Community Research and Development Information Service - CORDIS

Horizon 2020 project information and now also report summaries are available on CORDIS. All H2020 projects can be downloaded from the EU Open Data Portal .

My refinements


Download results of this page


Refine by:

Advanced search

Search projects and results

Results 1 - 10 of 113
Order by: Results/page:
12 3 4 5 6 7 8 9 10 > >| 
World record for H- ion current extracted from uncesiated RF source
Increased Pulse Power at DESY. With a new collar design it was possible to increase the current from 40mA to 54mA. With an extraction opening 6.5 mm in diameter, the achieved current density is 163 mA/cm2. This is a new international record for an uncesiated H- source. It is t...
Programme: FP5-HUMAN POTENTIAL
Record Number: 42577
Last updated on: 2008-07-01
Large aperture SLM
[REPORT SUMMARY] Large aperture SLM
Laser resistance for OA-SLMs Laser damage resistance of OASLM based on both polymer (PVK) and crystalline (BSO) photoconductive materials has been evaluated during the course of this project. They presented for the different types of photoconductors roughly the same damage ...
Programme: FP5-HUMAN POTENTIAL
Record Number: 39523
Last updated on: 2007-02-19
A spectrometer for ion-surface interaction studies
The envisaged objective was to design and construct a particle detector for use with the Hitrap facility, offering a large range of flexibility for different kinds of application. The design focussed on the problem of low particle intensities expected from the Hitrap facility....
Programme: FP5-HUMAN POTENTIAL
Record Number: 40644
Last updated on: 2007-02-06
Protected fluoride multilayer mirror for 180nm
An optimised mirror has been developed based on an evaporated stack of pure fluoride, to provide the high reflectivity, protected with a dense sputtered (IBS) SiO2 layer allowed a stable lasing at 180 nm. The progress could only be achieved at LZH after a thorough optimisation...
Programme: FP5-HUMAN POTENTIAL
Record Number: 40646
Last updated on: 2007-01-26
Numerical simulations for the Riga dynamo
Full numerical solutions have been developed in order to calculate the fluid flow and the related magnetic field distribution of the Riga dynamo experiment. Two-equation eddy-viscosity and full Reynolds-stress models have been used for the turbulence modelling. The coupled sys...
Programme: FP5-HUMAN POTENTIAL
Record Number: 39520
Last updated on: 2006-12-29
Double CPA concept with non linear filtering
Double CPA concept with non linear filtering : The principle of the double CPA concept is to build a first CPA laser system in order to obtain femtoseconde pulses at a millijoule level. Those pulses are filtered thanks to a nonlinear filter in order to obtain pulses of a few h...
Programme: FP5-HUMAN POTENTIAL
Record Number: 42574
Last updated on: 2006-11-28
XeF direct femtosecond amplification
A compact photolytical XeF(C-A) amplifier for direct amplification of high-power visible femtosecond laser pulses has been developed. This device uses a low density gaseous amplifier medium, attractive for ultrafast laser amplification due to its low non-linear index of refra...
Programme: FP5-HUMAN POTENTIAL
Record Number: 42568
Last updated on: 2006-11-28
External cavity ring down technique as plasma diagnostic
DCU has primarily carried out work on plasma modeling and plasma diagnostics in an effort to understand H- formation. - A 2D Particle-in-Cell code with Monte-Carlo-Collisions and the Global Model Solver has been developed, with some limitations, for plasma modelling purposes. ...
Programme: FP5-HUMAN POTENTIAL
Record Number: 42583
Last updated on: 2006-11-28
New ISOL beams at ISOLDE
[REPORT SUMMARY] New ISOL beams at ISOLDE
New or improved ISOL beams of the following elements have been produced at ISOLDE: 7Be, 10Be, 19-22O, 24-30Ne, 22,23Mg, 30-34Mg, 28-34Al, 41-50Ar, 69-81Zn, 61-86Ga, 70Br, 96-99Kr, 124-133Cd, 130-135In, 130-137Sn, 112-115Xe, 145-147Xe, 158-185Hf, 179-200Tl, 182-215Pb, 188-218Bi...
Programme: FP5-HUMAN POTENTIAL
Record Number: 42586
Last updated on: 2006-11-28
Device to measure contrast over 10-12 orders of magnitude
The high dynamic correlator is based on an efficient all reflective attenuation system coupled with high efficiency thin nonlinear frequency conversion BBO crystals to keep ultra-short duration pulses with high intensity at the zero delay. The system allows to measure a contr...
Programme: FP5-HUMAN POTENTIAL
Record Number: 42573
Last updated on: 2006-11-28
12 3 4 5 6 7 8 9 10 > >| 
List retrieved on: 2018-08-21