PV ELECTRIFICATION FOR PROTECTED NATURAL AREAS IN FRANCE AND OVERSEAS

Objetivo

To continue the electrification of isolated locations in natural parks all over France by pv installations, that respect the environment and the architecture.
(Continuation of projects 167/87, 213/88 and 073/89)
This system work well, with high reliability and without noise or other pollution.
The sites are in National and Regional Parks in France and overseas departments (Ecrins, Guadeloupe, Luberon, Vanoise, Volcans d'Auvergne, Marais Poitevin, Corse). The original project (11.424 Wp of PV arrays in 73 systems) has been adapted to 9440 kWp in 30 systems, but with better monitoring, to provide power for buildings such as information centres, museums and lodges and also 3 water pumps.
Nr. subsystems : 30
Power subsys. : 48 to 1152 Wp
Total power : about 9500 Wp
Backup : none
Nr. of modules : about 200
Module descript. : PHOTOWATT BPX 47500, from 48 Wp, double glass, anodized aluminium frame.
Connection : mainly two in series (24 V), but also 12 and 96 V
Support : different
Max. pwr. trcker : none
Chrg. controler : Solelec, regulation at two levels
Battery : STECCO, VARTA, OLDHAM
Capacity (Ah) : 100 to 800 Ah
Inverter : Victron and 600 W "TRACE"
Inv. in (V) : 24 V dc
Inv. out (V) : 220 V ac
Inv. power (kW) : 0,3 to 1.2 kVA
Load descript. : fluo lights (8 and 13 W) and halogen (10 and 20 W), pumps, refrigerators (DC), freezers (DC).
Monitoring : amperehourmeters TOTAL ENERGIE on 4 installations. Telemetering systems by NAPAC on six installations, one SUNPACK monitor.