Objective The share of the electric arc furnace in the production of crude steel increases steadily and it is expected to exceed 50% by the year 2010. The exhaust gas of an electric arc furnace contains a considerable amount of energy as heat and chemical energy from incompletely burned components CO and H2. Up to 30% of the total energy input to an EAF can be lost in the off-gas handling system. Therefore, post-combustion of CO and the effective recovery of heat generated during the flat bath period will be an integral part of the operating practice. The final aim of this research is to develop a concept of controlled post-combustion of CO inside the furnace. For this purpose, an integrated measurement system for the temperature and the gas components CO, CO2 and O2 for on-line monitoring the post-combustion process inside EAF will be developed based on the FTIR spectrometry. Programme(s) ECSC-STEEL C - Medium-term guidelines for the ECSC steel RTD programme of research and pilot/demonstration projects, 1996-2002 Topic(s) E - Analytical Techniques for Processes, Products & Environment Call for proposal Data not available Funding Scheme CSC - Cost-sharing contracts Coordinator RHEINISCH-WESTFÄLISCHE TECHNISCHE HOCHSCHULE AACHEN FÜR DAS IEHK EU contribution No data Address Templergraben 55 52062 AACHEN Germany See on map Total cost No data Participants (3) Sort alphabetically Sort by EU Contribution Expand all Collapse all MESSER GRIESHEIM Germany EU contribution No data Address Frankfurt Airport Centre 1, C9 60541 FRANKFURT See on map Total cost No data STAHLWERKE THÜRINGEN Germany EU contribution No data Address 07331 UNTERWELLENBORN See on map Total cost No data THE UNIVERSITY OF READING United Kingdom EU contribution No data Address Palmer Building Whiteknights RG6 6AH READING See on map Total cost No data