{"contenttype":"project","language":"en","availableLanguages":"en","rcn":"54497","id":"IST-1999-13047","acronym":"MICROTRANS","teaser":"This proposal seeks to provide the medical community with an innovative way for reliable monitoring of organs during transplantation. The monitoring, done using a purposely developed microsystem, would provide means for continuous evaluation of organ feasibility both during tr...","objective":"This proposal seeks to provide the medical community with an innovative way for reliable monitoring of organs during transplantation. The monitoring, done using a purposely developed microsystem, would provide means for continuous evaluation of organ feasibility both during transport and postoperative initial evolution. To-date, the need for a perfect temperature and pathogen isolation of the organ during transport has been a major barrier in evaluating the needs and results of a constant monitoring. The recent development of silicon micro-biosensors opens a way in which to attain this objective without resigning to the mentioned organ isolation. Any action taken to increase the number of organs viable and improve their postoperative function shall be welcome by the European Society. \n\nObjectives:\nThe proposed project intends to assist (1) the viability assessment of organs due for transplantation, expanding thus the number of available grafts and their possible destinies, and (2) the monitoring of organ behaviour during the initial postoperative period. The technological goal of this project is to raise awareness in the microsystems field through their use in a biomedical application that also requires a high level expertise on microelectronics design. Development of applications displaying these sort of needs and requiring these kind of solutions will contribute to enhance the European industry competitiveness broadening the market for both the silicon industries and the biomedical industries themselves\n\nWork description:\nThe proposal will result in a new generation of medical devices for patient continuous monitoring. Through the use of available processes and microtechnologies quality of medical information and quality of assistance will be powered-up while reducing patient\u0027s risks and discomfort and hence, enhancing patients\/ quality of life.\n\nIn order to provide the means for the above general objective, the following goals are proposed:\n- To design, characterize and test a bio-sensing system for in-situ monitoring of he organ tissue, both during transport and initial postoperative evolution (tissue impedance, pH, K+ concentration and temperature will act as initial prognosis tools for the organ viability on the present proposal. Other, organ specific, parameters that should outlay a more selective prognosis for each organ will be studied and implemented within this project).\n- To validate the feasibility and reliability of the system for in-situ monitoring of the chosen organ parameters.\n- To investigate the usefulness of standard parameters in the prediction of organ viability.\n- To study and test new and more effective parameters for prediction of organ viability and develop their corresponding micro-sensors.\n- To analyse the real impact of the system\u0027s use.\n\nThe system will be implemented in two different outsets: a system for transport control in an adapted cryogenic chamber, and a system for bedside monitoring of the organ during postoperative evolution.\nThe actual outcome consist on a pre-industrial device able to organ monitoring during transport. This device is constituted by a multisensor core element which should be inserted in the organ. Signals obtained trough the sensoring device are conditioned by appropriated electronics, pre-processed and transmitted by RF operating at a public frequency out of the sterilized bags containing the organ. Measured parameters are received and externally processed through a commercial PALM that is in charge of display the main results and of firing alarms when needed. This device has been extensively proved. The latest experiments will begin at next September and it is expected to use it on humans at the beginning on next year (2004).\n","title":"Microprobe multi-sensor for graft viability monitoring during organ preservation and transplantation","keywords":"Nanotechnology","totalCost":"1926856","ecMaxContribution":"1200000","startDate":"2000-01-01","endDate":"2002-12-31","validation":{"euroSciVoc":"false"},"contentCreationDate":"2001-03-23 00:00:00","contentUpdateDate":"2005-06-13 00:00:00","lastUpdateDate":"2026-02-18 16:58:25","archivedDate":"2024-05-27 00:00:00","relations":{"associations":[{"availableLanguages":"de,en,es,fr,it","rcn":"81502","id":"81502-disposable-sensor-for-organ-transplantation","title":"Disposable sensor for organ transplantation","teaser":"The ever-increasing need for organs for transplantation can only be covered by an increase in the number of the donors. However, the success rate of transplantations of current organ supplies can be improved through organ viability monitoring.","contentUpdateDate":"2005-09-18 17:50:21","archivedDate":"2024-06-10 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"health","title":"Health","displayCode":"\/Health","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"brief","title":"Result in Brief","description":"Article: Classic and enhanced","displayCode":"\/Result in Brief","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"language":"en","availableLanguages":"en,any","uri":"\/docs\/results\/images\/2005-09\/32022.jpg","mimetype":"image\/jpeg","size":"0","copyright":"\u00a9 PhotoDisc","contenttype":"webItem","attributes":{"represents":"article","source":"editorial","type":"relatedImage"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"relatedArticle"}},{"availableLanguages":"en","rcn":"1037999","legalName":"CONSEJO SUPERIOR DE INVESTIGACIONES CIENTIFICAS","address":{"street":"C\/ SERRANO 117","city":"MADRID","postalCode":"28006","country":"ES"},"relations":{"regions":[{"name":"Spain","rcn":"242387496","nutsCode":"ES","euCode":"ES","isoCode":"ES","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"coordinator","order":"1"}},{"availableLanguages":"en","rcn":"1153403","legalName":"SCUOLA SUPERIORE DI STUDI UNIVERSITARI E DI PERFEZIONAMENTO SANT\u0027ANNA","address":{"street":"PIAZZA MARTIRI DELLA LIBERTA, 33","city":"PISA","postalCode":"56127","country":"IT"},"relations":{"regions":[{"name":"Italy","rcn":"309758504","nutsCode":"IT","euCode":"IT","isoCode":"IT","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"participant","order":"5"}},{"availableLanguages":"en","rcn":"1153405","legalName":"UNIVERSITEIT VAN AMSTERDAM - ACADEMISCH ZIEKENHUIS","address":{"street":"MEIBERGDREEF 9","city":"AMSTERDAM","postalCode":"1105 AZ","country":"NL"},"relations":{"regions":[{"name":"Netherlands","rcn":"391547432","nutsCode":"NL","euCode":"NL","isoCode":"NL","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"participant","order":"8"}},{"availableLanguages":"en","rcn":"1153407","legalName":"UNIVERSITA DI PISA","address":{"street":"LUNGARNO PACINOTTI 43\/44","city":"PISA","postalCode":"56100","country":"IT"},"relations":{"regions":[{"name":"Italy","rcn":"309758504","nutsCode":"IT","euCode":"IT","isoCode":"IT","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"participant","order":"6"}},{"availableLanguages":"en","rcn":"1153409","legalName":"KAYSER ITALIA S.R.L.","address":{"street":"PIAZZA 185 R.A. FOLGORE 2\/3","city":"LIVORNO","postalCode":"57128","country":"IT"},"relations":{"regions":[{"name":"Italy","rcn":"309758504","nutsCode":"IT","euCode":"IT","isoCode":"IT","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"participant","order":"3"}},{"availableLanguages":"en","rcn":"1153411","legalName":"S.E. DE CARBUROS METALICOS S.A.","address":{"street":"ARAGON 300","city":"BARCELONA","postalCode":"08080","country":"ES"},"relations":{"regions":[{"name":"Spain","rcn":"242387496","nutsCode":"ES","euCode":"ES","isoCode":"ES","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"participant","order":"4"}},{"availableLanguages":"en","rcn":"1153414","legalName":"UNIVERSITY OF ULSTER","address":{"street":"CROMORE ROAD","city":"COLERAINE","postalCode":"BT52 1SA","country":"UK"},"relations":{"regions":[{"name":"United Kingdom","rcn":"508725800","nutsCode":"UK","euCode":"UK","isoCode":"GB","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"participant","order":"9"}},{"availableLanguages":"en","rcn":"1153416","legalName":"CORPORACIO SANITARIA CLINIC","address":{"street":"VILLARROEL 170","city":"BARCELONA","postalCode":"08036","country":"ES"},"relations":{"regions":[{"name":"Spain","rcn":"242387496","nutsCode":"ES","euCode":"ES","isoCode":"ES","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"participant","order":"2"}},{"availableLanguages":"en","rcn":"1153418","legalName":"UNIVERSITAT AUTONOMA DE BARCELONA","address":{"street":"CAMPUS UNIVERSITARI S\/N","city":"BELLATERRA (CERDANYOLA DEL VALLES)","postalCode":"08290","country":"ES"},"relations":{"regions":[{"name":"Spain","rcn":"242387496","nutsCode":"ES","euCode":"ES","isoCode":"ES","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"corda","type":"participant","order":"7"}},{"availableLanguages":"de,en,es,fr,it","rcn":"641","id":"FP5-IST","code":"FP5-IST","frameworkProgramme":"FP5","pga":"FP5-IST","title":"Programme for research, technological development and demonstration on a \u0022User-friendly information society, 1998-2002\u0022","shortTitle":"User-friendly information society","parent":{"rcn":"624","code":"FP5"},"archivedDate":"2023-03-27 11:33:43","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"legalbasis","title":"Legal Basis","description":"Programme: Legal basis for research funding","displayCode":"\/Legal Basis","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedLegalBasis"}},{"availableLanguages":"en","rcn":"6000","id":"FP5-IST_1.1.2.-4.7.3","code":"1.1.2.-4.7.3","frameworkProgramme":"FP5","title":"Microsystems","parent":{"rcn":"5997\/5973\/641\/624","code":"1.1.2.-4.7.\/1.1.2.-4.\/FP5-IST\/FP5"},"archivedDate":"2023-03-27 11:33:43","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"topic","title":"Topic","description":"Programme: Part of the Commission work programme implementing legal basis","displayCode":"\/Topic","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedTopic"}},{"availableLanguages":"en","rcn":"32023","id":"IST-1999-13047_32023_DELIV","title":"Low cost disposable sensor device for organ viability monitoring ","teaser":"Low cost disposable sensor device for organ viability monitoring.\n\nA minimally invasive microprobe measuring tissular temperature and bio impedance has been designed, fabricated, validated and improved up to its present pre-industrial stage. It uses a Si-based multi-micro sens...","sourceUpdateDate":"2017-02-14 17:44:13","contentUpdateDate":"2004-02-03 00:00:00","archivedDate":"2024-06-20 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"eTip","title":"e-TIP","description":"FP5 reporting system (CORDIS application)","displayCode":"\/e-TIP","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"3132444","legalName":"CNM (CSIC)","address":{"street":"Campus UAB","city":"Bellaterra","postalCode":"08193","country":"ES"},"relations":{"regions":[{"name":"Spain","rcn":"242387496","nutsCode":"ES","euCode":"ES","isoCode":"ES","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"eTip","type":"relatedOrganization"}}]},"contenttype":"result","attributes":{"source":"eTip","type":"relatedResult"}},{"availableLanguages":"en","rcn":"32024","id":"IST-1999-13047_32024_DELIV","title":"PDA-based electronic system clinically usable for graft monitoring","teaser":"A portable instrumentation system capable of monitoring bioimpedance and other parameters was developed. It makes use of the bioimpedance probes evaluated during the project and its digital core and user interface is based on a PDA. Its main target application is to monitor th...","sourceUpdateDate":"2017-02-14 17:44:13","contentUpdateDate":"2004-02-03 00:00:00","archivedDate":"2024-06-20 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"eTip","title":"e-TIP","description":"FP5 reporting system (CORDIS application)","displayCode":"\/e-TIP","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"3132446","legalName":"CNM (CSIC)","address":{"street":"Campus UAB","city":"Bellaterra","postalCode":"08193","country":"ES"},"relations":{"regions":[{"name":"Spain","rcn":"242387496","nutsCode":"ES","euCode":"ES","isoCode":"ES","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"eTip","type":"relatedOrganization"}}]},"contenttype":"result","attributes":{"source":"eTip","type":"relatedResult"}},{"availableLanguages":"en","rcn":"32025","id":"IST-1999-13047_32025_DELIV","title":"A objective method to evaluate graft preservation ","teaser":"It has been suggested that electrical bio-impedance can be a good marker of cell viability. The changes in bio-impedance of ischemic liver tissue, in vivo and ex vivo, at room temperature have been quantified (references). An increase in bio-impedance for all frequencies durin...","sourceUpdateDate":"2017-02-14 17:44:14","contentUpdateDate":"2004-02-03 00:00:00","archivedDate":"2024-06-20 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"en","code":"id15","title":"Results of demonstration trials available","displayCode":"\/Results of demonstration trials available","attributes":{"classification":"resultDevelopmentStage","type":"relatedResultDevelopmentStage"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"eTip","title":"e-TIP","description":"FP5 reporting system (CORDIS application)","displayCode":"\/e-TIP","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"3132450","legalName":"CNM (CSIC)","address":{"street":"Campus UAB","city":"Bellaterra","postalCode":"08193","country":"ES"},"relations":{"regions":[{"name":"Spain","rcn":"242387496","nutsCode":"ES","euCode":"ES","isoCode":"ES","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"eTip","type":"relatedOrganization"}}]},"contenttype":"result","attributes":{"source":"eTip","type":"relatedResult"}},{"availableLanguages":"en","rcn":"32022","id":"IST-1999-13047_32022_DELIV","title":"A electronic instrumentation to measure living tissue conditions","teaser":"Two kind of a measurement system have been developed, the first one to be used in clinical environment and the other one for in-vivo experimentation. Electronics for \u0022on line\u0022 sensor characterization have been also developed.\n\nDeveloped instrumentation allows it to display, to...","sourceUpdateDate":"2017-02-14 17:44:12","contentUpdateDate":"2004-02-03 00:00:00","archivedDate":"2024-06-20 00:00:00","relations":{"associations":[{"availableLanguages":"de,en,es,fr,it","rcn":"81502","title":"Disposable sensor for organ transplantation","archivedDate":"2024-06-10 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"health","title":"Health","displayCode":"\/Health","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"brief","title":"Result in Brief","description":"Article: Classic and enhanced","displayCode":"\/Result in Brief","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"relatedArticle"}},{"availableLanguages":"en","rcn":"3132442","legalName":"CNM (CSIC)","address":{"street":"Campus UAB","city":"Bellaterra","postalCode":"08193","country":"ES"},"relations":{"regions":[{"name":"Spain","rcn":"242387496","nutsCode":"ES","euCode":"ES","isoCode":"ES","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"eTip","type":"relatedOrganization"}}],"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"deliverable","title":"Project deliverable","description":"Result: Project deliverables","displayCode":"\/Project deliverable","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"en","code":"id15","title":"Results of demonstration trials available","displayCode":"\/Results of demonstration trials available","attributes":{"classification":"resultDevelopmentStage","type":"relatedResultDevelopmentStage"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"eTip","title":"e-TIP","description":"FP5 reporting system (CORDIS application)","displayCode":"\/e-TIP","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"result","attributes":{"source":"eTip","type":"relatedResult"}},{"language":"en","availableLanguages":"en","defaultLanguage":"en","id":"60b0eb5e584037c4755f78e8b34a4b72","archivedDate":"2021-11-16 00:00:00","physUrl":"http:\/\/www.cnm.es\/~mtrans\/","status":"invalid","contenttype":"webLink","attributes":{"represents":"project","source":"corda","type":"relatedWebsite","order":"1"}}],"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/71\/447","title":"biosensing","displayCode":"\/engineering and technology\/environmental biotechnology\/biosensing","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/43\/259\/783","title":"microelectronics","displayCode":"\/natural sciences\/physical sciences\/electromagnetism and electronics\/microelectronics","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/53\/365\/71735538","title":"metalloids","displayCode":"\/natural sciences\/chemical sciences\/inorganic chemistry\/metalloids","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/21\/39\/237","title":"transplantation","displayCode":"\/medical and health sciences\/clinical medicine\/transplantation","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/59\/379","title":"microtechnology","displayCode":"\/engineering and technology\/other engineering and technologies\/microtechnology","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"CSC","title":"Cost-sharing contracts","displayCode":"\/Cost-sharing contracts","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"modelVersion":"132","icaVersion":"19.1.0-ea6a1f3f"}