{"contenttype":"project","language":"en","availableLanguages":"en","rcn":"209913","id":"724244","acronym":"eAXON","teaser":"To build interfaces between the electronic domain and the human nervous system is one of the most demanding challenges of nowadays engineering. Fascinating developments have already been performed such as visual cortical implants for the blind and cochlear implants for the...","objective":"To build interfaces between the electronic domain and the human nervous system is one of the most demanding challenges of nowadays engineering. Fascinating developments have already been performed such as visual cortical implants for the blind and cochlear implants for the deaf. Yet implantation of most electrical stimulation systems requires complex surgeries which hamper their use for the development of so-called electroceuticals. More importantly, previously developed systems based on central stimulation units are not adequate for applications in which a large number of sites must be individually stimulated over large and mobile body parts, thus hindering neuroprosthetic solutions for patients suffering paralysis due to spinal cord injury or other neurological disorders. A solution to these challenges could consist in developing addressable single-channel wireless microstimulators which could be implanted with simple procedures such as injection. And, indeed, such solution was proposed and tried in the past. However, previous attempts did not achieve satisfactory success because the developed implants were stiff and too large. Further miniaturization was prevented because of the use of inductive coupling and batteries as energy sources. Here I propose to explore an innovative method for performing electrical stimulation in which the implanted microstimulators will operate as rectifiers of bursts of innocuous high frequency current supplied through skin electrodes shaped as garments. This approach has the potential to reduce the diameter of the implants to one-fifth the diameter of current microstimulators and, more significantly, to allow that most of the implants\u2019 volume consists of materials whose density and flexibility match those of neighbouring living tissues for minimizing invasiveness. In fact, implants based on the proposed method will look like short pieces of flexible thread.","title":"Electronic AXONs: wireless microstimulators based on electronic rectification of epidermically applied currents","keywords":"Biomedical electronics, biomedical engineering, biomedical implants, electrical stimulation,  neuroprosthetics, rectifiers, minimal invasiveness, electroceuticals, paralysis, neuropathic pain","totalCost":"1999813","ecMaxContribution":"1999813","startDate":"2017-05-01","endDate":"2023-04-30","ecSignatureDate":"2017-04-10","duration":"72","status":"CLOSED","identifiers":{"grantDoi":"10.3030\/724244"},"validation":{"euroSciVoc":"false"},"sourceUpdateDate":"2023-09-04 19:53:28","contentCreationDate":"2017-04-20 15:51:25","contentUpdateDate":"2024-09-06 17:40:11","lastUpdateDate":"2026-02-18 16:58:45","relations":{"associations":[{"rcn":"33046","title":"ERC-2016-COG","identifier":"ERC-2016-COG","contenttype":"call","attributes":{"source":"corda","type":"relatedSubCall"}},{"rcn":"33046","title":"ERC-2016-COG","identifier":"ERC-2016-COG","contenttype":"call","attributes":{"source":"corda","type":"relatedMasterCall"}},{"availableLanguages":"en","rcn":"1905555","id":"999867077","vatNumber":"ESQ5850017D","legalName":"UNIVERSIDAD POMPEU FABRA","shortName":"UPF","address":{"street":"PLACA DE LA MERCE, 10-12","city":"Barcelona","postalCode":"08002","country":"ES","url":"http:\/\/www.upf.edu","geolocation":"41.379074134,2.1795478753"},"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"HES","title":"Higher or Secondary Education Establishments","displayCode":"\/Higher or Secondary Education Establishments","attributes":{"classification":"organizationActivityType","type":"relatedOrganizationActivityType"}}],"regions":[{"name":"Barcelona","rcn":"242241601","nutsCode":"ES511","parents":{"name":"Catalu\u00f1a\/Este\/Spain","rcn":"242241640\/242244136\/242387496","nutsCode":"ES51\/ES5\/ES","euCode":"ES","isoCode":"ES"},"attributes":{"type":"relatedNutsCode"}},{"name":"Spain","rcn":"242387496","nutsCode":"ES","euCode":"ES","isoCode":"ES","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"ecContribution":"1999813","sme":"false","source":"corda","type":"coordinator","netEcContribution":"1999813","terminated":"false","totalCost":"1999813","order":"1"}},{"availableLanguages":"de,en,es,fr,it,pl","rcn":"664099","id":"H2020-EU.1.1.","code":"H2020-EU.1.1.","frameworkProgramme":"H2020","pga":"H2020-EU.1.1.","title":"EXCELLENT SCIENCE - European Research Council (ERC)","shortTitle":"European Research Council (ERC)","parent":{"rcn":"664091\/664087\/664086","code":"H2020-EU.1.\/H2020-EC\/H2020"},"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"legalbasis","title":"Legal Basis","description":"Programme: Legal basis for research funding","displayCode":"\/Legal Basis","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedLegalBasis","uniqueProgrammePart":"true"}},{"availableLanguages":"en","rcn":"700800","id":"H2020_ERC-2016-COG","code":"ERC-2016-COG","frameworkProgramme":"H2020","title":"ERC Consolidator Grant","parent":{"rcn":"20200","code":"H2020-Topics"},"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"topic","title":"Topic","description":"Programme: Part of the Commission work programme implementing legal basis","displayCode":"\/Topic","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedTopic"}},{"availableLanguages":"en","rcn":"941439","id":"724244_1808707_PUBLI","title":"Floating EMG sensors and stimulators wirelessly powered and operated by volume conduction for networked neuroprosthetics","details":"\r\n    \u003Cauthors\u003ELaura Becerra-Fajardo; Marc Oliver Krob; Jesus Minguillon; Camila Rodrigues; Christine Welsch; Marc Tudela-Pi; Albert Comerma; Filipe Oliveira Barroso; Andreas Schneider; Antoni Ivorra\u003C\/authors\u003E\r\n    \u003CjournalNumber\u003E5\u003C\/journalNumber\u003E\r\n    \u003CjournalTitle\u003EJournal of NeuroEngineering and Rehabilitation\u003C\/journalTitle\u003E\r\n    \u003CpublishedPages \/\u003E\r\n    \u003CpublishedYear\u003E2022\u003C\/publishedYear\u003E\r\n    \u003Cpublisher\u003EBioMed Central\u003C\/publisher\u003E\r\n  ","identifiers":{"doi":"10.1186\/s12984-022-01033-3","issn":["1743-0003"]},"sourceUpdateDate":"2023-06-05 22:00:44","contentUpdateDate":"2023-06-14 17:03:16","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"publication","title":"Project publication","description":"Result: Project publications","displayCode":"\/Project publication","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"PEER_REVIEWED_ARTICLE","title":"Peer reviewed articles","displayCode":"\/Peer reviewed articles","attributes":{"classification":"projectPublication","type":"isPublishedAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"941438","id":"724244_1808756_PUBLI","title":"Injectable temperature sensors based on passive rectification of volume-conducted currents","details":"\r\n    \u003Cauthors\u003ELaura Becerra-Fajardo; Aracelys Garcia-Moreno; Nerea Alvarez De Eulate Llano; Antoni Ivorra\u003C\/authors\u003E\r\n    \u003CjournalNumber \/\u003E\r\n    \u003CjournalTitle\u003E2021 IEEE Biomedical Circuits and Systems Conference (BioCAS)\u003C\/journalTitle\u003E\r\n    \u003CpublishedPages \/\u003E\r\n    \u003CpublishedYear\u003E2021\u003C\/publishedYear\u003E\r\n    \u003Cpublisher\u003EIEEE\u003C\/publisher\u003E\r\n  ","identifiers":{"doi":"10.1109\/biocas49922.2021.9645006"},"sourceUpdateDate":"2023-06-05 22:00:44","contentUpdateDate":"2023-06-14 17:03:16","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"publication","title":"Project publication","description":"Result: Project publications","displayCode":"\/Project publication","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"CONFERENCE_PROCEEDING","title":"Conference proceedings","displayCode":"\/Conference proceedings","attributes":{"classification":"projectPublication","type":"isPublishedAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"944510","id":"724244_1811926_PUBLI","title":"Networks of Injectable Microdevices Powered and Digitally Linked by Volume Conduction for Neuroprosthetics: a Proof-of-Concept","details":"\r\n    \u003Cauthors\u003ELaura Becerra-Fajardo; Jesus Minguillon; Albert Comerma; Antoni Ivorra\u003C\/authors\u003E\r\n    \u003CjournalNumber \/\u003E\r\n    \u003CjournalTitle\u003E2023 11th International IEEE\/EMBS Conference on Neural Engineering (NER)\u003C\/journalTitle\u003E\r\n    \u003CpublishedPages \/\u003E\r\n    \u003CpublishedYear\u003E2023\u003C\/publishedYear\u003E\r\n    \u003Cpublisher\u003EIEEE\u003C\/publisher\u003E\r\n  ","identifiers":{"doi":"10.1109\/ner52421.2023.10123743"},"sourceUpdateDate":"2023-06-09 10:30:00","contentUpdateDate":"2023-06-17 19:42:25","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"publication","title":"Project publication","description":"Result: Project publications","displayCode":"\/Project publication","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"CONFERENCE_PROCEEDING","title":"Conference proceedings","displayCode":"\/Conference proceedings","attributes":{"classification":"projectPublication","type":"isPublishedAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"478046","id":"724244_PS","title":"Periodic Reporting for period 4 - eAXON (Electronic AXONs: wireless microstimulators based on electronic rectification of epidermically applied currents)","teaser":"Building interfaces between the electronic domain and the human nervous system is one of the most demanding challenges of nowadays engineering. Fascinating developments have already been performed such as visual cortical implants for the blind and cochlear implants for the...","description":"periodic","sourceUpdateDate":"2024-02-24 10:47:00","contentUpdateDate":"2024-04-01 16:03:26","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"pubsum","title":"Report Summary","description":"Result: Publishable summary (FP7 SESAM) and Summary for publication (H2020 SyGMa)","displayCode":"\/Report Summary","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"language":"en","availableLanguages":"en,any","uri":"\/docs\/results\/h2020\/724\/724244_PS\/figure3.png","alternativeText":"X-ray image of five eAXONs implanted in a rabbit hindlimb","mimetype":"image\/png","size":"225280","contenttype":"webItem","attributes":{"source":"corda","type":"relatedResultAttachment"}},{"language":"en","availableLanguages":"en,any","uri":"\/docs\/results\/h2020\/724\/724244_PS\/figure1.png","alternativeText":"Graphical explanation of the eAXON method","mimetype":"image\/png","size":"442368","contenttype":"webItem","attributes":{"source":"corda","type":"relatedResultAttachment"}},{"language":"en","availableLanguages":"en,any","uri":"\/docs\/results\/h2020\/724\/724244_PS\/figure2.png","alternativeText":"Picture and main parts of the eAXON implants","mimetype":"image\/png","size":"558080","contenttype":"webItem","attributes":{"source":"corda","type":"relatedResultAttachment"}},{"language":"en","availableLanguages":"en","defaultLanguage":"en","id":"c4d0b0416256064c5e1005dda32972bf","archivedDate":"2025-07-08 00:00:00","physUrl":"https:\/\/www.upf.edu\/web\/eaxon","status":"legacy","contenttype":"webLink","attributes":{"represents":"project","source":"corda","type":"relatedWebsite"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"742856","id":"724244_1122213_PUBLI","title":"Power Transfer by Volume Conduction: In Vitro Validated Analytical Models Predict DC Powers Above 1 mW in Injectable Implants","details":"\r\n    \u003Cauthors\u003EMarc Tudela-Pi, Laura Becerra-Fajardo, Aracelys Garcia-Moreno, Jesus Minguillon, Antoni Ivorra\u003C\/authors\u003E\r\n    \u003CjournalNumber\u003E8\u003C\/journalNumber\u003E\r\n    \u003CjournalTitle\u003EIEEE Access\u003C\/journalTitle\u003E\r\n    \u003CpublishedPages\u003E37808-37820\u003C\/publishedPages\u003E\r\n    \u003CpublishedYear\u003E2020\u003C\/publishedYear\u003E\r\n    \u003Cpublisher\u003EInstitute of Electrical and Electronics Engineers Inc.\u003C\/publisher\u003E\r\n  ","identifiers":{"doi":"10.1109\/access.2020.2975597","issn":["2169-3536"]},"sourceUpdateDate":"2021-08-14 07:41:11","contentUpdateDate":"2021-10-30 00:02:49","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"publication","title":"Project publication","description":"Result: Project publications","displayCode":"\/Project publication","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"PEER_REVIEWED_ARTICLE","title":"Peer reviewed articles","displayCode":"\/Peer reviewed articles","attributes":{"classification":"projectPublication","type":"isPublishedAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"590326","id":"724244_297874_PUBLI","title":"First Steps Towards an Implantable Electromyography (EMG) Sensor Powered and Controlled by Galvanic Coupling","details":"\n    \u003Cauthors\u003ELaura Becerra-Fajardo, Antoni Ivorra\u003C\/authors\u003E\n    \u003CjournalTitle\u003EWorld Congress on Medical Physics and Biomedical Engineering 2018\u003C\/journalTitle\u003E\n    \u003CjournalNumber\u003E68\/3\u003C\/journalNumber\u003E\n    \u003Cpublisher\u003ESpringer Singapore\u003C\/publisher\u003E\n    \u003CpublishedYear\u003E2019\u003C\/publishedYear\u003E\n    \u003CpublishedPages\u003E19-22\u003C\/publishedPages\u003E\n","identifiers":{"doi":"10.1007\/978-981-10-9023-3_4","isbn":"978-981-10-9022-6"},"sourceUpdateDate":"2020-08-15 23:38:30","contentUpdateDate":"2020-09-10 12:08:16","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"publication","title":"Project publication","description":"Result: Project publications","displayCode":"\/Project publication","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"BOOK_CHAPTER","title":"Book chapters","displayCode":"\/Book chapters","attributes":{"classification":"projectPublication","type":"isPublishedAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"590327","id":"724244_297875_PUBLI","title":"Powering Implants by Galvanic Coupling: A Validated Analytical Model Predicts Powers Above 1 mW in Injectable Implants","details":"\n    \u003Cauthors\u003EMarc Tudela-Pi, Laura Becerra-Fajardo, Antoni Ivorra\u003C\/authors\u003E\n    \u003CjournalTitle\u003EWorld Congress on Medical Physics and Biomedical Engineering 2018\u003C\/journalTitle\u003E\n    \u003CjournalNumber\u003E68\/3\u003C\/journalNumber\u003E\n    \u003Cpublisher\u003ESpringer Singapore\u003C\/publisher\u003E\n    \u003CpublishedYear\u003E2019\u003C\/publishedYear\u003E\n    \u003CpublishedPages\u003E23-26\u003C\/publishedPages\u003E\n","identifiers":{"doi":"10.1007\/978-981-10-9023-3_5","isbn":"978-981-10-9022-6"},"sourceUpdateDate":"2020-08-15 23:38:30","contentUpdateDate":"2020-09-10 12:08:16","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"publication","title":"Project publication","description":"Result: Project publications","displayCode":"\/Project publication","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"BOOK_CHAPTER","title":"Book chapters","displayCode":"\/Book chapters","attributes":{"classification":"projectPublication","type":"isPublishedAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"590328","id":"724244_575214_PUBLI","title":"Two-Port Networks to Model Galvanic Coupling for Intrabody Communications and Power Transfer to Implants","details":"\n    \u003Cauthors\u003ELaura Becerra-Fajardo, Marc Tudela-Pi, Antoni Ivorra\u003C\/authors\u003E\n    \u003CjournalTitle\u003E2018 IEEE Biomedical Circuits and Systems Conference (BioCAS)\u003C\/journalTitle\u003E\n    \u003CjournalNumber\u003E\u003C\/journalNumber\u003E\n    \u003Cpublisher\u003EIEEE\u003C\/publisher\u003E\n    \u003CpublishedYear\u003E2018\u003C\/publishedYear\u003E\n    \u003CpublishedPages\u003E1-4\u003C\/publishedPages\u003E\n","identifiers":{"doi":"10.1109\/biocas.2018.8584691","isbn":"978-1-5386-3603-9"},"sourceUpdateDate":"2020-08-15 23:38:30","contentUpdateDate":"2020-09-10 12:08:16","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"publication","title":"Project publication","description":"Result: Project publications","displayCode":"\/Project publication","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"CONFERENCE_PROCEEDING","title":"Conference proceedings","displayCode":"\/Conference proceedings","attributes":{"classification":"projectPublication","type":"isPublishedAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"742862","id":"724244_1122203_PUBLI","title":"Interleaved intramuscular stimulation with minimally overlapping electrodes evokes smooth and fatigue resistant forces","details":"\r\n    \u003Cauthors\u003EAhmed Eladly, Jaume Del Valle, Jesus Minguillon, Borja Mercadal, Laura Becerra-Fajardo, Xavier Navarro, Antoni Ivorra\u003C\/authors\u003E\r\n    \u003CjournalNumber\u003E17\/4\u003C\/journalNumber\u003E\r\n    \u003CjournalTitle\u003EJournal of Neural Engineering\u003C\/journalTitle\u003E\r\n    \u003CpublishedPages\u003E046037\u003C\/publishedPages\u003E\r\n    \u003CpublishedYear\u003E2020\u003C\/publishedYear\u003E\r\n    \u003Cpublisher\u003EInstitute of Physics\u003C\/publisher\u003E\r\n  ","identifiers":{"doi":"10.1088\/1741-2552\/aba99e","issn":["1741-2552"]},"sourceUpdateDate":"2021-08-14 07:41:11","contentUpdateDate":"2021-10-30 00:04:04","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"publication","title":"Project publication","description":"Result: Project publications","displayCode":"\/Project publication","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"PEER_REVIEWED_ARTICLE","title":"Peer reviewed articles","displayCode":"\/Peer reviewed articles","attributes":{"classification":"projectPublication","type":"isPublishedAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"742857","id":"724244_1122214_PUBLI","title":"Injectable Sensors Based on Passive Rectification of Volume-Conducted Currents","details":"\r\n    \u003Cauthors\u003EShahid Malik, Quim Castellvi, Laura Becerra-Fajardo, Marc Tudela-Pi, Aracelys Garcia-Moreno, Maryam Shojaei Baghini, Antoni Ivorra\u003C\/authors\u003E\r\n    \u003CjournalNumber\u003E14\/4\u003C\/journalNumber\u003E\r\n    \u003CjournalTitle\u003EIEEE Transactions on Biomedical Circuits and Systems\u003C\/journalTitle\u003E\r\n    \u003CpublishedPages\u003E867-878\u003C\/publishedPages\u003E\r\n    \u003CpublishedYear\u003E2020\u003C\/publishedYear\u003E\r\n    \u003Cpublisher\u003EInstitute of Electrical and Electronics Engineers\u003C\/publisher\u003E\r\n  ","identifiers":{"doi":"10.1109\/tbcas.2020.3002326","issn":["1932-4545"]},"sourceUpdateDate":"2021-08-14 07:41:11","contentUpdateDate":"2021-10-30 00:02:53","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"publication","title":"Project publication","description":"Result: Project publications","displayCode":"\/Project publication","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"PEER_REVIEWED_ARTICLE","title":"Peer reviewed articles","displayCode":"\/Peer reviewed articles","attributes":{"classification":"projectPublication","type":"isPublishedAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"941437","id":"724244_1808716_PUBLI","title":"Wireless networks of injectable microelectronic stimulators based on rectification of volume conducted high frequency currents","details":"\r\n    \u003Cauthors\u003EAracelys Garc\u00eda-Moreno; Albert Comerma-Montells; Marc Tudela-Pi; Jesus Minguillon; Laura Becerra-Fajardo; Antoni Ivorra\u003C\/authors\u003E\r\n    \u003CjournalNumber\u003E19\u003C\/journalNumber\u003E\r\n    \u003CjournalTitle\u003EJournal of Neural Engineering\u003C\/journalTitle\u003E\r\n    \u003CpublishedPages\u003E056015\u003C\/publishedPages\u003E\r\n    \u003CpublishedYear\u003E2022\u003C\/publishedYear\u003E\r\n    \u003Cpublisher\u003EInstitute of Physics Publishing\u003C\/publisher\u003E\r\n  ","identifiers":{"doi":"10.1101\/2022.03.11.483920","issn":["1741-2560"]},"sourceUpdateDate":"2023-06-05 22:00:44","contentUpdateDate":"2023-06-14 17:03:16","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"publication","title":"Project publication","description":"Result: Project publications","displayCode":"\/Project publication","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"PEER_REVIEWED_ARTICLE","title":"Peer reviewed articles","displayCode":"\/Peer reviewed articles","attributes":{"classification":"projectPublication","type":"isPublishedAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"941440","id":"724244_1808715_PUBLI","title":"Volume Conduction for Powering Deeply Implanted Networks of Wireless Injectable Medical Devices: A Numerical Parametric Analysis","details":"\r\n    \u003Cauthors\u003EMarc Tudela-Pi; Jesus Minguillon; Laura Becerra-Fajardo; Antoni Ivorra\u003C\/authors\u003E\r\n    \u003CjournalNumber\u003E9\u003C\/journalNumber\u003E\r\n    \u003CjournalTitle\u003EIEEE Access\u003C\/journalTitle\u003E\r\n    \u003CpublishedPages\u003E100594 - 100605\u003C\/publishedPages\u003E\r\n    \u003CpublishedYear\u003E2021\u003C\/publishedYear\u003E\r\n    \u003Cpublisher\u003EInstitute of Electrical and Electronics Engineers Inc.\u003C\/publisher\u003E\r\n  ","identifiers":{"doi":"10.1109\/access.2021.3096729","issn":["2169-3536"]},"sourceUpdateDate":"2023-06-05 22:00:44","contentUpdateDate":"2023-06-14 17:03:39","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"publication","title":"Project publication","description":"Result: Project publications","displayCode":"\/Project publication","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"PEER_REVIEWED_ARTICLE","title":"Peer reviewed articles","displayCode":"\/Peer reviewed articles","attributes":{"classification":"projectPublication","type":"isPublishedAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}}],"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/49\/327","title":"neurobiology","displayCode":"\/natural sciences\/biological sciences\/neurobiology","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/21\/39\/223","title":"surgery","displayCode":"\/medical and health sciences\/clinical medicine\/surgery","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/21\/37\/677","title":"implants","displayCode":"\/medical and health sciences\/medical biotechnology\/implants","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/21\/35\/153","title":"neurology","displayCode":"\/medical and health sciences\/basic medicine\/neurology","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"ERC-COG","title":"Consolidator Grant","description":"Consolidator Grant","displayCode":"\/Consolidator Grant","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"modelVersion":"132","icaVersion":"19.1.0-ea6a1f3f"}