43% Electric Efficient Gas Turbine in Winter Operation for Nancy District Heating and National Grid Electricity Supply

Objective

Demonstration of a 43 % electric efficient 1,4 MWe gas turbine for the supply of heat in a district heating system in Nancy (FR) and the supply of electricity to the national grid in the contract period November - March and moreover to ameliorate the present negative environmental effect of energy from coal and fuel oil. Heat production is variable between 1,0 - 2,5 MWth. The innovations are an electric efficiency of 43%, compared to the 20 - 25% for gas turbines of comparable size and compared to the 38,5% of the THERMIE-supported proof of concept test model. NOx emission level is < 10 ppmv. Two-stage combustion, intercooling, heat recuperation, low temperatures and pressures, all so typical for the cycle, allow for the high electric efficiency, a high lifetime and low maintenance costs. The project saves 560 TOE/ a. The payback time is 10 years in project's 5 month operation and 6 - 7 years in future commercial applications.

Call for proposal

Data not available

Funding Scheme

Data not available

Coordinator

SCHELDE HERON B.V.
EU contribution
No data
Address
Tramsingel 15
4814 AB BREDA
Netherlands

See on map

Total cost
No data

Participants (3)