{"contenttype":"result","language":"en","availableLanguages":"en","rcn":"143536","id":"244821_PS","title":"Final Report Summary - ASSENT (Anode Sub-System Development \u0026 Optimisation for SOFC systems)","teaser":"ASSENT project was focused on the development of fuel and water management for SOFC systems. The fuel management, and especially recirculation, is a key question in achieving high electric efficiency and rejecting external water supply. The recirculation...","summary":"\n\t\tExecutive Summary:\n\nASSENT project was focused on the development of fuel and water management for SOFC systems. The fuel management, and especially recirculation, is a key question in achieving high electric efficiency and rejecting external water supply. The recirculation increases the fuel utilization rate and can provide the water needed in the reforming of fuels. ASSENT project evaluated different process approaches for fuel and water management, e.g. blower-based approach, ejector-based approach, and water circulation by condensing from the anode off-gas\/exhaust gas and evaporating back to the fuel loop.\n\nIn this project four different optimised subsystems were developed and validated successfully: two in large-scale and two in small-scale. These subsystems solution could be implementable into a pre-commercial system after the project.\n\nBased on the cost analysis conducted within ASSENT and parallel CATION projects it can be concluded that with certain additional stack related development steps a commercially feasible system having investment cost (excl. stacks) of less than 2000 \u20ac\/kW can be achieved.\n\nProject Context and Objectives:\n\nThe objective of this project was to find optimal anode subsystem concepts that are validated for small-scale and large-scale SOFC systems to be implementable into a real system to fulfil performance, lifetime and cost targets for stationary applications. To find optimal anode subsystems to be validated, conceptual analysis and evaluation of the feasibility of the different recycle solutions for the anode subsystem was carried out. In addition, sensing techniques were tested, evaluated, and also developed, where available techniques were not sufficient. Optimum components should be viable for mass production.\n\nWhilst much effort and resources are devoted to cell and stack issues, less attention has been paid to the balance of plant, or components and sub-systems required for an operational system. Components and sub-systems such as fuel processing, heat and thermal management, humidification, fluid supply and management, and power electronics are as fundamental to successful commercialisation of fuel cell systems as the cell and stack. This is the main reason and basic idea which lead our consortium to propose this work. In this project the development work specifically addresses SOFC technology but some of the results might also support development of MCFC technology.\n\nThe main work of this project was in evaluating different process approaches for fuel and water management in the case of natural gas and biogas. Process approaches included e.g. fuel and recirculation management with a recycle blower-based approach and\/or an ejector-based approach, and water circulation with condensing from the anode off-gas\/exhaust gas and evaporating back to loop. Relevant process options were first evaluated on conceptual level and the results were used as a basis for detailed feasibility evaluation. The aspects taken into account in the conceptual analysis were effects on electric efficiency and process simplicity implying easiness of controllability, and requirements on diagnostics accuracy to provide insights into failure mode prevention. In detailed evaluation, the suitable approaches were analysed more thoroughly in terms of component availability and reliability, achievable diagnostics accuracy, controllability, effects on reformer, mechanical integration feasibility to whole system, safety control, failure mode prevention, cost effects etc..\n\nThe concrete and final work of the project was to validate optimal anode subsystem concepts in small-scale and large-scale SOFC systems to fulfil performance, lifetime and cost targets for stationary applications.\n\nProject Results:\n\nFour different optimised subsystems were validated successfully: two in large-scale and two in small-scale. These subsystems solution could be implementable into a pre-commercial system after the project.\n\nDedicated cost analysis (DtC) was conducted within ASSENT and parallel CATION projects to support the understanding of overall commercial feasibility of different process approaches. Based on this analysis, a good understanding on the economies of scale was achieved. As a result, it can be concluded that with certain additional stack related development steps a commercially feasible system having investment cost (excl. stacks) of less than 2000 \u20ac\/kW can be achieved.\n\nThe project has focused on the development of the whole anode subsystem because there were not commercially available anode subsystems or critical components, which could be utilised in SOFC technology. The project has increased the system understanding, developed diagnostic tools for controlling whole FC-systems and evaluated commercially viable subsystem solutions. This will help to develop sub-systems that are viable for mass production, and can be implemented into a real system to reach performance, lifetime and cost targets for stationary applications in upcoming pre-commercial demonstration projects.\n\nPotential Impact:\n\nSOFC technology is immature, but is seen as having more potential than other fuel cell technologies both in terms of applications and efficiencies and costs. Based on lower cost ceramic materials SOFC technologies are believed to have the greatest potential in becoming cost competitive with incumbent technologies. High electrical and CHP efficiencies will directly impact fuel supplies, whilst low or negligible NOx and SOx emissions and no particulate matter will contribute to cleaner air. SOFC units can therefore improve fuel security, sustainability, competitiveness, efficiency and flexibility, and lower carbon emissions that will contribute to meeting the objectives of Europe\u2019s Energy Policy. Looking into the future the fuel flexibility of SOFC systems will allow units to transition from the common hydro-carbon fuels of today through to future potential fuels such as bio-fuels and hydrogen. The focus will be on technologies for SOFC units with the potential for costs less than 1500-2000 \u20ac\/kW or 3000-4000 \u20ac\/kW for large- and small-scale applications respectively, have 40 000 - 60 000 hours durability and efficiencies of 45-60% in power generation mode and 80% + for CHP mode.\n\nThe nature of the project has been mainly technical and because of that it does not bring much relevant information for the policy makers or civil society. However, it brings a lot of information and good results for the industrial actors whose aim is to commercialise the fuel cell system.\n\nList of Websites:\n\nPublic website address: http:\/\/assent.vtt.fi\/\n\nDr. Jari Kiviaho\nCoordinator\nVTT Technical Research Centre of Finland\njari.kiviaho@vtt.fi\n+358 50 5116778\n\t\n\t","reportTypeDescription":"P-CSA-NoE Final Report","identifiers":{"reportId":"1175544"},"sourceUpdateDate":"2017-02-17 16:19:35","contentCreationDate":"2014-07-11 15:07:03","contentUpdateDate":"2014-07-11 15:09:56","lastUpdateDate":"2025-09-30 16:23:12","archivedDate":"2024-06-23 00:00:00","relations":{"associations":[{"availableLanguages":"de,en,es,fr,it,pl","rcn":"151149","id":"151149-enhancing-fuel-cell-efficiency","title":"Enhancing fuel cell efficiency","teaser":"Fuel cells and hydrogen have a potential for reducing emissions of greenhouse gases and air pollutants, facilitating the increased use of renewable energy sources, raising overall efficiencies of energy conversion.","contentUpdateDate":"2014-12-09 12:12:57","archivedDate":"2024-06-10 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"ener","title":"Energy","displayCode":"\/Energy","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"brief","title":"Result in Brief","description":"Article: Classic and enhanced","displayCode":"\/Result in Brief","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl,any","uri":"\/docs\/results\/images\/2014-12\/143536.jpg","mimetype":"image\/jpeg","size":"0","copyright":"\u00a9 Thinkstock","contenttype":"webItem","attributes":{"represents":"article","source":"editorial","type":"relatedImage"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"relatedArticle"}},{"availableLanguages":"en","rcn":"3116326","legalName":"TEKNOLOGIAN TUTKIMUSKESKUS VTT","address":{"country":"FI"},"contenttype":"organization","attributes":{"source":"sesam","type":"relatedOrganization"}},{"availableLanguages":"en","rcn":"94269","id":"244821","acronym":"ASSENT","title":"Anode Sub-System Development \u0026 Optimisation for SOFC systems","archivedDate":"2024-06-18 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/67\/423\/431","title":"water management","displayCode":"\/engineering and technology\/environmental engineering\/natural resources management\/water management","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/67\/425\/1173","title":"fuel cells","displayCode":"\/engineering and technology\/environmental engineering\/energy and fuels\/fuel cells","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"JTI-CP-FCH","title":"Joint Technology Initiatives -  Collaborative Project (FCH)","displayCode":"\/Joint Technology Initiatives -  Collaborative Project (FCH)","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"de,en,es,fr,it,pl","rcn":"870","id":"FP7-JTI","code":"FP7-JTI","frameworkProgramme":"FP7","pga":"FP7-JTI","title":"Specific Programme \u0022Cooperation\u0022: Joint Technology Initiatives","shortTitle":"Joint Technology Initiatives","parent":{"rcn":"846\/1401\/837","code":"FP7-COOPERATION\/EC\/FP7"},"archivedDate":"2024-06-12 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"legalbasis","title":"Legal Basis","description":"Programme: Legal basis for research funding","displayCode":"\/Legal Basis","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedLegalBasis"}},{"availableLanguages":"en","rcn":"11950","id":"FP7_SP1-JTI-FCH-3.2","code":"SP1-JTI-FCH-3.2","frameworkProgramme":"FP7","title":"Component and system improvement for stationary applications","parent":{"rcn":"11948\/11937\/11928\/870\/846\/1401\/837","code":"SP1-JTI-FCH-3\/SP1-JTI-FCH\/SP1-JTI\/FP7-JTI\/FP7-COOPERATION\/EC\/FP7"},"archivedDate":"2024-06-14 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"topic","title":"Topic","description":"Programme: Part of the Commission work programme implementing legal basis","displayCode":"\/Topic","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedTopic"}}]},"contenttype":"project","attributes":{"source":"sesam","type":"relatedProject"}},{"language":"en","availableLanguages":"en,any","uri":"\/docs\/results\/244821\/final1-fr-assent-summary.pdf","mimetype":"application\/pdf","size":"239487","contenttype":"webItem","attributes":{"source":"sesam","type":"relatedResultAttachment"}}],"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"pubsum","title":"Report Summary","description":"Result: Publishable summary (FP7 SESAM) and Summary for publication (H2020 SyGMa)","displayCode":"\/Report Summary","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"sesam","title":"SESAM","description":"RTD FP7 reporting system (including FP6 Marie Curie)","displayCode":"\/SESAM","attributes":{"classification":"source","type":"isProvidedBy"}}],"regions":[{"name":"Finland","rcn":"256543272","nutsCode":"FI","euCode":"FI","isoCode":"FI","attributes":{"source":"sesam","type":"relatedRegion"}}]},"modelVersion":"132","icaVersion":"20.0.0-48f81e07"}