1. Simulating façade fires using FireFOAM
Ejected fires from windows can lead to vertical fire spread, resulting in cascading effects. The present study aims to apply FireFOAM, for the first time, to this fire scenario. The computational domain contain two parts, the physical domain includes an enclosure of 0.4 m (L) × 0.4 m (W) × 0.4 m (H) with an attached façade wall of 1.2 m (W) ×1.8 m (H), and the extend air domain is 0.8 m (L) × 1.2 m (W) × 1.8 m (H). The extended eddy dissipation concept proposed and implemented in FireFOAM by Chen et al. [1] is used for combustion. The one k-equation eddy viscosity model [2] is used for sub-grid scale turbulence modelling. The numerical predictions are compared with the measurements of Hu et al. [3]. The predicted flame height and flame width are in reasonably good agreement with the measurements. The external vertical plume temperature profiles near the façade wall are also compared with the measurements, its predicted value are close to measurements. The present work has laid a good foundation to extend the application of FireFOAM to full-scale façade fire modelling.
2. Effect of parallel curtain walls (façade wall) on the upward flame spread characteristics and mass loss rate over PMMA
PMMA belongs to slow-burning characteristic materials comparing with other polymers. When the flame front reached the plate tail, the material at ignition position was still burning, and no burn-out area would emerge, namely the whole PMMA board was burning from bottom to top. Hence this scenario could be regarded as a PMMA wall fire after the upward flame spread has reached the steady process. The main material area exposed to the flame can be calculated by:
(1)
Where the S, W, L and T are total surface area, sample width, sample length, and sample thickness.
For fire safety consideration, the characteristic length transition is often used to quantify the dynamic fire behaviour when dealing with irregular fuel shape. In this work, as the sample length is much longer than the sample width, the definition of the hydraulic diameter has been adopted for characteristics length calculation following its use for irregular fuel shape consideration as the equivalent diameter method, which is most commonly used for the characteristics length, only works for rectangular shape with length and width being in the same level. The hydraulic diameter D can be calculated by:
(2)
3. Effect of sidewall constraint on the flame extension beneath a ceiling induced by ejected flames from a carriage in tunnels
The present knowledge on the characteristics of ceiling jets caused by ejected flames from carriages in tunnels is inadequate. And to the best of our knowledge, no investigations have addressed the effect of sidewall–carriage distance (the distance between tunnel sidewall and fire source) on the ceiling flame spread characteristics in tunnel fires.