{"contenttype":"result","language":"en","availableLanguages":"en","rcn":"184166","id":"605445_PS","title":"Final Report Summary - HIGHWET (Performance and validation of HIGH-rate constructed WETlands)","teaser":"Executive Summary:Even though the Water Framework Directive 2000\/60\/EC, concerning urban WW treatment, forces to treat sewage, there are a lot of small and medium size towns without this service. In addition, many of them cannot deal with energy and maintenance costs of...","summary":"Executive Summary:\nEven though the Water Framework Directive 2000\/60\/EC, concerning urban WW treatment, forces to treat sewage, there are a lot of small and medium size towns without this service. In addition, many of them cannot deal with energy and maintenance costs of conventional treatment plants making them unsustainable and uneconomic. This is the strong point of extensive technologies like constructed wetlands (CWs). In an economic crisis context, small populations, farms and small F\u0026B industries, must study long-term costs, so it could be an opportunity for low cost technologies like CWs\nThe HIGHWET project (Grant Agreement N\u00ba: 605445) aimed to perform and validate new approaches of Horizontal and Vertical Constructed Wetlands (HCW and VCW) including innovative materials as gravel bed and aeration devices for increasing biological development by implementing hybrid configurations (anaerobic - CW systems) for decreasing required surface of conventional horizontal CWs. \nThree European lead-user SMEs collaborated with two RTD performers to obtain new wastewater (WW) plant configurations based on anaerobic digestion and CW in order to exploit new markets: small towns, industrial Food and Beverage (F\u0026B) and agriculture (livestock farms) sectors. Currently, the towns and companies of these sectors have inefficient and expensive WW treatment systems. In this way, HIGHWET project had a food sector large enterprise as end-user to validate the performance of this new technology and regional water agencies and local government as stakeholders interested in definition of HIGHWET systems and final results.\n\nProject Context and Objectives:\nThe HIGHWET project aims to perform and validate new approaches of vertical and horizontal constructed wetlands (CWs) including innovative materials as gravel bed and aeration devices for increasing biological development by implementing hybrid configurations (anaerobic - CW systems) for decreasing required surface of conventional horizontal CWs. The outcomes of the project have been the performance of holistic HIGHWET systems capable of operating at high loading rates treating municipal and industrial wastewater (WW). Furthermore, new operation strategies were carried out in order to avoid the gravel bed clogging and extend the lifetime of the systems. \nTwo configurations have been validated in HIGHWET project. The first configuration consisted of a hybrid hydrolytic anaerobic digester (HUSB) and horizontal CW (HCW) system for raw municipal WW treatment, while second configuration consisted of a combination of HUSB reactor, vertical CW (VCW) and aerated HCW for treatment of high load organic industrial WW. These HIGHWET systems contained an effluent recirculation, air distribution systems and specific natural material in order to configure high rate technologies capable of being clear competitive treatment alternatives to high rate aerobic technologies (Membrane Bioreactor or Extended Aeration reactor) with operation and maintenance (O\u0026M) complex and expensive.\nThe project objectives as included in GA-Annex I are as follows:\nO1. Design, implementation and validation AD-HCW for urban WW. (Related with WP1, 2, 3, 4 and D1.1, and WP2 and 3 deliverables). Achieved in Month 14.\nO2. Design, implementation and validation AD-VCW-HCW for industrial WW. (Related with WP1, 2, 3, 4 and D1.1, and WP2 and 3 deliverables). Achieved in Month 14.\nO3. Development of an innovative air distribution system. (Related with WP2, 4 and D2.3). Achieved in Month 11.\nO4. Implementation of natural waste material\/aggregate as gravel bed. (Related with WP2, 5 and D2.3). Achieved in Month 11.\nO5. Operation strategy of the HIGHWET systems. (Related with WP4 and WP4 Deliverables). Achieved in Month 24.\nSocietal-economic targets (Related with WP1, 5 and D1.2, D5.2 and D5.3). Achieved in Month 24.\nEnvironmental impacts (Related with WP4 and D1.2 and D4.3). Achieved in Month 24.\nSome delays of first objectives were due to some inconveniences regarding pilot plants implementation during WP2 but this delay was recovered during the 2nd period of the project achieving a 100% accomplishment of all proposed objectives at the end of the project (Month 24).\nIn GA-Annex I, the objectives are directly related with most of project deliverables, which allows assessing and measuring the accomplishment of objectives and evaluate the project status during its performance.\n\nProject Results:\nThe work plan followed in HIGHWET project is structured into six work packages (WP) divided into different tasks, each one having a distinctive role towards the accomplishment of the project objectives.\nThe main research activities have been focused on defining, designing, implementing and validating the two HIGHWET pilot plants to be developed in the project for treating municipal and industrial wastewater. In this sense, the field scale plant configurations of anaerobic digestion and horizontal and vertical flow constructed wetlands systems have been specified, designed, constructed, implemented and validated. The two types of configurations validated during the project were the following:\n1. 1st Configuration pilot plant: Anaerobic hydrolytic (HUSB) reactor + HCW systems \n2. 2nd Configuration pilot plant: HUSB reactor + two stage CW systems (VCW+HCW)\nThe global contribution of HIGHWET project to improve the knowledge or technological process of CWs as WW treatment alternative was to develop holistic configurations combining hydrolytic anaerobic digester (HUSB) and vertical and horizontal CWs capable of operating at high loading rate of about 20-50 g BOD\/m2d (for the overall system and according the configuration), thus reducing the land requirements by a factor of 2 to 4 regarding conventional CWs. The overall configurations and their components maintain the simplicity of construction and operation of classical anaerobic digesters, HCW and VCW units, but increasing the overall performance of the system through limited artificial aeration and optionally through effluent recycling. The behaviour of the configurations in relation to solids accumulation and energy consumption was also investigated in order to determine its lifetime and general sustainability. In WP2, design, construction or adaptation of hydrolytic anaerobic technologies and aerated vertical and horizontal flow constructed wetland systems were carried out. The start-up and steady-state operation of systems and the validation of HIGHWET configurations were developed in WP3 and WP4 respectively.\nThe first HIGHWET configuration consisted of a hybrid hydrolytic anaerobic reactor (HUSB) and HCW and it was focused on the treatment of municipal wastewater. This configuration was implemented and validated by HUMIGAL and AIMEN.\nThe organic load of the influent (raw municipal wastewater) was at least 300 mgBOD\/l, in order to achieve the high organic load in the systems. In case that the targeted concentration was not achieved, some addition of substances with organic load, such as starch, molasses, vinegar and\/or urea was added to the influent flow to reach the desired concentration.\nThe pilot plant, located at UDC premises (University of A Coru\u00f1a), consisted of a hydrolytic anaerobic system followed by a one-stage HCW system.\nThe second HIGHWET configuration was designed for high organic industrial or agricultural wastewater treatment. The technology was constructed and validated by KILIAN and AU. \nThe organic load of the influent (raw industrial wastewater) was at least 5000 mgBOD\/l in order to achieve the high organic load in the systems. In case that this concentration was not achieved, some additions like starch solution and\/or oil and grease were added to the influent flow.\nThe validation of the plant was carried out at a maximum organic and hydraulic loading rate of 100 gBOD5\/m2d and 500-600 mm\/d, respectively. On the other hand, the target effluent characteristics to be achieved in the systems were: 10 mgBOD\/L; 10 mgTSS\/L; 20 mg N total\/L and 10 mg P total\/L. KILIAN and AU were responsible of the main operation and research in this pilot plant and RIETLAND contributed in the implementation (installation, adjustment, checking test), starting operation and validation of the aeration systems in the vertical and horizontal CWs.\n\nPotential Impact:\nOne of the main benefits for HIGHWET SMEs is the opportunity to introduce CWs in new markets, where large companies have not been successful. One potential market is Urban WWTP in small towns (below 10,000 population equivalent - PE). Nowadays, some European countries, (i.e. Belgium, France, Ireland, Italy, Luxembourg, Poland, Portugal and Spain) still need to make substantial efforts to improve their compliance with Directive 91\/271\/EEC (article 4 and 5). Significant investments in these countries have to continue for the necessary improvements of WW treatment of these agglomerations. Conventional CWs have been used in small villages (100-1,000 PE) as an economical alternative to conventional aerobic treatments. But the required conventional CW land for medium size town sanitation entails economic and social limitations.\nAlso, HIGHWET systems are designed to treat higher organic load WW requiring less area than conventional CWs. Therefore, HIGHWET configurations are suitable to treat organic industrial WW. Currently, there are about 286,000 companies of Food \u0026 Beverage industrial sector in the EU, 99.1% of them being SMEs with 2.9 million employees in total (Food Drink Europe, Data \u0026 Trends 2014). Many of these F\u0026B companies could be end-users of HIGHWET solutions since their WW composition is suitable to be treated in HIGHWET systems. Table 5 summarises the potential market for HIGHWET project outcomes.\nRegarding high organic load WW, an additional potential market is the wastewater of livestock farms (in case of swine manure, an aerobic pre-treatment is necessary to apply HIGHWET systems). There are more than 12 million livestock farms in Europe (EUROSTAT, 2015). Many of them do not have WW treatment and use their liquid effluents directly as fertilizer on surrounding lands. This has a high environmental impact, especially in large farms (with more than 10 hectares of agricultural area), which represent 19.8% of all farms in the EU (2,425,000 farms). This means a lot of new potential customers that HIGHWET SMEs could access with the technology developed. However, the market penetration will be slower than in the other markets due to livestock farms could be more reluctant to install WW treatments and its market share will be negligible at this stage. \nIt is obvious that urban and industrial wastewater treatment is important to fulfill the water quality requirements of Water Framework Directive. Moreover, Directive 91\/271\/EEC concerning urban WW treatment states than every town of 2,000-10,000 PE and F\u0026B companies with WW flows higher to 4,000 PE must set up collection and treatment systems. Also, some F\u0026B companies are affected by Directive 2010\/75\/EU on industrial emissions (integrated pollution prevention and control \u2013IPPC-). Difficulties to comply this legislation are reported due to current infrastructure cannot always achieve Directive quality standards (i.e. Belgium, Ireland, Italy and Portugal). \nThe main advantage of a HIGHWET European approach is that the system is able to provide a solution for F\u0026B industry and small town WW treatment in different location across EU. This is possible due to similarities in WW characteristics and legislation in EU.\nTechnologies such as applied in conventional WWTP are not the best solution for small towns and F\u0026B SMEs, due to its high investment and maintenance cost. Therefore, HIGHWET project results are a potential solution in these cases. HIGHWET systems are low cost and easy to operate and maintain. \n\nMain dissemination activities:\n- Project website.\n- A Short project video of HIGHWET project.\n- Poster prepared for diffusion of the objectives of the HIGHWET project.\n- Flyers printed to disseminate the main features of the HIGHWET project.\n- Letter of invitation to HIGHWET Public seminar and stakeholder meetings.\n\nList of Websites:\nwww.highwet.eu\n","reportTypeDescription":"SG SME Final Report","identifiers":{"reportId":"1305769"},"sourceUpdateDate":"2017-02-21 16:35:53","contentCreationDate":"2016-06-02 16:56:10","contentUpdateDate":"2016-06-02 16:59:01","lastUpdateDate":"2026-07-29 11:14:35","archivedDate":"2024-06-23 00:00:00","relations":{"associations":[{"availableLanguages":"de,en,es,fr,it,pl","rcn":"165119","id":"165119-europes-water-cleaned-up","title":"Europe\u0027s water cleaned up","teaser":"The purifying ability of wetlands has been harnessed to clean up Europe\u0027s water as a cheaper alternative to conventional wastewater treatment plants.","contentUpdateDate":"2016-10-28 18:34:57","archivedDate":"2024-06-10 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"indust","title":"Industrial Technologies","displayCode":"\/Industrial Technologies","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"brief","title":"Result in Brief","description":"Article: Classic and enhanced","displayCode":"\/Result in Brief","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl,any","uri":"\/docs\/results\/images\/2016-10\/165119.jpg","mimetype":"image\/jpeg","size":"0","copyright":"\u00a9 Official, Shutterstock","contenttype":"webItem","attributes":{"represents":"article","source":"editorial","type":"relatedImage"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"relatedArticle"}},{"availableLanguages":"en","rcn":"3110084","legalName":"ASOCIACION DE INVESTIGACION METALURGICA DEL NOROESTE","address":{"country":"ES"},"contenttype":"organization","attributes":{"source":"sesam","type":"relatedOrganization"}},{"availableLanguages":"en","rcn":"110448","id":"605445","acronym":"HIGHWET","title":"Performance and validation of HIGH-rate constructed WETlands","archivedDate":"2024-06-18 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/59\/377","title":"food technology","displayCode":"\/engineering and technology\/other engineering and technologies\/food technology","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/67\/89023697\/1183","title":"wastewater treatment processes","displayCode":"\/engineering and technology\/environmental engineering\/water treatment processes\/wastewater treatment processes","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/71\/443\/1195","title":"bioreactors","displayCode":"\/engineering and technology\/environmental biotechnology\/bioremediation\/bioreactors","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/27\/83\/501\/507","title":"animal husbandry","displayCode":"\/agricultural sciences\/animal and dairy science\/domestic animals\/animal husbandry","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"BSG-SME","title":"Research for SMEs","displayCode":"\/Research for SMEs","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"de,en,es,fr,it,pl","rcn":"862","id":"FP7-SME","code":"FP7-SME","frameworkProgramme":"FP7","pga":"FP7-SME","title":"Specific Programme \u0022Capacities\u0022: Research for the benefit of SMEs","shortTitle":"Research for the benefit of SMEs","parent":{"rcn":"847\/1401\/837","code":"FP7-CAPACITIES\/EC\/FP7"},"archivedDate":"2024-06-12 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"legalbasis","title":"Legal Basis","description":"Programme: Legal basis for research funding","displayCode":"\/Legal Basis","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedLegalBasis"}},{"availableLanguages":"en","rcn":"19144","id":"FP7_SME-2013-1","code":"SME-2013-1","frameworkProgramme":"FP7","title":"Research for SMEs","parent":{"rcn":"10384\/11727\/862\/847\/1401\/837","code":"SME-1\/SME\/FP7-SME\/FP7-CAPACITIES\/EC\/FP7"},"archivedDate":"2024-06-14 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"topic","title":"Topic","description":"Programme: Part of the Commission work programme implementing legal basis","displayCode":"\/Topic","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedTopic"}}]},"contenttype":"project","attributes":{"source":"sesam","type":"relatedProject"}},{"language":"en","availableLanguages":"en,any","uri":"\/docs\/results\/605\/605445\/final1-highwet_605445_publishable-summary_final-report.pdf","mimetype":"application\/pdf","size":"4475043","contenttype":"webItem","attributes":{"source":"sesam","type":"relatedResultAttachment"}}],"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"pubsum","title":"Report Summary","description":"Result: Publishable summary (FP7 SESAM) and Summary for publication (H2020 SyGMa)","displayCode":"\/Report Summary","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"sesam","title":"SESAM","description":"RTD FP7 reporting system (including FP6 Marie Curie)","displayCode":"\/SESAM","attributes":{"classification":"source","type":"isProvidedBy"}}],"regions":[{"name":"Spain","rcn":"242387496","nutsCode":"ES","euCode":"ES","isoCode":"ES","attributes":{"source":"sesam","type":"relatedRegion"}}]},"modelVersion":"132","icaVersion":"20.0.0-48f81e07"}