BOP-DSG solar field integration

Integration of DSG solar field and power block require specific equipment, the definition of which is closely related to start-up and shut-down procedures for the power plant. Non-conventional equipment and systems have been specified, according to the necessities of the different operation procedures to be implemented in this power plant. Mainly buffer tanks, water-steam separators and recirculation pumps are required, but other systems have also been completed or re-designed in order to comply with the operational requirements.

Lay-out and specific isometric drawings were generated in order to clearly define the integration of both parts. A global lay-out of the whole power plant was also produced.