{"contenttype":"project","language":"en","availableLanguages":"en","rcn":"5057","id":"JOU20220","teaser":"If CO2 shall be captured from the flue gases of coal fired power stations for subsequent dumping, a viable technology should be available also for retrofitting existing conventional pulverized coal fired power stations. \nThe objective is to investigate the potential for the us...","objective":"If CO2 shall be captured from the flue gases of coal fired power stations for subsequent dumping, a viable technology should be available also for retrofitting existing conventional pulverized coal fired power stations. \nThe objective is to investigate the potential for the use of recycled flue gases and oxygen injection in a large scale atmospheric coal burner designed to produce combustion products which are more suitable for treatment in carbon dioxide reduction processes. \n\nThe main issues associated with retrofit conversion of an existing coal-fired boiler were identified, including boiler start-up and change-over, retrofit changes to boiler configuration and equipment, and air leakage into the furnace. This last was found to be the most significant practical obstacle to successful oxygen\/flue gas recirculation operation. Ultra low air ingress levels are needed to maintain CO2 concentrations high enough for efficient operation of the flue gas liquefaction process. Existing balanced draught boilers cannot deliver such low ingress levels unless they are modified to pressurised furnace operation, which would cause significant financial and technical repercussions. Overall thermal efficiency was predicted to fall from 37% for a conventional system to 23%, mainly because of the power consumption of the oxygen separation and CO2 liquefaction plants.\nThe combustion of fossil fuels is one of the main sources of global atmospheric pollution. Improvements in air quality have been achieved by using a combination of low NOx burners, catalysts, flue gas \ndesulphurisation and cleaner fuels. Looking forward towards a cleaner, less polluting environment, attention is now concentrated on reducing the emissions of gases which contribute to global warming. \n\nThe combustion of pulverised coal for large scale power generation will continue for the foreseeable future and this project will study the opportunities for reducing pollution from existing atmospheric systems. This project will examine the combustion of pulverised coal in an atmosphere of recycled flue gas with oxygen injection and measurements will be taken of efficiency, pollutants and suitability for installation in a wide variety of burner sizes in existing large scale boilers. Particular attention will be given to ensure that new pollutants, such as those produced by combustion at low temperature, are minimised. \n\nThe investigations will commence on small scale flames, a burner will be specifically developed using a combination of mathematical and physical modelling techniques. The performance of the small flame will be measured in detail and information obtained on the chemical species produced in both the near burner region and those emitted from the furnace outlet. Sufficient data will be gathered to ensure that the additional routines needed in the mathematical code will be validated and be used to scale up the burner to ten megawatts. This large scale burner will be evaluated on the combustion test facilities at Derby. \n","title":"Coal combustion in advanced burners for minimal emissions and carbon dioxide reduction technologies","startDate":"1993-01-01","endDate":"1995-12-31","validation":{"euroSciVoc":"false"},"contentCreationDate":"1993-02-26 00:00:00","contentUpdateDate":"1995-03-23 00:00:02","lastUpdateDate":"2026-02-18 16:58:34","archivedDate":"2024-04-19 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/67\/425\/1165\/1679","title":"coal","displayCode":"\/engineering and technology\/environmental engineering\/energy and fuels\/fossil energy\/coal","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/67\/39381296","title":"air pollution engineering","displayCode":"\/engineering and technology\/environmental engineering\/air pollution engineering","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/45\/277\/829","title":"pollution","displayCode":"\/natural sciences\/earth and related environmental sciences\/environmental sciences\/pollution","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/53\/69669548","title":"catalysis","displayCode":"\/natural sciences\/chemical sciences\/catalysis","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"CSC","title":"Cost-sharing contracts","displayCode":"\/Cost-sharing contracts","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"undefined","title":"Undefined","description":"Legacy content transferred to CORDIS - no documentation","displayCode":"\/Undefined","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"255360","legalName":"NEI International Combustion Ltd","address":{"street":"NEI House","city":"Newcastle upon Tyne","postalCode":"NE3 3SB","country":"UK"},"relations":{"regions":[{"name":"United Kingdom","rcn":"508725800","nutsCode":"UK","euCode":"UK","isoCode":"GB","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"undefined","type":"coordinator","order":"1"}},{"availableLanguages":"en","rcn":"346337","legalName":"EDP - Electricidade de Portugal SA","address":{"street":"2\/2,Rua Cova da Moura","city":"Lisboa","postalCode":"1350","country":"PT"},"relations":{"regions":[{"name":"Portugal","rcn":"427199016","nutsCode":"PT","euCode":"PT","isoCode":"PT","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"undefined","type":"participant","order":"2"}},{"availableLanguages":"en","rcn":"348214","legalName":"IMPERIAL COLLEGE OF SCIENCE, TECHNOLOGY AND MEDICINE","address":{"street":"Exhibition Road","city":"LONDON","postalCode":"SW7 2BX","country":"UK","url":"http:\/\/www.nimblesite.com\/xcittic\/"},"relations":{"regions":[{"name":"United Kingdom","rcn":"508725800","nutsCode":"UK","euCode":"UK","isoCode":"GB","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"undefined","type":"participant","order":"3"}},{"availableLanguages":"en","rcn":"349313","legalName":"INSTITUTO SUPERIOR TECNICO","address":{"street":"1,Avenida Rovisco Pais 1","city":"LISBOA","postalCode":"1049-001","country":"PT"},"relations":{"regions":[{"name":"Portugal","rcn":"427199016","nutsCode":"PT","euCode":"PT","isoCode":"PT","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"undefined","type":"participant","order":"4"}},{"availableLanguages":"en","rcn":"349839","legalName":"Lamda Technical Ltd","address":{"street":"4,Hadjiyianni Mexi Street","city":"Athens","postalCode":"11528","country":"EL"},"relations":{"regions":[{"name":"Greece","rcn":"240552488","nutsCode":"EL","euCode":"EL","isoCode":"EL","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"undefined","type":"participant","order":"5"}},{"availableLanguages":"de,en,fr,it","rcn":"188","id":"FP3-JOULE-2","code":"FP3-JOULE 2","frameworkProgramme":"FP3","pga":"FP3-JOULE 2","title":"Specific research and technological development programme (EEC) in the field of non-nuclear energy, 1990-1994","shortTitle":"Non-nuclear energy","parent":{"rcn":"1005","code":"FP3"},"archivedDate":"2023-03-27 11:33:43","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"legalbasis","title":"Legal Basis","description":"Programme: Legal basis for research funding","displayCode":"\/Legal Basis","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"undefined","type":"relatedLegalBasis"}},{"availableLanguages":"en","rcn":"3634","id":"FP3-JOULE-2_0201","code":"0201","frameworkProgramme":"FP3","title":"Energy production from fossil sources using advanced technologies","parent":{"rcn":"3633\/188\/1005","code":"02\/FP3-JOULE 2\/FP3"},"archivedDate":"2023-03-27 11:33:43","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"topic","title":"Topic","description":"Programme: Part of the Commission work programme implementing legal basis","displayCode":"\/Topic","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"undefined","type":"relatedTopic"}},{"availableLanguages":"en","rcn":"21189","id":"JOU20220_EXPL","title":"Retrofitting coal power stations to minimize carbon dioxide emissions","teaser":"Carbon dioxide emissions could be eliminated from coal power stations if the carbon dioxide were to be collected and liquefied when the fuel is burnt using oxygen enrichment and flue gas recirculation techniques. However, extensive practical and modelling studies carried out i...","contentUpdateDate":"1998-09-16 00:02:53","archivedDate":"2024-06-22 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"exploitable","title":"Exploitable Result","description":"Result: main interesting result, which has been selected and prioritized due to its high potential to be \u0022exploited\u0022","displayCode":"\/Exploitable Result","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"undefined","title":"Undefined","description":"Legacy content transferred to CORDIS - no documentation","displayCode":"\/Undefined","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"3112433","legalName":"International Combustion Ltd.","address":{"street":"Sinfin Lane","city":"Derby","postalCode":"DE24 9GJ","country":"UK"},"relations":{"regions":[{"name":"United Kingdom","rcn":"508725800","nutsCode":"UK","euCode":"UK","isoCode":"GB","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"undefined","type":"relatedOrganization"}}]},"contenttype":"result","attributes":{"source":"undefined","type":"relatedResult"}}]},"modelVersion":"132","icaVersion":"20.0.0-48f81e07"}