Skip to main content
European Commission logo print header
Inhalt archiviert am 2022-11-21

Fire resistance of long span cellular beam made of rolled profiles

Ziel

Cellular beams (CB) offer long uninterrupted clear spans, which are ideal for offices. However, increasingly, questions are being asked about the performance of CB in fire and especially, about the performance of the protection material.

A uniform European design approach is required to overcome the present lack of knowledge. This should include both protected and unprotected beams fabricated from hot rolled sections. The design approach will be developed using standard furnace fire resistance tests, a large full sized test and numerical simulations. It will lead to reduced amounts of fire protection, more economic designs and an increase use of CB.

Thema/Themen

Data not available

Aufforderung zur Vorschlagseinreichung

Data not available

Finanzierungsplan

Data not available

Koordinator

ARCELORMITTAL BELVAL & DIFFERDANGE
EU-Beitrag
Keine Daten
Adresse
RUE DU LUXEMBOURG 66
ESCH-SUR-ALZETTE
Luxemburg

Auf der Karte ansehen

Gesamtkosten
Keine Daten

Beteiligte (6)