{"contenttype":"project","language":"en","availableLanguages":"en","rcn":"54374","id":"ENK5-CT-1999-00002","acronym":"CORROSION","teaser":"Objectives and problems to be solved: N2O is a powerful greenhouse gas and a precursor of stratospheric ozone depletion. NOx are also responsible for acid rain and photochemical smog. Combustion technology is an important source of both pollutants. The main objective is the de...","objective":"Objectives and problems to be solved: N2O is a powerful greenhouse gas and a precursor of stratospheric ozone depletion. NOx are also responsible for acid rain and photochemical smog. Combustion technology is an important source of both pollutants. The main objective is the development of an advanced, compact, efficient and cost-effective technology, based on the simultaneous selective catalytic reduction of N2O and NOx from combustion power plants by hydrocarbons. This will enable companies to comply with legal regulations at a reasonable cost while an environmental friendly image is created. The project deals with the development\/ improvement of active and selective catalysts stable over a meaningful time of continuous operation and with the acquisition of a fundamental understanding of process kinetics and mechanisms. Description of work: The proposed work comprises the following tasks:\n\u00b7 Catalyst Design and synthesis, including preparation of different type of supported and unsupported active catalysts, such as zeolite, clay, carbon, and metal\/metal oxide based catalysts, in the form of powders, pellets, extrudates or monoliths.\n\u00b7 Lab-scale testing, which consists of different screening tests for assessment of the catalyst activity and selectivity. Experiments are also foreseen in order to understand the basic scientific phenomena such as reaction kinetics, mechanisms of reaction and the mechanisms of inhibition and deactivation over the catalysts.\n\u00b7 Catalysts Characterisation, using a series of physicochemical techniques, in order to:\na) ensure the effectiveness of preparation and the homogeneity and reproducibility of the fresh samples,\nb) seek insights into deactivation of the catalysts and\nc) gauge the effect of potential poisoning on used samples.\n\u00b7 Bench-scale testing aimed at the assessment of the lifetime of the catalysts. Two different tests, using simulated combustion gases, are designed for this purpose:\na) accelerated deactivation tests, to simulate any possible deactivation of catalysts during their exposure to real combustion exhaust gases and\nb) long-term stability tests (up to 2000 hours) simulating the clean up of flue gases in conditions as close as possible to those found in industrial applications. Eventually, the performance of the catalysts will be evaluated with real combustion off-gases. Expected Results and Exploitation Plans:\n\u00b7 The development of selective, active, stable and durable catalyst prototypes, potentially transferable to various industrial user groups. This will put European industry in a position to offer an efficient, economic and advanced technique for the simultaneous removal of N2O and NOx in off-gas from combustion processes.\n\u00b7 The acquisition of deep knowledge of the nature of selective catalytic reduction of N2O\/NOx by hydrocarbons. This should directly influence scientific and technological level throughout Europe and will bring about significant progress in the field of heterogeneous catalytic denoxing of exhaust gases from stationary combustion sources, and thus accelerate the discovery of technically relevant solutions.\nThe laboratory and combustion rig, corrosion test campaigns produced extensive information on the behaviour of a wide range of materials tested under a variety of conditions. The results provided an approximation of how these materials would perform in environments arising from a range of coal-firing conditions, in situations where biomass and waste materials were fired and co-firing of biomass and waste materials with coal. The data from the 40 MWth test boiler was unique in that it provided corrosion information for a suite of superheater materials exposed in real conditions, which were controlled within a desired temperature range. This work produced detailed information on the corrosion effects arising from the combustion of coal, and the co-combustion of coal with olive husks and coal with meat and bone meal, on the test materials. The test programme completed on the 30 MWth CFB boiler supplied information on corrosion mechanisms that affect superheater materials in biomass fired, circulating, fluidised bed boiler plant, and provided details of some possible remedial measures.\n\nThe effects of corrosion on a variety of candidate materials and coated materials were investigated during long-term probe tests, and following a detailed examination of the test specimens, an assessment of the suitability of individual materials and coatings was provided. The effects of fireside additives at reducing corrosive atmospheres were considered during short-term trials involving the addition of sulphur, kaolin and a test mixture to the supplied fuel. The test mixture additive was the most effective with no adverse effects. The addition of Sulphur was aloe effective, however there was also an increase in SO2 present in the flue gas, which could contribute to an increase in low temperature corrosion. The information from the lab and combustion rig experiments, and the industrial scale tests, were collated and compared in order to identify relationships between small-scale investigations and those conducted in industrial plant. These results were used to prepare a report, which provides a consensus view of the current state of knowledge of corrosion mechanisms which apply in superheater and reheater conditions operating at advanced steam conditions, furnace sidewall tubes exposed to conditions associated with advanced primary NOx control technologies, and superheater and reheater elements in boilers fired with biomass\/waste materials and the co-firing of these materials. The report includes valuable corrosion rate data of relevant boiler tube materials under gas side conditions associated with these operating conditions.\n\nA total of 5 diagnostic techniques were developed during the project, viz. 1. Two types of bolt-like probes, which are used for directly measuring corrosion rates at desired locations in the furnace and superheater regions of a boiler, were developed. These devices are inexpensive, simple to operate and provide an accurate corrosion rate determination, based on metal wastage measurement for periods of around 8,00 hours. 2. Two types of probes, which provide corrosion rate data, based on electrochemical measurements. These devices were not completely proven during this project, however there was sufficient evidence to suggest that both have potential for commercial application. 3. A probe device, which makes metal thickness measurements based on a pyrometric technique. Notable progress was achieved, but the system still requires further work before it can be tested on a commercial boiler. A computer model based on CCSEM fly ash data and Computational Fluid Dynamics, to predict fireside deposition and corrosion in coal-fired utility boilers was developed. The model consists of a number of components, each of which address a specific activity including, volatile matter species release from host particles, gas phase chemical reactions, mineral matter transformation, particle dispersion, particle deposition on furnace walls and heat transfer tubes, and flow within the tube bank zones and rate of corrosion build up.\n\nAll of the experience and knowledge gained from the project was used to produce a guideline document, which provides an overview of the current state of knowledge of high temperature corrosion occurring in advanced coal-fired plant, relevant to the following scenarios: 1. The operation of superheater and reheater elements at advanced steam conditions. 2. The deployment of advanced primary NOx reduction technologies in utility boilers. 3. The combustion of biomass and waste materials and the co-firing of these materials with coal. This document provides authoritative and quantitative information and guidance on the interpretation and use of the information by boiler designers and operators.\n","title":"Fireside corrosion in coal-fired utility boilers (CORROSION)","totalCost":"3341355","ecMaxContribution":"1728418","startDate":"2000-05-01","endDate":"2003-10-31","validation":{"euroSciVoc":"false"},"contentCreationDate":"2001-03-16 00:00:00","contentUpdateDate":"2025-09-01 22:04:37","lastUpdateDate":"2026-02-18 16:58:40","archivedDate":"2024-05-21 00:00:00","relations":{"associations":[{"availableLanguages":"de,en,es,fr,it","rcn":"81741","id":"81741-early-fireside-corrosion-detection","title":"Early fireside corrosion detection","teaser":"A new sensor that measures fireside corrosion rates has been developed and demonstrated in power plant boilers.","contentUpdateDate":"2005-09-18 17:51:03","archivedDate":"2024-06-10 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"ener","title":"Energy","displayCode":"\/Energy","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"brief","title":"Result in Brief","description":"Article: Classic and enhanced","displayCode":"\/Result in Brief","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"language":"en","availableLanguages":"en,any","uri":"\/docs\/results\/images\/2005-09\/33048.jpg","mimetype":"image\/jpeg","size":"0","copyright":"\u00a9 Corel","contenttype":"webItem","attributes":{"represents":"article","source":"editorial","type":"relatedImage"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"relatedArticle"}},{"availableLanguages":"en","rcn":"263469","legalName":"MITSUI BABCOCK ENERGY LTD*","address":{"street":"Porterfield Road","city":"RENFREW","postalCode":"PA4 8DJ","country":"UK"},"relations":{"regions":[{"name":"United Kingdom","rcn":"508725800","nutsCode":"UK","euCode":"UK","isoCode":"GB","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"coordinator","order":"1"}},{"availableLanguages":"en","rcn":"358154","legalName":"UNIVERSITAET STUTTGART","address":{"street":"Pfaffenwaldring 23","city":"STUTTGART","postalCode":"70569","country":"DE"},"relations":{"regions":[{"name":"Germany","rcn":"221940264","nutsCode":"DE","euCode":"DE","isoCode":"DE","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"participant","order":"5"}},{"availableLanguages":"en","rcn":"358735","legalName":"VATTENFALL AB","address":{"street":"Laemtlandsgatan 99","city":"STOCKHOLM","postalCode":"162 87","country":"SE","url":"http:\/\/www.vattenfall.se"},"relations":{"regions":[{"name":"Sweden","rcn":"473598504","nutsCode":"SE","euCode":"SE","isoCode":"SE","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"participant","order":"6"}},{"availableLanguages":"en","rcn":"753099","legalName":"CINAR LTD.","address":{"street":"Elvaston Place 11","city":"LONDON","postalCode":"SW7 5QG","country":"UK"},"relations":{"regions":[{"name":"United Kingdom","rcn":"508725800","nutsCode":"UK","euCode":"UK","isoCode":"GB","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"participant","order":"4"}},{"availableLanguages":"en","rcn":"799774","legalName":"CESI - CENTRO ELETTROTECNICO SPERIMENTALE ITALIANO GIACINTO MOTTA SPA","address":{"street":"Via Rubattino 54","city":"MILANO","postalCode":"20134","country":"IT"},"relations":{"regions":[{"name":"Italy","rcn":"309758504","nutsCode":"IT","euCode":"IT","isoCode":"IT","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"participant","order":"3"}},{"availableLanguages":"en","rcn":"799775","legalName":"ANSALDO ENERGIA SPA","address":{"street":"Piazza Monumento, 12","city":"LEGNANO","postalCode":"20025","country":"IT"},"relations":{"regions":[{"name":"Italy","rcn":"309758504","nutsCode":"IT","euCode":"IT","isoCode":"IT","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"participant","order":"2"}},{"availableLanguages":"de,en,es,fr,it","rcn":"643","id":"FP5-EESD","code":"FP5-EESD","frameworkProgramme":"FP5","pga":"FP5-EESD","title":"Programme for research, technological development and demonstration on \u0022Energy, environment and sustainable development, 1998-2002\u0022","shortTitle":"Energy, environment and sustainable development","parent":{"rcn":"624","code":"FP5"},"archivedDate":"2023-03-27 11:33:43","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"legalbasis","title":"Legal Basis","description":"Programme: Legal basis for research funding","displayCode":"\/Legal Basis","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedLegalBasis"}},{"availableLanguages":"en","rcn":"6110","id":"FP5-EESD_1.1.4.-5.","code":"1.1.4.-5.","frameworkProgramme":"FP5","title":"Key action Cleaner Energy Systems, including Renewable Energies","parent":{"rcn":"643\/624","code":"FP5-EESD\/FP5"},"archivedDate":"2023-03-27 11:33:43","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"topic","title":"Topic","description":"Programme: Part of the Commission work programme implementing legal basis","displayCode":"\/Topic","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedTopic"}},{"availableLanguages":"en","rcn":"33047","id":"ENK5-CT-1999-00002_33047_DELIV","title":"Use of fuel additives during biomass combustion to change deposit chemistry at superheaters","teaser":"This result concerns the outcome of short-term corrosion tests in a wood-fired circulating fluidised bed (CFB) boiler. The experiments were carried out in connection with the use of fuel additives for corrosion inhibition. The additives selected were kaolin, sulphur and an exp...","sourceUpdateDate":"2017-02-14 17:46:52","contentUpdateDate":"2004-07-29 00:00:00","archivedDate":"2024-06-20 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"eTip","title":"e-TIP","description":"FP5 reporting system (CORDIS application)","displayCode":"\/e-TIP","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"3128025","legalName":"Vattenfall Ab","address":{"street":"Jaemtlandsgatan 99","city":"Stockholm","postalCode":"162 87","country":"SE","url":"http:\/\/www.vattenfall.se"},"relations":{"regions":[{"name":"Sweden","rcn":"473598504","nutsCode":"SE","euCode":"SE","isoCode":"SE","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"eTip","type":"relatedOrganization"}}]},"contenttype":"result","attributes":{"source":"eTip","type":"relatedResult"}},{"availableLanguages":"en","rcn":"33037","id":"ENK5-CT-1999-00002_33037_DELIV","title":"Performance trials of an on-line corrosion rate monitoring probe","teaser":"During this project CESI was devoted to the development and qualification of a monitoring device able to measure the corrosion behaviour of the boiler materials on-line. CESI has contributed to this task with the design, construction and testing of a corrosion probe based on t...","sourceUpdateDate":"2017-02-14 17:46:47","contentUpdateDate":"2004-07-29 00:00:00","archivedDate":"2024-06-20 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"en","code":"id14","title":"Prototype\/demonstrator available for testing","attributes":{"classification":"resultDevelopmentStage","type":"relatedResultDevelopmentStage"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"eTip","title":"e-TIP","description":"FP5 reporting system (CORDIS application)","displayCode":"\/e-TIP","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"3128015","legalName":"Centro Elettrotecnico Sperimentale Italiano Giacinto Motta SpA (CESI)","address":{"street":"Via Rubattino 54","city":"Milano","postalCode":"20134","country":"IT","url":"http:\/\/www.cesi.it"},"relations":{"regions":[{"name":"Italy","rcn":"309758504","nutsCode":"IT","euCode":"IT","isoCode":"IT","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"eTip","type":"relatedOrganization"}}]},"contenttype":"result","attributes":{"source":"eTip","type":"relatedResult"}},{"availableLanguages":"en","rcn":"33043","id":"ENK5-CT-1999-00002_33043_DELIV","title":"Small scale combustion rig corrosion tests","teaser":"Two co-firing combustion test series were carried out in a 0,5MW combustion rig: The first one is: \n- Co-firing lignite with high ash paper sludge and compost and \n\n- Co-firing bituminous coal with olive husk. \n\nThe possibility of fireside corrosion by co-firing was predicted ...","sourceUpdateDate":"2017-02-14 17:46:50","contentUpdateDate":"2004-07-29 00:00:00","archivedDate":"2024-06-20 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"en","code":"id17","title":"Scientific and\/or technical knowledge (basic research)","attributes":{"classification":"resultDevelopmentStage","type":"relatedResultDevelopmentStage"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"eTip","title":"e-TIP","description":"FP5 reporting system (CORDIS application)","displayCode":"\/e-TIP","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"3128021","legalName":"Institute for Process Engineering and Power Plant Technology (IVD), University Stuttgart.","address":{"street":"Pfaffenwaldring 23","city":"STUTTGART","postalCode":"70569","country":"DE","url":"http:\/\/www.ivd.uni-stuttgart.de"},"relations":{"regions":[{"name":"Germany","rcn":"221940264","nutsCode":"DE","euCode":"DE","isoCode":"DE","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"eTip","type":"relatedOrganization"}}]},"contenttype":"result","attributes":{"source":"eTip","type":"relatedResult"}},{"availableLanguages":"en","rcn":"33049","id":"ENK5-CT-1999-00002_33049_DELIV","title":"Laboratory-scale corrosion tests","teaser":"Corrosion mechanism and the influence of gas atmosphere and ash deposits on fire-side corrosion rate were investigated. Thin plates of more than 10 different metal specimens with chromium content between 1 and 24% were exposed in oxidising and reducing atmosphere containing HC...","sourceUpdateDate":"2017-02-14 17:46:53","contentUpdateDate":"2004-07-29 00:00:00","archivedDate":"2024-06-20 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"en","code":"id17","title":"Scientific and\/or technical knowledge (basic research)","attributes":{"classification":"resultDevelopmentStage","type":"relatedResultDevelopmentStage"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"eTip","title":"e-TIP","description":"FP5 reporting system (CORDIS application)","displayCode":"\/e-TIP","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"3128027","legalName":"Institute for Process Engineering and Power Plant Technology (IVD), University Stuttgart.","address":{"street":"Pfaffenwaldring 23","city":"STUTTGART","postalCode":"70569","country":"DE","url":"http:\/\/www.ivd.uni-stuttgart.de"},"relations":{"regions":[{"name":"Germany","rcn":"221940264","nutsCode":"DE","euCode":"DE","isoCode":"DE","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"eTip","type":"relatedOrganization"}}]},"contenttype":"result","attributes":{"source":"eTip","type":"relatedResult"}},{"availableLanguages":"en","rcn":"33038","id":"ENK5-CT-1999-00002_33038_DELIV","title":"Thermodynamic calculation with FACT-sage","teaser":"The suitability of co-firing bituminous coal or lignite with straw is predicted, and furthermore, up to which thermal share of straw in the co-combustion is acceptable against serious fireside corrosion. \n\nAlumino-silca rich coals such as bituminous coals are more suitable to ...","sourceUpdateDate":"2017-02-14 17:46:48","contentUpdateDate":"2004-07-29 00:00:00","archivedDate":"2024-06-20 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"eTip","title":"e-TIP","description":"FP5 reporting system (CORDIS application)","displayCode":"\/e-TIP","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"3128016","legalName":"Institute for Process Engineering and Power Plant Technology (IVD), University Stuttgart.","address":{"street":"Pfaffenwaldring 23","city":"STUTTGART","postalCode":"70569","country":"DE","url":"http:\/\/www.ivd.uni-stuttgart.de"},"relations":{"regions":[{"name":"Germany","rcn":"221940264","nutsCode":"DE","euCode":"DE","isoCode":"DE","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"eTip","type":"relatedOrganization"}}]},"contenttype":"result","attributes":{"source":"eTip","type":"relatedResult"}},{"availableLanguages":"en","rcn":"33035","id":"ENK5-CT-1999-00002_33035_DELIV","title":"Development\/demonstration of the on-line electrochemical fireside corrosion monitor","teaser":"The aim of the CORROSION project was to develop an on-line electrochemical fireside corrosion monitor and demonstrate it at the Hemweg 8 coal fired power plant. The on-line electrochemical corrosion probes was successfully demonstrated in the boiler of the Hemweg 8 power plant...","sourceUpdateDate":"2017-02-14 17:46:47","contentUpdateDate":"2004-07-29 00:00:00","archivedDate":"2024-06-20 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"en","code":"id15","title":"Results of demonstration trials available","displayCode":"\/Results of demonstration trials available","attributes":{"classification":"resultDevelopmentStage","type":"relatedResultDevelopmentStage"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"eTip","title":"e-TIP","description":"FP5 reporting system (CORDIS application)","displayCode":"\/e-TIP","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"3128013","legalName":"Kema Nederland BV","address":{"street":"Utrechtseweg 310","city":"Arnhem","postalCode":"6812 AR","country":"NL","url":"http:\/\/www.kema.com\/nl\/"},"relations":{"regions":[{"name":"Netherlands","rcn":"391547432","nutsCode":"NL","euCode":"NL","isoCode":"NL","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"eTip","type":"relatedOrganization"}}]},"contenttype":"result","attributes":{"source":"eTip","type":"relatedResult"}},{"availableLanguages":"en","rcn":"33040","id":"ENK5-CT-1999-00002_33040_DELIV","title":"Corrosion probe\/sniffer port development","teaser":"The objective of Mitsui Babcock was the development and site demonstration of a corrosion probe-sniffer port assembly for the investigation of furnace wall corrosion in large coal-fired boilers.\n\nThe Mitsui Babcock corrosion probe is a simple and inexpensive device, which is d...","sourceUpdateDate":"2017-02-14 17:46:49","contentUpdateDate":"2004-07-29 00:00:00","archivedDate":"2024-06-20 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"en","code":"id15","title":"Results of demonstration trials available","displayCode":"\/Results of demonstration trials available","attributes":{"classification":"resultDevelopmentStage","type":"relatedResultDevelopmentStage"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"eTip","title":"e-TIP","description":"FP5 reporting system (CORDIS application)","displayCode":"\/e-TIP","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"3128018","legalName":"Mitsui Babcock","address":{"street":"Porterfield Road, Renfrew","city":"Glasgow","postalCode":"PA4 8DJ","country":"UK","url":"http:\/\/www.mitsuibabcock.com"},"relations":{"regions":[{"name":"United Kingdom","rcn":"508725800","nutsCode":"UK","euCode":"UK","isoCode":"GB","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"eTip","type":"relatedOrganization"}}]},"contenttype":"result","attributes":{"source":"eTip","type":"relatedResult"}},{"availableLanguages":"en","rcn":"33046","id":"ENK5-CT-1999-00002_33046_DELIV","title":"Co-firing system performance analysis and tuning","teaser":"Coal and biomass (olive husk and meat \u0026 bone meal) have been burnt in \u0027co-firing mode\u0027. A burner able to operate with coal alone and with different percentages of biomass replacing coal heat input was set-up and experimented. The most important combustion parameters were inves...","sourceUpdateDate":"2017-02-14 17:46:51","contentUpdateDate":"2004-07-29 00:00:00","archivedDate":"2024-06-20 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"en","code":"id15","title":"Results of demonstration trials available","displayCode":"\/Results of demonstration trials available","attributes":{"classification":"resultDevelopmentStage","type":"relatedResultDevelopmentStage"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"eTip","title":"e-TIP","description":"FP5 reporting system (CORDIS application)","displayCode":"\/e-TIP","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"3128024","legalName":"Ansaldo Caldaie S.p.A","address":{"street":"Largo Buffoni, 3","city":"Gallarate","postalCode":"21013","country":"IT","url":"http:\/\/www.ansaldoboiler.it"},"relations":{"regions":[{"name":"Italy","rcn":"309758504","nutsCode":"IT","euCode":"IT","isoCode":"IT","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"eTip","type":"relatedOrganization"}}]},"contenttype":"result","attributes":{"source":"eTip","type":"relatedResult"}},{"availableLanguages":"en","rcn":"33044","id":"ENK5-CT-1999-00002_33044_DELIV","title":"Corrosion monitoring\/material testing with the KEMA corrosion probe","teaser":"The KEMCOP corrosion and fouling monitoring system (patent pending) consists of small probes, which are installed, in the strips between the tubes of the membrane walls. A total number of 64 KEMCOP\u0092s were installed at the Maasvlakte powerplant in the Netherlands in order to de...","sourceUpdateDate":"2017-02-14 17:46:51","contentUpdateDate":"2004-07-29 00:00:00","archivedDate":"2024-06-20 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"en","code":"id15","title":"Results of demonstration trials available","displayCode":"\/Results of demonstration trials available","attributes":{"classification":"resultDevelopmentStage","type":"relatedResultDevelopmentStage"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"eTip","title":"e-TIP","description":"FP5 reporting system (CORDIS application)","displayCode":"\/e-TIP","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"3128022","legalName":"Kema Nederland BV","address":{"street":"Utrechtseweg 310","city":"Arnhem","postalCode":"6812 AR","country":"NL","url":"http:\/\/www.kema.com\/nl\/"},"relations":{"regions":[{"name":"Netherlands","rcn":"391547432","nutsCode":"NL","euCode":"NL","isoCode":"NL","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"eTip","type":"relatedOrganization"}}]},"contenttype":"result","attributes":{"source":"eTip","type":"relatedResult"}},{"availableLanguages":"en","rcn":"33039","id":"ENK5-CT-1999-00002_33039_DELIV","title":"Mathematical model to predict slagging, fouling and corrosion in utility boiler flames","teaser":"The formation of ash, vapour phase species causes various problems to the boiler utility ranging from ash deposition and corrosion in the furnace walls\/boiler tubes to unplanned shut down. The work presented here focused on developing a mathematical model to predict surface fo...","sourceUpdateDate":"2017-02-14 17:46:48","contentUpdateDate":"2004-07-29 00:00:00","archivedDate":"2024-06-20 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"en","code":"id15","title":"Results of demonstration trials available","displayCode":"\/Results of demonstration trials available","attributes":{"classification":"resultDevelopmentStage","type":"relatedResultDevelopmentStage"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"eTip","title":"e-TIP","description":"FP5 reporting system (CORDIS application)","displayCode":"\/e-TIP","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"3128017","legalName":"CINAR LTD.","address":{"street":"11,Elvaston Place 11","city":"LONDON","postalCode":"SW7 5QG","country":"UK","url":"http:\/\/www.cinar.co.uk"},"relations":{"regions":[{"name":"United Kingdom","rcn":"508725800","nutsCode":"UK","euCode":"UK","isoCode":"GB","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"eTip","type":"relatedOrganization"}}]},"contenttype":"result","attributes":{"source":"eTip","type":"relatedResult"}},{"availableLanguages":"en","rcn":"33041","id":"ENK5-CT-1999-00002_33041_DELIV","title":"Corrosion\/ash chemistry data synthesis report","teaser":"The report concerns a detailed and critical examination of the corrosion trial work conducted in laboratory, small-scale combustion test rig and industrial scale facilities. It attempts to develop correlations between the results of the work performed at different scales, and ...","sourceUpdateDate":"2017-02-14 17:46:49","contentUpdateDate":"2004-07-29 00:00:00","archivedDate":"2024-06-20 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"en","code":"id17","title":"Scientific and\/or technical knowledge (basic research)","attributes":{"classification":"resultDevelopmentStage","type":"relatedResultDevelopmentStage"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"eTip","title":"e-TIP","description":"FP5 reporting system (CORDIS application)","displayCode":"\/e-TIP","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"3128019","legalName":"Mitsui Babcock","address":{"street":"Porterfield Road, Renfrew","city":"Glasgow","postalCode":"PA4 8DJ","country":"UK","url":"http:\/\/www.mitsuibabcock.com"},"relations":{"regions":[{"name":"United Kingdom","rcn":"508725800","nutsCode":"UK","euCode":"UK","isoCode":"GB","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"eTip","type":"relatedOrganization"}}]},"contenttype":"result","attributes":{"source":"eTip","type":"relatedResult"}},{"availableLanguages":"en","rcn":"33051","id":"ENK5-CT-1999-00002_33051_DELIV","title":"Design and operational guidelines","teaser":"Using all of the information and experiences gained from the CORROSION-project, a design and operational guideline document was produced. The report details the current state of knowledge of fireside corrosion, and covers the following subject areas:\n- Advice on the impact of...","sourceUpdateDate":"2017-02-14 17:46:53","contentUpdateDate":"2004-12-09 00:00:00","archivedDate":"2024-06-20 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"en","code":"id26","title":"Guidelines, methodologies, technical drawings","displayCode":"\/Guidelines, methodologies, technical drawings","attributes":{"classification":"resultDevelopmentStage","type":"relatedResultDevelopmentStage"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"eTip","title":"e-TIP","description":"FP5 reporting system (CORDIS application)","displayCode":"\/e-TIP","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"3128029","legalName":"Mitsui Babcock","address":{"street":"Porterfield Road, Renfrew","city":"Glasgow","postalCode":"PA4 8DJ","country":"UK","url":"http:\/\/www.mitsuibabcock.com"},"relations":{"regions":[{"name":"United Kingdom","rcn":"508725800","nutsCode":"UK","euCode":"UK","isoCode":"GB","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"eTip","type":"relatedOrganization"}}]},"contenttype":"result","attributes":{"source":"eTip","type":"relatedResult"}},{"availableLanguages":"en","rcn":"33042","id":"ENK5-CT-1999-00002_33042_DELIV","title":"Laboratory-scale corrosion results in an oxodising atmosphere","teaser":"This result involved the completion of a series of laboratory-scale experiments that were concerned with the measurement of corrosion rates of a number of boiler tube materials, both conventional and novel, under strictly controlled conditions. The laboratory-scale corrosion e...","sourceUpdateDate":"2017-02-14 17:46:49","contentUpdateDate":"2004-07-29 00:00:00","archivedDate":"2024-06-20 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"en","code":"id17","title":"Scientific and\/or technical knowledge (basic research)","attributes":{"classification":"resultDevelopmentStage","type":"relatedResultDevelopmentStage"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"eTip","title":"e-TIP","description":"FP5 reporting system (CORDIS application)","displayCode":"\/e-TIP","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"3128020","legalName":"Mitsui Babcock","address":{"street":"Porterfield Road, Renfrew","city":"Glasgow","postalCode":"PA4 8DJ","country":"UK","url":"http:\/\/www.mitsuibabcock.com"},"relations":{"regions":[{"name":"United Kingdom","rcn":"508725800","nutsCode":"UK","euCode":"UK","isoCode":"GB","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"eTip","type":"relatedOrganization"}}]},"contenttype":"result","attributes":{"source":"eTip","type":"relatedResult"}},{"availableLanguages":"en","rcn":"33048","id":"ENK5-CT-1999-00002_33048_DELIV","title":"Proof of principle of the semi on-line corrosion probe based on the KEMCOP design","teaser":"This sensor measures the thickness of a metal foil that is attacked by corrosion as a function of time by determining the heat transfer in the foil. This is realised by applying a heat pulse generated with optical means and by measuring the diffusion of this pulse applying pyr...","sourceUpdateDate":"2017-02-14 17:46:52","contentUpdateDate":"2004-07-29 00:00:00","archivedDate":"2024-06-20 00:00:00","relations":{"associations":[{"availableLanguages":"de,en,es,fr,it","rcn":"81741","title":"Early fireside corrosion detection","archivedDate":"2024-06-10 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"ener","title":"Energy","displayCode":"\/Energy","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"brief","title":"Result in Brief","description":"Article: Classic and enhanced","displayCode":"\/Result in Brief","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"relatedArticle"}},{"availableLanguages":"en","rcn":"3128026","legalName":"Kema Nederland BV","address":{"street":"Utrechtseweg 310","city":"Arnhem","postalCode":"6812 AR","country":"NL","url":"http:\/\/www.kema.com\/nl\/"},"relations":{"regions":[{"name":"Netherlands","rcn":"391547432","nutsCode":"NL","euCode":"NL","isoCode":"NL","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"eTip","type":"relatedOrganization"}}],"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"en","code":"id13","title":"Experimental development stage (laboratory prototype)","displayCode":"\/Experimental development stage (laboratory prototype)","attributes":{"classification":"resultDevelopmentStage","type":"relatedResultDevelopmentStage"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"eTip","title":"e-TIP","description":"FP5 reporting system (CORDIS application)","displayCode":"\/e-TIP","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"result","attributes":{"source":"eTip","type":"relatedResult"}},{"availableLanguages":"en","rcn":"33045","id":"ENK5-CT-1999-00002_33045_DELIV","title":"Corrosion rate data for boiler superheater and reheater materials","teaser":"Corrosion rates have been measured for four austenitic steels of advanced characteristics and different Cr content (from 12,5 to 22%) operated at full scale and actual plant conditions in the 40MWth experimental boiler of Ansaldo Caldaie\u0092s test facility in Gioia del Colle. The...","sourceUpdateDate":"2017-02-14 17:46:51","contentUpdateDate":"2004-07-29 00:00:00","archivedDate":"2024-06-20 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"en","code":"id15","title":"Results of demonstration trials available","displayCode":"\/Results of demonstration trials available","attributes":{"classification":"resultDevelopmentStage","type":"relatedResultDevelopmentStage"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"eTip","title":"e-TIP","description":"FP5 reporting system (CORDIS application)","displayCode":"\/e-TIP","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"3128023","legalName":"Ansaldo Caldaie S.p.A","address":{"street":"Largo Buffoni, 3","city":"Gallarate","postalCode":"21013","country":"IT","url":"http:\/\/www.ansaldoboiler.it"},"relations":{"regions":[{"name":"Italy","rcn":"309758504","nutsCode":"IT","euCode":"IT","isoCode":"IT","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"eTip","type":"relatedOrganization"}}]},"contenttype":"result","attributes":{"source":"eTip","type":"relatedResult"}},{"availableLanguages":"en","rcn":"33050","id":"ENK5-CT-1999-00002_33050_DELIV","title":"Novel positioning of superheater and new materials to reduce corrosion","teaser":"A corrosion probe positioned in the cyclone loop seal and heated by sand instead of flue gases showed lower metal loss values from erosion or corrosion than a probe in the convective pass (usual position of superheater). Some austenitic stainless steels containing 15-18% chrom...","sourceUpdateDate":"2017-02-14 17:46:53","contentUpdateDate":"2004-07-29 00:00:00","archivedDate":"2024-06-20 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"en","code":"id17","title":"Scientific and\/or technical knowledge (basic research)","attributes":{"classification":"resultDevelopmentStage","type":"relatedResultDevelopmentStage"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"eTip","title":"e-TIP","description":"FP5 reporting system (CORDIS application)","displayCode":"\/e-TIP","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"3128028","legalName":"VATTENFALL AB","address":{"street":"Laemtlandsgatan 99","city":"STOCKHOLM","postalCode":"162 87","country":"SE","url":"http:\/\/www.vattenfall.se"},"relations":{"regions":[{"name":"Sweden","rcn":"473598504","nutsCode":"SE","euCode":"SE","isoCode":"SE","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"eTip","type":"relatedOrganization"}}]},"contenttype":"result","attributes":{"source":"eTip","type":"relatedResult"}},{"availableLanguages":"en","rcn":"33036","id":"ENK5-CT-1999-00002_33036_DELIV","title":"Laboratory scale corrosion experiments","teaser":"The aim of theses corrosion experiments was to verify the behaviour of materials for thermo-electric plants operated at higher temperatures and in low-NOx combustion mode. \n\nThe following activities were carried out:\n- Laboratory experiments aiming at obtaining corrosion data ...","sourceUpdateDate":"2017-02-14 17:46:47","contentUpdateDate":"2004-07-29 00:00:00","archivedDate":"2024-06-20 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"en","code":"id17","title":"Scientific and\/or technical knowledge (basic research)","attributes":{"classification":"resultDevelopmentStage","type":"relatedResultDevelopmentStage"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"eTip","title":"e-TIP","description":"FP5 reporting system (CORDIS application)","displayCode":"\/e-TIP","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"3128014","legalName":"Centro Elettrotecnico Sperimentale Italiano Giacinto Motta SpA (CESI)","address":{"street":"Via Rubattino 54","city":"Milano","postalCode":"20134","country":"IT","url":"http:\/\/www.cesi.it"},"relations":{"regions":[{"name":"Italy","rcn":"309758504","nutsCode":"IT","euCode":"IT","isoCode":"IT","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"eTip","type":"relatedOrganization"}}]},"contenttype":"result","attributes":{"source":"eTip","type":"relatedResult"}}],"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/53\/365\/1111","title":"inorganic compounds","displayCode":"\/natural sciences\/chemical sciences\/inorganic chemistry\/inorganic compounds","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/67\/425\/1165\/1679","title":"coal","displayCode":"\/engineering and technology\/environmental engineering\/energy and fuels\/fossil energy\/coal","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/45\/277\/831","title":"ozone depletion","displayCode":"\/natural sciences\/earth and related environmental sciences\/environmental sciences\/ozone depletion","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/63\/391","title":"coating and films","displayCode":"\/engineering and technology\/materials engineering\/coating and films","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/53\/69669548","title":"catalysis","displayCode":"\/natural sciences\/chemical sciences\/catalysis","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"CSC","title":"Cost-sharing contracts","displayCode":"\/Cost-sharing contracts","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"modelVersion":"132","icaVersion":"20.0.0-48f81e07"}