{"contenttype":"result","language":"en","availableLanguages":"en","rcn":"203583","id":"680169_PS","title":"Periodic Reporting for period 2 - SUSPIRE (Sustainable Production of Industrial Recovered Energy using energy dissipative and storage technologies)","teaser":"This project has focused its activity  on residual heat streams that can be classified by their physical condition: liquid, solid or gas and by the temperature range that they have. This project has identified investment casting manufacturing process with its corresponding...","description":"periodic","summary":"This project has focused its activity  on residual heat streams that can be classified by their physical condition: liquid, solid or gas and by the temperature range that they have. This project has identified investment casting manufacturing process with its corresponding residual heat streams as representative of a significant number of energy intensive industries such as steel, glass, cement, food industry. Identified residual heat streams are basically:\n\u2022\tHigh temperature exhaust gases from combustion furnaces that are generated in a continuous way. Exhaust gases get out from the furnace at around 800\u00baC.\n\u2022\tSteam getting out of the boilerclave at around 100\u00baC and that is discontinuously generated.\n\u2022\tCooling water from different equipments such as: Wax injection units, compressors, induction furnaces.\n\nDifferent technical solutions have been identified in this project :\n\u2022\tInnovative High Temperature Heat Exchanger (HTHE) for energy recovery from combustion gases allows recover heat directly from high temperature source up to 800 \u00b0C. The design of the HTHE is based on innovative so called \u201cpillow-plate\u201d heat exchanger. This solution allows to ensure even thermal contact between hot chimney wall and heat transfer fluid (Syltherm 800 is used). Also channels of pillow-plate type heat exchanger distribute the HTF evenly through heat transfer area. Internal geometry of HTHE is design to ensure a large heat transfer area and minimize pressure drop of exhaust gases without affecting furnace operation.\n\u2022\tInnovative design of High Temperature Heat Exchanger with integrated inorganic PCMs heat accumulator (HTHE PCM) allows the heat exchanger to operate in charging or discharging and direct heat transfer (between two fluids in two independent loops) modes simultaneously when the consumption and supply modes do not match and\/or the heat transfer rate of charging and discharging differs. Inorganic PCM (H190) store heat at constant temperature up to 350 \u00b0C.\n\u2022\tInnovative design of Low Temperature Heat Exchanger with integrated organic PCMs heat accumulator (LTHE) allows achieving a high heat recovery and storage rate \u2013 high quantity of heat in a brief period of time can be recovered and stored. The system consists of two independent loops connected by copper plates (fins). The heat exchanger can operate in charging or discharging and direct heat transfer modes simultaneously when the consumption and supply modes do not match and\/or the heat transfer rate of charging and discharging differs. Organic PCM (RT82) store heat at constant temperature up to 100 \u00b0C. \n\u2022\tA BTES system has been developed placing a total quantity of 30 bores of 150 meters depth for heat interchange with the ground and taking advantage of the storage capacity. This system gathers the energy of the High Temperature circuit onde its temperature is lower than 50\u00baC to be used all the remaining energy in cascade. The system is supported in a heat pump that supplied heat or cold depeinging on the needs but always considering the differential temperature achieved in the ground.\n\u2022\tThe process main data variables are  controlled by a smart data management system that will achieve the best energy recovery yield maintaining or improving the manufacturing and quality ratios \n\nThese technical development have led to following industrial results:\n-\tThe total energy recovery rate has been 8022 MWh\/y of primary energy. We have to rest associated consumptions of the energy recovery system (pumps and heat pump) 1890 MWh\/h. Net savings are 6131 MWh\/year that supposes an energy reduction consumption of a 15,9% of the total plant consumption. The recovery rate was initially forecasted with a lower energy consumption of the plan (4222 MW\/h\/y), now the quantity has increased but the percentage is lower.\n-\tLCA mainly as CO2 emissions reduction has been calculated representing a 22% reduction.\n-\tA signature with PCB has been made agreeing the terms of commercialization of the excess of energy with TELUR and the town council will launch a tender for energy supply to the sports center in brief.\n-\tThe energy consumption of natural gas of the sport centre is aroung 3 GWh\/y, and the forecasted supply of energy with the final results obtained is 1539 MWh\/y in thermal energy, and 2012 MWh hvc \/y in natural gas, so the saving for the sport centre is:3000 \u2013 1539 = 1461 MWh hvc\/y (49%)","workPerformed":"This project report includes all the project period from the beginning to its closure after 48 month running.\nDuring this working period corresponding to the 48 months WP1, WP2, WP3, WP4, WP5, WP6 and WP7 have been finished and final results from performed activities are as follows:\n\n\u2022\tR1 - A group of new heat exchanger equipment (2 prototypes): one for high temperature heat exchange and another for low temperature heat exchange will be developed.\n\u2022\tR2 - A Borehole Thermal Energy storage unit (BTES) with two different levels of heat storage will be developed \n\u2022\tR3 \u2013 Expert knowledge on PCM selection, integration and use including equipments construction and safety measures\n\u2022\tR4 \u2013 Expert knowledge on Heat Transfer Fluid for high energy recovery exhaust gases (800\u00baC) selection, integration and use including equipments  construction and safety measures.\n\u2022\tR5 - Smart Management System, with an adapted methodology for process monitoring and control, to be integrated in the ISO 9100 of the plant.\n\u2022\tR6 \u2013 Energy savings due to running energy recovery system\n\u2022\tR7 \u2013 Industrial system for energy recovery.\n\nThe dissemination has taken place over different congresses and fairs \tStatusPrediction of lifetime of critical components for energy efficient installations \/Tribology International\/Lubmat (C) 2016\/International Conference \u201cEnvironmental Engineering\u201d, Vilnius, 28 April 2017\/ Geoner 2017 V Congreso de energ\u00eda geot\u00e9rmica aplicado a la edificaci\u00f3n y a la industria , Madrid, 26 Abril 2017, Energy day Durango 2018, GIFA D\u00fcsseldorf 2019","finalResults":"Actual plants have several handicaps to integrate this type of systems as in their lay out energy recovery of industrial heat streams has not been an objective. This project aims to be a reference to systematically integrate the products, equipments and smart control systems that will be developed in an industrial plant with intensive energy consumption. A future challenge could be to apply the technology and methodology developed as part of the manufacturing process.\nThe contract signed off with third parties assure a symbiosis between industry and society and support the sustainable development of process industry in the surrounding areas. \nHeat exchangers with a high accumulation capacity rate can be extrapolated to other segment niches as exhaust gases in the transport area where energy can be stored and further used in for fuel preheating or transferred for external applications. \nIndustry with less intensive energy consumption, but with local generation of this residual heat streams, can also take advantage of these new technologies due to be more affordable by their development in the market. The PCM resulting from this project will open the window for new business by formulating and commercializing these products.\nSusPIRE project has developed a smart data management system that will define the best actuation protocols at any time for a given process to reduce rejection rate as an additional residual heat stream.","periodNumber":"2","periodFrom":"2017-04-01","periodTo":"2019-09-30","reportTypeDescription":"Periodic Reporting for period 2","identifiers":{"reportId":"197121"},"sourceUpdateDate":"2024-02-24 10:47:00","contentCreationDate":"2017-10-09 18:04:23","contentUpdateDate":"2024-11-06 10:16:22","lastUpdateDate":"2025-10-08 19:21:30","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"pubsum","title":"Report Summary","description":"Result: Publishable summary (FP7 SESAM) and Summary for publication (H2020 SyGMa)","displayCode":"\/Report Summary","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"198357","id":"680169","acronym":"SUSPIRE","title":"Sustainable Production of Industrial Recovered Energy using energy dissipative and storage technologies","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/29\/91\/521\/1303","title":"sustainable economy","displayCode":"\/social sciences\/economics and business\/economics\/sustainable economy","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/47\/307","title":"software","displayCode":"\/natural sciences\/computer and information sciences\/software","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/67\/425\/1169","title":"renewable energy","displayCode":"\/engineering and technology\/environmental engineering\/energy and fuels\/renewable energy","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/49\/321\/30027\/1003","title":"biological interactions","displayCode":"\/natural sciences\/biological sciences\/biological behavioural sciences\/ethology\/biological interactions","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"RIA","title":"Research and Innovation action","description":"Research and Innovation action","displayCode":"\/Research and Innovation action","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"de,en,es,fr,it,pl","rcn":"664321","id":"H2020-EU.3.3.","code":"H2020-EU.3.3.","frameworkProgramme":"H2020","pga":"H2020-EU.3.3.","title":"SOCIETAL CHALLENGES - Secure, clean and efficient energy","shortTitle":"Energy","parent":{"rcn":"664235\/664087\/664086","code":"H2020-EU.3.\/H2020-EC\/H2020"},"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"legalbasis","title":"Legal Basis","description":"Programme: Legal basis for research funding","displayCode":"\/Legal Basis","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedLegalBasis","uniqueProgrammePart":"true"}},{"availableLanguages":"de,en,es,fr,it,pl","rcn":"664323","id":"H2020-EU.3.3.1.","code":"H2020-EU.3.3.1.","frameworkProgramme":"H2020","pga":"H2020-EU.3.3.1.","title":"Reducing energy consumption and carbon foorpint by smart and sustainable use","shortTitle":"Reducing energy consumption and carbon footprint","parent":{"rcn":"664321\/664235\/664087\/664086","code":"H2020-EU.3.3.\/H2020-EU.3.\/H2020-EC\/H2020"},"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"legalbasis","title":"Legal Basis","description":"Programme: Legal basis for research funding","displayCode":"\/Legal Basis","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedLegalBasis"}},{"availableLanguages":"en","rcn":"664710","id":"H2020_EE-18-2015","code":"EE-18-2015","frameworkProgramme":"H2020","title":"New technologies for utilization of heat recovery in large industrial systems, considering the whole energy cycle from heat production to transformation, delivery and end use","parent":{"rcn":"20200","code":"H2020-Topics"},"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"topic","title":"Topic","description":"Programme: Part of the Commission work programme implementing legal basis","displayCode":"\/Topic","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}},{"language":"en","availableLanguages":"en","code":"31049247","title":"Industrial processes","displayCode":"\/Industrial processes","attributes":{"classification":"topicKeyword","type":"isAbout"}},{"language":"en","availableLanguages":"en","code":"31049263","title":"Energy end-use efficiency and energy services","displayCode":"\/Energy end-use efficiency and energy services","attributes":{"classification":"topicKeyword","type":"isAbout"}},{"language":"en","availableLanguages":"en","code":"31049287","title":"Combined Heat \u0026 Power","displayCode":"\/Combined Heat \u0026 Power","attributes":{"classification":"topicKeyword","type":"isAbout"}},{"language":"en","availableLanguages":"en","code":"31049241","title":"Energy efficient industry","displayCode":"\/Energy efficient industry","attributes":{"classification":"topicKeyword","type":"isAbout"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedTopic"}}]},"contenttype":"project","attributes":{"source":"corda","type":"relatedProject"}},{"language":"en","availableLanguages":"en,any","uri":"\/docs\/results\/h2020\/680\/680169_PS\/description-of-recovery-system.png","alternativeText":"Scheme of energy recovery system","mimetype":"image\/png","size":"122880","contenttype":"webItem","attributes":{"source":"corda","type":"relatedResultAttachment"}},{"language":"en","availableLanguages":"en","defaultLanguage":"en","id":"4da5f22b5c44a61d4f969f727498997a","archivedDate":"2025-06-20 00:00:00","physUrl":"http:\/\/suspire-h2020.eu","status":"invalid","contenttype":"webLink","attributes":{"represents":"project","source":"corda","type":"relatedWebsite"}}]},"modelVersion":"132","icaVersion":"20.0.0-48f81e07"}