applications","details":"\n    \u003Cauthors\u003EAndr\u00e9s V\u00e1squez Quintero, Rik Verplancke, Herbert De Smet, Jan Vanfleteren\u003C\/authors\u003E\n    \u003CjournalTitle\u003EAdvanced Materials Technologies\u003C\/journalTitle\u003E\n    \u003CjournalNumber\u003E2\/8\u003C\/journalNumber\u003E\n    \u003Cpublisher\u003Ehttps:\/\/explore.openaire.eu\/search\/project?projectId=corda__h2020::0c702f3bd3a4707269813a895a1bd543\u003C\/publisher\u003E\n    \u003CpublishedYear\u003E2017\u003C\/publishedYear\u003E\n    \u003CpublishedPages\u003E1700073\u003C\/publishedPages\u003E\n","identifiers":{"doi":"10.1002\/admt.201700073","issn":["2365-709X"]},"sourceUpdateDate":"2020-08-15 23:38:30","contentUpdateDate":"2020-09-10 11:38:05","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"publication","title":"Project publication","description":"Result: Project publications","displayCode":"\/Project publication","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"PEER_REVIEWED_ARTICLE","title":"Peer reviewed articles","displayCode":"\/Peer reviewed articles","attributes":{"classification":"projectPublication","type":"isPublishedAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"531248","id":"661092_269571_PUBLI","title":"Optimization of thermoformed displays for smart contact lenses","details":"\n    \u003Cauthors\u003ECeline Vanhaverbeke,\u00a0Andr\u00e9s Felipe Vasquez Quintero,\u00a0Lucas Oorlynck,\u00a0Xiaobing Shang\u00a0and\u00a0Herbert De Smet\u003C\/authors\u003E\n    \u003CjournalTitle\u003EEuroDisplay\u003C\/journalTitle\u003E\n    \u003CjournalNumber\u003EEvery year\u003C\/journalNumber\u003E\n    \u003Cpublisher\u003EEuroDisplay\u003C\/publisher\u003E\n    \u003CpublishedYear\u003E2017\u003C\/publishedYear\u003E\n    \u003CpublishedPages\u003E\u003C\/publishedPages\u003E\n","sourceUpdateDate":"2020-08-15 23:38:30","contentUpdateDate":"2020-09-10 11:38:05","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"publication","title":"Project publication","description":"Result: Project publications","displayCode":"\/Project publication","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"CONFERENCE_PROCEEDING","title":"Conference proceedings","displayCode":"\/Conference proceedings","attributes":{"classification":"projectPublication","type":"isPublishedAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"531249","id":"661092_269573_PUBLI","title":"Stretchable electronic platform for soft and smart contact lens applications","details":"\n    \u003Cauthors\u003EAndr\u00e9s Felipe Vasquez Quintero,\u00a0Rik Verplancke,\u00a0Jelle De Smet,\u00a0Herbert De Smet\u00a0and\u00a0Jan Vanfleteren\u003C\/authors\u003E\n    \u003CjournalTitle\u003EMaterials Research Society\u003C\/journalTitle\u003E\n    \u003CjournalNumber\u003EEvery 6 months\u003C\/journalNumber\u003E\n    \u003Cpublisher\u003EMRS\u003C\/publisher\u003E\n    \u003CpublishedYear\u003E2016\u003C\/publishedYear\u003E\n    \u003CpublishedPages\u003E\u003C\/publishedPages\u003E\n","sourceUpdateDate":"2020-08-15 23:38:30","contentUpdateDate":"2020-09-10 11:38:05","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"publication","title":"Project publication","description":"Result: Project publications","displayCode":"\/Project publication","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"CONFERENCE_PROCEEDING","title":"Conference proceedings","displayCode":"\/Conference proceedings","attributes":{"classification":"projectPublication","type":"isPublishedAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"531250","id":"661092_269574_PUBLI","title":"Thin and spherical-cap-shaped LCD with a flexible thin-film driver for use in a smart contact lens","details":"\n    \u003Cauthors\u003EHerbert De Smet, Andres Felipe Vasquez Quintero, et al.\u003C\/authors\u003E\n    \u003CjournalTitle\u003ESociety of Information Display\u003C\/journalTitle\u003E\n    \u003CjournalNumber\u003EEvery year\u003C\/journalNumber\u003E\n    \u003Cpublisher\u003ESID Mid-Europe\u003C\/publisher\u003E\n    \u003CpublishedYear\u003E2017\u003C\/publishedYear\u003E\n    \u003CpublishedPages\u003E\u003C\/publishedPages\u003E\n","sourceUpdateDate":"2020-08-15 23:38:30","contentUpdateDate":"2020-09-10 11:38:05","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"publication","title":"Project publication","description":"Result: Project publications","displayCode":"\/Project publication","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"CONFERENCE_PROCEEDING","title":"Conference proceedings","displayCode":"\/Conference proceedings","attributes":{"classification":"projectPublication","type":"isPublishedAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"531251","id":"661092_269575_PUBLI","title":"Smart Contact Lens Platform with a Deformed Active Artificial Iris","details":"\n    \u003Cauthors\u003EAndr\u00e9s Felipe Vasquez Quintero,\u00a0Simon Delcour,\u00a0Rik Verplancke,\u00a0Herbert De Smet\u00a0and\u00a0Jan Vanfleteren\u003C\/authors\u003E\n    \u003CjournalTitle\u003EInternational Display Workshop\u003C\/journalTitle\u003E\n    \u003CjournalNumber\u003EEvery year\u003C\/journalNumber\u003E\n    \u003Cpublisher\u003EIDW\u003C\/publisher\u003E\n    \u003CpublishedYear\u003E2016\u003C\/publishedYear\u003E\n    \u003CpublishedPages\u003E\u003C\/publishedPages\u003E\n","sourceUpdateDate":"2020-08-15 23:38:30","contentUpdateDate":"2020-09-10 11:38:05","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"publication","title":"Project publication","description":"Result: Project publications","displayCode":"\/Project publication","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"CONFERENCE_PROCEEDING","title":"Conference proceedings","displayCode":"\/Conference proceedings","attributes":{"classification":"projectPublication","type":"isPublishedAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"531252","id":"661092_269576_PUBLI","title":"Stretchable platform enabled with wireless power for smart contact lenses","details":"\n    \u003Cauthors\u003EAndr\u00e9s Felipe Vasquez Quintero,\u00a0Rik Verplancke,\u00a0Herbert De Smet\u00a0and\u00a0Jan Vanfleteren\u003C\/authors\u003E\n    \u003CjournalTitle\u003EMaterials Research Society\u003C\/journalTitle\u003E\n    \u003CjournalNumber\u003EEvery 6 months\u003C\/journalNumber\u003E\n    \u003Cpublisher\u003EMRS\u003C\/publisher\u003E\n    \u003CpublishedYear\u003E2017\u003C\/publishedYear\u003E\n    \u003CpublishedPages\u003E\u003C\/publishedPages\u003E\n","sourceUpdateDate":"2020-08-15 23:38:30","contentUpdateDate":"2020-09-10 11:38:05","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"publication","title":"Project publication","description":"Result: Project publications","displayCode":"\/Project publication","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"CONFERENCE_PROCEEDING","title":"Conference proceedings","displayCode":"\/Conference proceedings","attributes":{"classification":"projectPublication","type":"isPublishedAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"251841","id":"661092_PS","title":"Periodic Reporting for period 1 - STRETCHLENS (Deformable platform with thin-film based circuits and ultra-thin Si chips for smart contact lens applications)","teaser":"A smart contact lens is a medical device in direct contact with the eye, having integrated electronic functionalities in order to improve the well-being of the user. In that respect, these devices are envisaged to address diverse complex aspects, such as providing augmented...","description":"periodic","sourceUpdateDate":"2024-02-24 10:47:00","contentUpdateDate":"2024-11-06 10:17:19","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"pubsum","title":"Report Summary","description":"Result: Publishable summary (FP7 SESAM) and Summary for publication (H2020 SyGMa)","displayCode":"\/Report Summary","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"language":"en","availableLanguages":"en,any","uri":"\/docs\/results\/h2020\/661\/661092_PS\/figure-1.jpg","alternativeText":"Figure 1 shows the concept of the autonomous smart contact lens with its active components","mimetype":"image\/jpeg","size":"40960","contenttype":"webItem","attributes":{"source":"corda","type":"relatedResultAttachment"}},{"language":"en","availableLanguages":"en,any","uri":"\/docs\/results\/h2020\/661\/661092_PS\/figure-2.jpg","alternativeText":"Figure 2 shows pictures of the developed STRETCHLENS prototype supported by a soft contact lens.","mimetype":"image\/jpeg","size":"20480","contenttype":"webItem","attributes":{"source":"corda","type":"relatedResultAttachment"}},{"language":"en","availableLanguages":"en","defaultLanguage":"en","id":"f8de8d2d64eb4c2469810eea1f639027","archivedDate":"2025-06-20 00:00:00","physUrl":"https:\/\/www.ugent.be\/en\/research\/research-ugent\/trackrecord\/trackrecord-h2020\/msca-h2020\/msca-strechlens.htm","status":"invalid","contenttype":"webLink","attributes":{"represents":"project","source":"corda","type":"relatedWebsite"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"language":"en","availableLanguages":"en","defaultLanguage":"en","title":"Project website","id":"4da851c55eaa863d84dd3cb309fd84b4","archivedDate":"2026-08-18 00:00:00","physUrl":"https:\/\/web.archive.org\/web\/20180815145955\/https:\/\/www.ugent.be\/en\/research\/research-ugent\/trackrecord\/trackrecord-h2020\/msca-h2020\/msca-strechlens.htm","status":"webArchive","contenttype":"webLink","attributes":{"represents":"project","source":"editorial","type":"relatedWebsite"}},{"language":"en","availableLanguages":"en","defaultLanguage":"en","title":"Smart contact has potential to improve sight for many","id":"f9b2c4bb7a6135d249da1021911bd3c8","physUrl":"https:\/\/ec.europa.eu\/research-and-innovation\/en\/projects\/success-stories\/all\/smart-contact-has-potential-improve-sight-many","contenttype":"webLink","attributes":{"represents":"project","source":"editorial","type":"relatedStory"}}],"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/63\/403","title":"liquid crystals","displayCode":"\/engineering and technology\/materials engineering\/liquid crystals","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"MSCA-IF-EF-ST","title":"Standard EF","description":"Standard EF","displayCode":"\/Standard EF","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"modelVersion":"132","icaVersion":"20.0.0-48f81e07"}