Skip to main content
Go to the home page of the European Commission (opens in new window)
English en
CORDIS - EU research results
CORDIS
Content archived on 2022-12-23

Development of a fast fluorescence lifetime imaging device: time- and space-correlated single photon counting spectroscopy and its application in biology and medicine.

CORDIS provides links to public deliverables and publications of HORIZON projects.

Links to deliverables and publications from FP7 projects, as well as links to some specific result types such as dataset and software, are dynamically retrieved from OpenAIRE .

Exploitable results

Simultaneous acquisition of time- and space-information on the picosecond timescale became feasible by a recent advance in microchannel-plate photomultiplier-tube (MCP-PMT) technology: we present results obtained by two novel MCP-PMT detectors for time- and space-correlated single photon counting (TSCSPC), featuring a space-sensitive delay-line (DL) anode and quadrant-anode (QA), respectively, yielding continuous images. DL-System: the DL-MCP-PMT is a linear imager with 200 pixel at 100 µm resolution. The detector has a temporal IRF of 75 ps FWHM at a dynamic range of up to 5x105. We applied time-resolved spectroscopy to study the dynamic behaviour of DNA-probes (DAPI, TOTO, C350) in solution, in micelles, complexed to DNA, protein, and fixed cells. Ageing of DAPI stock solutions was reported. A polarity model for the photophysics of DAPI was proposed. Microscope lifetime images on the picosecond timescale showed clear potential for dynamic stray-light rejection and kinetic discrimination of probe-protein and probe-DNA complexes. First results on TOTO-fixed cell systems demonstrated high-quality kinetics at subcellular resolution, with up to 6 lifetime species at higher dye concentrations, characteristically distributed among individual cell compartments. A comparison with TOTO/DNA-suspensions was made that served as reference system. The analysis of multi-exponential fluorescence decays at subcellular resolution yields new information on characteristic probe-DNA interaction within individual cell compartments [1-3]. QA-System: the QA-MCP-PMT is a 2D imager with 400x400 pixel at 15 µm resolution. The detector has a temporal IRF of 80 ps FWHM, sufficient for 10 ps time resolution, at a dynamic range of 105 of the uncooled detector. A through-put of 105 cps is possible, in burst mode, the QA-detector can achieve 106 cps. We presented first data, obtained by a 50x50 channel QA microscope system of 1 µm space- and 10 ps time-resolution, demonstrating the full potential of TSCSPC. A modified Leitz Orthoplan/Ploemopak fluorescence microscope with the QA detector at the camera image plane (camera ocular = 3.2x) was used. Laser System: as excitation source served a Ti-Saph laser, run at 76 MHz repetition rate, 1 ps pulse width, and 760 nm. Frequency doubling produced 380 nm excitation. We also presented first images of 1 µm beads, loaded with fluorescein, analysed by global analysis: the fluorescence decays were two-exponential with 1 = 1.75 ns and 2 = 4.8 ns, at A1 = (91.7 ± 1.2)%. The major fast component is attributed to self-quenching of the high-concentration sample, since the fluorescence lifetime of xanthene dyes in rigid matrix is expected to be close the radiative lifetime of about 5 ns. The data were treated by a simple 4x4 ch global analysis, work on the full 50x50 ch version is in progress. The spatial resolution was FWHM = 1.5 µm but straightforward improvements in optics should result in an improved resolution of 0.5 µm [4-5]. Simultaneous TSCSPC spectroscopy and microscopy on the picosecond times scale, as described above, are two analytic methods that allow the acquisition of time-space data of superior quality, even at ultra-low excitation levels that are suitable for the study of living cells.

Searching for OpenAIRE data...

There was an error trying to search data from OpenAIRE

No results available

My booklet 0 0