Microdosimetry study of a new radiation therapy method based on proton minibeams

Searching for OpenAIRE data...

Publications

Characterization of the Charge Collection Efficiency in Silicon 3-D-Detectors for Microdosimetry

Author(s): Diana Bachiller-Perea, Javier Garcia Lopez, Maria del Carmen Jimenez-Ramos, Faustino Gomez, Celeste Fleta, David Quirion, Adrian Garcia-Osuna, Consuelo Guardiola
Published in: IEEE Transactions on Instrumentation and Measurement, 70, 2021, Page(s) 1-11, ISSN 0018-9456
Publisher: Institute of Electrical and Electronics Engineers
DOI: 10.1109/tim.2021.3054631

Effect of X-ray minibeam radiation therapy on clonogenic survival of glioma cells

Author(s): Consuelo Guardiola, Yolanda Prezado, Christophe Roulin, Judith W.J. Bergs
Published in: Clinical and Translational Radiation Oncology, 13, 2018, Page(s) 7-13, ISSN 2405-6308
Publisher: Elservier
DOI: 10.1016/j.ctro.2018.07.005

Verification of a Monte Carlo dose calculation engine in proton minibeam radiotherapy in a passive scattering beamline for preclinical trials

Author(s): Consuelo Guardiola, Ludovic De Marzi, Yolanda Prezado
Published in: The British Journal of Radiology, 2020, Page(s) 20190578, ISSN 0007-1285
Publisher: British Institute of Radiology
DOI: 10.1259/bjr.20190578

Microdosimetric distributions for low energy protons with silicon-based 3D detectors and 1 Geant4-DNA simulations

Author(s): Bertolet A., Grilj V., Guardiola C., Harken A.D., Cortés-Giraldo M.A., Baratto-Roldán A., Carabe A.
Published in: Medical Physics, 2019, ISSN 2473-4209
Publisher: American Institute of Physics (US)

Impact of charge collection efficency and electronic noise on the performance of solid state 3D-microdetectors

Author(s): Juan Prieto-Pena, Faustino Gomez, Consuelo Guardiola, M C Jimenez-Ramos, Javier Garcia-Lopez, Anna Baratto-Roldán, Marta Baselga, Juan Pardo-Montero, Celeste Fleta
Published in: Physics in Medicine & Biology, 2020, ISSN 0031-9155
Publisher: Institute of Physics Publishing
DOI: 10.1088/1361-6560/ab87fa

Silicon 3D Microdetectors for Microdosimetry in Hadron Therapy

Author(s): Consuelo Guardiola, Celeste Fleta, David Quirion, Giulio Pellegrini, Faustino Gómez
Published in: Micromachines, 11/12, 2020, Page(s) 1053, ISSN 2072-666X
Publisher: Multidisciplinary Digital Publishing Institute (MDPI)
DOI: 10.3390/mi11121053

Microdosimetry in low energy proton beam at therapeutic-equivalent fluence rate with silicon 3D-cylindrical microdetectors

Author(s): C Guardiola, D Bachiller-Perea, J Prieto-Pena, M C Jiménez-Ramos, J García López, C Esnault, C Fleta, D Quirion, F Gómez
Published in: Physics in Medicine & Biology, 66/11, 2021, Page(s) 114001, ISSN 0031-9155
Publisher: Institute of Physics Publishing
DOI: 10.1088/1361-6560/abf811

Experimental validation of an analytical microdosimetric model based on Geant4-DNA simulations by using a silicon-based microdosimeter

Author(s): A. Bertolet, V. Grilj, C. Guardiola, A.D. Harken, M.A. Cortés-Giraldo, A. Baratto-Roldán, C. Fleta, M. Lozano, A. Carabe
Published in: Radiation Physics and Chemistry, 176, 2020, Page(s) 109060, ISSN 0969-806X
Publisher: Pergamon Press Ltd.
DOI: 10.1016/j.radphyschem.2020.109060