Objective THE OPERATION OF A SYSTEM WITH SIMPLE UNSHIELDED SOLAR COLLECTORS (14,2 M2), A SMALL HEAT PUMP FOR DOMESTIC HOT WATER (ABOUT 1 KW) AND A LARGE HEAT PUMP (6 KW, 45 DEGREES C) FOR DOMESTIC HEATING VIA A SYSTEM OF RADIATORS IS BEING INVESTIGATED. THE LOW GRADE HEAT FOR THE ELECTRICAL HEAT PUMP IS EXTRACTED FROM THE SOIL WITH A SYSTEM OF 8 TUBES OF 14 M LONG. THREE DIFFERENT DRILLING METHODS WERE STUDIED OF WHICH THE COST VARIED FROM 50 DKR/M TO 170 DKR/M. THIS SYSTEM HAS NOW BEEN INSTALLED IN A HOUSE OF 137 M2 AND MEASUREMENTS ARE BEING CARRIED OUT. UP TILL NOW COP VALUES OF THE SYSTEM VARIED BETWEEN 2,7 AND 5 WITH AN AVERAGE VALUE OF 3,3, TAKING INTO ACCOUNT POWER NEEDED FOR PUMPS, VENTILATORS, ETC. THE 1 KW TAPWATER HEAT PUMP HAD AN SEASONALLY AVERAGED COP OF 2,8. THIS WORK IS COORDINATED WITH WORK DONE BY TNO, NETHERLANDS (SEE CONTRACT EE-A4-033). Programme(s) PRE-ENNONUC 2C - Energy research and development programme (EEC), 1979-1983 Topic(s) Data not available Call for proposal Data not available Funding Scheme Data not available Coordinator EUROPEAN HEAT PUMP CONSULTORS EU contribution No data Address SKOVSHOVEDVEJ 38 2929 Denmark See on map Total cost No data