{"contenttype":"result","language":"en","availableLanguages":"en","rcn":"228450","id":"737757_PS","title":"Periodic Reporting for period 2 - Q-Air (Sustainable Prefabricated Glass Fa\u00e7ade with Performance Exceeding State-of-the-art Glass Fa\u00e7ades)","teaser":"Modern society is continually searching for technical and organizational innovations that lower energy consumption, thus contributing to lower energy demands, reduced greenhouse gas emissions and mitigate dependence on imported energy. Providing high quality living and working...","description":"periodic","summary":"Modern society is continually searching for technical and organizational innovations that lower energy consumption, thus contributing to lower energy demands, reduced greenhouse gas emissions and mitigate dependence on imported energy. Providing high quality living and working conditions in buildings, which improves people\u2019s health, wellbeing and productivity is an energy intensive process. Buildings within the EU are responsible for 40% of energy consumption and 36% of CO2 emissions. The building envelope is one of the most promising elements that can completely recast demands for cooling and heating loads. On the other hand, the building envelope plays a major role in the daylight factor, the occupant\u2019s experience and on energy demand attributable to artificial lighting.\n\nQ-Air project is about an innovative glazing envelope that can reach even nZEB (nearly Zero Energy Building) requirements with thermal insulation Ucw value down to 0.30 W\/m2K for 100% transparent facade. Q-Air fa\u00e7ade system uses an innovative, multi-chamber insulating core, which delivers superior energy efficiency, maximised natural daylight and the highest living and working comfort with 24-hour views to the outdoor environment without external sun shading.\n\nThe objectives of the Q-Air project were to technically upgrade the Q-Air fa\u00e7ade system with regard to sealing and structural performance, develop Q-Air large-size glass elements, develop additional cover material application, develop Q-Air special fa\u00e7ade system for building refurbishment and develop Building Information Modelling (BIM) libraries. Further objectives were to analyse, test and certify developed system in mechanical, thermal and sustainable sense. General objective was also to intensively disseminate project results to stakeholders for effective market take-up. All the objectives of the Q-Air project are met, and activities successfully realized. \n\nThe outcome of this project offers a complete Q-Air fa\u00e7ade system for clients searching for a glazed building envelope, either for new builds or refurbishments, which ensures much lower energy consumption for heating, cooling and lighting, reduced greenhouse gas emissions, mitigate dependence on imported energy whilst also delivering much better working and living conditions for occupants inside the buildings. Together with advanced Q-Air BIM design, fast and simple installation principles, and low maintenance through building\u2019s life-time, Q-Air responds perfectly to architectural, construction, owners and occupants needs. Q-Air is available for wide market usage and thus moving the industry closer to a cost-effective and human-friendly, nearly zero energy buildings.","workPerformed":"\u0022Project Q-Air commenced January 1st, 2017 and concluded on December 31st, 2018. During the project implementation, the following results were achieved: \n-\tNew aluminium and steel structural profiles with higher load capacity and lower thermal transmittance,\n-\tUniform sealing system for all types of structural profiles (aluminium, steel and polyamide),\n-\tQ-Air large size fa\u00e7ade element with dimensions up to 6 x 3 m (height x width),\n-\tSolution to apply cover material such as metal sheet, wood or stone on Q-Air element,\n-\tQ-Air fa\u00e7ade refurbishment solutions such as stick built fa\u00e7ade, fixed window refurbishment and modular fa\u00e7ade,\n-\tUpgraded production line with shorter production cycle,\n-\t\u0022\u0022Knowledge center\u0022\u0022 with made detailed technical documentation,\n-\tQ-Air tested and certified for mechanical and thermal properties, air- and water-tightness, fire resistance and sound reduction,\n-\tNumerically determined Q-Air\u0027s characteristics,\n-\tQ-Air BIM library (Building Information Modelling), \n-\tGuidelines for further BIM process integration into industry sector,\n-\tInteractive tool \u0022\u0022Q-Air Point\u0022\u0022 for demonstration of new glazed building envelope Q-Air and its many benefits,\n-\tCalculated environmental impact and issued EPD (Environmental Product Declaration),\n-\tQ-Air\u0027s impact on the sustainability of building determined,\n-\tImproved working and living comfort proven, \n-\tIntellectual property rights were geographically defined,\n-\tIntensive dissemination of project results to stakeholders on international public, science, other events and activities for effective market take-up.\n\n\n\u0022","finalResults":"Q-Air project results are creating possibilities beyond the state-of-the-art and can bring great positive impacts across the architecture, construction, glazing industry and nature, to the owners, occupants and wider society. \n\nNEARLY ZERO ENERGY BUILDING - nZEB\nQ-Air project is helping to move the industry closer to a total sustainable, near-zero energy building (nZEB). Our research results and calculations have shown that the 5-chamber Q-Air glass fa\u00e7ade, which has an extremely high thermal insulation for the whole system (Ucw value as low as 0.30 W\/m2K), can diminish energy requirements for space heating substantially even in northern countries and can eliminate the requirement for heating in other countries. Heating demand is close to zero as such a system provides enough heat gain through visible light alone, which enables an almost heating-free solution in winter. This is achieved with glazing whose solar heat gain (g or SHGC value) does not exceed 0.3 and Q-Air can provide such (0.09 \u2013 0.34). Currently, CO2 emissions associated with buildings are strongly appearing due to winter heating, which means Q-Air can besides significant energy consumption reduction also extensively reduce CO2 emissions and contribute to climate protection. All this represents a new paradigm in reduction of dependency from fossil fuels in buildings.\n\n6-PANE TRANSPARENT GLAZING, THERMAL INSULATION Ucw \u2265 0.30 W\/m2K\nUp to six layers of glass (6-pane glazing or 5-chamber system) create an innovative insulating core to allow Q-Air to deliver unparalleled energy savings, healthy and comfortable indoor environment. Specifically, the fully transparent glazed fa\u00e7ade offers an extremely low thermal transmittance, Ucw \u2265 0.30 W\/m2K, Ug = 0.27 W\/m2K. Based on scientific knowledge, Q-Air uses flexing expansion glass and breathable innermost expansion chamber, which compensates for the climatic insulating gas expansion and contraction. Q-Air, which doesn\u00b4t need any external shading devices and is a prefabricated solution, is very fast and simple for use, and this way almost maintenance free solution. \n\nHIGH LIVING AND WORKING COMFORT - NATURAL DAYLIGHT, UNOBSTRUCTED VIEW, CONSTANT INDOOR TEMPERATURE, SOUND PROTECTION\nQ-Air creates an outstanding living and working environment for occupants with no viewing obstructions (due to no external sun shades) as well as facilitating a constant interior temperature, with no cold draughts (cold air movements) from the glass in winter (due to low Ug value) and equally no excessive solar heat gain (heat radiation from the glass or overheating) in summer. The fully transparent fa\u00e7ade maximises the passage of natural daylight, which contributes to an improved wellbeing of occupants and its sound insulating capabilities, in excess of 43 dB, ensures a peaceful environment too.","periodNumber":"2","periodFrom":"2018-01-01","periodTo":"2018-12-31","sourceUpdateDate":"2019-05-13 03:26:26","contentCreationDate":"2018-05-09 17:42:15","contentUpdateDate":"2018-05-09 17:42:05","lastUpdateDate":"2022-08-11 19:44:27","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"pubsum","title":"Report Summary","description":"Result: Publishable summary (FP7 SESAM) and Summary for publication (H2020 SyGMa)","displayCode":"\/Report Summary","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"207683","id":"737757","acronym":"Q-Air","title":"Sustainable Prefabricated Glass Fa\u00e7ade with Performance Exceeding State-of-the-art Glass Fa\u00e7ades","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/67\/11936537\/91827000","title":"climatic change mitigation","displayCode":"\/engineering and technology\/environmental engineering\/ecosystem-based management\/climatic change mitigation","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/53\/365\/30816592","title":"post-transition metals","displayCode":"\/natural sciences\/chemical sciences\/inorganic chemistry\/post-transition metals","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/63\/19232965","title":"amorphous solids","displayCode":"\/engineering and technology\/materials engineering\/amorphous solids","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/67\/425","title":"energy and fuels","displayCode":"\/engineering and technology\/environmental engineering\/energy and fuels","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/77\/479\/1267\/1749","title":"sustainable building","displayCode":"\/engineering and technology\/civil engineering\/architecture engineering\/sustainable architecture\/sustainable building","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"IA","title":"Innovation action","description":"Innovation action","displayCode":"\/Innovation action","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"de,en,es,fr,it,pl","rcn":"664235","id":"H2020-EU.3.","code":"H2020-EU.3.","frameworkProgramme":"H2020","pga":"H2020-EU.3.","title":"PRIORITY \u0027Societal challenges","shortTitle":"Societal Challenges","parent":{"rcn":"664087\/664086","code":"H2020-EC\/H2020"},"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"legalbasis","title":"Legal Basis","description":"Programme: Legal basis for research funding","displayCode":"\/Legal Basis","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedLegalBasis"}},{"availableLanguages":"de,en,es,fr,it,pl","rcn":"664087","id":"H2020-EC","code":"H2020-EC","frameworkProgramme":"H2020","pga":"H2020-EC","title":"Horizon 2020 Framework Programme","shortTitle":"EC Treaty","parent":{"rcn":"664086","code":"H2020"},"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"legalbasis","title":"Legal Basis","description":"Programme: Legal basis for research funding","displayCode":"\/Legal Basis","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedLegalBasis","uniqueProgrammePart":"true"}},{"availableLanguages":"de,en,es,fr,it,pl","rcn":"664143","id":"H2020-EU.2.","code":"H2020-EU.2.","frameworkProgramme":"H2020","pga":"H2020-EU.2.","title":"PRIORITY \u0027Industrial leadership\u0027","shortTitle":"Industrial Leadership","parent":{"rcn":"664087\/664086","code":"H2020-EC\/H2020"},"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"legalbasis","title":"Legal Basis","description":"Programme: Legal basis for research funding","displayCode":"\/Legal Basis","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedLegalBasis"}},{"availableLanguages":"en","rcn":"700218","id":"H2020_FTIPilot-01-2016","code":"FTIPilot-01-2016","frameworkProgramme":"H2020","title":"Fast Track to Innovation Pilot","parent":{"rcn":"20200","code":"H2020-Topics"},"relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"topic","title":"Topic","description":"Programme: Part of the Commission work programme implementing legal basis","displayCode":"\/Topic","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}},{"language":"en","availableLanguages":"en","code":"31051355","title":"Industrial sectoral change","displayCode":"\/Industrial sectoral change","attributes":{"classification":"topicKeyword","type":"isAbout"}},{"language":"en","availableLanguages":"en","code":"31051360","title":"Industrial innovation policy","displayCode":"\/Industrial innovation policy","attributes":{"classification":"topicKeyword","type":"isAbout"}},{"language":"en","availableLanguages":"en","code":"31051239","title":"New business opportunities","displayCode":"\/New business opportunities","attributes":{"classification":"topicKeyword","type":"isAbout"}},{"language":"en","availableLanguages":"en","code":"31051357","title":"New industrial value chains","displayCode":"\/New industrial value chains","attributes":{"classification":"topicKeyword","type":"isAbout"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedTopic"}}]},"contenttype":"project","attributes":{"source":"corda","type":"relatedProject"}},{"language":"en","availableLanguages":"en,any","uri":"\/docs\/results\/h2020\/737\/737757_PS\/q-air-glass-facade.jpg","alternativeText":"Q-Air glass facade","mimetype":"image\/jpeg","size":"1690713","contenttype":"webItem","attributes":{"source":"corda","type":"relatedResultAttachment"}},{"language":"en","availableLanguages":"en,any","uri":"\/docs\/results\/h2020\/737\/737757_PS\/q-air-transparent-element-aluminium-profile.jpg","alternativeText":"Q-Air transparent element - aluminium profile","mimetype":"image\/jpeg","size":"94196","contenttype":"webItem","attributes":{"source":"corda","type":"relatedResultAttachment"}},{"language":"en","availableLanguages":"en,any","uri":"\/docs\/results\/h2020\/737\/737757_PS\/q-air-glass-facade-elements.jpg","alternativeText":"Q-Air glass facade elements - transparent, translucent, opaque","mimetype":"image\/jpeg","size":"129573","contenttype":"webItem","attributes":{"source":"corda","type":"relatedResultAttachment"}},{"language":"en","availableLanguages":"en,any","uri":"\/docs\/results\/h2020\/737\/737757_PS\/q-air-transparent-element-polyamide-profile.jpg","alternativeText":"Q-Air transparent element - polyamide profile","mimetype":"image\/jpeg","size":"87300","contenttype":"webItem","attributes":{"source":"corda","type":"relatedResultAttachment"}},{"language":"en","availableLanguages":"en","id":"5fb3f2fb37378b46a30f3b2af70d9a83","archivedDate":"2025-07-03 00:00:00","physUrl":"https:\/\/trimo-group.com\/en\/trimo\/products\/facades-and-walls\/q-air\/q-air-project-h2020\/","status":"legacy","contenttype":"webLink","attributes":{"represents":"project","source":"corda","type":"relatedWebsite"}}]},"modelVersion":"132","icaVersion":"20.0.0-48f81e07"}