{"contenttype":"project","language":"en","availableLanguages":"en","rcn":"51196","id":"ERK5-CT-1999-00009","acronym":"SLAGMOD","teaser":"In order to promote a wide spread utilisation of decentralised biomass combustion operational problems like slagging, fouling and corrosion have to be solved or reduced. Based on existing and measured steam data, an on-line dynamic model of the \u003Cwater\/steam cycle will be devel...","objective":"In order to promote a wide spread utilisation of decentralised biomass combustion operational problems like slagging, fouling and corrosion have to be solved or reduced. Based on existing and measured steam data, an on-line dynamic model of the \u003Cwater\/steam cycle will be developed and tested for different boilers in large scale. The model provides operators a tool to recognise and to reduce the slagging and fouling during operation by counter measures in order to increase the economy, efficiency and also emissions of the plant. The model will be applied for a pf, fb and agrate boler and validate both by available operational measurement data and by additional on-line and off-line measurement. The verification of the model for different boilers should result in guidelines for a safe and economic plant operation\nA thermodynamic model to monitor the heat transfer of a biomass fired fluidised boiler has been developed and successfully applied. The modular structure of the model makes it a tool for detecting and analysing local slagging and fouling deposits. The model could also be used as a \u0022soft sensor\u0022 to analyse the varying fuel quality. If obtained in parallel, fuel and ash measurements can therefore be correlated to the simulation and give an insight in the deposit mechanism. During the project the necessary sub-models and gross plant models have been developed: - Dynamic boiler model (Fortran based) for the Uppsala boiler (USTUTT) - Dynamic boiler model (ACM) for the Nyk\u00f6ping and the Uppsala boiler (TUD) - Steady state boiler model (Fortran based) for the monitoring of Uppsala and Nyk\u00f6ping (IST) - NTUA sub models (radiation model, conduction model, deposit properties model and heat transfer model) Results: During the winter 2000\/2001 an extensive measurement campaign at two Swedish power plants was carried out to provide the necessary input data for the offline development and validation of the models. During this campaign the combustion temperature in the plants was measured continuously by acoustic pyrometry.\n\nFurthermore fuel and ash samples were taken and analysed in the IVD fuel laboratory as an additional input for the heat exchanger model (NTUA). During summer 2001 a first set-up of a new designed slagging probe was used in a test facility to receive additional information about the deposit. This was done in co-operation of TUD and USTUTT at the IVD. The available data from the winter measurement campaign have been used in the offline models for further tests. During winter 2001\/2002 the steady state model of TUD was successfully tested online at the Uppsala and the Nyk\u00f6ping plant as well as the dynamic model for Nyk\u00f6ping. Included to another measurement campaign AAU provided impactor measurements and fuel \/ ashes analyses. Essentials of a user interface have been set-up by IST. During summer 2002 the slag characterisation at the USTUTT test facility was continued with an improved probe in co-operation with NTUA and TUD. The integration of the WADA model to the monitoring model of IST was not ready at the end of the project term due to delayed testing of the WADA model at the power plants in Sweden. Both programmes have been tested separately and successfully during the project term to fulfil the objectives of the project. They are working on a stand alone basis at the moment.\n","title":"Slagging and fouling prediction by dynamic boiler modelling (slagmod)","totalCost":"1733034","ecMaxContribution":"1171858","startDate":"2000-02-01","endDate":"2003-01-31","validation":{"euroSciVoc":"false"},"contentCreationDate":"2000-04-17 00:00:00","contentUpdateDate":"2025-09-01 22:35:43","lastUpdateDate":"2026-02-18 16:58:21","archivedDate":"2024-05-21 00:00:00","relations":{"associations":[{"availableLanguages":"de,en,es,fr,it","rcn":"81279","id":"81279-promoting-decentralised-biomass-combustion","title":"Promoting decentralised biomass combustion","teaser":"Aimed at exploiting cleaner energy systems fueled by biomass, an EC funded EESD project generated a dynamic on-line model for assessing heat transfer in boilers. The developed software code is expected to significantly aid resolving two major operational problems related with biomass combustion systems, namely slagging and fouling.","contentUpdateDate":"2005-09-18 17:49:44","archivedDate":"2024-06-10 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"ener","title":"Energy","displayCode":"\/Energy","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"brief","title":"Result in Brief","description":"Article: Classic and enhanced","displayCode":"\/Result in Brief","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"language":"en","availableLanguages":"en,any","uri":"\/docs\/results\/images\/2005-09\/30442.jpg","mimetype":"image\/jpeg","size":"0","copyright":"\u00a9 EyeWire Images","contenttype":"webItem","attributes":{"represents":"article","source":"editorial","type":"relatedImage"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"relatedArticle"}},{"availableLanguages":"en","rcn":"358154","legalName":"UNIVERSITAET STUTTGART","address":{"street":"Pfaffenwaldring 23","city":"STUTTGART","postalCode":"70569","country":"DE"},"relations":{"regions":[{"name":"Germany","rcn":"221940264","nutsCode":"DE","euCode":"DE","isoCode":"DE","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"coordinator","order":"1"}},{"availableLanguages":"en","rcn":"358735","legalName":"VATTENFALL AB","address":{"street":"Laemtlandsgatan 99","city":"STOCKHOLM","postalCode":"162 87","country":"SE","url":"http:\/\/www.vattenfall.se"},"relations":{"regions":[{"name":"Sweden","rcn":"473598504","nutsCode":"SE","euCode":"SE","isoCode":"SE","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"participant","order":"6"}},{"availableLanguages":"en","rcn":"421536","legalName":"INSTITUTO SUPERIOR TECNICO","address":{"street":"Avenida Rovisco Pais","city":"LISBOA","postalCode":"1096","country":"PT"},"relations":{"regions":[{"name":"Portugal","rcn":"427199016","nutsCode":"PT","euCode":"PT","isoCode":"PT","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"participant","order":"4"}},{"availableLanguages":"en","rcn":"475231","legalName":"AABO AKADEMI UNIVERSITY","address":{"street":"14-18B,Lemmink\u00e4inengatan 14-18 B","city":"TURKU \/ ABO","postalCode":"20500","country":"FI"},"relations":{"regions":[{"name":"Finland","rcn":"256543272","nutsCode":"FI","euCode":"FI","isoCode":"FI","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"participant","order":"2"}},{"availableLanguages":"en","rcn":"753048","legalName":"NATIONAL TECHNICAL UNIVERSITY OF ATHENS","address":{"street":"HEROON POLYTECHNIOU ST. 9","city":"ATHENS","postalCode":"10682","country":"EL"},"relations":{"regions":[{"name":"Greece","rcn":"240552488","nutsCode":"EL","euCode":"EL","isoCode":"EL","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"participant","order":"5"}},{"availableLanguages":"en","rcn":"757912","legalName":"DELFT UNIVERSITY OF TECHNOLOGY","address":{"street":"Mekelweg 2","city":"DELFT","postalCode":"2629 CD","country":"NL"},"relations":{"regions":[{"name":"Netherlands","rcn":"391547432","nutsCode":"NL","euCode":"NL","isoCode":"NL","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"participant","order":"3"}},{"availableLanguages":"de,en,es,fr,it","rcn":"643","id":"FP5-EESD","code":"FP5-EESD","frameworkProgramme":"FP5","pga":"FP5-EESD","title":"Programme for research, technological development and demonstration on \u0022Energy, environment and sustainable development, 1998-2002\u0022","shortTitle":"Energy, environment and sustainable development","parent":{"rcn":"624","code":"FP5"},"archivedDate":"2023-03-27 11:33:43","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"legalbasis","title":"Legal Basis","description":"Programme: Legal basis for research funding","displayCode":"\/Legal Basis","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedLegalBasis"}},{"availableLanguages":"en","rcn":"6110","id":"FP5-EESD_1.1.4.-5.","code":"1.1.4.-5.","frameworkProgramme":"FP5","title":"Key action Cleaner Energy Systems, including Renewable Energies","parent":{"rcn":"643\/624","code":"FP5-EESD\/FP5"},"archivedDate":"2023-03-27 11:33:43","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"topic","title":"Topic","description":"Programme: Part of the Commission work programme implementing legal basis","displayCode":"\/Topic","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedTopic"}},{"availableLanguages":"en","rcn":"30441","id":"ERK5-CT-1999-00009_30441_DELIV","title":"On-line model for assessment of heat transfer using standard software","teaser":"This result consists of the methodology to use power plant data to produce comprehensive information on the boiler. Boiler instrumentation information is usually targeted on the water\/steam circuit to control the steam properties to the turbine. The measurements on the flue ga...","sourceUpdateDate":"2017-02-14 17:22:05","contentUpdateDate":"2003-09-08 00:00:00","archivedDate":"2024-06-20 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"en","code":"id27","title":"Software code","displayCode":"\/Software code","attributes":{"classification":"resultDevelopmentStage","type":"relatedResultDevelopmentStage"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"eTip","title":"e-TIP","description":"FP5 reporting system (CORDIS application)","displayCode":"\/e-TIP","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"3127623","legalName":"INSTITUTO SUPERIOR TECNICO","shortName":"ist","address":{"url":"http:\/\/www.ist.utl.pt"},"relations":{"regions":[{"name":"Portugal","rcn":"427199016","nutsCode":"PT","euCode":"PT","isoCode":"PT","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"eTip","type":"relatedOrganization"}}]},"contenttype":"result","attributes":{"source":"eTip","type":"relatedResult"}},{"availableLanguages":"en","rcn":"30442","id":"ERK5-CT-1999-00009_30442_DELIV","title":"Dynamic on-line model for assessment of heat transfer - Fortran Code","teaser":"The purpose of the project was, to predict slagging and fouling behaviour in the boiler in order to minimise of the soot blowing effort. \n\nThis leads to:\n- Optimisation of the boiler efficiency,\n- Better knowledge of the fuel behaviour,\n- Increase of boiler availability,\n- Eas...","sourceUpdateDate":"2017-02-14 17:22:05","contentUpdateDate":"2003-09-08 00:00:00","archivedDate":"2024-06-20 00:00:00","relations":{"associations":[{"availableLanguages":"de,en,es,fr,it","rcn":"81279","title":"Promoting decentralised biomass combustion","archivedDate":"2024-06-10 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"ener","title":"Energy","displayCode":"\/Energy","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"brief","title":"Result in Brief","description":"Article: Classic and enhanced","displayCode":"\/Result in Brief","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"relatedArticle"}},{"availableLanguages":"en","rcn":"3127626","legalName":"IVD - University of Stuttgart","address":{"street":"Pfaffenwaldring 23","city":"Stuttgart","postalCode":"70569","country":"DE"},"relations":{"regions":[{"name":"Germany","rcn":"221940264","nutsCode":"DE","euCode":"DE","isoCode":"DE","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"eTip","type":"relatedOrganization"}}],"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"en","code":"id27","title":"Software code","displayCode":"\/Software code","attributes":{"classification":"resultDevelopmentStage","type":"relatedResultDevelopmentStage"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"eTip","title":"e-TIP","description":"FP5 reporting system (CORDIS application)","displayCode":"\/e-TIP","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"result","attributes":{"source":"eTip","type":"relatedResult"}},{"availableLanguages":"en","rcn":"30443","id":"ERK5-CT-1999-00009_30443_DELIV","title":"Measurement data of plants and of advanced in furnace measurement techniques","teaser":"Vattenfalls work has been detailed data sampling and advanced measurements of slagging and fouling in large CHP-plants. In addition to this CFD modelling for slagmodel evaluation.\n\nLogging systems for collection of operational data has been set up at two plants in the project....","sourceUpdateDate":"2017-02-14 17:22:06","contentUpdateDate":"2003-09-08 00:00:00","archivedDate":"2024-06-20 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"en","code":"id14","title":"Prototype\/demonstrator available for testing","attributes":{"classification":"resultDevelopmentStage","type":"relatedResultDevelopmentStage"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"eTip","title":"e-TIP","description":"FP5 reporting system (CORDIS application)","displayCode":"\/e-TIP","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"3127629","legalName":"Vattenfall Utveckling AB","address":{"street":"\u00c4lvkarleby","city":"\u00c4lvkarleby","postalCode":"814 26","country":"SE"},"relations":{"regions":[{"name":"Sweden","rcn":"473598504","nutsCode":"SE","euCode":"SE","isoCode":"SE","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"eTip","type":"relatedOrganization"}}]},"contenttype":"result","attributes":{"source":"eTip","type":"relatedResult"}},{"availableLanguages":"en","rcn":"30440","id":"ERK5-CT-1999-00009_30440_DELIV","title":"Description of the heat transfer in the furnace","teaser":"NTUA provided simplified models for the heat transfer degradation evaluation due to the ash deposition on the heat exchange surfaces in boilers. Therefore, the heat transfer properties of the ash deposit layer and the heat transfer mechanisms were investigated and simulated in...","sourceUpdateDate":"2017-02-14 17:22:04","contentUpdateDate":"2003-09-08 00:00:00","archivedDate":"2024-06-20 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"en","code":"id17","title":"Scientific and\/or technical knowledge (basic research)","attributes":{"classification":"resultDevelopmentStage","type":"relatedResultDevelopmentStage"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"eTip","title":"e-TIP","description":"FP5 reporting system (CORDIS application)","displayCode":"\/e-TIP","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"3127618","legalName":"National Technical University of Athens","address":{"street":"HEROON POLYTECHNIOU ST. 9","city":"Athens","postalCode":"15780","country":"EL","url":"http:\/\/www.ntua.gr\/en_index.htm"},"relations":{"regions":[{"name":"Greece","rcn":"240552488","nutsCode":"EL","euCode":"EL","isoCode":"EL","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"eTip","type":"relatedOrganization"}}]},"contenttype":"result","attributes":{"source":"eTip","type":"relatedResult"}},{"language":"en","availableLanguages":"en","defaultLanguage":"en","id":"019948ef9561c55c6078b9ae8cf8d69c","archivedDate":"2021-11-16 00:00:00","physUrl":"http:\/\/www.eu-projects.de\/slagmod","status":"invalid","contenttype":"webLink","attributes":{"represents":"project","source":"corda","type":"relatedWebsite","order":"1"}}],"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/67\/425\/83028390","title":"biomass energy","displayCode":"\/engineering and technology\/environmental engineering\/energy and fuels\/biomass energy","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/43\/265","title":"thermodynamics","displayCode":"\/natural sciences\/physical sciences\/thermodynamics","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/73\/453\/58525161","title":"sensors","displayCode":"\/engineering and technology\/electrical engineering, electronic engineering, information engineering\/electronic engineering\/sensors","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"CSC","title":"Cost-sharing contracts","displayCode":"\/Cost-sharing contracts","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"modelVersion":"132","icaVersion":"20.0.0-48f81e07"}