{"contenttype":"project","language":"en","availableLanguages":"en","rcn":"54455","id":"FIKS-CT-2000-00073","acronym":"RMPS","teaser":"The functions of the passive B systems are based on thermal-hydraulic (T-H) principles, which are not currently considered to be subject to any kind of failure. But due to the environment and to the physical phenomena that may deviate from expectation, the passive system may...","objective":"The functions of the passive B systems are based on thermal-hydraulic (T-H) principles, which are not currently considered to be subject to any kind of failure. But due to the environment and to the physical phenomena that may deviate from expectation, the passive system may fail to meet its required passive function. The quantification of the T-H unreliability is often still a difficult process due to the numerous uncertainties.\n\nThe methodology that we propose to develop will bring answers to the following problems:\n- Identification and quantification of the sources of uncertainties and determination of the important vanables,\n- Propagation of the uncertainties through a T-H model and reliability assessment of the T-H passive system,\n- Introduction of passive system unreliability in the accident sequence analysis.\n\n","title":"Reliability methods for passive safety functions","totalCost":"944581","ecMaxContribution":"550000","startDate":"2001-02-01","endDate":"2004-01-31","contentCreationDate":"2001-03-16 00:00:00","contentUpdateDate":"2003-04-01 00:00:01","lastUpdateDate":"2024-05-23 07:12:14","archivedDate":"2024-05-23 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"en","code":"CSC","title":"Cost-sharing contracts","displayCode":"\/Cost-sharing contracts","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"420477","legalName":"COMMISSION OF THE EUROPEAN COMMUNITIES","address":{"street":"Westerduinweg 3","city":"PETTEN","postalCode":"1755 ZG","country":"NL"},"relations":{"regions":[{"name":"Netherlands","rcn":"391547432","nutsCode":"NL","euCode":"NL","isoCode":"NL","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"participant","order":"2"}},{"availableLanguages":"en","rcn":"424376","legalName":"CONSORZIO INTERUNIVERSITARIO PER LA RICERCA TECNOLOGICA NUCLEARE","address":{"street":"via Flavia 104","city":"ROMA","country":"IT","url":"http:\/\/www.cirten.it"},"relations":{"regions":[{"name":"Italy","rcn":"309758504","nutsCode":"IT","euCode":"IT","isoCode":"IT","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"participant","order":"3"}},{"availableLanguages":"en","rcn":"753873","legalName":"ITALIAN AGENCY FOR NEW TECHNOLOGY, ENERGY AND THE ENVIRONMENT","address":{"street":"Via Martiri di Monte Sole 4","city":"BOLOGNA","postalCode":"40129","country":"IT"},"relations":{"regions":[{"name":"Italy","rcn":"309758504","nutsCode":"IT","euCode":"IT","isoCode":"IT","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"participant","order":"5"}},{"availableLanguages":"en","rcn":"753886","legalName":"GESELLSCHAFT FUER ANLAGEN- UND REAKTORSICHERHEIT (GRS) MBH","address":{"street":"Forschungsgelaende","city":"GARCHING","postalCode":"85739","country":"DE"},"relations":{"regions":[{"name":"Germany","rcn":"221940264","nutsCode":"DE","euCode":"DE","isoCode":"DE","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"participant","order":"4"}},{"availableLanguages":"en","rcn":"800714","legalName":"COMMISSARIAT A L\u0027ENERGIE ATOMIQUE","address":{"street":"CEA Cadarache, Bat. 238","city":"ST.PAUL LES DURANCE","postalCode":"13108","country":"FR"},"relations":{"regions":[{"name":"France","rcn":"258902568","nutsCode":"FR","euCode":"FR","isoCode":"FR","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"coordinator","order":"1"}},{"availableLanguages":"en","rcn":"800718","legalName":"TECHNICATOME SA","address":{"street":"Avenue Jean-Ren\u00e9 Guillibert Gautier de la Lauziere","city":"AIX EN PROVENCE","postalCode":"13791","country":"FR"},"relations":{"regions":[{"name":"France","rcn":"258902568","nutsCode":"FR","euCode":"FR","isoCode":"FR","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"participant","order":"7"}},{"availableLanguages":"en","rcn":"1006702","legalName":"TECHNICAL UNIVERSITY OF SOFIA","address":{"street":"8, Kl. Ohridski Blvd. Block 12, Office 12440","city":"SOFIA","postalCode":"1797","country":"BG"},"relations":{"regions":[{"name":"Bulgaria","rcn":"188910120","nutsCode":"BG","euCode":"BG","isoCode":"BG","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"participant","order":"6"}},{"availableLanguages":"de,en,es,fr,it","rcn":"649","id":"FP5-EAECTP-C","code":"FP5-EAECTP C","frameworkProgramme":"FP5","pga":"FP5-EAECTP C","title":"Research and training programme (Euratom) in the field of nuclear energy (1998 to 2002)","shortTitle":"Euratom thematic programme - \u0022Nuclear Energy\u0022","parent":{"rcn":"624","code":"FP5"},"archivedDate":"2023-03-27 11:33:43","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"legalbasis","title":"Legal Basis","description":"Programme: Legal basis for research funding","displayCode":"\/Legal Basis","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedLegalBasis"}},{"availableLanguages":"en","rcn":"6300","id":"FP5-EAECTP-C_2.1.2.-1.3.1","code":"2.1.2.-1.3.1","frameworkProgramme":"FP5","title":"Evolutionary safety concepts","parent":{"rcn":"6299\/6222\/649\/624","code":"2.1.2.-1.3.\/2.1.2.-1.\/FP5-EAECTP C\/FP5"},"archivedDate":"2023-03-27 11:33:43","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"topic","title":"Topic","description":"Programme: Part of the Commission work programme implementing legal basis","displayCode":"\/Topic","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedTopic"}},{"availableLanguages":"en","rcn":"34099","id":"FIKS-CT-2000-00073_DELIV","title":"Reliability methods for passive safety functions","teaser":"The objective of the RMPS project was to propose a specific methodology to evaluate the reliability of a thermal-hydraulic (T-H) passive system and to integrate this reliability in accidental sequence of Probabilistic Safety Analysis. \n\nThe project has developed a specific m...","sourceUpdateDate":"2017-02-14 18:06:50","contentUpdateDate":"2004-10-25 00:00:00","archivedDate":"2024-06-20 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"eTip","title":"e-TIP","description":"FP5 reporting system (CORDIS application)","displayCode":"\/e-TIP","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"3128169","legalName":"Commissariat a l\u0027Energie Atomique","address":{"street":"CEA Cadarache, Building 212","city":"Saint-Paul-les-Durance","postalCode":"13108","country":"FR","url":"http:\/\/www.cea.fr\/"},"relations":{"regions":[{"name":"France","rcn":"258902568","nutsCode":"FR","euCode":"FR","isoCode":"FR","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"eTip","type":"relatedOrganization"}}]},"contenttype":"result","attributes":{"source":"eTip","type":"relatedResult"}},{"language":"en","availableLanguages":"en","uri":"\/docs\/projects\/files\/FIKS\/FIKS-CT-2000-00073\/69969321-6.pdf","title":"Synthesis Version of the Final Report","mimetype":"application\/pdf","size":"0","description":"Within the framework of the RMPS project, a methodology has been developed to evaluate the reliability of Passive Systems characterized by a moving fluid and whose working is based on thermal-hydraulic (T-H) principles. The methodology deals with the following problems: - Identification and quantification of the sources of uncertainties and determination of the important variables. - Propagation of the uncertainties through T-H models and assessment of T-H passive system unreliability. - Introduction of passive system unreliability in the accident sequence analysis.","contenttype":"webItem","attributes":{"source":"undefined","type":"relatedPrint"}}]},"modelVersion":"132","icaVersion":"20.0.0-48f81e07"}