QUALITY CRITERIA, TOLERANCES, LIMITING VALUES, DOSIMETRY AND OPTIMIZATION IN A NUMBER OF FLUOROSCOPIC, DIGITAL FLUOROSCOPIC, DSA AND DIGITAL RADIOLOGICAL SYSTEMS

Objetivo

This contract initiates work on bridging a gap which has opened up between major advances in radiological equipment and techniques, and the lack of developments in quality assurance, patient and staff Dosimetry, comparative dosimetry, and optimization of automatic exposure control and automatic brightness control in a number of systems.
The advantages and disadvantages of digital imaging methods are under evaluation. Imaging capabilities of digital II radiography were compared with conventional film and screen radiography. The parameters of spatial resolution, contrast and entrance dose (abdomen phantom) were measured. Depending on the dose, spatial resolution decreased significantly below a certain level for each image intensifier diameter. To lower the dose as much as possible it was fundamental to know what dose and image quality are necessary for special diagnostic questions.

Indications for digital II radiography can be divided into 3 groups:
highest image quality is necessary (eg examinations of the gastrointestinal tract in double contrast);
lower image quality (and dose) is possible (eg phleborgraphy, hysterosalpinography, examinations of the gastrointestinal tract in monocontrast);
lowest dose is necessary (eg functional examinations of the gastrointestinal tract in paediatrics, pelvimetry).

By measuring physical parameters and comparing images of specimen and patients with different preselected dose values recommendations were given for dose selection for these 3 classes of examinations. For examinations of the class 1 the entrance dose was in the range of 25% to 50%, for examinations of the class 3 the entrance dose was 5% compared to a film and screen combination.

For imaging of the chest digital II radiography and digital storage phosphor radiography were compared with spotfilm techniques, film/screen techniques and slot techniques. As a result digital II radiography cannot be recommended for imaging of the lung, because the spatial resolution for large entrance fields is not sufficient. Storage phosphor radiographs demonstrated a high image quality but gave only limited additional diagnostic information compared to film/screen radiographs. Dose could be lowered to 75% to 50% of film and screen combination. Dose values under 50% were connected to a significant decrease of i mage quality. Best imaging capabilities for chest at the wall stand were demonstrated by the slot technique.

Constancy tests are being developed for digital radiography and after 1 year it will be decided which parameters are necessary to characterize image quality of a digital image intensifier system.
Task 1 :
Characterization, evaluation, comparison and optimization of automatic exposure control and automatic brightness control in a number of systems.

Task 2 :
Identification of important variables, and where possible tolerances and limiting values, in the fluoroscopic/TV/cine/100mm/multiformat cameras and digital imaging systems. The variables are to include those suitable for constancy testing at one level and for acceptance or write-off of equipment at another.

Task 3 :
Dosimetry and optimization studies of conventional and corresponding digital techniques for cardiac, gastrointestinal, chest, peripheral vascular and paediatric studies.

Task 4 :
Patient and staff dosimetry in selected clinical studies.

In addition to the above, the work of the contract is being coordinated with that of Dr. Th. Schmidt BI6-343 so that the work programme in Tasks 3 and 4 will be integrated and the progress and final reports will be grouped.

Ámbito científico (EuroSciVoc)

CORDIS clasifica los proyectos con EuroSciVoc, una taxonomía plurilingüe de ámbitos científicos, mediante un proceso semiautomático basado en técnicas de procesamiento del lenguaje natural. Véas: El vocabulario científico europeo..

Para utilizar esta función, debe iniciar sesión o registrarse

Programa(s)

Programas de financiación plurianuales que definen las prioridades de la UE en materia de investigación e innovación.

Tema(s)

Las convocatorias de propuestas se dividen en temas. Un tema define una materia o área específica para la que los solicitantes pueden presentar propuestas. La descripción de un tema comprende su alcance específico y la repercusión prevista del proyecto financiado.

Datos no disponibles

Convocatoria de propuestas

Procedimiento para invitar a los solicitantes a presentar propuestas de proyectos con el objetivo de obtener financiación de la UE.

Datos no disponibles

Régimen de financiación

Régimen de financiación (o «Tipo de acción») dentro de un programa con características comunes. Especifica: el alcance de lo que se financia; el porcentaje de reembolso; los criterios específicos de evaluación para optar a la financiación; y el uso de formas simplificadas de costes como los importes a tanto alzado.

CSC - Cost-sharing contracts

Coordinador

Federated Dublin Volontary Hospital
Aportación de la UE
Sin datos
Dirección
Garden Hill House
8 Dublin
Irlanda

Ver en el mapa

Coste total

Los costes totales en que ha incurrido esta organización para participar en el proyecto, incluidos los costes directos e indirectos. Este importe es un subconjunto del presupuesto total del proyecto.

Sin datos

Participantes (2)

Mi folleto 0 0