{"contenttype":"project","language":"en","availableLanguages":"en","rcn":"224847","id":"869929","acronym":"Switch2save","teaser":"Between 25 and \u003E 60% of total energy transfer through building envelopes is driven by glass based components such as windows, glass facades and glass roofs. In winter, heating energy demand of buildings with high windows-to-wall ratio (WWR) in north- and east direction is up...","objective":"Between 25 and \u003E 60% of total energy transfer through building envelopes is driven by glass based components such as windows, glass facades and glass roofs. In winter, heating energy demand of buildings with high windows-to-wall ratio (WWR) in north- and east direction is up to 35% higher compared to buildings with only small windows. In summer, large windows and glass facades result in high heating of the building interior: cooling energy demand is increased by a factor \u2248 1.5 to 5 when WWR increases from 10% to 90%. Non-residential buildings often make use of large windows or glass facades for building-functional and representative reasons and therefore hardly suffer from increased energy demand. Switch2save targets active management of radiation energy transfer through glass-based building envelopes by integrating transparent energy smart materials with switchable total energy transmission values (g-value). Such materials are electro-chromic (EC) or thermo-chromic (TC) systems. Intelligent switching of those allows significant reduction of both heating energy demand in winter and cooling energy demand in summer. Switch2save\u2019s unique and lightweight combined EC and TC smart insulating glass unit will be a breakthrough in performance (plus 20%); low-cost potential (minus 33% manufacturing cost) and increased design opportunities compared to state-of-the-art smart shading solutions. Switch2save prototypes will be demonstrated in two representative buildings \u2013 a hospital in Athens, Greece and an office building in Uppsala, Sweden by replacing \u003E 50 windows and 200 m\u00b2 glass fa\u00e7ade area. Continuous monitoring of energy demand at thermal comfort levels inside the buildings for at least one year before and after TC\/EC integration will verify energy saving potential of Switch2save solution. Switch2save increases the market and application potential of energy smart glass in buildings \u2013 targeting the whole building glass market of 4.7 billion square meters produced per year.","title":"Lightweight switchable smart solutions for energy saving large windows and glass fa\u00e7ades","keywords":"Windows, electrochromic cells, thermochromic cells, glass facades, energy smart insulating glass units","totalCost":"6217669.48","ecMaxContribution":"5468224.21","startDate":"2019-10-01","endDate":"2023-09-30","ecSignatureDate":"2019-08-22","duration":"48","status":"CLOSED","identifiers":{"grantDoi":"10.3030\/869929"},"validation":{"euroSciVoc":"false"},"sourceUpdateDate":"2024-10-17 09:07:42","contentCreationDate":"2019-08-28 15:35:53","contentUpdateDate":"2025-09-01 23:26:08","lastUpdateDate":"2026-02-18 16:58:31","relations":{"associations":[{"availableLanguages":"de,en,es,fr,it,pl","rcn":"428481","id":"428481-smart-energy-saving-glass-solutions-for-large-windows-and-glass-facades","title":"Smart, energy-saving glass solutions for large windows and glass fa\u00e7ades","teaser":"An EU-backed project team is developing lightweight, energy-smart insulating glass units that could achieve up to 70 % energy savings in heating and cooling.","contentUpdateDate":"2020-11-26 18:35:18","archivedDate":"2023-04-17 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"ener","title":"Energy","displayCode":"\/Energy","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"news","title":"News","description":"Article: news","displayCode":"\/News","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"scientificAdvances","title":"Scientific advances","displayCode":"\/Scientific advances","attributes":{"classification":"nature","type":"groupedBy"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"de,en,es,fr,it,pl","rcn":"422346","title":"Pioneering glass fa\u00e7ade brings buildings\u2019 energy performance to another level of efficiency","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"indust","title":"Industrial Technologies","displayCode":"\/Industrial Technologies","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"ener","title":"Energy","displayCode":"\/Energy","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"brief","title":"Result in Brief","description":"Article: Classic and enhanced","displayCode":"\/Result in Brief","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"relatedArticle"}},{"availableLanguages":"de,en,es,fr,it,pl","rcn":"230803","title":"Solar energy that enhance a building\u2019s appearance","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"env","title":"Climate Change and Environment","displayCode":"\/Climate Change and Environment","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"indust","title":"Industrial Technologies","displayCode":"\/Industrial Technologies","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"ener","title":"Energy","displayCode":"\/Energy","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"brief","title":"Result in Brief","description":"Article: Classic and enhanced","displayCode":"\/Result in Brief","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"relatedArticle"}},{"availableLanguages":"de,en,es,fr,it,pl","rcn":"442819","title":"Bringing automation into materials","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"indust","title":"Industrial Technologies","displayCode":"\/Industrial Technologies","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"news","title":"News","description":"Article: news","displayCode":"\/News","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"scientificAdvances","title":"Scientific advances","displayCode":"\/Scientific advances","attributes":{"classification":"nature","type":"groupedBy"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"relatedArticle"}},{"availableLanguages":"de,en,es,fr,it,pl","rcn":"443392","title":"Creating effective assessment tools for energy-efficient buildings","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"env","title":"Climate Change and Environment","displayCode":"\/Climate Change and Environment","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"news","title":"News","description":"Article: news","displayCode":"\/News","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"scientificAdvances","title":"Scientific advances","displayCode":"\/Scientific advances","attributes":{"classification":"nature","type":"groupedBy"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"relatedArticle"}},{"availableLanguages":"de,en,es,fr,it,pl","rcn":"435738","title":"Is your smart glass design concept competition-worthy?","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"ener","title":"Energy","displayCode":"\/Energy","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"news","title":"News","description":"Article: news","displayCode":"\/News","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"scientificAdvances","title":"Scientific advances","displayCode":"\/Scientific advances","attributes":{"classification":"nature","type":"groupedBy"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"relatedArticle"}},{"availableLanguages":"de,en,es,fr,it,pl","rcn":"308457","title":"Glass curtain wall system to improve energy savings and well-being","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"indust","title":"Industrial Technologies","displayCode":"\/Industrial Technologies","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"brief","title":"Result in Brief","description":"Article: Classic and enhanced","displayCode":"\/Result in Brief","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"relatedArticle"}},{"availableLanguages":"de,en,es,fr,it,pl","rcn":"418436","title":"Dynamic glare control turns windows into transparent video screens","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"ict","title":"Digital Economy","displayCode":"\/Digital Economy","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"brief","title":"Result in Brief","description":"Article: Classic and enhanced","displayCode":"\/Result in Brief","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"relatedArticle"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl,any","uri":"\/docs\/news\/images\/2020-11\/428481.jpg","mimetype":"image\/jpeg","size":"533119","copyright":"\u00a9 Grand Warszawski, Shutterstock","contenttype":"webItem","attributes":{"represents":"article","source":"editorial","type":"relatedImage"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"relatedArticle"}},{"availableLanguages":"de,en,es,fr,it,pl","rcn":"406691","id":"406691-new-energy-saving-solutions-for-large-glass-facade-areas","title":"New energy saving solutions for large glass fa\u00e7ade areas","contentUpdateDate":"2020-01-13 12:08:21","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"projectDescription","title":"Project description","description":"Article: description of linked project written by editorial team","displayCode":"\/Project description","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"relatedArticle"}},{"availableLanguages":"de,en,es,fr,it,pl","rcn":"435738","id":"435738-is-your-smart-glass-design-concept-competition-worthy","title":"Is your smart glass design concept competition-worthy?","teaser":"Launching on 28 February 2022, the Switch2save Architectural Design Competition is giving students and young professionals a chance to showcase lightweight switchable smart glass solutions for energy-efficient glass buildings.","contentUpdateDate":"2022-02-18 15:53:15","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"ener","title":"Energy","displayCode":"\/Energy","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"news","title":"News","description":"Article: news","displayCode":"\/News","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"scientificAdvances","title":"Scientific advances","displayCode":"\/Scientific advances","attributes":{"classification":"nature","type":"groupedBy"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"de,en,es,fr,it,pl","rcn":"422346","title":"Pioneering glass fa\u00e7ade brings buildings\u2019 energy performance to another level of efficiency","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"indust","title":"Industrial Technologies","displayCode":"\/Industrial Technologies","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"ener","title":"Energy","displayCode":"\/Energy","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"brief","title":"Result in Brief","description":"Article: Classic and enhanced","displayCode":"\/Result in Brief","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"relatedArticle"}},{"availableLanguages":"de,en,es,fr,it,pl","rcn":"428481","title":"Smart, energy-saving glass solutions for large windows and glass fa\u00e7ades","archivedDate":"2023-04-17 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"ener","title":"Energy","displayCode":"\/Energy","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"news","title":"News","description":"Article: news","displayCode":"\/News","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"scientificAdvances","title":"Scientific advances","displayCode":"\/Scientific advances","attributes":{"classification":"nature","type":"groupedBy"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"relatedArticle"}},{"availableLanguages":"de,en,es,fr,it,pl","rcn":"222650","title":"Windows turn into heating and cooling systems","archivedDate":"2024-06-10 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"ener","title":"Energy","displayCode":"\/Energy","attributes":{"classification":"applicationDomain","type":"isApplicableIn","order":"1"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"funda","title":"Fundamental Research","displayCode":"\/Fundamental Research","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"brief","title":"Result in Brief","description":"Article: Classic and enhanced","displayCode":"\/Result in Brief","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"relatedArticle"}},{"availableLanguages":"de,en,es,fr,it,pl","rcn":"443392","title":"Creating effective assessment tools for energy-efficient buildings","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"env","title":"Climate Change and Environment","displayCode":"\/Climate Change and Environment","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"news","title":"News","description":"Article: news","displayCode":"\/News","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"scientificAdvances","title":"Scientific advances","displayCode":"\/Scientific advances","attributes":{"classification":"nature","type":"groupedBy"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"relatedArticle"}},{"availableLanguages":"de,en,es,fr,it,pl","rcn":"308457","title":"Glass curtain wall system to improve energy savings and well-being","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"indust","title":"Industrial Technologies","displayCode":"\/Industrial Technologies","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"brief","title":"Result in Brief","description":"Article: Classic and enhanced","displayCode":"\/Result in Brief","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"relatedArticle"}},{"availableLanguages":"de,en,es,fr,it,pl","rcn":"418436","title":"Dynamic glare control turns windows into transparent video screens","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"ict","title":"Digital Economy","displayCode":"\/Digital Economy","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"brief","title":"Result in Brief","description":"Article: Classic and enhanced","displayCode":"\/Result in Brief","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"relatedArticle"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl,any","uri":"\/docs\/news\/images\/2022-02\/435738.jpg","mimetype":"image\/jpeg","size":"273008","copyright":"\u00a9 Verticalarray, Shutterstock","contenttype":"webItem","attributes":{"represents":"article","source":"editorial","type":"relatedImage"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"relatedArticle"}},{"rcn":"54215","identifier":"H2020-NMBP-EEB-2019","contenttype":"call","attributes":{"source":"corda","type":"relatedSubCall"}},{"rcn":"53430","title":"H2020-NMBP-ST-IND-2018-2020","identifier":"H2020-NMBP-ST-IND-2018-2020","contenttype":"call","attributes":{"source":"corda","type":"relatedMasterCall"}},{"availableLanguages":"en","rcn":"1906106","id":"999978142","vatNumber":"EL099793475","legalName":"ETHNICON METSOVION POLYTECHNION","shortName":"NATIONAL TECHNICAL UNIVERSITY OF ATHENS - NTUA","address":{"street":"HEROON POLYTECHNIOU 9 ZOGRAPHOU CAMPUS","city":"ATHINA","postalCode":"157 72","country":"EL","url":"http:\/\/www.ntua.gr","geolocation":"38.9953683,21.9877132"},"departmentName":["Research Committee of NTUA"],"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"HES","title":"Higher or Secondary Education Establishments","displayCode":"\/Higher or Secondary Education Establishments","attributes":{"classification":"organizationActivityType","type":"relatedOrganizationActivityType"}}],"regions":[{"name":"\u039a\u03b5\u03bd\u03c4\u03c1\u03b9\u03ba\u03cc\u03c2 \u03a4\u03bf\u03bc\u03ad\u03b1\u03c2 \u0391\u03b8\u03b7\u03bd\u03ce\u03bd","rcn":"1465456","nutsCode":"EL303","parents":{"name":"A\u03c4\u03c4\u03b9\u03ba\u03ae\/\u0391\u03c4\u03c4\u03b9\u03ba\u03ae \/Greece","rcn":"1464908\/1464907\/240552488","nutsCode":"EL30\/EL3\/EL","euCode":"EL","isoCode":"EL"},"attributes":{"type":"relatedNutsCode"}},{"name":"Greece","rcn":"240552488","nutsCode":"EL","euCode":"EL","isoCode":"EL","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"ecContribution":"875762.5","sme":"false","source":"corda","type":"participant","netEcContribution":"875762.5","terminated":"false","totalCost":"875762.5","order":"3"}},{"availableLanguages":"en","rcn":"1905912","id":"999984059","vatNumber":"DE129515865","legalName":"FRAUNHOFER GESELLSCHAFT ZUR FORDERUNG DER ANGEWANDTEN FORSCHUNG EV","shortName":"Fraunhofer","address":{"street":"HANSASTRASSE 27C","city":"Munchen","postalCode":"80686","country":"DE","url":"https:\/\/www.fraunhofer.de","geolocation":"48.132741991,11.53014802"},"departmentName":["Integrated Project Management"],"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"REC","title":"Research Organisations","displayCode":"\/Research Organisations","attributes":{"classification":"organizationActivityType","type":"relatedOrganizationActivityType"}}],"regions":[{"name":"M\u00fcnchen, Kreisfreie Stadt","rcn":"221782082","nutsCode":"DE212","parents":{"name":"Oberbayern\/Bayern\/Germany","rcn":"221782120\/221784616\/221940264","nutsCode":"DE21\/DE2\/DE","euCode":"DE","isoCode":"DE"},"attributes":{"type":"relatedNutsCode"}},{"name":"Germany","rcn":"221940264","nutsCode":"DE","euCode":"DE","isoCode":"DE","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"ecContribution":"1857808.75","sme":"false","source":"corda","type":"coordinator","netEcContribution":"1857808.75","terminated":"false","totalCost":"1857808.75","order":"1"}},{"availableLanguages":"en","rcn":"1960154","id":"951847615","vatNumber":"SE556061460301","legalName":"VASAKRONAN AB","address":{"street":"MASTER SAMUELSGATAN 56","city":"Stockholm","postalCode":"104 25","country":"SE","geolocation":"59.3340387,18.0678471"},"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"PRC","title":"Private for-profit entities (excluding Higher or Secondary Education Establishments)","displayCode":"\/Private for-profit entities (excluding Higher or Secondary Education Establishments)","attributes":{"classification":"organizationActivityType","type":"relatedOrganizationActivityType"}}],"regions":[{"name":"Stockholms l\u00e4n","rcn":"473436224","nutsCode":"SE110","parents":{"name":"Stockholm\/\u00d6stra Sverige\/Sweden","rcn":"473436264\/473438760\/473598504","nutsCode":"SE11\/SE1\/SE","euCode":"SE","isoCode":"SE"},"attributes":{"type":"relatedNutsCode"}},{"name":"Sweden","rcn":"473598504","nutsCode":"SE","euCode":"SE","isoCode":"SE","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"ecContribution":"127750","sme":"false","source":"corda","type":"participant","netEcContribution":"127750","terminated":"false","totalCost":"182500","order":"7"}},{"availableLanguages":"en","rcn":"2115492","id":"999438822","vatNumber":"SE556630180901","legalName":"CHROMOGENICS AB","address":{"street":"ULLFORSGATAN 15","city":"Uppsala","postalCode":"752 28","country":"SE","geolocation":"59.8805924,17.589426105840218"},"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"PRC","title":"Private for-profit entities (excluding Higher or Secondary Education Establishments)","displayCode":"\/Private for-profit entities (excluding Higher or Secondary Education Establishments)","attributes":{"classification":"organizationActivityType","type":"relatedOrganizationActivityType"}}],"regions":[{"name":"Uppsala l\u00e4n","rcn":"473436289","nutsCode":"SE121","parents":{"name":"\u00d6stra Mellansverige\/\u00d6stra Sverige\/Sweden","rcn":"473436328\/473438760\/473598504","nutsCode":"SE12\/SE1\/SE","euCode":"SE","isoCode":"SE"},"attributes":{"type":"relatedNutsCode"}},{"name":"Sweden","rcn":"473598504","nutsCode":"SE","euCode":"SE","isoCode":"SE","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"ecContribution":"1035912.5","sme":"true","source":"corda","type":"participant","netEcContribution":"1035912.5","terminated":"false","totalCost":"1479875","order":"2"}},{"availableLanguages":"en","rcn":"1960152","id":"903523864","vatNumber":"LV40103163626","legalName":"SIA AGL TECHNOLOGIES","address":{"street":"SMERLA IELA 3","city":"Riga","postalCode":"LV-1006","country":"LV","geolocation":"56.9657957,24.1603609"},"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"PRC","title":"Private for-profit entities (excluding Higher or Secondary Education Establishments)","displayCode":"\/Private for-profit entities (excluding Higher or Secondary Education Establishments)","attributes":{"classification":"organizationActivityType","type":"relatedOrganizationActivityType"}}],"regions":[{"name":"R\u012bga","rcn":"360448006","nutsCode":"LV006","parents":{"name":"Latvija\/Latvija\/Latvia","rcn":"360448040\/360450600\/360614440","nutsCode":"LV00\/LV0\/LV","euCode":"LV","isoCode":"LV"},"attributes":{"type":"relatedNutsCode"}},{"name":"Latvia","rcn":"360614440","nutsCode":"LV","euCode":"LV","isoCode":"LV","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"ecContribution":"95490.5","sme":"false","source":"corda","type":"participant","netEcContribution":"95490.5","terminated":"false","totalCost":"136415","order":"5"}},{"availableLanguages":"en","rcn":"2672419","id":"944492881","vatNumber":"BE0740182056","legalName":"VAN ROMPAEY SARA","shortName":"E2ARC","address":{"street":"THEOPHIEL VAN DER CRUYSSENHOF 9","city":"Lochristi","postalCode":"9080","country":"BE","geolocation":"51.084561293,3.8318747114"},"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"PRC","title":"Private for-profit entities (excluding Higher or Secondary Education Establishments)","displayCode":"\/Private for-profit entities (excluding Higher or Secondary Education Establishments)","attributes":{"classification":"organizationActivityType","type":"relatedOrganizationActivityType"}}],"regions":[{"name":"Arr. Gent","rcn":"188227780","nutsCode":"BE234","parents":{"name":"Prov. Oost-Vlaanderen\/Vlaams Gewest\/Belgium","rcn":"188227816\/188230184\/188385832","nutsCode":"BE23\/BE2\/BE","euCode":"BE","isoCode":"BE"},"attributes":{"type":"relatedNutsCode"}},{"name":"Belgium","rcn":"188385832","nutsCode":"BE","euCode":"BE","isoCode":"BE","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"ecContribution":"58179.28","source":"corda","type":"participant","netEcContribution":"58179.28","terminated":"true","totalCost":"83113.26","order":"9"}},{"availableLanguages":"en","rcn":"1963935","id":"897837918","vatNumber":"CZ08466068","legalName":"AMIRES THE BUSINESS INNOVATION MANAGEMENT INSTITUTE ZU","address":{"street":"NA OKRAJI 335 42 VELESLAVIN","city":"PRAGUE","postalCode":"162 00","country":"CZ","geolocation":"50.089106103,14.342051649"},"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"OTH","title":"Other","displayCode":"\/Other","attributes":{"classification":"organizationActivityType","type":"relatedOrganizationActivityType"}}],"regions":[{"name":"Hlavn\u00ed m\u011bsto Praha","rcn":"1465479","nutsCode":"CZ010","parents":{"name":"Praha\/\u010cesko\/Czechia","rcn":"210501736\/1465445\/210668072","nutsCode":"CZ01\/CZ0\/CZ","euCode":"CZ","isoCode":"CZ"},"attributes":{"type":"relatedNutsCode"}},{"name":"Czechia","rcn":"210668072","nutsCode":"CZ","euCode":"CZ","isoCode":"CZ","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"ecContribution":"136063","sme":"false","source":"corda","type":"participant","netEcContribution":"136063","terminated":"false","totalCost":"151250","order":"11"}},{"availableLanguages":"en","rcn":"1967585","id":"894753415","vatNumber":"BE0752654276","legalName":"E2ARC ARCHITECTURE RESEARCH FOR CITIES","shortName":"E2ARC","address":{"street":"Schoolstraat 7","city":"Mechelen","postalCode":"2800","country":"BE","geolocation":"51.029350618,4.4797091579"},"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"REC","title":"Research Organisations","displayCode":"\/Research Organisations","attributes":{"classification":"organizationActivityType","type":"relatedOrganizationActivityType"}}],"regions":[{"name":"Arr. Mechelen","rcn":"188227650","nutsCode":"BE212","parents":{"name":"Prov. Antwerpen\/Vlaams Gewest\/Belgium","rcn":"188227688\/188230184\/188385832","nutsCode":"BE21\/BE2\/BE","euCode":"BE","isoCode":"BE"},"attributes":{"type":"relatedNutsCode"}},{"name":"Belgium","rcn":"188385832","nutsCode":"BE","euCode":"BE","isoCode":"BE","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"ecContribution":"233633.18","sme":"false","source":"corda","type":"participant","netEcContribution":"233633.18","totalCost":"233633.18","terminated":"false","order":"12"}},{"availableLanguages":"en","rcn":"1922674","id":"999843894","vatNumber":"CZ49777513","legalName":"ZAPADOCESKA UNIVERZITA V PLZNI","shortName":"UNIVERSITY OF WEST BOHEMIA IN PILSEN","address":{"street":"UNIVERZITNI 8","city":"Pilsen","postalCode":"301 00","country":"CZ","url":"http:\/\/www.zcu.cz","geolocation":"49.723686976,13.351565587"},"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"HES","title":"Higher or Secondary Education Establishments","displayCode":"\/Higher or Secondary Education Establishments","attributes":{"classification":"organizationActivityType","type":"relatedOrganizationActivityType"}}],"regions":[{"name":"Plze\u0148sk\u00fd kraj","rcn":"210501826","nutsCode":"CZ032","parents":{"name":"Jihoz\u00e1pad\/\u010cesko\/Czechia","rcn":"210501864\/1465445\/210668072","nutsCode":"CZ03\/CZ0\/CZ","euCode":"CZ","isoCode":"CZ"},"attributes":{"type":"relatedNutsCode"}},{"name":"Czechia","rcn":"210668072","nutsCode":"CZ","euCode":"CZ","isoCode":"CZ","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"ecContribution":"280937.5","sme":"false","source":"corda","type":"participant","netEcContribution":"280937.5","terminated":"false","totalCost":"280937.5","order":"4"}},{"availableLanguages":"en","rcn":"1960155","id":"917187866","vatNumber":"EL999516730","legalName":"GENIKO NOSOKOMEIO NIKAIAS PEIRAIOSAGIOS PANTELEIMON - GN DYTIKIS ATTIKIS I AGIA VARVARA","address":{"street":"DIMITRIOU MANDOUVALOY 3","city":"Nikaia Piraeus","postalCode":"18454","country":"EL","geolocation":"37.9747006,23.67089386377242"},"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"PUB","title":"Public bodies (excluding Research Organisations and Secondary or Higher Education Establishments)","displayCode":"\/Public bodies (excluding Research Organisations and Secondary or Higher Education Establishments)","attributes":{"classification":"organizationActivityType","type":"relatedOrganizationActivityType"}}],"regions":[{"name":"\u03a0\u03b5\u03b9\u03c1\u03b1\u03b9\u03ac\u03c2","rcn":"1464129","nutsCode":"EL307","parents":{"name":"A\u03c4\u03c4\u03b9\u03ba\u03ae\/\u0391\u03c4\u03c4\u03b9\u03ba\u03ae \/Greece","rcn":"1464908\/1464907\/240552488","nutsCode":"EL30\/EL3\/EL","euCode":"EL","isoCode":"EL"},"attributes":{"type":"relatedNutsCode"}},{"name":"Greece","rcn":"240552488","nutsCode":"EL","euCode":"EL","isoCode":"EL","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"ecContribution":"370750","sme":"false","source":"corda","type":"participant","netEcContribution":"370750","terminated":"false","totalCost":"370750","order":"8"}},{"availableLanguages":"en","rcn":"1960153","id":"903204734","vatNumber":"SE556325954701","legalName":"FASADGLAS BAECKLIN AB","address":{"street":"KARLBODAVAEGEN 9-11","city":"Bromma","postalCode":"161 11","country":"SE","geolocation":"59.3546192,17.944740459281977"},"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"PRC","title":"Private for-profit entities (excluding Higher or Secondary Education Establishments)","displayCode":"\/Private for-profit entities (excluding Higher or Secondary Education Establishments)","attributes":{"classification":"organizationActivityType","type":"relatedOrganizationActivityType"}}],"regions":[{"name":"Stockholms l\u00e4n","rcn":"473436224","nutsCode":"SE110","parents":{"name":"Stockholm\/\u00d6stra Sverige\/Sweden","rcn":"473436264\/473438760\/473598504","nutsCode":"SE11\/SE1\/SE","euCode":"SE","isoCode":"SE"},"attributes":{"type":"relatedNutsCode"}},{"name":"Sweden","rcn":"473598504","nutsCode":"SE","euCode":"SE","isoCode":"SE","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"ecContribution":"344750","sme":"false","source":"corda","type":"participant","netEcContribution":"344750","terminated":"false","totalCost":"492500","order":"6"}},{"availableLanguages":"en","rcn":"1952213","id":"956723805","vatNumber":"CZ24173720","legalName":"AMIRES SRO","address":{"street":"NA OKRAJI 335\/42","city":"Praha","postalCode":"162 00","country":"CZ","geolocation":"50.089106103,14.342051649"},"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"PRC","title":"Private for-profit entities (excluding Higher or Secondary Education Establishments)","displayCode":"\/Private for-profit entities (excluding Higher or Secondary Education Establishments)","attributes":{"classification":"organizationActivityType","type":"relatedOrganizationActivityType"}}],"regions":[{"name":"Hlavn\u00ed m\u011bsto Praha","rcn":"1465479","nutsCode":"CZ010","parents":{"name":"Praha\/\u010cesko\/Czechia","rcn":"210501736\/1465445\/210668072","nutsCode":"CZ01\/CZ0\/CZ","euCode":"CZ","isoCode":"CZ"},"attributes":{"type":"relatedNutsCode"}},{"name":"Czechia","rcn":"210668072","nutsCode":"CZ","euCode":"CZ","isoCode":"CZ","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"ecContribution":"51187","sme":"true","source":"corda","type":"participant","netEcContribution":"51187","terminated":"true","totalCost":"73124.29","order":"10"}},{"availableLanguages":"de,en,es,fr,it,pl","rcn":"664201","id":"H2020-EU.2.1.5.2.","code":"H2020-EU.2.1.5.2.","frameworkProgramme":"H2020","pga":"H2020-EU.2.1.5.2.","title":"Technologies enabling energy-efficient systems and energy-efficient buildings with a low environmental impact","shortTitle":"Technologies enabling energy-efficient systems and buildings","parent":{"rcn":"664197\/664145\/664143\/664087\/664086","code":"H2020-EU.2.1.5.\/H2020-EU.2.1.\/H2020-EU.2.\/H2020-EC\/H2020"},"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"legalbasis","title":"Legal Basis","description":"Programme: Legal basis for research funding","displayCode":"\/Legal Basis","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedLegalBasis"}},{"availableLanguages":"de,en,es,fr,it,pl","rcn":"664197","id":"H2020-EU.2.1.5.","code":"H2020-EU.2.1.5.","frameworkProgramme":"H2020","pga":"H2020-EU.2.1.5.","title":"INDUSTRIAL LEADERSHIP - Leadership in enabling and industrial technologies - Advanced manufacturing and processing","shortTitle":"Advanced manufacturing and processing","parent":{"rcn":"664145\/664143\/664087\/664086","code":"H2020-EU.2.1.\/H2020-EU.2.\/H2020-EC\/H2020"},"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"legalbasis","title":"Legal Basis","description":"Programme: Legal basis for research funding","displayCode":"\/Legal Basis","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedLegalBasis","uniqueProgrammePart":"true"}},{"availableLanguages":"en","rcn":"702937","id":"H2020_LC-EEB-01-2019","code":"LC-EEB-01-2019","frameworkProgramme":"H2020","title":"Integration of energy smart materials in non-residential buildings (IA)","parent":{"rcn":"20200","code":"H2020-Topics"},"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"topic","title":"Topic","description":"Programme: Part of the Commission work programme implementing legal basis","displayCode":"\/Topic","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}},{"language":"en","availableLanguages":"en","code":"31049065","title":"Lightweight construction, textile technology","displayCode":"\/Lightweight construction, textile technology","attributes":{"classification":"topicKeyword","type":"isAbout"}},{"language":"en","availableLanguages":"en","code":"31049185","title":"Nanotechnology, nano-materials, nano engineering","displayCode":"\/Nanotechnology, nano-materials, nano engineering","attributes":{"classification":"topicKeyword","type":"isAbout"}},{"language":"en","availableLanguages":"en","code":"31049183","title":"Materials engineering","displayCode":"\/Materials engineering","attributes":{"classification":"topicKeyword","type":"isAbout"}},{"language":"en","availableLanguages":"en","code":"31049182","title":"Production technology, process engineering","displayCode":"\/Production technology, process engineering","attributes":{"classification":"topicKeyword","type":"isAbout"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedTopic"}},{"availableLanguages":"en","rcn":"864592","id":"869929_24_DELIV","title":"Improved testing methodology and characterisation procedures for long-term performance assessment of EC\/TC windows","description":"Report on refined and improved characterisation metrology and test methodology to determine long term performance of energy smart windows  to be made available to public as open access white paper or journal article","sourceUpdateDate":"2022-08-10 01:41:41","contentUpdateDate":"2022-09-13 17:45:58","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"R","title":"Documents, reports","displayCode":"\/Documents, reports","attributes":{"classification":"deliverableType","type":"isDeliveredAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"language":"en","availableLanguages":"en","defaultLanguage":"en","id":"72acc5540d835d6878902dd8033eaabe","physUrl":"https:\/\/ec.europa.eu\/research\/participants\/documents\/downloadPublic?documentIds=080166e5e23baea5\u0026appId=PPGMS","contenttype":"webLink","attributes":{"represents":"project","source":"corda","type":"projectDeliverable"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"864734","id":"869929_13_DELIV","title":"Energy smart IGU fulfilling the specification of D1.1 with an U-value \u003C 0.7 W\/(m\u00b2K) and at least VLT modulation of 50% to 10% and g-value modulation from 30% to 15%; as well as \u003C 2% weight increase compared to SoA low-E IGU (1st generation based on EC)","description":"Prototypes of insulating glass units IGU that are equipped with both electrochromic and thermochromic materials fulfilling the specification of D11 The report to be submitted will include the electrical optical and thermal transport properties of the IGUs The IGU prototypes will be made visible to a wider public through Switch2Save Events conferences and trade fairs","sourceUpdateDate":"2022-08-10 01:41:41","contentUpdateDate":"2022-09-13 17:47:15","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"D","title":"Demonstrators, pilots, prototypes","displayCode":"\/Demonstrators, pilots, prototypes","attributes":{"classification":"deliverableType","type":"isDeliveredAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"language":"en","availableLanguages":"en","defaultLanguage":"en","id":"57426f340d6beccdecd1022135a363c7","physUrl":"https:\/\/ec.europa.eu\/research\/participants\/documents\/downloadPublic?documentIds=080166e5e58a1a44\u0026appId=PPGMS","contenttype":"webLink","attributes":{"represents":"project","source":"corda","type":"projectDeliverable"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"1124742","id":"869929_27_DELIV","title":"Fire testing results for optimised IGUs","description":"Report on fire-safety testing results on Switch2Save IGU and (if required) suggestions for improvement","sourceUpdateDate":"2024-06-29 00:27:23","contentUpdateDate":"2024-07-01 13:20:10","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"R","title":"Documents, reports","displayCode":"\/Documents, reports","attributes":{"classification":"deliverableType","type":"isDeliveredAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"language":"en","availableLanguages":"en","defaultLanguage":"en","id":"cb142029ad63fb562b6ae0ce5eb8c01e","physUrl":"https:\/\/ec.europa.eu\/research\/participants\/documents\/downloadPublic?documentIds=080166e50156945b\u0026appId=PPGMS","contenttype":"webLink","attributes":{"source":"corda","type":"projectDeliverable"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"1124759","id":"869929_67_DELIV","title":"Energy smart IGU fulfilling the specification of D1.1 with an U-value \u003C 0.7 W\/(m\u00b2K) and at least VLT modulation of 50% to 10% and g-value modulation from 35% to 10%; as well as \u003C 2% weight increase compared to SoA low-E IGU (2nd generation TC \u0026 EC based)","description":"Energy smart IGU fulfilling the specification of D1.1 with an U-value \u003C 0.7 W\/(m\u00b2K) and at least VLT modulation of 50% to 10% and g-value modulation from 35% to 10%; as well as \u003C 2% weight increase compared to SoA low-E IGU (2nd generation system based on electrochromic and thermochromic system)","sourceUpdateDate":"2024-06-29 00:27:23","contentUpdateDate":"2024-07-01 13:20:12","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"D","title":"Demonstrators, pilots, prototypes","displayCode":"\/Demonstrators, pilots, prototypes","attributes":{"classification":"deliverableType","type":"isDeliveredAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"language":"en","availableLanguages":"en","defaultLanguage":"en","id":"4d5a0f4dfdd72b2b7cc2b48d19260831","physUrl":"https:\/\/ec.europa.eu\/research\/participants\/documents\/downloadPublic?documentIds=080166e5f97a9e1a\u0026appId=PPGMS","contenttype":"webLink","attributes":{"source":"corda","type":"projectDeliverable"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"1124753","id":"869929_41_DELIV","title":"Technical data sheets and BIM file available","description":"Preparation of technical datasheets and packages of \u201cBuilding Information Modelling\u201d (BIM) files of the Switch2Save IGUs that were integrated to the DEMO buildings. The package will be disseminated to potential users (architects, construction engineers) for promoting the Switch2Save solutions","sourceUpdateDate":"2024-06-29 00:27:23","contentUpdateDate":"2024-07-01 13:20:12","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"R","title":"Documents, reports","displayCode":"\/Documents, reports","attributes":{"classification":"deliverableType","type":"isDeliveredAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"language":"en","availableLanguages":"en","defaultLanguage":"en","id":"a46fc7db19ce2242bca780cc9fc9a3d7","physUrl":"https:\/\/ec.europa.eu\/research\/participants\/documents\/downloadPublic?documentIds=080166e50156c162\u0026appId=PPGMS","contenttype":"webLink","attributes":{"source":"corda","type":"projectDeliverable"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"721796","id":"869929_38_DELIV","title":"Project website","description":"Report on the website structure, screenshots and first contents published","sourceUpdateDate":"2021-09-23 13:00:56","contentUpdateDate":"2021-09-24 20:52:48","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"DEC","title":"Websites, patent fillings, videos etc.","displayCode":"\/Websites, patent fillings, videos etc.","attributes":{"classification":"deliverableType","type":"isDeliveredAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"language":"en","availableLanguages":"en","defaultLanguage":"en","id":"ceeb9ae674ac886b2eecd8f35bc6572c","physUrl":"https:\/\/ec.europa.eu\/research\/participants\/documents\/downloadPublic?documentIds=080166e5cba86afc\u0026appId=PPGMS","contenttype":"webLink","attributes":{"represents":"project","source":"corda","type":"projectDeliverable"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"1124745","id":"869929_25_DELIV","title":"Thermal performance of IGUs at component level","description":"Report on thermal performance of the Switch2Save IGUs determined in measurements in the Mockup-Building at NTUA campus","sourceUpdateDate":"2024-06-29 00:27:23","contentUpdateDate":"2024-07-01 13:20:10","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"R","title":"Documents, reports","displayCode":"\/Documents, reports","attributes":{"classification":"deliverableType","type":"isDeliveredAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"language":"en","availableLanguages":"en","defaultLanguage":"en","id":"a23e58784a2e03bf066da45612c2d355","physUrl":"https:\/\/ec.europa.eu\/research\/participants\/documents\/downloadPublic?documentIds=080166e5015a2c01\u0026appId=PPGMS","contenttype":"webLink","attributes":{"source":"corda","type":"projectDeliverable"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"721797","id":"869929_10_DELIV","title":"Specification sheets for energy smart IGUs","description":"Requirements from building design, comfort, safety regulations and building energy consumption directives will be translated to a technical specification sheet (report) including targeted transmission spectrum, color rendering index, weight, mounting aspects, consequences for materials use, etc.","sourceUpdateDate":"2021-09-23 13:00:56","contentUpdateDate":"2021-09-24 20:52:48","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"R","title":"Documents, reports","displayCode":"\/Documents, reports","attributes":{"classification":"deliverableType","type":"isDeliveredAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"language":"en","availableLanguages":"en","defaultLanguage":"en","id":"48cff8a9d2044123f9799af7dbec7996","physUrl":"https:\/\/ec.europa.eu\/research\/participants\/documents\/downloadPublic?documentIds=080166e5cda10327\u0026appId=PPGMS","contenttype":"webLink","attributes":{"represents":"project","source":"corda","type":"projectDeliverable"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"735887","id":"869929_PS","title":"Periodic Reporting for period 3 - Switch2save (Lightweight switchable smart solutions for energy saving large windows and glass fa\u00e7ades)","teaser":"In modern architecture, large-area glazing is a continuing trend because of its appearance and design variety. Large southwards-oriented windows help to reduce the energy demand for heating in winter. However, large-area glazing may significantly increase the energy demand for...","description":"periodic","sourceUpdateDate":"2024-07-28 15:35:29","contentUpdateDate":"2024-09-12 09:40:30","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"pubsum","title":"Report Summary","description":"Result: Publishable summary (FP7 SESAM) and Summary for publication (H2020 SyGMa)","displayCode":"\/Report Summary","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"language":"en","availableLanguages":"en,any","uri":"\/docs\/results\/h2020\/869\/869929_PS\/14-2019-02.jpg","alternativeText":"EC-TC smart glass","mimetype":"image\/jpeg","size":"190464","contenttype":"webItem","attributes":{"source":"corda","type":"relatedResultAttachment"}},{"language":"en","availableLanguages":"en","defaultLanguage":"en","id":"4dd6bb92a0866fb8a1c23a46d3101e06","archivedDate":"2025-07-08 00:00:00","physUrl":"http:\/\/www.switch2save.eu","status":"legacy","contenttype":"webLink","attributes":{"represents":"project","source":"corda","type":"relatedWebsite"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"864584","id":"869929_9_DELIV","title":"Uniform TC thin glass samples (\u003C\u00b15% deviation) with switching temperature \u003C 30\u00b0C (within interval of \u00b1 2K); and with VLT \u003E 60% and Tsol \u226510%; TC thin glass device dimensions: 1000 x 300 mm\u00b2 (sheets); 4000 x 300 mm\u00b2 (rolls)","description":"Operational thermochromic thin glass samples verified against the specification of D11","sourceUpdateDate":"2022-08-10 01:41:41","contentUpdateDate":"2022-09-13 17:45:53","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"D","title":"Demonstrators, pilots, prototypes","displayCode":"\/Demonstrators, pilots, prototypes","attributes":{"classification":"deliverableType","type":"isDeliveredAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"language":"en","availableLanguages":"en","defaultLanguage":"en","id":"9033a29aadc10a21b33233cf47948c9f","physUrl":"https:\/\/ec.europa.eu\/research\/participants\/documents\/downloadPublic?documentIds=080166e5e536f777\u0026appId=PPGMS","contenttype":"webLink","attributes":{"represents":"project","source":"corda","type":"projectDeliverable"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"1124751","id":"869929_42_DELIV","title":"Technical Documentation for EPD","description":"Environmental Product Declaration Document (EPD) according to ISO 21930 for the Switch2Save Energy Smart IGUs","sourceUpdateDate":"2024-06-29 00:27:23","contentUpdateDate":"2024-07-01 13:20:12","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"R","title":"Documents, reports","displayCode":"\/Documents, reports","attributes":{"classification":"deliverableType","type":"isDeliveredAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"language":"en","availableLanguages":"en","defaultLanguage":"en","id":"62f2f1773673448add403c0f49a95e40","physUrl":"https:\/\/ec.europa.eu\/research\/participants\/documents\/downloadPublic?documentIds=080166e50448968b\u0026appId=PPGMS","contenttype":"webLink","attributes":{"source":"corda","type":"projectDeliverable"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"721792","id":"869929_7_DELIV","title":"Energy efficient EC-device fulfilling D1.1 specification, VLT modulation \u003C 10 % to \u003E 70 %; g-value modulation \u003C10% to 50% demonstrated on 1500 x 5000 mm\u00b2","description":"Operational large-area electrochromic cells on polymer webs fulfilling the requirements of D1.1. The submittable report will include electrical parameters and performance data of the cells. The Demonstrator will be made available to the public through  Switch2Save events and Conference or trade fair visits.","sourceUpdateDate":"2021-09-23 13:00:56","contentUpdateDate":"2021-09-24 20:52:47","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"D","title":"Demonstrators, pilots, prototypes","displayCode":"\/Demonstrators, pilots, prototypes","attributes":{"classification":"deliverableType","type":"isDeliveredAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"language":"en","availableLanguages":"en","defaultLanguage":"en","id":"a593bc576332ce0bb341de56381e909f","physUrl":"https:\/\/ec.europa.eu\/research\/participants\/documents\/downloadPublic?documentIds=080166e5db487c55\u0026appId=PPGMS","contenttype":"webLink","attributes":{"represents":"project","source":"corda","type":"projectDeliverable"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"1124748","id":"869929_35_DELIV","title":"Full life cycle assessment of materials and components","description":"Report on Environmental performance of the Switch2save IGUs including full end-of-life assessment; energy payback time (comparing energy used for producing the IGUs to energy saved through using it). The Report will further give guidelines for recycling of the IGUs and the respective components","sourceUpdateDate":"2024-06-29 00:27:23","contentUpdateDate":"2024-07-01 13:20:10","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"R","title":"Documents, reports","displayCode":"\/Documents, reports","attributes":{"classification":"deliverableType","type":"isDeliveredAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"language":"en","availableLanguages":"en","defaultLanguage":"en","id":"3b91475f0394e8532bd849df3d10ce78","physUrl":"https:\/\/ec.europa.eu\/research\/participants\/documents\/downloadPublic?documentIds=080166e5f978481e\u0026appId=PPGMS","contenttype":"webLink","attributes":{"source":"corda","type":"projectDeliverable"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"1124741","id":"869929_29_DELIV","title":"Monitoring of the Hospital\u0027s clinic performance prior to the installation of IGUs","description":"Report on Energy Demand data of the Hospital Clinics for one year based on the currently installed windows and balcony doors including temperature levels, energy consumption for heating and energy consumption for cooling","sourceUpdateDate":"2024-06-29 00:27:23","contentUpdateDate":"2024-07-01 13:20:10","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"R","title":"Documents, reports","displayCode":"\/Documents, reports","attributes":{"classification":"deliverableType","type":"isDeliveredAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"language":"en","availableLanguages":"en","defaultLanguage":"en","id":"c8de2792f49b292a52f5fa390961a8e0","physUrl":"https:\/\/ec.europa.eu\/research\/participants\/documents\/downloadPublic?documentIds=080166e5f306a9d1\u0026appId=PPGMS","contenttype":"webLink","attributes":{"source":"corda","type":"projectDeliverable"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"726135","id":"869929_1042433_PUBLI","title":"Pulsed Magnetron Sputtering of Strongly Thermochromic VO2-Based Coatings with a Transition Temperature of 22 \u00b0C onto Ultrathin Flexible Glass","details":"\r\n    \u003Cauthors\u003ETom\u00e1\u0161 B\u00e1rta, Jaroslav Vl\u010dek, Ji\u0159\u00ed Hou\u0161ka, Stanislav Haviar, Radom\u00edr \u010cerstv\u00fd, Jolanta Szelwicka, Matthias Fahland, John Fahlteich\u003C\/authors\u003E\r\n    \u003CjournalNumber\u003E10\/12\u003C\/journalNumber\u003E\r\n    \u003CjournalTitle\u003ECoatings\u003C\/journalTitle\u003E\r\n    \u003CpublishedPages\u003E1258\u003C\/publishedPages\u003E\r\n    \u003CpublishedYear\u003E2020\u003C\/publishedYear\u003E\r\n    \u003Cpublisher\u003EMDPI\u003C\/publisher\u003E\r\n  ","identifiers":{"doi":"10.3390\/coatings10121258","issn":["2079-6412"]},"sourceUpdateDate":"2021-05-29 08:52:43","contentUpdateDate":"2021-10-01 15:38:50","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"publication","title":"Project publication","description":"Result: Project publications","displayCode":"\/Project publication","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"PEER_REVIEWED_ARTICLE","title":"Peer reviewed articles","displayCode":"\/Peer reviewed articles","attributes":{"classification":"projectPublication","type":"isPublishedAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"841075","id":"869929_1402106_PUBLI","title":"Transfer of the sputter technique for deposition of strongly thermochromic VO2-based coatings on ultrathin flexible glass to large-scale roll-to-roll device","details":"\r\n    \u003Cauthors\u003EJi\u0159\u00ed Rezek; Jolanta Szelwicka; Jaroslav Vl\u010dek; Radom\u00edr \u010cerstv\u00fd; Ji\u0159\u00ed Hou\u0161ka; Matthias Fahland; John Fahlteich\u003C\/authors\u003E\r\n    \u003CjournalNumber\u003E1\u003C\/journalNumber\u003E\r\n    \u003CjournalTitle\u003ESurface and Coatings Technology\u003C\/journalTitle\u003E\r\n    \u003CpublishedPages \/\u003E\r\n    \u003CpublishedYear\u003E2022\u003C\/publishedYear\u003E\r\n    \u003Cpublisher\u003EElsevier BV\u003C\/publisher\u003E\r\n  ","identifiers":{"doi":"10.1016\/j.surfcoat.2022.128273","issn":["0257-8972"]},"sourceUpdateDate":"2022-05-31 19:20:38","contentUpdateDate":"2022-06-09 19:23:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"publication","title":"Project publication","description":"Result: Project publications","displayCode":"\/Project publication","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"PEER_REVIEWED_ARTICLE","title":"Peer reviewed articles","displayCode":"\/Peer reviewed articles","attributes":{"classification":"projectPublication","type":"isPublishedAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"1124752","id":"869929_36_DELIV","title":"Key Performance Indicators (KPIs) for glass facade buildings","description":"Report on performances of Switch2save IGUs involving KPIs relevant to large glass-fa\u00e7ade buildings to support decision of building owners \/ construction companies to include Switch2Save Solutions to new buildings or in renovations","sourceUpdateDate":"2024-06-29 00:27:23","contentUpdateDate":"2024-07-01 13:20:12","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"R","title":"Documents, reports","displayCode":"\/Documents, reports","attributes":{"classification":"deliverableType","type":"isDeliveredAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"language":"en","availableLanguages":"en","defaultLanguage":"en","id":"cdf7bde7bca4b9983bf9e01bbec9a32f","physUrl":"https:\/\/ec.europa.eu\/research\/participants\/documents\/downloadPublic?documentIds=080166e50493f204\u0026appId=PPGMS","contenttype":"webLink","attributes":{"source":"corda","type":"projectDeliverable"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"721951","id":"869929_1_DELIV","title":"Specifications for virtual demonstration cases","description":"Report with a definition and specification of representative virtual buildings for which the Energy Saving Potential of Switch2Save Technology will be modelled, calculated and optimised through active switching protocols.","sourceUpdateDate":"2021-09-23 13:00:56","contentUpdateDate":"2021-09-24 21:16:34","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"R","title":"Documents, reports","displayCode":"\/Documents, reports","attributes":{"classification":"deliverableType","type":"isDeliveredAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"language":"en","availableLanguages":"en","defaultLanguage":"en","id":"70772b2654d9de69206b52bb8fcaecbe","physUrl":"https:\/\/ec.europa.eu\/research\/participants\/documents\/downloadPublic?documentIds=080166e5cd89b296\u0026appId=PPGMS","contenttype":"webLink","attributes":{"represents":"project","source":"corda","type":"projectDeliverable"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"1124746","id":"869929_26_DELIV","title":"Long term assessment of the visual comfort achieved by the IGUs","description":"Report on visual comfort assessment of the Switch2Save IGUs determined in measurements in the Mockup-Building at NTUA campus","sourceUpdateDate":"2024-06-29 00:27:23","contentUpdateDate":"2024-07-01 13:20:10","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"R","title":"Documents, reports","displayCode":"\/Documents, reports","attributes":{"classification":"deliverableType","type":"isDeliveredAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"language":"en","availableLanguages":"en","defaultLanguage":"en","id":"31df5646b85a8f474a27340d11c8bf93","physUrl":"https:\/\/ec.europa.eu\/research\/participants\/documents\/downloadPublic?documentIds=080166e502113815\u0026appId=PPGMS","contenttype":"webLink","attributes":{"source":"corda","type":"projectDeliverable"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"1124747","id":"869929_30_DELIV","title":"Monitoring of the Hospital\u0027s clinic performance after to the installation of IGUs: A comparison assessment","description":"Report on Energy Demand data of the Hospital Clinics  for one year after installing the Switch2Save windows and balcony doors including temperature levels, energy consumption for heating and energy consumption for cooling","sourceUpdateDate":"2024-06-29 00:27:23","contentUpdateDate":"2024-07-01 13:20:10","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"R","title":"Documents, reports","displayCode":"\/Documents, reports","attributes":{"classification":"deliverableType","type":"isDeliveredAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"language":"en","availableLanguages":"en","defaultLanguage":"en","id":"7609d41f9be1cc7b9c0f103cacda616c","physUrl":"https:\/\/ec.europa.eu\/research\/participants\/documents\/downloadPublic?documentIds=080166e504c3618c\u0026appId=PPGMS","contenttype":"webLink","attributes":{"source":"corda","type":"projectDeliverable"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"1124756","id":"869929_49_DELIV","title":"Architectural design competition awardee selection","description":"Report on the list of submitted projects to the design competition, selection criteria, evaluation results, and the winners","sourceUpdateDate":"2024-06-29 00:27:23","contentUpdateDate":"2024-07-01 13:20:12","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"R","title":"Documents, reports","displayCode":"\/Documents, reports","attributes":{"classification":"deliverableType","type":"isDeliveredAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"language":"en","availableLanguages":"en","defaultLanguage":"en","id":"f2e82a6bda453f3cda5191aa71e5d362","physUrl":"https:\/\/ec.europa.eu\/research\/participants\/documents\/downloadPublic?documentIds=080166e5fc1a026b\u0026appId=PPGMS","contenttype":"webLink","attributes":{"source":"corda","type":"projectDeliverable"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"1124750","id":"869929_34_DELIV","title":"Toolbox of IGU configurations with energy saving data for various building typologies and climatic zones","description":"Publicly available report proposed Energy Smart IGU configurations, switching protocol and simulated energy demand data for the Virtual Demo Buildings described in D7.5. The Report will as well include data to be used for design of buildings with standard architectural softwares (BIM Files \/ datasets for each of the proposed configurations)","sourceUpdateDate":"2024-06-29 00:27:23","contentUpdateDate":"2024-07-01 13:20:12","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"R","title":"Documents, reports","displayCode":"\/Documents, reports","attributes":{"classification":"deliverableType","type":"isDeliveredAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"language":"en","availableLanguages":"en","defaultLanguage":"en","id":"af521f721d761282a2549dfa7c6e1c57","physUrl":"https:\/\/ec.europa.eu\/research\/participants\/documents\/downloadPublic?documentIds=080166e501335771\u0026appId=PPGMS","contenttype":"webLink","attributes":{"source":"corda","type":"projectDeliverable"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"1005068","id":"869929_1980472_PUBLI","title":"Photochemical Precharging of Tungsten Trioxide for Enhanced Transmittance Modulation in Flexible Electrochromic Devices","details":"\r\n    \u003Cauthors\u003EL. Br\u00e4ndler, L. Niklaus, M. Schott (corresponding), P. L\u00f6bmann\u003C\/authors\u003E\r\n    \u003CjournalNumber \/\u003E\r\n    \u003CjournalTitle\u003EAdvanced Materials Technologies\u003C\/journalTitle\u003E\r\n    \u003CpublishedPages \/\u003E\r\n    \u003CpublishedYear\u003E2023\u003C\/publishedYear\u003E\r\n    \u003Cpublisher\u003EWiley\u003C\/publisher\u003E\r\n  ","identifiers":{"doi":"10.1002\/admt.202201903","issn":["2365-709X"]},"sourceUpdateDate":"2023-11-28 10:39:20","contentUpdateDate":"2023-12-04 10:45:16","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"publication","title":"Project publication","description":"Result: Project publications","displayCode":"\/Project publication","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"PEER_REVIEWED_ARTICLE","title":"Peer reviewed articles","displayCode":"\/Peer reviewed articles","attributes":{"classification":"projectPublication","type":"isPublishedAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"726133","id":"869929_1042434_PUBLI","title":"Energy Savings in an Office Building with High WWR Using Glazing Systems Combining Thermochromic and Electrochromic Layers","details":"\r\n    \u003Cauthors\u003EMichaela Detsi, Aris Manolitsis, Ioannis Atsonios, Ioannis Mandilaras, Maria Founti\u003C\/authors\u003E\r\n    \u003CjournalNumber\u003E13\/11\u003C\/journalNumber\u003E\r\n    \u003CjournalTitle\u003EEnergies\u003C\/journalTitle\u003E\r\n    \u003CpublishedPages\u003E3020\u003C\/publishedPages\u003E\r\n    \u003CpublishedYear\u003E2020\u003C\/publishedYear\u003E\r\n    \u003Cpublisher\u003EMultidisciplinary Digital Publishing Institute (MDPI)\u003C\/publisher\u003E\r\n  ","identifiers":{"doi":"10.3390\/en13113020","issn":["1996-1073"]},"sourceUpdateDate":"2021-05-29 08:52:43","contentUpdateDate":"2021-10-01 15:38:49","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"publication","title":"Project publication","description":"Result: Project publications","displayCode":"\/Project publication","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"PEER_REVIEWED_ARTICLE","title":"Peer reviewed articles","displayCode":"\/Peer reviewed articles","attributes":{"classification":"projectPublication","type":"isPublishedAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"1124743","id":"869929_31_DELIV","title":"Energy consumption and shading state of the office building before facade upgrades","description":"Report on Energy Demand data related to the Position data of the external window blinds and the indoor illumination data of the Uppsala office building for one year based on the currently installed windows and window blinds including temperature levels, energy consumption for heating and energy consumption for cooling","sourceUpdateDate":"2024-06-29 00:27:23","contentUpdateDate":"2024-07-01 13:20:10","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"R","title":"Documents, reports","displayCode":"\/Documents, reports","attributes":{"classification":"deliverableType","type":"isDeliveredAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"language":"en","availableLanguages":"en","defaultLanguage":"en","id":"2dd504c46b03b3c9b3381c81b89ac7a1","physUrl":"https:\/\/ec.europa.eu\/research\/participants\/documents\/downloadPublic?documentIds=080166e5f6830b5b\u0026appId=PPGMS","contenttype":"webLink","attributes":{"source":"corda","type":"projectDeliverable"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"1124749","id":"869929_32_DELIV","title":"Energy consumption, EC switching state protocols after facade upgrade including comparative assessment","description":"Report on Energy Demand data related the indoor illumination data of the Uppsala office building for one year after installing the Switch2Save Fa\u00e7ade elements including temperature levels, energy consumption for heating and energy consumption for cooling","sourceUpdateDate":"2024-06-29 00:27:23","contentUpdateDate":"2024-07-01 13:20:11","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"R","title":"Documents, reports","displayCode":"\/Documents, reports","attributes":{"classification":"deliverableType","type":"isDeliveredAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"language":"en","availableLanguages":"en","defaultLanguage":"en","id":"66d8149324b978d7819e4aac196aa617","physUrl":"https:\/\/ec.europa.eu\/research\/participants\/documents\/downloadPublic?documentIds=080166e50594234c\u0026appId=PPGMS","contenttype":"webLink","attributes":{"source":"corda","type":"projectDeliverable"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}},{"availableLanguages":"en","rcn":"1005081","id":"869929_1980441_PUBLI","title":"Energy \u2013 Comfort \u2013 Environment: What matters most? A multi-criteria assessment of a residential apartment","details":"\r\n    \u003Cauthors\u003EA Manolitsis; A Zacharis; I Atsonios; M Detsi; A Bonou; M Stamatiadou; I Mandilaras; M Founti\u003C\/authors\u003E\r\n    \u003CjournalNumber\u003E5\u003C\/journalNumber\u003E\r\n    \u003CjournalTitle\u003ECrossref\u003C\/journalTitle\u003E\r\n    \u003CpublishedPages \/\u003E\r\n    \u003CpublishedYear\u003E2022\u003C\/publishedYear\u003E\r\n    \u003Cpublisher\u003ESBE-BERLIN-2022\u003C\/publisher\u003E\r\n  ","identifiers":{"doi":"10.1088\/1755-1315\/1078\/1\/012098"},"sourceUpdateDate":"2023-11-28 10:39:20","contentUpdateDate":"2023-12-04 10:45:19","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"publication","title":"Project publication","description":"Result: Project publications","displayCode":"\/Project publication","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"CONFERENCE_PROCEEDING","title":"Conference proceedings","displayCode":"\/Conference proceedings","attributes":{"classification":"projectPublication","type":"isPublishedAs"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"result","attributes":{"source":"corda","type":"relatedResult"}}],"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/63\/19232965","title":"amorphous solids","displayCode":"\/engineering and technology\/materials engineering\/amorphous solids","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"IA","title":"Innovation action","description":"Innovation action","displayCode":"\/Innovation action","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"modelVersion":"132","icaVersion":"20.0.0-48f81e07"}