Monitoring bone healing around endosseous implants: from multiscale modeling to the patient’s bed

Pubblicazioni

Spatio-temporal evolution of hydroxyapatite crystal thickness at the bone-implant interface

Autori: Sophie Le Cann, Elin Törnquist, Isabella Silva Barreto, Manon Fraulob, Hugues Albini Lomami, Mariana Verezhak, Manuel Guizar-Sicairos, Hanna Isaksson, Guillaume Haïat
Pubblicato in: Acta Biomaterialia, Numero 116, 2020, Pagina/e 391-399, ISSN 1742-7061
Editore: Elsevier BV
DOI: 10.1016/j.actbio.2020.09.021

Use of an instrumented hammer as a decision support system during rhinoplasty: validation on an animal model

Autori: L. Lamassoure, J. Giunta, G. Rosi, A.S. Poudrel, R. Bosc, G. Haïat
Pubblicato in: Computer Methods in Biomechanics and Biomedical Engineering, Numero 23/sup1, 2020, Pagina/e S162-S163, ISSN 1025-5842
Editore: Taylor & Francis
DOI: 10.1080/10255842.2020.1812848

Assessment of dental implant stability using resonance frequency analysis and quantitative ultrasound methods

Autori: Yoann Hériveaux, Romain Vayron, Manon Fraulob, Hugues Albini Lomami, Camille Lenormand, Guillaume Haïat
Pubblicato in: Journal of Prosthodontic Research, 2021, ISSN 1883-1958
Editore: Elsevier BV
DOI: 10.2186/jpr.jpr_d_20_00052

Modeling the debonding process of osseointegrated implants due to coupled adhesion and friction

Autori: Immel, K., Nguyen, VH, Haiat G and Sauer, R
Pubblicato in: Biomech. Model. Mechanobiol., 2022, ISSN 1617-7959
Editore: Springer Verlag
DOI: 10.48550/arxiv.2112.06793

Modeling ultrasonic wave propagation in a dental implant - Bone system

Autori: A. Dorogoy, G. Haïat, K. Shemtov-Yona, D. Rittel
Pubblicato in: Journal of the Mechanical Behavior of Biomedical Materials, Numero 103, 2020, Pagina/e 103547, ISSN 1751-6161
Editore: Elsevier BV
DOI: 10.1016/j.jmbbm.2019.103547

Determinants of the primary stability of cementless acetabular cup implants: A 3D finite element study

Autori: Immel, K., Nguyen, VH, Dubory, A, Flouzat-Lachaniette, CH, Sauer, R, and Haiat G
Pubblicato in: Computers in Biology and Medicine, 2022, ISSN 0010-4825
Editore: Pergamon Press Ltd.
DOI: 10.1016/j.compbiomed.2021.104607

Stress shielding at the bone‐implant interface: Influence of surface roughness and of the bone‐implant contact ratio

Autori: Maria Letizia Raffa, Vu‐Hieu Nguyen, Philippe Hernigou, Charles‐Henri Flouzat‐Lachaniette, Guillaume Haiat
Pubblicato in: Journal of Orthopaedic Research, 2020, ISSN 0736-0266
Editore: Elsevier BV
DOI: 10.1002/jor.24840

Multimodal Evaluation of the Spatiotemporal Variations of Periprosthetic Bone Properties

Autori: Manon Fraulob, Sophie Le Cann, Benjamin Voumard, Hirokazu Yasui, Keita Yano, Romain Vayron, Mami Matsukawa, Philippe Zysset, Guillaume Haïat
Pubblicato in: Journal of Biomechanical Engineering, Numero 142/12, 2020, ISSN 0148-0731
Editore: ASME
DOI: 10.1115/1.4048399

Micromechanical modeling of the contact stiffness of an osseointegrated bone–implant interface

Autori: Maria Letizia Raffa, Vu-Hieu Nguyen, Guillaume Haiat
Pubblicato in: BioMedical Engineering OnLine, Numero 18/1, 2019, ISSN 1475-925X
Editore: BioMed Central
DOI: 10.1186/s12938-019-0733-3

Modal Analysis of the Ancillary During Femoral Stem Insertion: A Study on Bone Mimicking Phantoms

Autori: Poudrel, AS., Nguyen, VH, Rosi, G, and Haiat G
Pubblicato in: Ann Biomed Eng, 2022, ISSN 0090-6964
Editore: Kluwer Academic Publishers
DOI: 10.1007/s10439-021-02887-9

Anatomical subject validation of an instrumented hammer using machine learning for the classification of osteotomy fracture in rhinoplasty.

Autori: Léo Lamassoure; Justine Giunta; Giuseppe Rosi; Anne-Sophie Poudrel; Jean-Paul Meningaud; Romain Bosc; Guillaume Haiat
Pubblicato in: Medical Engineering and Physics, Numero 1, 2021, ISSN 1350-4533
Editore: Elsevier BV
DOI: 10.1016/j.medengphy.2021.08.004

Using an Impact Hammer to Perform Biomechanical Measurements during Osteotomies: Study of an Animal Model

Autori: Lamassoure, L, Giunta, J, Rosi, G, Poudrel, AS, Bosc, R, and Haiat G
Pubblicato in: Proc Inst Mech Eng H, 2021, ISSN 0954-4119
Editore: Professional Engineering Publishing Ltd.

Ex vivo estimation of cementless femoral stem stability using an instrumented hammer

Autori: Hugues Albini Lomami, Camille Damour, Giuseppe Rosi, Anne-Sophie Poudrel, Arnaud Dubory, Charles-Henri Flouzat-Lachaniette, Guillaume Haiat
Pubblicato in: Clinical Biomechanics, Numero 76, 2020, Pagina/e 105006, ISSN 0268-0033
Editore: Pergamon Press Ltd.
DOI: 10.1016/j.clinbiomech.2020.105006

Analytical modeling of the interaction of an ultrasonic wave with a rough bone-implant interface

Autori: Yoann Hériveaux, Vu-Hieu Nguyen, Shiro Biwa, Guillaume Haïat
Pubblicato in: Ultrasonics, Numero 108, 2020, Pagina/e 106223, ISSN 0041-624X
Editore: Elsevier BV
DOI: 10.1016/j.ultras.2020.106223

Ultrasonic assessment of osseointegration phenomena at the bone-implant interface using convolutional neural network.

Autori: Yunsang Kwak; Vu-Hieu Nguyen; Yoann Hériveaux; Pierre Belanger; Junhong Park; Guillaume Haiat
Pubblicato in: J Acoust Soc Am, Numero 1, 2021, ISSN 0001-4966
Editore: Acoustical Society of America
DOI: 10.1121/10.0005272

Validation of an Instrumented Hammer for Rhinoplasty Osteotomies: A Cadaveric Study

Autori: 111. Giunta, J, Lamassoure, L, Rosi, G, Poudrel, AS, Meningaud, JP, Haiat G and Bosc, R
Pubblicato in: Facial Plast Surg Aesthet Med, 2021, ISSN 2689-3622
Editore: Mary Ann Liebert

Ex Vivo Evaluation of Cementless Acetabular Cup Stability Using Impact Analyses with a Hammer Instrumented with Strain Sensors

Autori: Antoine Tijou, Giuseppe Rosi, Philippe Hernigou, Charles-Henri Flouzat-Lachaniette, Guillaume Haïat
Pubblicato in: Sensors, Numero 18/2, 2018, Pagina/e 62, ISSN 1424-8220
Editore: Multidisciplinary Digital Publishing Institute (MDPI)
DOI: 10.3390/s18010062

Assessing the Acetabular Cup Implant Primary Stability by Impact Analyses: A Cadaveric Study

Autori: Adrien Michel, Romain Bosc, Jean-Paul Meningaud, Philippe Hernigou, Guillaume Haiat
Pubblicato in: PLOS ONE, Numero 11/11, 2016, Pagina/e e0166778, ISSN 1932-6203
Editore: Public Library of Science
DOI: 10.1371/journal.pone.0166778

Mimetization of the elastic properties of cancellous bone via a parameterized cellular material

Autori: Lucas Colabella, Adrián P. Cisilino, Guillaume Häiat, Piotr Kowalczyk
Pubblicato in: Biomechanics and Modeling in Mechanobiology, Numero 16/5, 2017, Pagina/e 1485-1502, ISSN 1617-7959
Editore: Springer Verlag
DOI: 10.1007/s10237-017-0901-y

Influence of soft tissue in the assessment of the primary fixation of acetabular cup implants using impact analyses

Autori: Romain Bosc, Antoine Tijou, Giuseppe Rosi, Vu-Hieu Nguyen, Jean-Paul Meningaud, Philippe Hernigou, Charles-Henri Flouzat-Lachaniette, Guillaume Haiat
Pubblicato in: Clinical Biomechanics, Numero 55, 2018, Pagina/e 7-13, ISSN 0268-0033
Editore: Pergamon Press Ltd.
DOI: 10.1016/j.clinbiomech.2018.03.013

Rapid High-Resolution Wavenumber Extraction from Ultrasonic Guided Waves Using Adaptive Array Signal Processing

Autori: Shigeaki Okumura, Vu-Hieu Nguyen, Hirofumi Taki, Guillaume Haïat, Salah Naili, Toru Sato
Pubblicato in: Applied Sciences, Numero 8/4, 2018, Pagina/e 652, ISSN 2076-3417
Editore: MDPI
DOI: 10.3390/app8040652

Three-dimensional Simulation of Quantitative Ultrasound in Cancellous Bone Using the Echographic Response of a Metallic Pin

Autori: Yoshiki Nagatani, Séraphin Guipieri, Vu-Hieu Nguyen, Christine Chappard, Didier Geiger, Salah Naili, Guillaume Haїat
Pubblicato in: Ultrasonic Imaging, Numero 39/5, 2017, Pagina/e 295-312, ISSN 0161-7346
Editore: Dynamedia, Inc.
DOI: 10.1177/0161734617698648

Ultrasonic characterization and multiscale analysis for the evaluation of dental implant stability: A sensitivity study

Autori: I. Scala, G. Rosi, V.-H. Nguyen, R. Vayron, G. Haiat, S. Seuret, S. Jaffard, S. Naili
Pubblicato in: Biomedical Signal Processing and Control, Numero 42, 2018, Pagina/e 37-44, ISSN 1746-8094
Editore: Elsevier BV
DOI: 10.1016/j.bspc.2017.12.007

Influence of anisotropic bone properties on the biomechanical behavior of the acetabular cup implant: a multiscale finite element study

Autori: Vu-Hieu Nguyen, Giuseppe Rosi, Salah Naili, Adrien Michel, Maria-Letizia Raffa, Romain Bosc, Jean-Paul Meningaud, Christine Chappard, Naoki Takano, Guillaume Haiat
Pubblicato in: Computer Methods in Biomechanics and Biomedical Engineering, Numero 20/12, 2017, Pagina/e 1312-1325, ISSN 1025-5842
Editore: Taylor & Francis
DOI: 10.1080/10255842.2017.1357703

Comparison of Resonance Frequency Analysis and of Quantitative Ultrasound to Assess Dental Implant Osseointegration

Autori: Romain Vayron, Vu-Hieu Nguyen, Benoît Lecuelle, Hugues Albini Lomami, Jean-Paul Meningaud, Romain Bosc, Guillaume Haiat
Pubblicato in: Sensors, Numero 18/5, 2018, Pagina/e 1397, ISSN 1424-8220
Editore: Multidisciplinary Digital Publishing Institute (MDPI)
DOI: 10.3390/s18051397

Reflection of an ultrasonic wave on the bone-implant interface: A numerical study of the effect of the multiscale roughness

Autori: Yoann Hériveaux, Vu-Hieu Nguyen, Guillaume Haïat
Pubblicato in: The Journal of the Acoustical Society of America, Numero 144/1, 2018, Pagina/e 488-499, ISSN 0001-4966
Editore: Acoustical Society of America
DOI: 10.1121/1.5046524

Evaluation of dental implant stability in bone phantoms: Comparison between a quantitative ultrasound technique and resonance frequency analysis

Autori: Romain Vayron, Vu-Hieu Nguyen, Benoît Lecuelle, Guillaume Haiat
Pubblicato in: Clinical Implant Dentistry and Related Research, Numero 20/4, 2018, Pagina/e 470-478, ISSN 1523-0899
Editore: B.C. Decker Inc.
DOI: 10.1111/cid.12622

Resonant frequency analysis of dental implants

Autori: D. Rittel, A. Dorogoy, G. Haïat, K. Shemtov-Yona
Pubblicato in: Medical Engineering & Physics, Numero 66, 2019, Pagina/e 65-74, ISSN 1350-4533
Editore: Elsevier BV
DOI: 10.1016/j.medengphy.2019.02.008

Monitoring cementless femoral stem insertion by impact analyses: An in vitro study

Autori: Antoine Tijou, Giuseppe Rosi, Romain Vayron, Hugues Albini Lomami, Philippe Hernigou, Charles-Henri Flouzat-Lachaniette, Guillaume Haïat
Pubblicato in: Journal of the Mechanical Behavior of Biomedical Materials, Numero 88, 2018, Pagina/e 102-108, ISSN 1751-6161
Editore: Elsevier BV
DOI: 10.1016/j.jmbbm.2018.08.009

Dependence of the primary stability of cementless acetabular cup implants on the biomechanical environment

Autori: Maria Letizia Raffa, Vu-Hieu Nguyen, Elisabeth Tabor, Katharina Immel, Victor Housset, Charles-Henri Flouzat-Lachaniette, Guillaume Haiat
Pubblicato in: Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2019, Pagina/e 095441191987925, ISSN 0954-4119
Editore: Professional Engineering Publishing Ltd.
DOI: 10.1177/0954411919879250

A modified Coulomb's law for the tangential debonding of osseointegrated implants

Autori: Immel, K., Duong, TX, Nguyen, VH, Haiat G and Sauer, R
Pubblicato in: Biomech Model Mechanobiol, 2019, ISSN 1617-7959
Editore: Springer Verlag

Biomechanical behaviours of the bone–implant interface: a review

Autori: Xing Gao, Manon Fraulob, Guillaume Haïat
Pubblicato in: Journal of The Royal Society Interface, Numero 16/156, 2019, Pagina/e 20190259, ISSN 1742-5689
Editore: The Royal Society
DOI: 10.1098/rsif.2019.0259

Elastography of the bone-implant interface

Autori: Yoann Hériveaux, Vu-Hieu Nguyen, Didier Geiger, Guillaume Haïat
Pubblicato in: Scientific Reports, Numero 9/1, 2019, ISSN 2045-2322
Editore: Nature Publishing Group
DOI: 10.1038/s41598-019-50665-4

Bone orthotropic remodeling as a thermodynamically-driven evolution

Autori: M. MARTIN, T. LEMAIRE, G. HAIAT, P. PIVONKA, and V. SANSALONE
Pubblicato in: Journal of mechanics in medicine and biology, 2019, ISSN 0219-5194
Editore: World Scientific

Reflection of an ultrasonic wave on the bone−implant interface: Effect of the roughness parameters

Autori: Yoann Hériveaux, Vu-Hieu Nguyen, Vladimir Brailovski, Cyril Gorny, Guillaume Haïat
Pubblicato in: The Journal of the Acoustical Society of America, Numero 145/6, 2019, Pagina/e 3370-3381, ISSN 0001-4966
Editore: Acoustical Society of America
DOI: 10.1121/1.5109668

Neutron microtomography to investigate the bone-implant interface – comparison with histological analysis

Autori: Guillaume, F, Le Cann, S, Tengattini, A, Törnquist, E, Falentin-Daudre, C, Albini Lomami, H, Petit, Y, Isaksson, H and Haiat G
Pubblicato in: Phys Med Biol, 2021, ISSN 0031-9155
Editore: Institute of Physics Publishing

A cadaveric validation of a method based on impact analysis to monitor the femoral stem insertion

Autori: Arnaud Dubory, Giuseppe Rosi, Antoine Tijou, Hugues Albini Lomami, Charles-Henri Flouzat-Lachaniette, Guillaume Haïat
Pubblicato in: Journal of the Mechanical Behavior of Biomedical Materials, Numero 103, 2020, Pagina/e 103535, ISSN 1751-6161
Editore: Elsevier BV
DOI: 10.1016/j.jmbbm.2019.103535

Using an Impact Hammer to Estimate Elastic Modulus and Thickness of a Sample During an Osteotomy

Autori: Alexis Hubert, Giuseppe Rosi, Romain Bosc, Guillaume Haiat
Pubblicato in: Journal of Biomechanical Engineering, Numero 142/7, 2020, ISSN 0148-0731
Editore: ASME
DOI: 10.1115/1.4046200

Multimodal characterization of the bone-implant interface using Raman spectroscopy and nanoindentation

Autori: Manon Fraulob, Siyuan Pang, Sophie Le Cann, Romain Vayron, Mathilde Laurent-Brocq, Soorya Todatry, Julio A.N.T. Soares, Iwona Jasiuk, Guillaume Haïat
Pubblicato in: Medical Engineering & Physics, Numero 84, 2020, Pagina/e 60-67, ISSN 1350-4533
Editore: Elsevier BV
DOI: 10.1016/j.medengphy.2020.07.013

Quantitative ultrasound assessment of the influence of roughness and healing time on osseointegration phenomena

Autori: M. Fraulob, R. Vayron, S. Le Cann, B. Lecuelle, Y. Hériveaux, H. Albini Lomami, C. H. Flouzat Lachaniette, G. Haïat
Pubblicato in: Scientific Reports, Numero 10/1, 2020, ISSN 2045-2322
Editore: Nature Publishing Group
DOI: 10.1038/s41598-020-78806-0

Ultrasonic Propagation in a Dental Implant

Autori: Yoann Hériveaux, Bertrand Audoin, Christine Biateau, Vu-Hieu Nguyen, Guillaume Haïat
Pubblicato in: Ultrasound in Medicine & Biology, Numero 46/6, 2020, Pagina/e 1464-1473, ISSN 0301-5629
Editore: Elsevier BV
DOI: 10.1016/j.ultrasmedbio.2020.01.025

Long-term stability and debonding of cementless implants

Autori: Immel, K., Nguyen, VH, Haiat G and Sauer, R
Pubblicato in: Proceedings in Applied Mathematics and Mechanics, 2021, ISSN 1617-7061
Editore: Wiley

Reflection of an ultrasonic wave on the bone-implant interface: Comparison of two-dimensional and three-dimensional numerical models

Autori: Yoann Hériveaux, Guillaume Haïat, Vu-Hieu Nguyen
Pubblicato in: The Journal of the Acoustical Society of America, Numero 147/1, 2020, Pagina/e EL32-EL36, ISSN 0001-4966
Editore: Acoustical Society of America
DOI: 10.1121/10.0000500

Effect of acoustic impedance mismatch as a function of frequency in transcranial ultrasound

Autori: Gupta, S., Haïat, G., Laporte, C. and Belanger, P.
Pubblicato in: IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 2021, ISSN 0885-3010
Editore: Institute of Electrical and Electronics Engineers

È in corso la ricerca di dati su OpenAIRE...

Si è verificato un errore durante la ricerca dei dati su OpenAIRE

Nessun risultato disponibile