{"contenttype":"result","language":"en","availableLanguages":"en","rcn":"197705","id":"285411_PS","title":"Final Report Summary - MEEFS RETROFITTING (Multifunctional Energy Efficient Fa\u00e7ade System for Building Retrofitting)","teaser":"The key to greater energy efficiency lies in residential buildings which represent about 80% of the total building stock and 63% of the final energy consumption. MeeFS (Multifunctional Energy Efficient Fa\u00e7ade System for Building Retrofitting www.meefs-retrofitting.eu) was...","description":"final","summary":"Executive Summary:\nThe key to greater energy efficiency lies in residential buildings which represent about 80% of the total building stock and 63% of the final energy consumption. MeeFS (Multifunctional Energy Efficient Fa\u00e7ade System for Building Retrofitting www.meefs-retrofitting.eu) was conceived in order to address the development, evaluation, and demonstration of an innovative multifunctional fa\u00e7ade system geared towards the residential building sector, with the potential to significantly contribute to energy efficiency in buildings across Europe. The project started on 1st January 2012 coordinated by Acciona Infrastructures (Spain) and supported by partners from 9 different countries: Tecnalia, AST, Govern of Extremadura (Spain); E\u0026L Architects, SkaPolska (Poland); Greenovate! Europe (Belgium); CQFD, TBC (France); AntWorks, Vipiemme (Italy); Rizakos, NTUA (Greece); FHG (Germany); VTT (Finland) and Technion (Israel). The workflow was very challenging, linking: design, testing, redesigning, manufacturing and assembling. The biggest challenges in the last period were actually administrative in nature, especially as it took the project over a year to obtain the licences for the planned installation. In total it was five years of hard work and many lessons learnt. \n\nThe MeeFS multifunctional fa\u00e7ade system can be used as a retrofitting technique across Europe, with different buildings and climates. The panels have been designed to fit social housing buildings. After analysing hundreds and hundreds of housing typologies across Europe, it has been concluded that the building standards do of course differ depending on the year of construction, aesthetics and function, but overall they are quite similar. The panels have been developed accordingly using a modular system to fit any climate and housing situation. The anchorage system has been developed with special trays that can easily be adjusted to allow for different building sizes. \n\nThe site and building chosen for the demo site was in M\u00e9rida, and owned by only one institution - the local government - which always makes the execution a lot simpler. Further into the project, it was discovered that the building residents were in a very critical social predicament and this led to a number of technical issues that had to be solved on site, such as the redistribution of the panels on the fa\u00e7ade due to limits in access to apartments. The preliminary results from the demonstration buildings in Merida are very promising. The technical development and fine-tuning of the construction process was successful. However, the process of analysing simulations and gathering energy data is still ongoing. Final results, summing up the impact of the panels is expected in mid-2017. \n\nMeeFS has claimed a breakthrough in developing two technologies: the advanced passive solar protector \u0026 energy absorption unit and the advanced passive solar collector \u0026 ventilation unit. Both panels aim to increase energy efficiency, reducing the total energy demand and enhancing the indoor comfort of the building. To achieve this, the panels combine several technologies that are automatically adapted to the position of the panel and the climate. Depending on the season and time of day they are able to adjust to the specific energy demand of the building.\n\nSince the MeeFS system is an innovative technology, the feasibility of the system in terms of costs is still unsure: it costs more than the state-of-the-art technologies. On the other hand this technology has been proven to be easier to adapt to buildings and its effectiveness is higher than that of standard technologies. The MeeFS fa\u00e7ade system payback time is limited to seven years, so the panels are more energy efficient and offer greater savings in the long run. The panels have been designed to be adaptable to future technology as well, having a good chance of being competitive in maybe five to ten years.\n\nProject Context and Objectives:\nThe overall objective of the MeeFS project was the development, evaluation and demonstration of an innovative energy efficient multifunctional fa\u00e7ade system for residential building sector retrofitting. This new fa\u00e7ade system was to be easily adapted to any climate condition and any typology of residential building fa\u00e7ade.\n\nThe concept was based on an energy efficient integrated system composed of an innovative non-intrusive fa\u00e7ade concept, from composite materials, and advanced multifunctional panels with technological modules that will allow the integration of both active and passive technologies in the fa\u00e7ade. The system was designed for building envelope retrofitting, to drastically improve the energy efficiency of residential buildings in Europe.\n\nThe innovative concepts addressed the general ideas listed below:\n\nInnovative fa\u00e7ade concept for retrofitting:\n\u25aa\tits system of construction does not exist for retrofitting nowadays\n\u25aa\tallows the integration of advanced multifunctional panels and technological modules \n\u25aa\tstandardised dimensions for panels and modules according to the different fa\u00e7ade surface typologies\n\u25aa\tallows for industrialised production \n\u25aa\tallows personalised configurations for each fa\u00e7ade typology, orientation and local climate conditions, always using standardised panels and technological modules\n\u25aa\tlow intrusive, connected with the building through a reduced number of anchorage elements\n\u25aa\taesthetic and compatible with the existing building functions \n\u25aa\tthe volume of the scaffolding will be reduced during the retrofitting process\n\u25aa\tlow maintenance, easy assembly and disassembly \n\u25aa\tcost effective in service life, it will avoid future retrofitting using the same structural modules that can be upgraded with technological innovation along building life \n\u25aa\tintegration of the installations (building visible existing installation) in the fa\u00e7ade structure system, integration among them of the different fa\u00e7ade module installation and with the building internal installation system\n\u25aa\tit will improve the Indoor Environmental Quality\n\u25aa\tit will increase durability\n\nEnergy Efficient panels and modules:\n\u25aa\tall the modules integrated in the fa\u00e7ade include a particular technology (Active or Passive technologies) that will allow the reduction of the primary energy either reducing energy demand of the building or for supplying energy by means of RES (Renewable Energy Sources)  \n\u25aa\tmost of the modules will be state of the art already proven (to be cost effective and energy efficient)\n\u25aa\tthere will be two new energy efficient breakthrough modules developed in the project based on passive strategies under bioclimatic architecture principles \no\tAdvanced Passive Solar Protector and Energy Absorption auto mobile (sensors and actuators) unit for building fa\u00e7ades with thermal insulation, heat storage, heat reflection and ventilation properties according to the climate and temperature (outdoor and indoor) situation as well as sun radiation level at each moment \no\tAdvanced Passive Solar Collector and Ventilation Module for Building Fa\u00e7ades. Although the concept is known for new buildings, the application in retrofitting is new. The existing wall of the fa\u00e7ade can act as part of the system as an element for energy storage.\n\u25aa\tflexible combination of the different technologies in the modules will contribute to the global energy efficiency and to a higher indoor comfort \n\nInnovative fa\u00e7ade structure materials:\n\u25aa\tNew safe and cost effective composite materials based on improved thermoplastic polymers with better fire performance and environmental behaviour, with the following properties:\no\tHigh thermal properties avoiding thermal bridges \no\tLower embodied energy than aluminium and even recycled steel in the whole life cycle \no\tLower cost for the same performance\no\tLighter-weight than aluminium for the same structural performance\no\tImproved mechanical properties\no\tLow corrosive\no\tLong durability and less maintenance \no\tRecyclable \n\nEnergy efficient retrofitted building:\n\u25aa\tIt will obtain at least the energy efficiency of new buildings according to current national regulations. Each country transposes the directive 2010\/31\/EU demanding certain requirements. As an example, in Spain, where a demonstration building will be retrofitted, the transposition of the directive is realised through three royal decrees . The type and level of performance requirements for new buildings depend on the climatic zone where the building is located. The demonstrator located in Badajoz (Spain) will reach at least all the requirements  demanded for new buildings in this location.  \no\tMaximum U-value for external wall: 0.73 W\/m2 \u00baC\no\tMaximum U-value for windows oscillate between 2.2 and 4.4 W\/m2\u00baC depending on the fa\u00e7ade orientation \no\tMaximum solar factors for windows oscillate between 0.29 and 0.57 depending on the fa\u00e7ade orientation\no\tMinimum 70% solar contribution for the Domestic Hot Water (DHW)\no\tNo obligations for PV electric contribution for residential buildings\no\tNo obligations for Energy certification for existing buildings to be retrofitted. Minimum demanded certification in scale (A-G) is E in case of the new buildings. The objective is to obtain in our case A certification in the demonstrator. Values  for the energetic certification in Badajoz (Spain) count in KgCO2\/m2 emissions are: \nThe LIDER  is a software tool that permits to test the degree of compliance with the requirements of the Spanish technical code CTE mentioned above. The CALENER  is software tool for energetic certification (A-G).\n\u25aa\tAt least min. Indoor Environment Quality requirements as per CTE\n\u25aa\tBuilding Energy Management System incorporated \n\u25aa\tPay-back less than 7 years\n\nInnovative methodology for retrofitting\n\u25aa\tThe Integrated Project Delivery (IPD) Methodology will be used for the design, retrofitting, and commissioning of the building. It will be supported by BIM (Building Information Modelling)\n\nThe system will incorporate tools for system design composed by a Guide for design, retrofitting and commissioning for building to be retrofitted\no\tMethodology for fa\u00e7ade design that will be implemented \na.\tArchitectural Design, Structural Design and Construction Process\nb.\tEnergy Design (building on the existing passive and active design knowledge)\no\tA decision-support software tool for the design of the facade (optimum modules combination), depending on the energy efficiency requirements while achieving and\/or maintaining the aesthetical values.\no\tGuide for using and maintaining the facade system. \n\nThe design guide with the decision-support software tool and maintenance guide will be also used after the project by designers for retrofitting buildings.\nTo achieve the objectives, the work plan was structured in 11 WPs. WP1 to WP8 are devoted to research activities and corresponding technical \u0026 scientific management\/coordination, WP9 deals with the demonstration activities and WP10 deals with innovative exploitation \u0026 dissemination related activities, WP11 is devoted to project financial, legal and administrative management.\n\nProject Results:\n60 months into the Multifunctional Energy Efficiency Fa\u00e7ade (MeeFS) project the consortium has completed all project phases (WPs), related to the architecture and energy fa\u00e7ade shaping, and concluded with the demonstration and exploitation in residential building in M\u00e9rida, Spain.\nArchitectural \u0026 Structural System Design [WP1]\n\nThe primary goal of this work package was to develop the architectural system of the modular fa\u00e7ade, taking into account technical and aesthetic criteria, taking into account the existing multi-family building stock in the EU, introducing innovative approaches to retrofitting philosophy: the fa\u00e7ade is not only the external \u201cface\u201d of the building, but also integrates itself with the building\u2019s technical installations, adding new value and functionality helping to reduce energy expenditure and improving the living conditions of dwellers. The work planned was successfully completed, creating the revolutionary fa\u00e7ade system from the ground up, developing all-new structural elements, dealing with innovative materials and solutions, using original, state-of-the-art building technologies. Careful analysis of the residential building typologies and legal aspects in respective EU countries inspired the standard fa\u00e7ade system module dimensions and the definition of the standard fa\u00e7ade structural system elements (panel, module, assembling system) for building retrofitting across Europe. In addition the analysis of climatic conditions in respective EU countries, taken in different work packages related to this, leads to economically efficient integration of existing and new building\u2019s technical installations into the multifunctional structurally uniformed fa\u00e7ade system.  Finally, the introduction of BIM parametric objects with embedded parametric data has been considered, for the creation of custom BIM libraries with MeeFS objects. At the end of the project the basic fa\u00e7ade project guidelines were prepared, to summarise the architectural and structural developments.\n\nThe work has been organised in different steps, starting with outlining the design for the main fa\u00e7ade system elements, its sizes and position on the fa\u00e7ade, and concluding with the proposed design for an anchorage system. As a result of studying the various types of facade data from EU countries, the most important set of fa\u00e7ade parameters was defined, thus creating the typology scheme for the MeeFS system. One of the crucial dimensions to be defined was the distance between the different slabs for the considered residential buildings, and the position of the main fixing points for the innovative fa\u00e7ade system. The results of this study showed that most of the dimensions are not so different between countries, although not the same of course. The distances between slabs are different according to the country. In fact, buildings in the North Zone have distances longer than 3 metres (Germany and UK for example), and in the South and Central, shorter than 3 metres (like Poland and Spain). The average of all these distances is very different by country too, and at this moment it was clear that it was not possible to make only one module dimension. It is feasible to group some countries with similar dimensions together, like Finland with no standard dimensions, Germany and UK (and possibly Italy and Greece) where the dimensions are between 3,1 and 3 metres, Poland and Spain: under 3 metres (in one case 2.7 metres and the other one 2.4 metres). In conclusion it was decided that for the MeeFS facade it would be useful to create two different dimensions: a standard for North countries (3.05 metres) and a second one for the South ones (less than 3 metres). The deeper studies were done with help of the \u201cVirtual Mesh\u201d (VM), a tool designed for this analysis, to help extract generic dimensions from the catalogue of building typologies. VM was applied over the pictures\/drawings and it allowed us to create axes and to generate automatic dimension between axes. These axes can be drawn to the building\u2019s outline, windows distances, slab distances and all the necessary geometry to describe the fa\u00e7ade.\nThe outcomes from the initial studies and first drawings propositions on the panel, module and unit dimensions helped to inform the anchorage system to be designed for fa\u00e7ade. On one side it should be used to fix all the different elements, with the main objective to integrate them and fix them to the retrofitted building. Instead of using single anchoring elements as initially planned, the proposal for this project consists of using an anchoring tray, fixed in several points to the floor slab, where the multifunctional panels can be mounted and adjusted individually. The design of the tray considers the mechanical components, allowing the panels to be placed at slightly different vertical positions, absorbing the differences between the slabs dimensions. An additional feature of this tray is that it provides an area for the installation components and the passage of piping and wiring, necessary for the appropriate operation of this energy- efficient fa\u00e7ade system.\n\nContinuing with the detailed design of panels, modules and mechanical joints, technological units, its particular elements and architectural details, finally the architectural and structural design for the system was expanded in time. It was crucial to allow the fa\u00e7ade design to adapt to the proprietary needs of the manufacturing process and material pre-selected for its execution. In close collaboration with the activities related to the material and manufacturing of the structural profile [WP7], the pre-testing campaign has been planned to decide definitely on the structural material between aluminum and composite for profile (fire requirements and manufacturing trials), in continuation for the module for technological unit. As an initial constraint the aluminium was chosen for the module structure due to its better fire behaviour and design flexibility. To avoid thermal bridges through the metallic structural module several options were analysed based on the common idea of dividing the profile in two elements: the introduction of an intermediate rubber element to break the bridge; the combination of an aluminium element with a plastic element with good LCA. The design of the structural module has been modified to create the facilities channels and to isolate each technological units\u2019 effect to avoid unwanted interactions through the common air gap. Finally, having finalised the fire testing for the composite material, and due to the initial positive results, the selection of the composite for the fa\u00e7ade main structural element has been decided for main panel support, alongside the aluminium for technological units also agreed.  \n\nTo achieve the final goal of work package - the complete definition of the multidisciplinary MeeFS fa\u00e7ade\u2019s system - first the valuable building data analysis parts (several branches) were performed and all relevant information has been crossed with the data on different disciplines like installations, energy system, technological units constrains coming from the different task and work package related to them. Basing on the initial summary, the BIM (ArchiCAD) parametric objects were created for major system elements. Energetic, structural, material properties and cost data was added to parametric objects. Those objects were subsequently put in BIM libraries \u2013 created exclusively for the MeeFS Fa\u00e7ade System. Concluding the summary of all data, the demo Fa\u00e7ade Project has been prepared \u2013 in the basic form of Building Permit design drawings. \nIn continuation, all outputs from the architectural and structural design have been presented, from the generic design to the specific demo design in the residential building in M\u00e9rida, province of Badajoz, Extremadura region, Spain.  [WP9] (The design file was further developed and adjusted in order to comply with the Spanish Local Law Requirements and its Mandatory Tests for the whole system. The overall MeeFS System guidelines were adapted to the demo building. The documentation was first prepared at the Basic Project level and after consortium approval, the preparation of the Execution Project begun \u2013 it was then finally concluded with testing, and deeply designed below the work package related to demo [WP9].\n\nOnce the Mandatory Testing for the whole system was successful, and the fa\u00e7ade design was finally closed, the MeeFS Consortium requested the Building Permit to be issued by the National Spanish Government Entity from Extremadura. After being granted a Building Permit, the construction works commenced, according to the Execution Design, and were constantly upgraded and revised in collaboration with fa\u00e7ade designers and demo Teams [WP1 and WP9], local Merida architects and the Main Contractor (execution) team. \n\nEnergetic System Design [WP2]\n\nThe MeeFS project energy concept is built on the technological units integrated into the architectural and structural fa\u00e7ade system, capable of reducing the energy consumption and improving the indoor comfort of poorly insulated residential buildings across Europe. In the context of defining the appropriate energy system technology configurations for different climatic conditions and residential building types, a multi-step approach has been followed, aimed at determining representative building energy requirements for energy efficiency and indoor comfort. Building energy consumption generally depends on the external weather conditions, building characteristics and heating, cooling and ventilation (HVAC) systems. Therefore, a thorough analysis of past and ongoing European and national research projects has been carried out in order to obtain information regarding climatic characteristics, HVAC installations typologies and typical building typologies across Europe.\nInitially, major European climatic zones have been identified by analysing the climatic conditions in all European Union countries; 3 different climatic zones have been defined, namely \u201cNorth\u201d (Dfb and Dfc climate categories in the Koeppen-Geiger climate classification system), \u201cCentral\u201d (Cfb and Dfc) and \u201cSouth\u201d (Csa and Cfb), which reflect significant climatic differences. Analysis of the European climate diversity has led to the selection of 13 representative cities, for which fa\u00e7ade wall characteristics of existing buildings have been thoroughly studied. A detailed classification of the most common fa\u00e7ade and external wall typologies, in terms of materials used and U-values, has been also performed, to determine the most representative external wall compositions for the MeeFS target buildings. Finally, a thorough classification study of the most common HVAC installations across Europe has been performed, aiming to determine the most typical installations used in residential buildings across Europe. \nThe fa\u00e7ade, being a part of the building envelope, separates the outdoor and indoor environments, functioning as a thermal insulation and air tight barrier; visual contact to outdoors is also allowed through windows. The MeeFS Technological Units (TU) were designed to cover these main functions and also add new functionalities, while reducing the overall building energy consumption. Aiming to determine the main characteristics of the MeeFS TU to be developed, results of the aforementioned classification studies have been used, in conjunction with EPDB requirements, in order to perform a series of building energy simulations; simulation results yielded a range of average energy demand and consumption values for typical building configurations across Europe. Once areas of energy performance improvements have been identified for the simulated buildings, located in 13 characteristic European cities, a broad range of alternative technologies and solutions that can be integrated into the MeeFS system have been analysed and comparatively assessed.\nThe obtained results served as a starting point for the definition of the basic design requirements for the TU to be developed in the MeeFS project. 7 types of state of the art technologies have been considered initially for the MeeFS TU design, namely Building Integration Photovoltaic (BIPV), Insulation Panel, Ventilated Fa\u00e7ade, Green Fa\u00e7ade, Glazing, Solar Protection and Fa\u00e7ade Integrated Solar Thermal Collectors. Aiming to comparatively assess these 7 technologies and determine their applicability for the MeeFS system, a series of building energy simulations has been performed, in conjunction with a thorough cost analysis, based on energy savings and payback calculations. The energy savings for each TU were determined using building energy simulation software tools, for 5 representative cities (Athens, Madrid, Paris, Berlin and Helsinki), covering all 3 European climatic zones. In each of the 5 investigated cities, representative wall and HVAC equipment configurations were used; all 4 possible main fa\u00e7ade wall orientations (N, E, S, W) have been taken into account. Overall, almost 400 simulations have been performed. Simulation results were employed to quantify the energy consumption for HVAC purposes before (\u201ccurrent\u201d configuration) and after (\u201cretrofitted\u201d configuration) the implementation of each TU. The obtained simulation results were used to evaluate and compare the potential energy savings of each TU. Significant savings in energy demand were calculated, especially for the \u201cSouth\u201d and \u201cCentral\u201d zones, where buildings are usually not very well insulated, thus resulting in high projected gains in heating energy consumption. The estimated maximum energy savings are presented in the following table; significant potential energy savings, up to 60% are reported. However, since in the simulated \u201cbase case\u201d apartment, all walls were assumed to be adiabatic, except from the fa\u00e7ade, the obtained results corresponded essentially to a theoretical \u201cbest case scenario\u201d; application of the MeeFS TU in real buildings is expected to yield lower actual energy saving values.\nAdditional information regarding the costs associated with the construction of each TU allowed the estimation of the respective payback period. In addition, a methodology to estimate non-monetary benefits has been developed, aiming to evaluate the sustainability of the TU by taking into account a broad range of economic, environmental and social factors like energy savings, low maintenance, recyclability, aesthetics, thermal insulation and reduction of cooling and heating energy demand, reduction of CO2, fire protection, comfort, healthy living, energy independence between the most important of them.\n\nResults of the aforementioned assessment methodology, allowed to determine the 7 TU types to be developed in the frame of the MeeFS system: Building Integration Photovoltaic, Insulation Panel, Ventilated Fa\u00e7ade, Green Fa\u00e7ade, Solar Protection, Advanced Passive Solar Protector and Energy Absorption Unit [WP3], Advanced Passive Solar Collector and Ventilation Unit [WP4]. After the basic characteristics of the 7 TU have been defined, research activities focused on the determination of the final detailed design for each TU, taking into account the structural design, the fa\u00e7ade system installation design and the energy saving strategy across Europe. The final detailed design comprised the overall description of the TU, where information on a broad range of matters, such as functional description of the TU, layout of each required component and auxiliary system, architectural design, anchoring system, auxiliary systems and installations requirements, location layout, range of validity across Europe, possible location of the TU on a fa\u00e7ade, location of connections for its integration in the fa\u00e7ade structure, location of ducts and wiring, possible installation restrictions, were given. Once the final detailed design stage had been reached, the following step was the determination of the manufacturing process of the 7 TU, including all relevant components, e.g. materials, systems and facilities, necessary to produce each final technological module, ready to be assembled to the MeeFS multifunctional panel. Detailed building energy simulations were once more performed for the final TU configurations, for 5 typical European cities; these simulations were accompanied by cost-effectiveness and non-monetary benefits evaluation.\n\nA \u201cgeneral rules of design\u201d handbook was subsequently created, aiming to provide guidelines and general rules for TU selection in the context of a fa\u00e7ade refurbishment process across Europe. The first part of the handbook provides some guidelines to the user in order to select the appropriate climatic zone, initial external wall level of performance and initial windows level of performance. Guidelines are given in a checklist style mode and in tables. Towards this end, a variety of building classification rules were defined. For instance, two alternative methodologies were employed for climatic classification, the first one using \u201cheating degree days\u201d (HDD) and \u201ccooling degree days\u201d (CDD), while in the second one a list of European countries is used. Also, regarding the initial state of the external wall, various methodologies were employed, such as consideration of the U-values of the external wall (when available), consideration of the thickness of insulation (when available) or consideration of the age of the building and (when available) the date of any previous retrofitting. Finally, in terms of the initial state of the glazed areas, two classification methodologies were developed, by either considering the U-values of the windows (when available) or estimating them by considering the age of the building and (when available) the date of any previous retrofitting. The second part of the handbook allows the pre-selection of TU for the investigated building. By taking into account the energy strategy defined in the previous step, as well as special requirements given by the user, a set of suitable TU is proposed to be implemented on the building. The user is allowed to remove some of the TU for aesthetic, technological or any other reasons. Finally, the last part of the handbook allows calculation of estimated energy savings. The final TU selection is based on building energy simulation results stored in a dedicated database, which has been developed for a set of typical buildings across 13 representative European cities, by employing results obtained from approximately 1400 building energy simulations. The projected energy savings for the investigated building are determined considering the closest initial state and climatic condition compared to the one considered in the database. Different TU combination alternatives are proposed for each fa\u00e7ade and corresponding energy gains and payback periods are reported.\n\nIn addition, detailed simulations have been performed in an effort to assess the impact of the proposed MeeFS system on the thermal and energy consumption behaviour of the demonstration building. In this context, a series of \u201cthermal bridge\u201d simulations has been performed initially, aiming to assess the \u201cthermal interaction\u201d between the MeeFS system and the existing building fa\u00e7ade. A detailed building energy simulation model of the demonstration building has been developed, covering both the \u201cpre-installation\u201d and \u201cpost-installation\u201d configurations. Since 8 different apartments of the demonstration building, located on the 2nd and 3rd floor, were considered for the MeeFS energy retrofitting process, 8 individual models have been developed, taking into account all available information pertinent to each apartment (e.g. external and internal dimensions, construction materials, internal layout, occupant characteristics, installed heating and cooling appliances etc.). A detailed monitoring system, using an extended sensor network, was installed in 3 of these apartments, aiming to provide a detailed account of the temporal evolution of a range of important parameters (e.g. outdoor and indoor temperature and humidity, wall surface temperature and heat flux, indoor velocity). The obtained monitoring data, covering a period of 18 months before the MeeFS system installation (\u201cpre-installation\u201d period) and 2 months after the energy retrofitting (\u201cpost-installation\u201d period) have been used to validate the developed models.\n\nA series of building energy simulations has been performed, using the EnergyPlus software tool. All simulations covered a period of one year, using a 1 hr time step, the sole exception being the \u201cpost-installation\u201d validation study, where only a 2 month period, corresponding to the period for which monitoring results were available, was addressed. Initially, all 8 apartments were simulated in their \u201cpre-installation\u201d state, aiming to assess their thermal performance. In this context, comparison of the obtained predictions with available monitoring data provided a means of validation for the developed simulation models; good levels of agreement have been observed, given the complex nature of the simulations, especially regarding the stochastic nature of real life occupant behaviour. Energy simulations allowed an estimation of the annual energy demand for heating and cooling purposes for each apartment considered. It should be noted that due to the construction characteristics of the demonstration building (relatively new building, adequately insulated) its thermal and energetic performance before the retrofitting process were found to be quite good, thus suggesting that rather modest energy savings were expected after the retrofitting process. In order to determine the \u201cpost-retrofitting\u201d building energy behaviour, a specific simulation model for each TU has been developed; the respective models have then been introduced in the EnergyPlus simulation tool. Once more, the obtained numerical results have been validated by means of comparison with available \u201cpost-retrofitting\u201d monitoring data; in this case, slightly worse levels of agreement have been achieved, owed mainly to the complex thermal interactions between the various TU installed in each monitored apartment. A series of further \u201cpost-retrofitting\u201d energy simulations yielded estimations of the potential energy savings that can be achieved either by each individual TU or by the specific TU combination used in each of the 8 apartments of the demonstration building. On average, savings in energy demand were found to be of the order of 15% (c.f. figure below).\n\nAs expected, due to the good thermal performance of the demonstration building even before the MeeFS system retrofitting, the achieved levels of energy savings (15%) were lower than that previously calculated for older and badly insulated buildings that constitute the main \u201ctarget group\u201d of the MeeFS retrofitting project. The best \u201coverall\u201d performing TU type was found to be the \u201cSolar Protection TU\u201d, whereas in terms of reducing energy demands for \u201cheating\u201d purposes only, both the \u201cInsulation Panel TU\u201d and the \u201cAdvanced Passive Solar Collector \u0026 Ventilation Unit TU\u201d were found to yield energy savings higher than 18%. Finally, a further series of simulations has been performed, assuming that the demonstration building, in both its \u201cpre-installation\u201d and \u201cpost-installation\u201d configurations, is located in two alternative European cities (Berlin, Helsinki), corresponding to significantly different climatic conditions (\u201cCentral\u201d, \u201cNorth\u201d). In this case, maximum energy demand savings were found to be somewhat lower (up to 11%), a fact that clearly illustrates the need for optimising the TU type selection and distribution for each specific climatic region.\nAdvanced Passive Solar Protector and Energy Absorption Unit [WP3]\n\nThe development of the breakthrough fa\u00e7ade units [WP3, WP4], in this case Advanced Passive Solar Protector and Energy Absorption Unit, has been proposed to complete the selection on state of the art technological unit developed under previous work package [WP2] with the innovative one. The aim was to improve the annual energy performance of the buildings to be retrofitted, balancing heating and cooling requirements. For that purpose the conceptual design of the Technological Unit was developed, defining its constructive design and operating system for its integrations to the MeeFS system. Based on the previous conceptual design, an advanced design for the unit was developed with specific metallic and plastic profiles that guaranteed the correct integration of PCM, insulation material and coating, the water tightness and thermal bridge break. New energy and CFD simulations were performed to evaluate its energy performance in different European climates. \nSeveral approaches have been studied to identify and integrate all the required components and to achieve an optimal design. The most suitable unit configurations have been established with the best annual energy performance balance of heating and cooling loads for different climate locations and orientations in the target geographic locations defined for the MeeFS system. It has been evaluated energetically using energy simulation software tools to improve its potential to reduce building energy loads by optimising its components and operating system. \n\nTo ensure the Technical Unit thermal performance a prototype is being developed to test and evaluate its results. Two prototypes with different PCM materials were built to evaluate the performance under real climatic conditions. These prototypes were installed and evaluated in Acciona\u2019s test-cell facilities in Seville (south Spain). A special software tool was developed to gather and evaluate the prototypes performance. The evaluation of the prototypes concluded that no physical modifications were needed. The modifications detected were focused on its mechanical and control systems. The components description has been organised depending on their location and use, and detail definition made for slats, frame, mechanical and control system components.\nThe manufacturing steps have been defined, and detailed drawings on manufacturing components prepared, estimating for every step the time needed and cost estimation. From material gathering, components assembly, structure fixing, to facilities connectors, including labour works. The ASP\u0026EA units was manufactured and tested in April 2015, and has passed all mandatory tests necessary for a demonstration building. At this research phase the cost is high, compared with the state of the art components, but the industrialised cost in case of a large scale production is expected to be lower. Using the experience obtained during the prototypes manufacturing process a final design for the unit has also been defined. Due to the time limits on demonstration, and some contractual problems with the current manufacturer of the unit, the decision had to be taken not to consider it for the final demonstration design and not to put in risk the full demonstration fa\u00e7ade process considered. [WP9]\nThe system is able to balance heating and cooling needs by maintaining air chamber temperatures between 15\u00ba and 30 \u00ba (outdoor 5\u00ba- 40\u00ba).  The final total energy demand saving have been estimated between 25% in total consumption, divided 27% for heating and 40% for cooling. \nAdvanced Passive Solar Collector and Ventilation Unit [WP4]\n\nThe main objective of this work package has been the Development of the Advanced Passive Solar Collector and Ventilation Unit to best improve the annual energy performance of the buildings to be retrofitted, balancing heating and cooling requirements. This will provide a multifunctional bioclimatic technological unit to improve thermal performance in building fa\u00e7ade refurbishment. The different steps have been considered to achieve the main goal, the conceptual design, thermal simulation, early prototype constructions and testing, the unit installation and energy refinement, and finally the manufacturing process and costs definition.\n\nThe first part of the work, as defined in the tasks, has been related to the detailed definition of the technological unit conceptual design. This work can mainly be summarised in the next 3 pictures.\n\nIn the above Figures it can be seen the different configurations that the system can use depending on the external conditions (Winter or Summer).  These configurations can be obtained using the different positions that the roller of the system could reach. With the movement of the rollers the system could work as a ventilated fa\u00e7ade (mainly in summer conditions), as a parietodynamic wall (heating the interior space with external air) or as a trombe wall (heating the interior space air that flows across the unit chamber). All these possibilities contribute to the final behaviour of the unit. One of the improvements that this unit has is that all the elements are controlled by an algorithm developed in the project. This algorithm is in charge of opening and closing the different active elements that the unit has depending on the internal conditions (the unit is connected with a sensor to the interior of the building), the external conditions (there is another connection with a weather station) and the internal conditions of the unit chamber (the one inside the unit itself which is in direct contact with the PCM to heat the air and the fans to allow a better flow). The algorithm and the different components are controlled by a computer installed in the unit which also has connection with the general control of the fa\u00e7ade. These two computers manage the entire system of the unit.\nTo verify this information and the incidence that the system can have in the heating and cooling conditions of a specific space, they several simulations (passive and dynamic) have been done and additionally the system has been prototyped and installed in the KUBIK building of Tecnalia to measure the real behaviour (view Picture 1 and Picture 2) of an initial prototype.\n\nThe unit has been measured for 6 months. With the data obtained during this real test they have been provided results for different climates (South Europe as Sevilla and Madrid and North Europe as Paris and Berlin). Analysing these results it can be seen (view an example of the results for Madrid in Figure 17 and Figure 18) that the unit has a good result related to the heating energy output (around 25%-30% in all the climates analysed) but the behaviour related to the cooling energy output is not representative (in all the climates analysed). Some changes can be done in the characteristics of the PCMs of the chamber but the results do not look very promising. The good result is related to the heating possibilities of the system in all the climates.\n\nOne of the next steps after the early prototype construction and validation in real conditions is to verify the system previous to the final design. A structural verification was conducted under simulations of the different components of the technological unit, to have more data before producing the final prototypes.\nThe final objective of the work-package tasks has been to install the unit in a demo building located in M\u00e9rida (Spain) to validate the performance in real conditions with real users. To make this installation it was necessary to verify that the characteristics of the unit comply with the different European standards and also with the legal construction requirements of the demo country. In WP7 of this project the entire analysis of the system has been conducted and in the next table are the results obtained by this specific technological unit. These results are higher than the minimum as defined by the Spanish Construction Code. Due to this and taking into account both results and requirements, it was established that the unit didn\u2019t have legal problems to be installed in the demo building in M\u00e9rida (Spain).\n\nOnce the testing validation was finished, with minor changes in the design (it was necessary to repeat some of the tests to confirm the new designs), the manufacturing of the samples that were going to be installed in the demo building began. The different components were collected during this process, some of them provided by the partners of the project (the profiles in aluminum and pvc, the insulation, some of the electronic components) and other ones were commercial products that were bought by Tecnalia.\n\nAfter receiving all the components, the process of manufacturing started in order to have the two units for the demo project built and checked. After the installation of the different components that form the sample, the mechanical components were tested connecting the unit to a computer with the control software. The rollers, the blind and the fans were tested in order to verify that everything works as expected. Once this verification was finished the units were sent to Merida to collect them in the final workshop and to make additional tests once the controller of the unit was installed.\nIn this last verification all the modes were tested that the sample can use to open and close the internal and external air ventilation elements, depending on the configuration of the rollers: connection between inside and outside of the unit, connection of the chamber with the outside and connection of the chamber with the inside. Apart from this it was tested again (after the transport), checking the operation of the algorithm simulating different conditions to see if the fans, rollers and blind reached their different positions without problems.\nAfter all these tests the units were installed in the demo building as it can be seen in the above pictures.\n \nFa\u00e7ade System Installations Design and Integration [WP5]\n\nDesigning the fa\u00e7ade system installations and integrating them with the existing fa\u00e7ade was a successfully overcome challenge. The main achievements on this part are described below.\n\nAt the beginning of the project a design methodology was elaborated, which allowed the identification of the essential information required to attain an optimised integrated solution related to the specific needs of the Technological Units to be designed and manufactured within the project.\n\nBased on the steps indicated by the previous methodology, different important tasks were successfully completed: (1) Identification and analysis of relevant functional and legal requirements for the installations needed by the Technological Units; (2) Development of different solutions for the integration of the service installations into the structural panel; (3) Analysis and selection of solutions for connection and connectors. Assessment of innovative solutions for future implementation and, (4) Elaboration of a design guideline to aid the creation of optimised wiring and piping layouts on each particular fa\u00e7ade.\n\nOnce all these activities were completed, a software application called IMET (Installation Material Estimation Tool) was developed to make initial estimates of the required installation components for buildings to be retrofitted with the MeeFS fa\u00e7ade system. It consists of an Excel VBA Tool that runs under a Graphical User Interface (GUI) created using the .NET framework. It has been designed as a standalone software, however, it is intended to be used in conjunction with the ERES software. Once the architect\/designer of the retrofitting project of the building has determined the TU layout of the fa\u00e7ade using ERES, he\/she will be able to roughly estimate all installation components that will be required for that configuration. The user can also save a summary of the results obtained in .PDF and .DOC.\n\nFinally, the last achievement consisted of the design and proposal of viable technical solutions for the integration of the different fa\u00e7ade distribution systems (electricity and water) with the existing building installations. The latter can be configured in many different ways and does not follow any identifiable pattern. Consequently, a general classification of these installations was performed and different solutions for connection with the existing building services were proposed, considering all specific technical and legal aspects of each particular problem. Finally, solutions for the demo building were also provided, together with the complete set of installation drawings, bills of materials and descriptions, necessary for the preparation of the demo project.\n \nFa\u00e7ade System Energy Management \u0026 Building Management [WP6]\n\nThe fa\u00e7ade Energy Management System (EMS) is a vital achievement of MeeFS project. This system may be compared to the nervous system of a human body, performing similar functions in MeeFS intelligent fa\u00e7ade structure, i.e.:\n\u2022\tsensing\/measuring the signals from the nearest surrounding of the fa\u00e7ade, and from the inside of fa\u00e7ade\u2019s structure itself,\n\u2022\tanalysing the current state of the fa\u00e7ade, by taking into account the fa\u00e7ade\u2019s current operating conditions, and computing the best set of actions for the fa\u00e7ade to make, in order to bring the fa\u00e7ade to the next, most desirable state,\n\u2022\tissuing the control signals to active TUs.\n\nThis system is easily adaptable to highly different configurations of possible application scenarios (different buildings, different climates and different operating conditions), because of its highly flexible design in terms of hardware and software structures. The flexibility of these structures has been attained by using simple and easily scalable solutions in both the hardware and software design cases, i.e.:\n\u2022\tthe hardware \u2013 consisting of fa\u00e7ade\u2019s CPU, an interconnected group of integrated drivers (called nodes) and sensors. Different roles of CPU and nodes may be implemented by using software modifications, and\/or by using hardware extension boards,\n\u2022\tsoftware \u2013 CPU has a linux based system running on it, allowing for writing custom fa\u00e7ade management programs, for example implementing services, like: fa\u00e7ade\u2019s algorithm evaluation, communication service for nodes, monitoring system management, external communication (useful for e.g. ESCO, surveillance, failure detection applications).\n\nThe range of possible configurations of EMS is very large. This feature is intentional, as it allows for the system to adapt to many different building retrofitting scenarios. In order to present one of the possible configurations of the system, and also to test its performance in the real case conditions, the particular version of the EMS has been designed and made for the case of the Demonstrator (Demo) building (located in Merida, Spain), and integrated with the MeeFS intelligent fa\u00e7ade structure. Following will be the short description of the Demo EMS.\n\nThe EMS of the Demo implements the control algorithm that controls the operation of the PSC\u0026V TUs, taking into account factors like: external ambient temperature and wind speed from the WS, internal temperature of the TU, temperature inside the corresponding dwelling, specific day of the year and time of the day, dwellers input. The EMS of the Demo is also responsible for performing monitoring data acquisition from the weather station.\n\nThe EMS is designed to operate fully autonomously, although it is possible to access it with internet via dedicated VPN connection.\n\nFor the node components special extension boards have also been developed, which were intended to be used with other types of TUs, however due to changes in the project, they have been not used in the final Demo EMS configuration. The following photographs indicate particular extension boards:\n\nComposite Structural Material and Manufacturing [WP7]\nThe research related to the innovative material and its manufacturing process has fulfilled major achievements in terms of innovative composite materials, production process and product standardisation. Among the main achievements, the 6 followings are outstanding:\n\n1. The Production of a thermoplastic pultruded profile with multi-orientation reinforcement fibre has been proven, at the same time the possibility to use the anionic pultrusion process to produce hollow section profiles reinforced by transversal fibres either from winding technique or from the use of fabrics. This opens a wide range of possible profile designs with outstanding mechanical properties.\n\n2. The Production of a large thermoplastic complex composite hollow cavities profiles has been carried out. During the course of the MeeFS project extensive trials have been carried out to identify the process parameters for the production of the main structural frame profile with multi-cavities. An impressive number of more than 800 bobbins have been used to form the pultruded shape.\n\n3. The novel prototype reactive thermoplastic pultrusion line has been studied and achieved. The production of the structural panel required the design and construction of a novel thermoplastic pultrusion prototype line including specific dosing unit adapted to the anionic pultrusion process. Design, assembling, testing and production were successfully carried out at CQFD.\n\nThe new reactive thermoplastic pultrusion process is powered by a powerful caterpillar machine specially designed for the production of such hollow cavity profile of about 5kg\/m. The pulling capacity is around 7Tons with force sensors and profile slipping detection. The multi-component resin system is injected under pressure via the dosing unit developed for pultrusion into a pultrusion die of the required profile shape.\n\n4. The special non-burning inorganic paint for thermoplastic composite profiles has been manufactured. This non-burning paint is based on geo-polymers which do not burn until 1000\u00b0C. With such a coating, the burning ability of the composite profile is reduced and the smoke emission is limited. CQFD has carried out trials to identify a formulation compatible with PA6 surface. \n\n5. Fast and easy assembling and mounting on site has been proven [WP9]. The complete fa\u00e7ade was assembling on site to minimise transport cost. The full operation took about one month, plus 2 weeks of fa\u00e7ade installation onto the building. Assembling and Mounting the MeeFS system turned out to be easy and without any majors troubles.\n6. Finally, successful complete standardisation of the novel MeeFS facade, one of the most crucial project milestone points, has been successfully performed. The main objective of this task is to define the legal requirements that apply to the new fa\u00e7ade developed by MeeFS project and to make the corresponding tests to be carried out on the fa\u00e7ade units to address the Spanish Requirements. To be able to make this characterisation it has been necessary to build specific prototypes. The final results have been used to define which technological units can be installed in the demo building in Merida. \nThe steps carried out in the document to define the requirements that need to be fulfilled by the system are the next ones:\n1.\tProduct definition: The MeeFS project is going to define a new type of fa\u00e7ade with some differences compared to the fa\u00e7ades that are at this moment in the market. In this point it is going to be described how we define the MeeFS fa\u00e7ades trying to find similarities to those defined in the fa\u00e7ades standards.\n2.\tTest according to product definition-ETAG 034: Once found one standard that could be used as a start point to define the characteristics of the MeeFS fa\u00e7ades, define which are the requirements that must be evaluated and the verification method.\n3.\tSpanish requirements and mandatory tests: to define those product characteristics that shall be determined according to national, regional or local regulation, taking into account the requirements established for Spain\n4.\tTest vs. technological modules: To define the units that must be tested and the tests per unit.\n\nTo define the product, the MeeFS system has been analysed taking into account its different components, the characteristics of these components and the definitions in the different standards. After this analysis it was obtained that there is a standard that almost covers the entire system. This standard is the ETAG 034 \u201cKits for external wall cladding\u201d. The conclusion after the analysis is that ETAG 034 should be used as a base for verification of the performance of MeeFS System because there is no other standards that cover better the system.\nThe tests according to product definition (ETAG 034) have been defined. The objective of this point is to check the contribution made by MeeFS System to the fulfilment of the seven Essential Requirements, as stated in the CPR for the construction works in which the product is installed.\n\u2022\tBasic Requirements for Construction Works (BWR): \no\tBWR1: Mechanical resistance and stability\no\tBWR2: Safety in case of fire\no\tBWR3: Hygiene, health and the environment\no\tBWR4: Safety and accessibility in use\no\tBWR5: Protection against noise\no\tBWR6: Energy economy and heat retention\no\tBWR7: Sustainable use of natural resources\no\tETAG also considers \u201cAspects of durability and serviceability\u201d\n\u2022\tINITIAL ASSUMPTION: MeeFS System is a ventilated cladding\n\u2022\tETAG 034 defines the test procedures to be applied. These tests are defined in deliverable D7.7\nThe Spanish requirement and mandatory tests have been defined, the Objective of this point of the document is to define those product characteristics that shall be determined according to national, regional or local regulation. In Spain the reference document is called C\u00f3digo T\u00e9cnico de la Edificaci\u00f3n, CTE. The Spanish Technical Building Code (CTE) is the normative framework that establishes the safety and habitability requirements of buildings set out in the Building Act (Ley Org\u00e1nica de la Edificaci\u00f3n, LOE). CTE is based on the concept of performance or objectives, in which objectives and the means of achieving them are clearly stated, without implying an obligation to use particular procedures or solutions. \nAccording to all above, the test for the Technological modules have been performed and the final results presented. In the next table shows the different tests performed to the MeeFS system per technological unit and the final results obtained by the system.\n\nAs can be seen in the table all the samples obtained a valid classification (green rows). The only unit that had problems during testing was the BIPV (photovoltaic unit). This technological unit didn\u2019t obtain the minimum classification under the fire reaction test (for Spain is a B-S3-D2). Due to this, the unit couldn\u2019t be installed in the demo building. In the table there are also grey rows. These rows were defined as not necessary for some of the tests (example: the solar protection didn\u2019t require the water tightness test because it is an open unit which always has a window on its back space (the window is the element that provides the water tightness).\n\nAll this information is explained in detail in D7.7 \u201cReport with the verification of performance of the system designed under European Standards\u201d. The main conclusion of the task T7.11 is that the system demonstrates the minimum characteristics to be installed in the demo building without legal problems. Some of the units demonstrated very high values in the different tests. These values can be used in the future as commercial arguments to sell the system with better possibilities.\n\nFa\u00e7ade System Guide of Design [WP8]\n\nThe Fa\u00e7ade system guide of design has been developed, in the framework of work package [WP8] in order to provide guidance and reference to retrofitting designers, and users of buildings; it is composed by three different entities: A Guide of Design, which establish the most adequate bioclimatic approaches for each climatic zone and considered building; the ERES software tool, which is a decision support Tool for designers that delivers the most adequate refurbishment configuration based on technical and economic considerations and; a Guide of Maintenance, to ensure the performance of the refurbished buildings during the service life of the refurbishment system, as well as its required maintenance.\nThe Guide of Design introduces the building designer to the proposed refurbishment modular system as well as its energetic performance. This guide covers constructive capabilities, thermal and energetic considerations, regulatory restrictions and the most suitable fa\u00e7ade configuration of a set of standard cases. The guide of design is a supporting tool for the MeeFS Facade designers: architects, structural \u0026 MEP engineers. It allows for optimal organising of construction process and the selection of the most appropriate Technological Units. The guide document is a multi-disciplinary explanation of the MeeFS Design process: the most important theoretical basis of MeeFS Fa\u00e7ade System.\n\nThe ERES software tool comes right after the design guide: it can recognise characteristic fa\u00e7ade elements thanks to its interoperability with third-party BIM software, and analyse the building surroundings. According to the climatic zone and to the intentions of the user, it provides optimal combinations of the MeeFS Technological Units, giving as a result the expected energy and economic savings, the estimated payback period, and a forecast of the investment needed for the whole retrofitting. \n\nAdditionally, the Guide of Maintenance for the fa\u00e7ade system takes advantage of two main databases: the knowledge of the construction process and the correct maintenance practices regime. The document is a summary of experience gathered during the construction of the Demonstration Fa\u00e7ade, and an overall set of rules for good maintenance practices in building management. It was also enriched with some proprietary information about advanced maintenance techniques required during handling of breakthrough technology prototypes. There is also a detailed section of the document covering legal actions and public hiring process that precede actual site works.\nThe guide provides a support to future MeeFS System users \u0026 customers: designers, building managers and owners. It is also the most comprehensive source of MeeFS data for execution teams.\nDemonstration of MeeFS Fa\u00e7ade System [WP9]\n\nThe main goal achieved during the whole project in the frame of the demonstration activities [WP9] was the full scale MeeFS prototype installation in the Pilot Building in M\u00e9rida (Spain). The final demonstration is a result of the process composed by different phases of the installation process, the most crucial ones being the technical design documentation preparation process, assembly activities in the workshop, and the real demonstration on-site.\n\nThe first steps were to carry out of a set of initial studies, in order to provide the best possible starting conditions in the demo site. Thus, a demo preparation management plan was developed, focused on the successful performance of the demo \u201cPilot Building\u201d, both in a technical but also social context.\nThe insight to the social environment of the Pilot Building provided the first tips on how to address the demonstration in a real scenario. Having collected information from the social workers staff from Junta de Extremadura, the decision to change from the initially selected demo building was taken, due to the possible social problems indicated which would be difficult to solve in the limited project execution time. The communication strategies were defined and the first contacts with the residents were established. Informative printed documentation was provided disseminating the retrofitting plans in the form of documentation (posters, flyer and mailing campaign), phone campaigns, meetings and door-to-door visits. Additionally, regular contact with the residents was necessary, to keep them informed about the Project. Studies of the consumption habits of the residents (billing information, surveys) were also conducted. In the context of the basic design and particular technical conditions to be considered, the information was compiled about the Pilot Building construction, installations and constructive details. Initial \u201cAs built\u201d documentation was obtained and analysed. Accurate drawings of the three fa\u00e7ades affected were elaborated from a topographic survey and readjusted with the on-site Laser Scan 3D (points cloud). Finally, the technical inspection was carried out, and the corresponding report of the current state described the construction pathologies detected outside and inside the apartments. The slabs identified for the installation of the new fa\u00e7ade elements were also initially tested, to define the maximum loads allowed.\n\nUsing the initial information gathered the modelling of the Pilot Building with Energy Software Tool was performed under the conditions extracted from all the information collected and results were presented. The energetic simulations were made with Design Builder (energy software tool). The modelling and the simulations of the Pilot Building were elaborated for both cases, the base case (Pilot Building at the initial state) and the MeeFS case (first draft of the Pilot Building retrofitting with MeeFS Fa\u00e7ade System). This way, a comparison of the results before and after the retrofitting was obtained. \n These results showed the great energy saving potential of MeeFS retrofitting solution in the building stock constructed before 2000.\n\nOn the basis of the ongoing progress of the Architectural and Structural Design and the Energetic concept of the system, the draft of the Fa\u00e7ade System Construction Project for the Pilot Building retrofitting and its economic analysis was elaborated.\nThe demo design was issued in the form of the Building Permit and Execution Project Design. The complete set of the drawings and descriptions were delivered, following the established strategy for their performance in the Spanish legal framework. The process on adaptation of the technical documentation to the Spanish regulations required the involvement of the local team of architects (GREENSTD) that worked in close collaboration with the partners directly involved in demonstration. The technical design documents (Execution Projects) were produced for the installation of the MeeFS System in the external East, South and West Fa\u00e7ades, but also the installation of the traditional ETICS System on the courtyard fa\u00e7ade to avoid the envelope thermal bridge effect and to allow the correct monitoring of the MeeFS fa\u00e7ade system in the dwellings affected.\nBased on the Spanish technical documents (Executio Projects), and in collaboration with the City Council, the Building Permit was obtained and the on-site activities started.\nThe assembly activities and storing of the construction materials have been taken at the workshop of the local company (EXTREPERSIANAS S.L). The MeeFS fa\u00e7ade structural panels, and integrated technological modules, were successfully assembled following the \u201cAssembly Guides\u201d prepared. Two training sessions were arranged on-site in M\u00e9rida, in a manner that the partners involved taught the local operators the procedures and details of each step of assembling the components of the system. The control of the materials was ensured by the corresponding register of delivery notes and shipping sheet, as well as the registration of all materials before exiting the workshop. In order to ensure the quality control of all activities of assembly, a control inspection sheet was filled for each multifunctional panel assembled.\n\nThe on-site activities started with the installation of the ETICS System on the Patio Fa\u00e7ade. This task was developed under the Construction Contract signed with the specialised company IMBAT\u00cdVEL E NOT\u00c1VEL, and it was finished in February 2016.\nHaving obtained the building licence, the public tendering was launched in order to the hiring process of the construction company (COEDYPRO). Following Spanish regulations, and after the certificate of commencement of work was signed, the on-site work started in September promoted by the owner of the building Consejer\u00eda de Salud y Pol\u00edticas Sociales (Junta de Extremadura) and parties involved COEDYPRO, Empresa Constructora S.L. as builder, GREENSTD as architects and engineers team in charge on Project and Site Management and ELABOREX in charge of the Quality Control inspection. All these companies have acted in the Project subcontracted by Consejer\u00eda de Salud y Pol\u00edticas Sociales (Junta de Extremadura). Following the calendar approved, the construction duration was 12 weeks, and completed in December 2016.\n\nThe preparation of an appropriate plan for the monitoring system, allowing monitoring of the building\u2019s energetic and comfort living related conditions for a certain period before and after installation of the MeeFS intelligent fa\u00e7ade, was a challenging, lengthy and absorbing process. There were several reasons for this fact, like: the overall complexity of the system (e.g. a vast amount of various types of signals\/sensors), the battery operated data acquisition system (greatly limiting the acquisition hardware capabilities), many changes of initial TU\u2019s distribution pattern in the monitoring system plan development phase (implicating many changes of the monitoring system design). However, eventually a well-suited design of the monitoring system has been developed, strictly addressing the specific Demo building monitoring needs. To see the system complexity, the following diagram may be presented, demonstrating the topology of the interconnections, sensors and acquisition nodes used in the system.\n\nThe physical implementation of the system has been mostly based on commercially available hardware equipment, like sensors and acquisition modules. However, some of this equipment had to be adapted in order to comply with the electronic and mechanical standards used within the monitoring system structure. Adaptation has been achieved by making additional pieces of customised PCBs and by providing the modified mechanical enclosures. The monitoring system, up to the moment of writing this document, has provided nearly 3 years of observation data. \n\nThe initial comparisons between the data before and after the retrofitting, even from such a short available period, show the sensible improvements in thermal resistivity of fa\u00e7ade and internal comfort level. The energy certification of the dwellings was made with the Spanish well recognised software tool CE3X. The modelling and simulation obtained between building cases before and after the renovation led to an increase in the building energy certification notes. The energy certification obtained must be considered as an approximation, due to the tool design limits, at least until the final monitoring results relocation and treatment. Under these initial simulation conditions, and in order to have an idea of the impact of the whole performance, the average data from each block was calculated. For the Energy Demand (saving around 15%) and Primary Energy Consumptions (saving around 36%), the improvements were so significant, since the MeeFS case was tuned to a better mark. For the CO2 Emissions, even that the mark did not change, the savings obtained were relevant, around 35%. \n\nIn the context of a social housing neighbourhood, the communication with the residents has been permanent since the beginning of the Project. The success of the demonstration was only possible in the context of good connection with the dwellers. Awareness raising activities were carried out, informing the residents about the Project, and involving them actively into the approach of energy efficiency renovation. The project faced different problems, related to the social issues and the public nature of the demonstration, being still on-going the part on recollecting of the monitoring data under the agreement made between the partners involved. \n\nExploitation \u0026 Dissemination [WP10]\n\nThe MeeFS project partners were actively involved in a number of Dissemination \u0026 Exploitation activities throughout the project, that are deeply described in continuation of the document. Communication material (flyer, posters, roll-up banner) has been regularly used by all partners and was distributed to stakeholders whenever possible. Dissemination material can be easily downloaded from the Project Website www.meefsretrofitting.eu. The website has been regularly updated and promoted by all partners. In addition, six scientific articles and ten journalistic articles were published. Consortium members have also been involved in networking activities, jointly attending over 100 events\/dissemination activities.\nBeyond the global fa\u00e7ade system, the MeeFS consortium has generated a whole set of results, some of them with a high potential for exploitation The exploitation strategy of each result was built with the consortium during five yearly exploitation workshops, and through bilateral exchanges. In the case of results with multiple ownership, \u201cexploitation leaders\u201d were designated. An Exploitation Plan for each key result was prepared and delivered. Two events, targeting different stakeholder communities, were also organised.\n\nPotential Impact:\nOnly 1 to 2% of the building stock is replaced annually in the EU (less than 1% in some countries) . Hence most of the energy savings required to meet the 2050 goals must come from existing buildings. According to IMPRO-building study, about 70% of the total building stock was constructed after 1945 and a majority of these buildings were constructed without consideration for energy efficiency criteria. \nThe targets to reach greater energy efficiency are residential buildings, which represent about 75% of the total building stock and 63% of final energy consumption in the building sector. The current retrofitting practices for residential buildings pose a variety of challenges to the construction sector, leaving considerable room for future performance improvement. Furthermore, today\u2019s measured rate of refurbishment (1.2%) is much lower than what is necessary to remain in line with Europe\u2019s 2050 ambitions. There is a need to accelerate the market uptake and large-scale implementation of energy efficient refurbishment solutions and increase the renovation level to 2-3% per year until 2030. This ambition is reflected in several European regulations and roadmaps, such as the Energy Performance of Building Directive, the Energy Efficiency Directive, the SET-Plan (Action 5) and the recent Energy Union Winter Package.\nThe building envelope (roof, fa\u00e7ade and basements) must be addressed as a priority in order to achieve proper levels of energy efficiency coming from the retrofitting of buildings. The fa\u00e7ade represents the largest part of the heat transmission surface and includes a number of critical components (like windows, balconies, ventilation units, etc.), while facing thermal bridge phenomena. However, most solutions available in the market only offer thermal insulation, have poor aesthetics and are rather uniform in terms of applicability to different typologies of buildings and to different fa\u00e7ade orientations. Climate and energy needs are also not properly considered.\nThis calls for the development of an energy efficient integrated and modular system that can be easily and quickly fitted to the fa\u00e7ade of any residential building in Europe: this is the challenge addressed by MeeFS retrofitting, which has developed, evaluated and demonstrated an innovative and integrated energy efficient multifunctional fa\u00e7ade system (decreasing the energy demand by more than 30%), modular and adaptable, geared towards the residential building sector.\n\nThe potential socio-economic impact includes the following points:\n-\tThe market uptake and roll-out of solutions such as the MeeFS system will contribute to reaching the 2020 and 2050 EU targets (i.e. by decreasing CO2 emissions and energy consumption of the residential building stock) \n-\tThe future commercialisation of MeeFS would also create specialised jobs, in particular for the pre-fabrication of the components and their pre-assembly. \n-\tAdditionally, the wide-scale deployment of pre-fabricated solutions such as MeeFS will contribute to reaching the expected performance when refurbishing buildings. The European building sector is indeed highly fragmented (with over 95% of SMEs) and not yet able to offer holistic solutions for deep renovation at acceptable cost and quality. Renovation processes are seen as costly, time-expensive, disruptive and risky by the consumers, and the measured performance is often below the expected one. Integrated pre-fabricated refurbishment solutions, which reduce the risk of poor installation and construction (and associated cumulative commissioning gaps) address this challenge and also pave the way to the deployment of energy performance based contracts, which are seen as one of the potential future business models which will allow consumers and the market to invest with confidence.\n\nMain dissemination activities \n\nTo raise awareness on the innovative solutions developed within the MeeFS project and facilitate their introduction onto the market, project partners have participated in a wide number of dissemination activities. Early on in the project, graphical material has been produced for the MeeFS project to ensure consistency and efficiency in communication activities. As part of this material, a visual and written identity has been developed for the project together with key messages on technology, energy and economic impact. In addition, a project leaflet has been created and updated to include the main project achievements. A poster and a roll-up banner have also been produced and used to promote the project at events, fairs and conferences.\n\nThis graphical material has been presented in a detailed Awareness and Dissemination Plan aiming to define the key messages, target audiences and main dissemination channels for the project. This Awareness and Dissemination Plan was used as guideline for all communication activities related to the MeeFS project and has been updated on a yearly basis. Each of the subsequent versions summarised the dissemination activities already carried out by project partners and presented an updated list of stakeholders that should be targeted within the project and the concrete plans and dissemination opportunities of the year ahead. \n\nThe first list of target audiences established at proposal stage has thus been enriched by partners throughout the whole project. The stakeholders mentioned in the following list have been identified as target audiences. This list gives examples of the specific stakeholders that have been targeted with dissemination activities, but it is nevertheless not exhaustive as project partners have been in contact with a wide range of audiences.\n\n\u2022\tEuropean Technology Platforms such as European Construction Technology Platform (ECTP) and other related platforms such as the PV platform, RHC (RES for Heating and Cooling), SUSCHEM.\n\u2022\tLocal Authorities \u0026 National\/Regional Public Bodies (like Municipalities) are key players as policy makers, favourable legislative framework creation, public procurements, owners and promoters of their own buildings.\n\u2022\tArchitects\u2019 Associations like ACE (Architects Council of Europe) need to be provided with appropriate tools for retrofitting.\n\u2022\tBuilding industry providers and installers through national, European and international associations related with the technologies developed in the project like EPIA (European Photovoltaic Industrial Association), ESTIF (European Solar Technology Industrial Federation).\n\u2022\tConstruction companies\u2019 associations should be aware of the new technologies that will be developed like ENCORD, FIEC and more.\n\u2022\tNational and regional Energy Agencies.\n\u2022\tPublic Promoters like CECODHAS (European Federation of Social Housing) and Private Promoters (European Real State Association) can offer to their clients the advantage of the developed systems.\n\u2022\tClients and users are key actors providing their perspectives in the formulation and assessment of the project results.\n\u2022\tRelated research community and citizens.\n\u2022\tStandardisation and Certification bodies\n\u2022\tThe European Commission, European Network of National Contact Points (NCPs) for NMP theme.\n\u2022\tInnovation Relay Centres (IRCs) network and other European market places, by offering technology transfer possibilities regarding MeeFS results for industries but specifically for SMEs.\n\u2022\tICT based stakeholders: Analysis and Design tool providers.\n\u2022\tDesigners, Engineers and consultants\n\nThese target audiences were addressed through different communication channels, defined at the beginning of the project. The dissemination channels were selected to reach out to a wide variety of audiences and comprised:\n\n\u2022\tA dedicated website presenting the objectives, partners and the activities of the project. \n\nThe website has been online since M3 and has been updated with 49 stories on activities and developments within the project. A series of ten articles and interviews written by professional journalists has also been published on the project website and hosted on the www.youris.com website, the youris.com media centre as well as on LinkedIn and on partners\u2019 websites. \nSince its launch, the MeeFS website had 23,823 visits, representing over 5,000 unique visitors. Web traffic particularly picked up in the final year of the project, thanks to communications efforts as results became available. As shown in the map below, the project website attracted visitors from around the globe. The darker the shade of blue, the more unique visitors from each country:\n\n\u2022\tSocial media presence.\n\nThe MeeFs project had a social media presence throughout the entire duration of the project. Twitter and LinkedIn have been selected as main social media channels to communicate about MeeFS innovative solutions. To reach a wider audience, consortium partners used their Twitter accounts to disseminate the information, jointly tweeting about MeeFs over 60 times.\n\n\u2022\tPublications in scientific literature and dedicated journals and reviews. \n\nPublications in at least 4 \u2018high impact\u2019 peer-reviewed international journals were planned in the first version of the Awareness and Dissemination plan to make the obtained results available to the scientific community. This target has been successfully achieved with 6 papers published in international academic journals. MeeFS partners published peer-reviewed articles in international journals such as the Journal of Sustainable Cities and Society, Journal of Energy Journal of Renewable Energy, Journal of Facade Design and Engineering or Fire Safety Journal. \n\nArticles were also submitted to conferences for presentation, including large, international industry conferences such as Congress on Architectural Envelopes, CISBAT Conference and the Conference on Advanced Building Skins, among others. \n\nIn addition, partners have produced a number of non-scientific articles about the project. Together, project partners have published a total of 44 papers\/articles. \n\n\u2022\tPresentations and participation at congresses, workshops, symposia conferences, exhibition fairs. \n\nThroughout the project, partners have presented the MeeFS project in over 10 international conferences or congresses such as the CISBAT conference, REHABEND or GENERA as well as during the EU Sustainable Energy Week and the World Sustainable Energy Days. Additionally, the project was represented in five trade fairs, including BATIMAT and SOLAREXPO. \n\nAt the end of the project, the MeeFS retrofitting system was showcased as an example of cutting-edge innovation during the 7th European Construction Technology Platform (ECTP) conference on 17-18 November 2017, attended by over 100 people in Brussels, Belgium. The MeeFS envelope system was presented by Magdalena Rozanska from Acciona during the conference session on \u0027New technical solutions to accelerate the renovation of Europe\u0027s building stock\u0027. In addition, MeeFS had its own exhibition stand, manned by Greenovate! Europe, enabling face-to-face interaction with conference attendees from across the construction industry. The conference was an ideal opportunity to explain the advantages and future potential of the MeeFS facade and discuss the possibilities for commercialisation or further development with a wide group of stakeholders. \n\nIn total, project partners took part in over 100 events to disseminate information about the MeeFS project. Through these events, a wide range of audiences covering building industry representatives, researchers, entrepreneurs, students, investors and policy-makers were reached.\n\n\u2022\tProject events\n\nTo reach the dissemination objectives of MeeFs, two stakeholder workshops were organised with the aim to involve professional stakeholders to enhance their awareness about the project and the novel technologies which are being developed as a part of it, spread best practices, and foster networking opportunities. \nThe first MeeFS stakeholder workshop, entitled \u201cPre-fabricated facades \u2013 niche forever or mass market soon?\u201d took place 2 November 2015 in Vienna, Austria. The workshop, hosted by the University of Natural Resources and Life Sciences (BOKU) of Vienna, and organised in partnership with the EU-GUGLE project, brought together professional stakeholders from the construction and energy sectors to discuss the actual deployment pre-fabricated facades based on the experiences of the two projects. The event allowed for exchange of views on the proposed innovative technologies, and facilitated networking opportunities and synergies with potential early adopters and users throughout Europe.\n\nThe second stakeholder workshop was combined with the project\u0027s final mini-conference and networking reception on 16 November 2016 in Brussels, Belgium. Nearly 30 stakeholders from the construction and energy sectors as well as regulators, researchers and policy-makers attended the event to learn about the technology developed, lessons learned from the MeeFS project and discuss how to bring multifunctional pre-fabricated facades closer to the market. The interactive format of event allowed for an exchange of views on the proposed innovative technologies, and facilitated networking between the attendees. \n\n\u2022\tNetworking activities\n\nDifferent types of networking activities were conducted, mainly focusing on establishing networks with existing networks or projects. Active links were established with construction and energy related European platforms such as ECTP, SmartGrid, PVTP, ESTP, E2BA and more. \n\nAlso, the EC supported FP7 project NEWBEE was approached to create active links with them and find areas of collaboration. Both NEWBEE and MeeFS have in common the development of business models which will support the expansion of high performance construction processes resulting in sustainable buildings, both new and renovated. In addition, cooperation was established with the EU-GUGLE project in the framework of the first stakeholder workshop. \n\n\u2022\tAudiovisual material.\n\nG!E\/iCons developed and released a project video  (https:\/\/www.youtube.com\/watch?v=5agtliQqYlA\u0026feature=youtu.be) , which introduced the project, its main objectives and achievements, as well as energetic, environmental and industrial features of the MeeFS technology. \nThe video production was coupled with a tailored distribution methodology. It has been published on the project website, promoted on the partners\u2019 website, Greenovate! Europe Twitter accounts and Greenovate! Europe YouTube Channel.\n\nThe joint efforts of WP10 Leader Greenovate! Europe and project partners helped the MeeFS project reach a worldwide audience through the whole duration of the project. Selected target audiences have thus been informed about the MeeFS system through different communication channels, opening the way for further exploitation of the project results.\n\nExploitation results\n\nMeeFS Retrofitting has developed, evaluated and demonstrated an innovative energy efficient multifunctional fa\u00e7ade system, modular and adaptable, geared towards the retrofitting of residential building, but also applicable to the non-residential sector and for new constructions.\nBeyond the global fa\u00e7ade system, MeeFS consortium has generated a whole set of results outlined below. Some of them have a high potential for exploitation:\n\n- KEY RESULT 1, The whole retrofitting process using MeeFS technologies, All partners cited below\n- KEY RESULT 2, A structural frame made of a thermoplastic composite material, CQFD, AST, Acciona\n- KEY RESULT 3, A new industrialised pultrusion process for cost-effective manufacturing of the structural components, CQFD\n- KEY RESULT 4, An Advanced Passive Solar Protector and Energy Absorption Unit, Acciona\n- KEY RESULT 5, An Advanced Passive Solar Collector and Ventilation Unit, Tecnalia\n- included in RESULT 1, A structural module, compatible with the structural frame, Acciona, AST\n- Included in RESULT 1, ERES (software for design strategies), including: The selection method to choose the optimal layout of Technological Units depending on the building location and orientation, Payback calculation, Antworks, TBC, Technion, NTUA, Fraunhofer\n- Included in RESULT 1, IMET (Installation Material Estimation Tool), AST, VTT and Acciona\n- Included in RESULT 1, Building Energy Management System, including Control and monitoring system for the active technologies, SKA Polska\n- Included in RESULT 1, Web based remote monitoring tool, displaying the data from the BEMS, VTT\n\nAt the beginning of MeeFS, most of these results were at TRL  2 (technology concept formulated), except for result 5 (TRL 3 \u2013 experimental proof of concept) and result 3 (MRL  3 \u2013 proof of concept validation). Thanks to the project and its full scale demonstration, most of the results reached a TRL 7 \/ MRL 8, as illustrated below. \nLessons learnt from the project and the demonstration\nThe demonstration on a residential building in Merida, Spain, has been very ambitious from the early beginning. It was a unique opportunity to test the construction processes developed in MeeFS, to measure the real-life performance of the various components of the multifunctional fa\u00e7ade, and to capture important lessons learnt. It was also a strong constraint for the R\u0026D phase, since the prototypes development had to quickly reach a TRL 7, with little time for iterations: this meant that risks related to R\u0026D had to be carefully addressed and minimised, but which limited the potential for design optimisation.\n\nThe main lessons learnt are summarised as following:\n- A multifunctional fa\u00e7ade system with a multi-module technology and standard modules dimensions, Because of the pre-defined dimensions of the modules and panel, the system is in practice difficult to replicate in all EU buildings, as each building has its specific dimensions, Flexible design, adaptability to various climate condition and facade orientation thanks to the different available modules, Potential for improvement is to make the system more flexible in terms of dimensions\n- Integration of innovative solutions, including lightweight materials (composites), The costs required to test the system and obtain a Technical Agreement (compulsory for the demo) are very high. New tests may have to be carried out to demonstrate or commercialise in other EU countries, The composite panel and innovative technologies successfully passed the tests, Potential for improvement is to optimise the design of the structural profiles and module boxes to make the most of the lightweight and insulating properties of the composites.\n- Manufacturing with easy industrialisation, The sourcing of some of the innovative materials (i.e. PCM) is challenging. Prototype costs are very high since involving a lot of manual operations (e.g. drilling, painting, coating), Successful manufacturing of composites via pre-industrial production line, Industrialise the manufacturing process for the composites panels. Potential for improvement is to develop key partnerships to secure the manufacturing of the other units.\n\n- Off-site assembly, The assembly requires for the time being additional manual operations (e.g. screwing)\nThe site for the assembly and storage of the different components had to be carefully selected (e.g. to reduce transportation costs), Easy assembly of the panels thanks to the clear guidelines, Secured transportation with the dedicated lifting beam, Potential for improvement is to optimise the design of the structural profiles and module boxes to facilitate the assembly\n\n- Fast installation with reduced on-site works,  Difficulties to find a contractor willing to take the risk to install an innovative solution, Very easy to install on site, Develop key partnership with interested construction companies and provide training to reach the required skills\nSynthesis of exploitation plans for project results\nThe exploitation strategy for each result was built with the consortium during five yearly exploitation workshops and through bilateral exchanges. In the case of results with multiple ownership, \u201cexploitation leaders\u201d were designated.\n\nA major challenge has to be overcome by the partners to exploit the MeeFS system: manufacturing. Apart from the manufacturing by CQFD of the pultruded profiles for the composite panel, no partner has the in-house capacity to manufacture the other technologies. Key partnerships with manufacturers therefore have to be developed. This also means that the industrialisation process (investment required, planning, time to reach first sales, break even, etc.) is not under the sole responsibility of the consortium. Preliminary Business Plans were nevertheless proposed. Although confidential, the main conclusions are presented below:\n\n- The whole retrofitting process using MeeFS technologies, Exploitation leader ACCIONA, co-owners AST\/ CQFD\/ TECNALIA\/ Antworks\/ Technion\/ NTUA\/ Fraunhofer\/ VTT\/ SKA Polska, Exploitation route Trademark licensing, Further research or investment required like optimisation of design to maximise the benefits of composites Industrialisation to reduce costs, Certification \/ standardization\n- A structural frame made of a thermoplastic composite material, Exploitation leader AST, co-owners CQFD\/ ACCIONA, Commercialisation by CQFD with Acciona and AST, Further research or investment required like optimisation of design to maximise the benefits of composites, Development of new coating, Certification\n- A new industrialised pultrusion process for cost-effective manufacturing of the structural components, Exploitation leader CQFD, Direct use by CQFD , Exploitation route Direct use by CQFD  , Further research or investment required like development of an industrial production line to reduce production cost\n- An Advanced Passive Solar Protector and Energy Absorption Unit, Exploitation leader ACCIONA, To be determined when the manufacturing potential is secured Exploitation route, Further research or investment required like optimisation of design and sourcing of PCM to reduce cost\n- An Advanced Passive Solar Collector and Ventilation Unit, Exploitation leader TECNALIA, Exploitation route Licensing by Tecnalia (under patent EP2520870 A1)\n\nBeing technologically innovative is not enough, innovative business models need to be developed. New business models and financial mechanisms have to be put in place to make building retrofitting processes more and more affordable. This applies in particular to the retrofitting of facades for which the upfront investment is high. \n\nBusiness models that cover the whole value chain (to achieve the targeted refurbishment performances) were reviewed. In particular, the adaptation of the ESCO approach to the residential sector was investigated as a potential route to commercialise the MeeFS system. \n\nThese business models and the potential for the future exploitation of the MeeFS system were presented and discussed during two stakeholder workshops organised in Vienna, 2015, and Brussels, 2016. These events allowed an exchange of views on the proposed innovative technologies, and provided networking opportunities and synergies with potential early adopters and users throughout Europe.\n\nList of Websites:\nwww.meefs-retrofitting.eu\n\nAll project contacts, its logo, diagrams, reports and photographs on progress, as well as the official project video may be found directly at the web page indicated above.","sourceUpdateDate":"2017-05-10 11:02:43","contentCreationDate":"2017-05-10 10:59:50","contentUpdateDate":"2017-05-10 11:02:35","lastUpdateDate":"2017-05-10 11:02:47","archivedDate":"2024-06-23 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"pubsum","title":"Report Summary","description":"Result: Publishable summary (FP7 SESAM) and Summary for publication (H2020 SyGMa)","displayCode":"\/Report Summary","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"sesam","title":"SESAM","description":"RTD FP7 reporting system (including FP6 Marie Curie)","displayCode":"\/SESAM","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"3106603","legalName":"ACCIONA INFRAESTRUCTURAS S.A.","address":{"country":"ES"},"contenttype":"organization","attributes":{"source":"sesam","type":"relatedOrganization"}},{"availableLanguages":"en","rcn":"102074","id":"285411","acronym":"MEEFS RETROFITTING","title":"Multifunctional Energy Efficient Fa\u00e7ade System for Building Retrofitting","archivedDate":"2024-06-18 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/67\/11936537\/91827000","title":"climatic change mitigation","displayCode":"\/engineering and technology\/environmental engineering\/ecosystem-based management\/climatic change mitigation","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/63\/387","title":"composites","displayCode":"\/engineering and technology\/materials engineering\/composites","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/53\/369","title":"polymer sciences","displayCode":"\/natural sciences\/chemical sciences\/polymer sciences","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"CP-IP","title":"Large-scale integrating project","displayCode":"\/Large-scale integrating project","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"de,en,es,fr,it,pl","rcn":"854","id":"FP7-NMP","code":"FP7-NMP","frameworkProgramme":"FP7","pga":"FP7-NMP","title":"Specific Programme \u0022Cooperation\u0022: Nanosciences, Nanotechnologies, Materials and new Production Technologies","shortTitle":"Nanosciences, nanotechnologies, materials and new production technologies","parent":{"rcn":"846\/1401\/837","code":"FP7-COOPERATION\/EC\/FP7"},"archivedDate":"2024-06-12 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"legalbasis","title":"Legal Basis","description":"Programme: Legal basis for research funding","displayCode":"\/Legal Basis","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedLegalBasis"}},{"availableLanguages":"en","rcn":"17069","id":"FP7_EeB.NMP.2011-3","code":"EeB.NMP.2011-3","frameworkProgramme":"FP7","title":"Energy saving technologies for buildings envelope retrofitting","parent":{"rcn":"17048\/17049\/13178\/19513\/854\/846\/1401\/837","code":"NMP-5.2.1\/NMP-5.2\/NMP-5\/NMP\/FP7-NMP\/FP7-COOPERATION\/EC\/FP7"},"archivedDate":"2024-06-14 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"topic","title":"Topic","description":"Programme: Part of the Commission work programme implementing legal basis","displayCode":"\/Topic","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedTopic"}}]},"contenttype":"project","attributes":{"source":"sesam","type":"relatedProject"}},{"language":"en","availableLanguages":"en,any","uri":"\/docs\/results\/285\/285411\/final1-meefs-pr-m60-final-r-20161231-released.pdf","mimetype":"application\/pdf","size":"0","contenttype":"webItem","attributes":{"source":"sesam","type":"relatedResultAttachment"}}],"regions":[{"name":"Spain","rcn":"242387496","nutsCode":"ES","euCode":"ES","isoCode":"ES","attributes":{"source":"sesam","type":"relatedRegion"}}]},"modelVersion":"132","icaVersion":"20.0.0-48f81e07"}