Biopolymer-bioglass-antioxidant composite coatings for protection of 316LVM stainless steel sternal wires against inflammation-induced corrosion

Project description

Improving the durability of sternal wires

Sternal wires made from stainless steel are essential for closing the chest after heart surgery. However, they face significant challenges inside the human body. Corrosion caused by stress, confined spaces and reactive oxygen species lead to the release of harmful metals or even wire failure. With the support of the Marie Skłodowska-Curie Actions programme, the BioCoatCorr project will study how these wires degrade under realistic conditions. Researchers will develop a new protective coating made of zein biopolymer and cerium to improve wire durability and reduce corrosion, thereby enhancing the safety and quality of life for patients.

Objective

316LVM stainless steel sternal wires (SW) are widely used in cardiothoracic surgery for chest closure. However, in the aggressive environment of the human body, SWs are likely to corrode without a protective coating. This can lead to the release of harmful chromium and nickel in the surrounding tissues or, worse, SW rupture with potentially life-threatening complications, such as heart lacerations. SW degradation is caused by several factors, like chloride attack promoted by the creation of confined areas (e.g. at the chest bone/SW interface), plastic deformation due to the placement of SW around the bone, and tensile stress. Moreover, after implantation, the patients immune system unavoidably triggers an acute inflammation episode during which leukocytes generate reactive oxygen species (ROS), such as H2O2 and radicals (notably via the Fenton reactions), that also contribute to the SW deterioration. BioCoatCorr aims to investigate in-depth in vitro degradation of 316LVM SW in phosphate buffer saline involving simultaneously multiple degradation factors (plastic deformation, H2O2, confined areas). For that purpose, electrochemical measurements (corrosion potential monitoring coupled with impedance spectroscopy) will be carried out at various levels of wire deformation. Furthermore, a novel zein-bioglass-cerium protective coating capable of withstanding the harsh SW operative conditions will be prepared using electrophoretic deposition (EPD). The zein biopolymer has been selected for its ductile properties required for matching the significant SW deformation. The cerium will have the functionality of ROS scavenger, limiting the polymer degradation. The anti-corrosion behaviour and mechanical properties of the coatings will be assessed as a function of the synthesis parameters. The results of BioCoatCorr will contribute to developing the next-generation SW with enhanced durability and thus improve patient life quality postoperatively.

Fields of science (EuroSciVoc)

Keywords

Programme(s)

Topic(s)

Funding Scheme

HORIZON-TMA-MSCA-PF-EF - HORIZON TMA MSCA Postdoctoral Fellowships - European Fellowships

See all projects funded under this funding scheme

Call for proposal

(opens in new window) HORIZON-MSCA-2024-PF-01

See all projects funded under this call

Coordinator

INSTITUT DE LA CORROSION SASU
Net EU contribution
€ 242 260,56
Address
RUE RIVOALON 220 TECHNOPOLE DE BREST IROISE
29200 Brest
France
Region
Bretagne Bretagne Finistère
Activity type
Research Organisations
Links
Total cost
No data