European Commission logo
français français
CORDIS - Résultats de la recherche de l’UE
CORDIS

Intuitive Natural Prosthesis UTilization

Livrables

Decision on terminal prototyping test device

It will be decided, which kind of prosthesis test system (physical prosthesis or prosthesis emulator or software) will be made available to each partner requiring such a device for testing purposes.

Test for evaluating the ability of simultaneous proportional control

A test to measure the performance of patients using simultaneous proportional prosthetic control

Preferred training method

Knowledge on which training leads to better control of the simultaneous proportionally controlled prosthesis in daily life tasks, the computerbased training or conventionally based training

Advantages of simultaneous proportional over conventional control

Knowledge on the prosthetic control device with which users have better quality of movements in multi-DOF prostheses: the simultaneous proportional prosthetic control device or conventionally control regime

Computer-based rehabilitation game

A computer-based rehabilitation game in which the avatar is controlled with algorithms used in controlling a prosthetic hand simultaneously and proportionally

Feedback in game

Determine the types of feedback that users of different capacity can use for in-game learning controlling the avatar in the rehabilitation game

Activity monitoring system

An activity monitoring system of prosthetic use in daily life tasks

Project Homepage

The project homepage will make information on the project including participants, project duration, funding body and main achieved results accessible to the public.

Publications

Online mapping of EMG signals into kinematics by autoencoding

Auteurs: Ivan Vujaklija, Vahid Shalchyan, Ernest N. Kamavuako, Ning Jiang, Hamid R. Marateb, Dario Farina
Publié dans: Journal of NeuroEngineering and Rehabilitation, Numéro 15/1, 2018, ISSN 1743-0003
Éditeur: BioMed Central
DOI: 10.1186/s12984-018-0363-1

Translating Research on Myoelectric Control into Clinics—Are the Performance Assessment Methods Adequate?

Auteurs: Ivan Vujaklija, Aidan D. Roche, Timothy Hasenoehrl, Agnes Sturma, Sebastian Amsuess, Dario Farina, Oskar C. Aszmann
Publié dans: Frontiers in Neurorobotics, Numéro 11, 2017, ISSN 1662-5218
Éditeur: Frontiers Research Foundation
DOI: 10.3389/fnbot.2017.00007

User adaptation in Myoelectric Man-Machine Interfaces

Auteurs: Janne M. Hahne, Marko Markovic, Dario Farina
Publié dans: Scientific Reports, Numéro 7/1, 2017, ISSN 2045-2322
Éditeur: Nature Publishing Group
DOI: 10.1038/s41598-017-04255-x

A Biologically-Inspired Robust Control System for Myoelectric Control

Auteurs: Silvia Muceli, Ivan Vujaklija, Ning Jiang, Sebastian Amsuess, Bernhard Graimann, Oskar C. Aszmann, Dario Farina
Publié dans: Converging Clinical and Engineering Research on Neurorehabilitation II, Biosystems & Biorobotics, vol 15. Springer, Cham, Numéro October 2016, 2017, Page(s) 975-979, ISBN 978-3-319-46668-2
Éditeur: Springer, Cham

Upper Limb Myoelectric Prostheses: User and Therapist Perspectives on Quantifying Benefits of Pattern Recognition Control

Auteurs: Andreas Franzke, Raoul Bongers, Barbara Pobatschnig, Fabian Unglaube, Andreas Kranzl, Alessio Murgia, Corry van der Sluis
Publié dans: Myoelectric Controls and Upper Limb Prosthetics Symposium 2017, Fredericton, Canada, Numéro August 2017, 2017, ISBN 978-1-55131-190-6
Éditeur: Myoelectric Control Symposium 2017

Influence of a transradial amputation on neuromuscular control of forearm muscles

Auteurs: Morten B. Kristoffersen, Andreas Franzke, Alessio Murgia, Raoul Bongers, Corry van der Sluis,
Publié dans: Myoelectric Controls and Upper Limb Prosthetics Symposium 2017, Fredericton, Canada, Numéro August 2017, 2017, ISBN 978-1-55131-190-6
Éditeur: Myoelectric Control Symposium

User training for pattern-recognition based myoelectric prostheses using a serious game

Auteurs: Morten B. Kristoffersen, Andreas Franzke, Alessio Murgia, Corry van der Sluis, Raoul Bongers
Publié dans: Myoelectric Controls and Upper Limb Prosthetics Symposium 2017, Fredericton, Canada, Numéro August 2017, 2017, ISBN 978-1-55131-190-6
Éditeur: Myoelectric Control Symposium

Neural Expectation Maximization

Auteurs: Klaus Greff, Sjoerd van Steenkiste, Jürgen Schmidhuber
Publié dans: Proceedings of the 5th International Conference on Learning Representations, Numéro August 2017, 2017
Éditeur: ICLR 2017

Current Issues with Multi-DOF Myoelectric Hand Prostheses and Indications for Testing Pattern Recognition Based Control

Auteurs: Andreas Franzke, Raoul Bongers, Barbara Pobatschnig, Fabian Unglaube, Andreas Kranzl, Alessio Murgia, Corry van der Sluis
Publié dans: Proceedings of the International Society for Prosthetics and Orthotics 16th World Congress, South Africa, Numéro May 2017, 2017, ISBN 978-87-93486-01-0
Éditeur: ISPO South Africa

The Sacred Infrastructure for Computational Research

Auteurs: Klaus Greff, Aaron Kleink, Martin Chovanec, Frank Hutterk, Jürgen Schmidhuber
Publié dans: Proceedings of the 15th Python in Science Conf (SCIPY2017), Numéro July 2017, 2017
Éditeur: Proc. of the 15th Python in Science Conf

User training for pattern-recognition based myoelectric prostheses using a serious game

Auteurs: Morten B. Kristoffersen, Andreas Franzke, Alessio Murgia, Corry van der Sluis, Raoul Bongers
Publié dans: Proceedings of the International Society for Prosthetics and Orthotics 16th World Congress, South Africa, Numéro May 2017, 2017
Éditeur: ISPO South Africa

Differences in Sound Hand and Prosthetic Prehension from a Coordination Dynamics Perspective

Auteurs: Andreas Franzke, Alessio Murgia, Corry van der Sluis, Raoul Bongers
Publié dans: Proceedings of the International Society for Prosthetics and Orthotics 16th World Congress, South Africa, Numéro May 2017, 2017, ISBN 978-87-93486-01-0
Éditeur: ISPO South Africa

A Coordination Dynamics Approach to Test Multi-DOF Myoelectric Prostheses: Preliminary Results

Auteurs: Andreas Franzke, Alessio Murgia, Corry van der Sluis, Raoul Bongers
Publié dans: Trent International Prosthetic Symposium, ISPO, United Kingdom, Numéro October 2016, 2016
Éditeur: TIPS UK

Performance and Satisfaction with Intuitive Multifunctional Hand Prosthesis Control

Auteurs: Sebastian Amsuess, Ivana Sreckovic, Birgit Bischof, Thomas Fuchsberger
Publié dans: Proceedings of the International Society for Prosthetics and Orthotics 16th World Congress, South Africa, Numéro May 2017, 2017
Éditeur: ISPO

Robustness of regression-based myoelectric control in a clinical setting

Auteurs: Janne Hahne, Meike Schweisfurth and Dario Farina
Publié dans: Myoelectric Controls and Upper Limb Prosthetics Symposium 2017, Fredericton, Canada, Numéro August 2017, 2017, ISBN 978-1-55131-190-6
Éditeur: Myoelectric Control Symposium 2017

Serious gaming to train pattern-recognition based myoelectric control

Auteurs: Morten B. Kristoffersen, Andreas Franzke, Alessio Murgia, Corry van der Sluis, Raoul Bongers
Publié dans: Trent International Prosthetic Symposium, ISPO, United Kingdom, Numéro October 2016, 2016
Éditeur: TIPS UK

Performance and Satisfaction with Intuitive Multifunctional Hand Prosthesis Control

Auteurs: Sebastian Amsuess, Ivana Sreckovic, Birgit Bischof, Thomas Fuchsberger
Publié dans: Myoelectric Controls and Upper Limb Prosthetics Symposium 2017, Fredericton, Canada, Numéro August 2017, 2017, ISBN 978-1-55131-190-6
Éditeur: Myoelectric Control Symposium

Droits de propriété intellectuelle

Silikongraphit-Silberstoff Elektroden

Numéro de demande/publication: DE 102017126463.9
Date: 2017-11-10
Demandeur(s): OTTOBOCK SE & CO. KGAA

Liner mit medialer Kontaktierung für transradial-transcarpal Amputierte

Numéro de demande/publication: DE 102017126462.0
Date: 2017-11-10
Demandeur(s): OTTOBOCK SE & CO. KGAA

Ovale Linerform für transradial Amputierte

Numéro de demande/publication: DE 102017126472.8
Date: 2017-11-10
Demandeur(s): OTTOBOCK SE & CO. KGAA

Parylen (cvd) beschichtete Silikongraphit-Leiter

Numéro de demande/publication: DE 102017126465.5
Date: 2017-11-10
Demandeur(s): OTTOBOCK SE & CO. KGAA

Silikongraphit-Silberstoff Elektroden

Numéro de demande/publication: DE 102017126463.9
Date: 2017-11-10
Demandeur(s): OTTOBOCK SE & CO. KGAA

Parylen (cvd) beschichtete Silikongraphit-Leiter

Numéro de demande/publication: DE 102017126465.5
Date: 2017-11-10
Demandeur(s): OTTOBOCK SE & CO. KGAA

Liner mit medialer Kontaktierung für transradial-transcarpal Amputierte

Numéro de demande/publication: DE 102017126462.0
Date: 2017-11-10
Demandeur(s): OTTOBOCK SE & CO. KGAA

Ovale Linerform für transradial Amputierte

Numéro de demande/publication: DE 102017126472.8
Date: 2017-11-10
Demandeur(s): OTTOBOCK SE & CO. KGAA

Recherche de données OpenAIRE...

Une erreur s’est produite lors de la recherche de données OpenAIRE

Aucun résultat disponible