HIGH SULPHUR LIGNITE IN CIRCULATING FLUIDIZED BED BOILER

Objetivo

Combustion of 4-5 % sulphur coal within tight emission limits (rate of sulphur removal better than 90 %) without limestone addition by using a high limestone-rich ash content coal in a circulating fluid bed combustor. The boiler (65 t/h of steam - 52,5 MW) will be connected with a district heating network providing steam to factories and residential buildings.

Main design features: thermal output 52,5 MW
Inside combustion chamber height: 19 m
Inside combustion chamber cross-section: 17 m2
Fluidizing velocity: up to 7 m/s
Fuel: unwashed 0-20 mm coal, ash content: 30 %
Primary air supplied by a 410 KW fan
Secondary air supplied by a 160 KW fan, and introduced at 2 different levels.
Start up fuel oil system
Recycling of part of the flue gas
Gas cleaning by electrostatic filter
Ash removal by pneumatic conveying system.

Convocatoria de propuestas

Data not available

Régimen de financiación

DEM - Demonstration contracts

Coordinador

SOCIETE MEDITERRANEEN DISTRIBUTION THERMIQUE
Aportación de la UE
Sin datos
Dirección
112 RUE DU DRAGON
13006 MARSEILLE
Francia

Ver en el mapa

Coste total
Sin datos