{"contenttype":"project","language":"en","availableLanguages":"en","rcn":"51939","id":"ERK6-CT-1999-00016","acronym":"TESSAS","teaser":"When energy supply and demand is not balanced, storage is necessary. The duration of storage is a parameter of prime importance for energy stores. Short-term thermal energy storage (a few hours to several days) is a common technique but only long-term storage will save energy....","objective":"When energy supply and demand is not balanced, storage is necessary. The duration of storage is a parameter of prime importance for energy stores. Short-term thermal energy storage (a few hours to several days) is a common technique but only long-term storage will save energy. Different mediums can be used such as soil and water bearing layers (Underground Thermal Energy Storage-UTES). Goal of the project is the demonstration on a real scale (600 mwh of store) of thermal energy storage in the underground at a temperature between 40\u00b0C and maximum 85\u00b0C with VHEs (Vertical Heat Exchangers) placed into soil, composed of water-saturated sand layers. The project store will be exploited under realistic conditions (stand -alone situation).\n\n","title":"High temperature thermal energy storage in saturated sans layers with vertical heat exchangers (\u0027TESSAS\u0027)","totalCost":"803093","ecMaxContribution":"390131","startDate":"2000-04-01","endDate":"2004-03-31","contentCreationDate":"2000-05-15 00:00:00","contentUpdateDate":"2005-07-28 00:00:00","lastUpdateDate":"2024-05-23 07:10:46","archivedDate":"2024-05-23 00:00:00","relations":{"associations":[{"availableLanguages":"de,en,es,fr,it","rcn":"82406","id":"82406-underground-thermal-energy-storage","title":"Underground thermal energy storage","teaser":"The ability to store energy in an economical way can be achieved through the use of underground energy storage systems, which provide efficient, clean and discrete storage units. The alternatives, involve the use of power plants, which not only require large areas of land, but are also a source of pollution.","contentUpdateDate":"2006-02-13 17:43:05","archivedDate":"2024-06-10 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"ener","title":"Energy","displayCode":"\/Energy","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"brief","title":"Result in Brief","description":"Article: Classic and enhanced","displayCode":"\/Result in Brief","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"language":"en","availableLanguages":"en,any","uri":"\/docs\/results\/images\/2006-02\/36622.jpg","mimetype":"image\/jpeg","size":"0","copyright":"\u00a9 PhotoDisc","contenttype":"webItem","attributes":{"represents":"article","source":"editorial","type":"relatedImage"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"relatedArticle"}},{"availableLanguages":"en","rcn":"348309","legalName":"IF TECHNOLOGY BV","address":{"street":"1,Frombergstraat 1","city":"ARNHEM","postalCode":"6814 EA","country":"NL"},"relations":{"regions":[{"name":"Netherlands","rcn":"391547432","nutsCode":"NL","euCode":"NL","isoCode":"NL","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"participant","order":"3"}},{"availableLanguages":"en","rcn":"614597","legalName":"BAVARIAN CENTER FOR APPLIED ENERGY RESEACH","address":{"street":"11,Walther-Meissner-Strasse 6","city":"GARCHING","postalCode":"85748","country":"DE"},"relations":{"regions":[{"name":"Germany","rcn":"221940264","nutsCode":"DE","euCode":"DE","isoCode":"DE","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"participant","order":"2"}},{"availableLanguages":"en","rcn":"1148132","legalName":"VITO - VLAAMSE INSTELLING VOOR TECHNOLOGISCH ONDERZOEK NV","address":{"street":"Boeretang 200","city":"MOL","postalCode":"2400","country":"BE"},"relations":{"regions":[{"name":"Belgium","rcn":"188385832","nutsCode":"BE","euCode":"BE","isoCode":"BE","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"coordinator","order":"1"}},{"availableLanguages":"en","rcn":"1148134","legalName":"SMET-G.W.T. SA","address":{"street":"Oude Markt 1","city":"DESSEL","postalCode":"2480","country":"BE"},"relations":{"regions":[{"name":"Belgium","rcn":"188385832","nutsCode":"BE","euCode":"BE","isoCode":"BE","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"participant","order":"4"}},{"availableLanguages":"de,en,es,fr,it","rcn":"643","id":"FP5-EESD","code":"FP5-EESD","frameworkProgramme":"FP5","pga":"FP5-EESD","title":"Programme for research, technological development and demonstration on \u0022Energy, environment and sustainable development, 1998-2002\u0022","shortTitle":"Energy, environment and sustainable development","parent":{"rcn":"624","code":"FP5"},"archivedDate":"2023-03-27 11:33:43","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"legalbasis","title":"Legal Basis","description":"Programme: Legal basis for research funding","displayCode":"\/Legal Basis","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedLegalBasis"}},{"availableLanguages":"en","rcn":"6129","id":"FP5-EESD_1.1.4.-6.","code":"1.1.4.-6.","frameworkProgramme":"FP5","title":"Key action Economic and Efficient Energy for a Competitive Europe","parent":{"rcn":"643\/624","code":"FP5-EESD\/FP5"},"archivedDate":"2023-03-27 11:33:43","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"topic","title":"Topic","description":"Programme: Part of the Commission work programme implementing legal basis","displayCode":"\/Topic","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedTopic"}},{"availableLanguages":"en","rcn":"36622","id":"ERK6-CT-1999-00016_36622_DELIV","title":"Determination of the thermal characteristics of a saturated sand layer","teaser":"The thermal characteristics (borehole resistance, thermal conductivity) of an underground type are strongly influenced by local circumstances such as homogeneity, sand\/silt\/clay content, water saturation, and groundwater level. Within this project the characteristics of a homo...","sourceUpdateDate":"2017-02-15 09:36:29","contentUpdateDate":"2005-09-14 00:00:00","archivedDate":"2024-06-20 00:00:00","relations":{"associations":[{"availableLanguages":"de,en,es,fr,it","rcn":"82406","title":"Underground thermal energy storage","archivedDate":"2024-06-10 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"ener","title":"Energy","displayCode":"\/Energy","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"brief","title":"Result in Brief","description":"Article: Classic and enhanced","displayCode":"\/Result in Brief","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"relatedArticle"}},{"availableLanguages":"en","rcn":"3129079","legalName":"VITO","address":{"street":"Boeretang 200","city":"Mol","postalCode":"2400","country":"BE","url":"http:\/\/www.vito.be"},"relations":{"regions":[{"name":"Belgium","rcn":"188385832","nutsCode":"BE","euCode":"BE","isoCode":"BE","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"eTip","type":"relatedOrganization"}}],"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"en","code":"id17","title":"Scientific and\/or technical knowledge (basic research)","attributes":{"classification":"resultDevelopmentStage","type":"relatedResultDevelopmentStage"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"eTip","title":"e-TIP","description":"FP5 reporting system (CORDIS application)","displayCode":"\/e-TIP","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"result","attributes":{"source":"eTip","type":"relatedResult"}},{"availableLanguages":"en","rcn":"36619","id":"ERK6-CT-1999-00016_36619_DELIV","title":"Analysis of the heat transfer and flow in saturated sand","teaser":"The TESSAS installation is, as a demonstration plant, equipped with a unique underground temperature monitoring system. In total, 66 temperature sensors were placed at various places on different depths inside, below and outside the energy storage field. Due to the continuous ...","sourceUpdateDate":"2017-02-15 09:36:27","contentUpdateDate":"2005-09-14 00:00:00","archivedDate":"2024-06-20 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"en","code":"id15","title":"Results of demonstration trials available","displayCode":"\/Results of demonstration trials available","attributes":{"classification":"resultDevelopmentStage","type":"relatedResultDevelopmentStage"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"eTip","title":"e-TIP","description":"FP5 reporting system (CORDIS application)","displayCode":"\/e-TIP","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"3129076","legalName":"VITO","address":{"street":"Boeretang 200","city":"Mol","postalCode":"2400","country":"BE","url":"http:\/\/www.vito.be"},"relations":{"regions":[{"name":"Belgium","rcn":"188385832","nutsCode":"BE","euCode":"BE","isoCode":"BE","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"eTip","type":"relatedOrganization"}}]},"contenttype":"result","attributes":{"source":"eTip","type":"relatedResult"}},{"availableLanguages":"en","rcn":"36620","id":"ERK6-CT-1999-00016_36620_DELIV","title":"Integration of a high temperature storage field in an existing (building or process) heating system","teaser":"The integration of renewable \/ high efficiency energy systems in existing installations led to numerous problems in the past. Those installations were designed according to traditional rules and uses. The change of heat provider can result in bad performance. The typical probl...","sourceUpdateDate":"2017-02-15 09:36:28","contentUpdateDate":"2005-09-14 00:00:00","archivedDate":"2024-06-20 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"en","code":"id17","title":"Scientific and\/or technical knowledge (basic research)","attributes":{"classification":"resultDevelopmentStage","type":"relatedResultDevelopmentStage"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"eTip","title":"e-TIP","description":"FP5 reporting system (CORDIS application)","displayCode":"\/e-TIP","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"3129077","legalName":"VITO","address":{"street":"Boeretang 200","city":"Mol","postalCode":"2400","country":"BE","url":"http:\/\/www.vito.be"},"relations":{"regions":[{"name":"Belgium","rcn":"188385832","nutsCode":"BE","euCode":"BE","isoCode":"BE","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"eTip","type":"relatedOrganization"}}]},"contenttype":"result","attributes":{"source":"eTip","type":"relatedResult"}},{"availableLanguages":"en","rcn":"36621","id":"ERK6-CT-1999-00016_36621_DELIV","title":"Development of a system for storing large quantities of high temperature heat underground in a saturated sand environment","teaser":"Availability and use of thermal energy doesn\u0027t always match with each other. This leads to the destruction of large amounts of energy, day in day out. The development of a huge underground energy storage system provides a solution for storing the heat on a long-term base (seve...","sourceUpdateDate":"2017-02-15 09:36:28","contentUpdateDate":"2005-09-14 00:00:00","archivedDate":"2024-06-20 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"en","code":"id15","title":"Results of demonstration trials available","displayCode":"\/Results of demonstration trials available","attributes":{"classification":"resultDevelopmentStage","type":"relatedResultDevelopmentStage"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"eTip","title":"e-TIP","description":"FP5 reporting system (CORDIS application)","displayCode":"\/e-TIP","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"3129078","legalName":"VITO","address":{"street":"Boeretang 200","city":"Mol","postalCode":"2400","country":"BE","url":"http:\/\/www.vito.be"},"relations":{"regions":[{"name":"Belgium","rcn":"188385832","nutsCode":"BE","euCode":"BE","isoCode":"BE","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"eTip","type":"relatedOrganization"}}]},"contenttype":"result","attributes":{"source":"eTip","type":"relatedResult"}},{"language":"en","availableLanguages":"en","uri":"\/docs\/projects\/files\/ERK6\/ERK6-CT-1999-00016\/82766681-6.pdf","title":"High Temperature Thermal Energy Storage in Saturated Sand Layers with Vertical Heat Exchangers - TESSAS, Final Report","mimetype":"application\/pdf","size":"2321580","description":"A continuous heat flow from the centre of the earth to our living environment, represents 2,5 times more energy than total mankind consumption at the moment. Enough energy is available inside the earth mass, in order to cover total human energy consumption for the rest of the life span of our planet. Regrettably, the available temperature level of this giant heat release, is too low for use in typical human heat demanding processes to exploit for the production of materials, heating houses, etc. This illustrates how availability and use of thermal energy doesnt (always) match with each other. Every year, huge energy amounts are lost just by this typical mismatch. When thermal energy supply and demand is not balanced, storage is necessary. For long-term storage of a high quantity of thermal energy (MWhs - GWhs), ATES (Aquifer Thermal Energy Storage) or BTES (Borehole Thermal Energy Storage) will be the most favourable technique. An ATES system uses groundwater as a heat transfer medium to bring heat or cold into the underground. A BTES system uses vertical heat exchangers in order to heat up or cool down the sediments. \nThe general objective of TESSAS (High Temperature Thermal Energy Storage in Saturated Sand Layers with Vertical Heat Exchangers) was to perform research on an underground thermal energy storage system, on a real scale. The system will be constructed in a water-saturated sand layer, and equipped with vertical heat exchangers (U-pipes). The store will be charged during summertime, at a temperature of (approximately) 90\u00b0C, by means of a district heating system (waste heat from a coal fired power plant). During winter, the stored heat will be recovered and used for heating a building of 3,700 m(2). Storage of heat at high temperatures has the advantage that heat can be used directly, without heat pumps.","contenttype":"webItem","attributes":{"source":"undefined","type":"relatedPrint"}}],"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"en","code":"CSC","title":"Cost-sharing contracts","displayCode":"\/Cost-sharing contracts","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"modelVersion":"132","icaVersion":"20.0.0-48f81e07"}