Periodic Reporting for period 1 - BioMech-3D (SENIOR BIOMECHANICAL 3D MODELLING RESEARCHER)
Reporting period: 2019-12-31 to 2020-12-30
Joint replacement surgery is one of the most frequently performed and effective surgeries worldwide. The aim of joint replacement is to relieve pain, restore biomechanical function and improve quality of life for patients. THR is a surgical procedure in which the hip joint is replaced by a prosthetic implant. It is normally conducted to relieve arthritis pain or treat severe physical joint damage following hip fracture. The OECD (OECD Health Statistics 2019) averages are 182 per 100 000 population for THR. Demographic change (increased mean age in population), increasing life expectancy, ongoing development of medical care, and economic growth resulted in a growth of THR surgeries. Therefore, the long-term survivorship of THR implants is increasingly relevant. As more patients undergo THR in younger age, the rate of revision hip implant surgeries due to complications has risen sharply due to higher mobility of patients. All hip replacements would eventually fail if in situ long enough because of processes such as infection, fracture, or a combination of normal tribological and biological processes, such as loosening and wear (Evans et al. 2019). The vast majority of THR are successful but approximately 5% of people who receive a hip implant may require revision surgery within 10 years, and 15% of patients needed revision surgery within 20 years (Evans et al. 2019). The most common reasons for revision are: mechanical failure of implant, periprosthetic bone fracture, repetitive dislocation, and infection. Revision THR causes growing and leads to important clinical and economic challenges in developed countries worldwide.
The goal of BioMech-3D was to add biomechanical evaluation to the workflow (Figure 1) of the design of the subject-specific hip implant for THR surgery; this would help to estimate how hip implant design/position would affect the hip joint function and to define the optimal implant design to restore the joint function. Further, this functionality will be used for planning of subject-specific implants on other human joints and will be integrated to MICE.
The individualized hip implant for THR surgery was designed based on analysis of 3D geometry of the bones of the patient and biomechanical evaluation of the patient-specific musculoskeletal model of the hip joint at the baseline and with the simulated implant, finite element analysis of the implant was performed; and the biomechanical evaluation was verified. Automatization methodology of musculoskeletal modelling and biomechanical analysis of hip implant was developed. Technical documentation of hip implant design was updated according ISO 13485.