HIGH EFFICIENCY PV SYSTEM FOR A NURSERY SCHOOL

Objective

To install 6.3 kWp of panels on a roof. By provision of a reflecting surface and cooling ducts for panels, it is hoped to achieve 20% more output. Panels grid connected through inverter. Installed at a nursery school, near Stuttgart. Building design to be adapted to incorporate solar system.

The building design has been adapted to incorporate solar system. Modules are grid connected through inverter.
Installed at a nursery school, near Stuttgart.
Nr. subsystems : 1
Power subsystems : 6.36 kWp
Total power : 6.36 kWp
Backup : grid
Nr. of modules : 120
Module description : DASA, type MQ 36 D, 53 Wp. 976 x 463 mm, monocrystalline.
Connection : data not available
Support : integrated into roof (but mounted on top of the existing water tight roof). Can be flapped up for maintenance.
Max. pwr. trcker : in the inverter ?
Chrg controller : none
Battery : none
Inverter : Kraschny-Elektronik
Inv. in (V) : 100 V dc
inv. ou (V) : 230 V ac
Inv. power (kW) : 5 kW
Load descript. : feeding the grid
Monitoring : started in September 93, after mounting of the electricity counter by Neckarwerke.

Call for proposal

Data not available

Coordinator

GEMEINDE WINTERBACH
EU contribution
No data
Address
MARKTPLAZ 2
73650 WINTERBACH
Germany

See on map

Total cost
No data