European Commission logo
français français
CORDIS - Résultats de la recherche de l’UE
CORDIS

VolThinSens. Challenging societal needs involving ions detection: New strategies for the development of Voltammetry ion Sensors based on Thin membranes

Publications

A sustainable amperometric biosensor for the analysis of ascorbic, benzoic, gallic and kojic acids through catechol detection. Innovation and signal processing

Auteurs: Ana Casanova, María Cuartero, Yolanda Alacid, Carmen M. Almagro, Francisco García-Cánovas, María S. García, Joaquín A. Ortuño
Publié dans: The Analyst, Numéro 145/10, 2020, Page(s) 3645-3655, ISSN 0003-2654
Éditeur: Royal Society of Chemistry
DOI: 10.1039/c9an02523e

Why ammonium detection is particularly challenging but insightful with ionophore-based potentiometric sensors – an overview of the progress in the last 20 years

Auteurs: María Cuartero, Noemi Colozza, Bibiana M. Fernández-Pérez, Gastón A. Crespo
Publié dans: The Analyst, Numéro 145/9, 2020, Page(s) 3188-3210, ISSN 0003-2654
Éditeur: Royal Society of Chemistry
DOI: 10.1039/d0an00327a

Electrochemical biosensor for glycine detection in biological fluids

Auteurs: Qianyu Wang Yujie Liu Jonatan C. Campillo-Brocal Amparo Jiménez-Quero Gaston A. Crespo MaríaCuartero
Publié dans: Biosensors and Bioelectronics, Numéro 182, 2021, Page(s) 113154, ISSN 0956-5663
Éditeur: Pergamon Press Ltd.
DOI: 10.1016/j.bios.2021.113154

Subnanomolar detection of ions using thin voltammetric membranes with reduced Exchange capacity

Auteurs: Kequan Xu, Gaston A. Crespo, Maria Cuartero
Publié dans: Sensors and Actuators B: Chemical, Numéro 321, 2020, Page(s) 128453, ISSN 0925-4005
Éditeur: Elsevier BV
DOI: 10.1016/j.snb.2020.128453

Spectroelectrochemical Evidence of Interconnected Charge and Ion Transfer in Ultrathin Membranes Modulated by a Redox Conducting Polymer

Auteurs: Yujie Liu, Alexander Wiorek, Gaston A. Crespo, Maria Cuartero
Publié dans: Analytical Chemistry, Numéro 92/20, 2020, Page(s) 14085-14093, ISSN 0003-2700
Éditeur: American Chemical Society
DOI: 10.1021/acs.analchem.0c03124

Epidermal Patch with Glucose Biosensor: pH and Temperature Correction toward More Accurate Sweat Analysis during Sport Practice

Auteurs: Alexander Wiorek, Marc Parrilla, María Cuartero, Gastón A. Crespo
Publié dans: Analytical Chemistry, Numéro 92/14, 2020, Page(s) 10153-10161, ISSN 0003-2700
Éditeur: American Chemical Society
DOI: 10.1021/acs.analchem.0c02211

Wearable Potentiometric Sensors for Medical Applications

Auteurs: María Cuartero, Marc Parrilla, Gaston Crespo
Publié dans: Sensors, Numéro 19/2, 2019, Page(s) 363, ISSN 1424-8220
Éditeur: Multidisciplinary Digital Publishing Institute (MDPI)
DOI: 10.3390/s19020363

Modern creatinine (Bio)sensing: Challenges of point-of-care platforms

Auteurs: Rocío Cánovas, María Cuartero, Gastón A. Crespo
Publié dans: Biosensors and Bioelectronics, Numéro 130, 2019, Page(s) 110-124, ISSN 0956-5663
Éditeur: Pergamon Press Ltd.
DOI: 10.1016/j.bios.2019.01.048

Ferrocene self assembled monolayer as a redox mediator for triggering ion transfer across nanometer-sized membranes

Auteurs: Maria Cuartero, Lijun Chai, Biaobiao Zhang, Roland De Marco, Gastón A. Crespo
Publié dans: Electrochimica Acta, Numéro 315, 2019, Page(s) 84-93, ISSN 0013-4686
Éditeur: Pergamon Press Ltd.
DOI: 10.1016/j.electacta.2019.05.091

Wearable Potentiometric Ion Patch for On-Body Electrolyte Monitoring in Sweat: Toward a Validation Strategy to Ensure Physiological Relevance

Auteurs: Marc Parrilla, Inmaculada Ortiz-Gómez, Rocío Cánovas, Alfonso Salinas-Castillo, María Cuartero, Gastón A. Crespo
Publié dans: Analytical Chemistry, Numéro 91/13, 2019, Page(s) 8644-8651, ISSN 0003-2700
Éditeur: American Chemical Society
DOI: 10.1021/acs.analchem.9b02126

Lowering the Limit of Detection of Ion-selective Membranes Backside Contacted with a Film of Poly(3-octylthiophene)

Auteurs: Kequan Xu, Maria Cuartero, Gaston A. Crespo
Publié dans: Sensors and Actuators B: Chemical, Numéro 297 / 1, 2019, Page(s) 126781, ISSN 0925-4005
Éditeur: Elsevier BV
DOI: 10.1016/j.snb.2019.126781

Cytotoxicity Study of Ionophore-Based Membranes: Toward On-Body and in Vivo Ion Sensing

Auteurs: Rocío Cánovas, Sara Padrell Sánchez, Marc Parrilla, María Cuartero, Gastón A. Crespo
Publié dans: ACS Sensors, Numéro 4/9, 2019, Page(s) 2524-2535, ISSN 2379-3694
Éditeur: American Chemical Society
DOI: 10.1021/acssensors.9b01322

Polyaniline Films as Electrochemical-Proton Pump for Acidification of Thin Layer Samples

Auteurs: Alexander Wiorek, Maria Cuartero, Roland De Marco, Gaston A. Crespo
Publié dans: Analytical Chemistry, Numéro 91/23, 2019, Page(s) 14951-14959, ISSN 0003-2700
Éditeur: American Chemical Society
DOI: 10.1021/acs.analchem.9b03402

Thin-Layer Potentiometry for Creatinine Detection in Undiluted Human Urine Using Ion-Exchange Membranes as Barriers for Charged Interferences

Auteurs: Yujie Liu, Rocío Cánovas, Gastón A. Crespo, María Cuartero
Publié dans: Analytical Chemistry, Numéro 92/4, 2020, Page(s) 3315-3323, ISSN 0003-2700
Éditeur: American Chemical Society
DOI: 10.1021/acs.analchem.9b05231

Electrochemical sensors for in-situ measurement of ions in seawater

Auteurs: Maria Cuartero
Publié dans: Sensors and Actuators B: Chemical, Numéro 334, 2021, Page(s) 129635, ISSN 0925-4005
Éditeur: Elsevier BV
DOI: 10.1016/j.snb.2021.129635

Recherche de données OpenAIRE...

Une erreur s’est produite lors de la recherche de données OpenAIRE

Aucun résultat disponible