CORDIS proporciona enlaces a los documentos públicos y las publicaciones de los proyectos de los programas marco HORIZONTE.
Los enlaces a los documentos y las publicaciones de los proyectos del Séptimo Programa Marco, así como los enlaces a algunos tipos de resultados específicos, como conjuntos de datos y «software», se obtienen dinámicamente de OpenAIRE .
Resultado final
Assessment of the results of T1.1 regarding pending safety issues, M32, TÜV, IRSN, FRA-SAS, TRACTEBEL
Data management plan (se abrirá en una nueva ventana)Data management plan M3 FRASAS LGI HTR SAS PU
Scoping study on the stability of B4C as a burnable poison (se abrirá en una nueva ventana)Scoping study on the stability of B4C as a burnable poison, M24, JRC, TÜV
Common European basis for licensing of an HTR at European level (se abrirá en una nueva ventana)Common European basis for licensing of an HTR at European level, M24, TRACTEBEL, IRSN, JRC, NCBJ, FRA-SAS
HTR fuel back-end : Graphite management, spent TRISO fuel reprocessing and recycling alternatives (se abrirá en una nueva ventana)HTR fuel back-end : Graphite management, spent TRISO fuel reprocessing and recycling alternatives, M30, VTT, IChTJ, JRC, NNL, FRA-GmbH
Path and conditions for pre-licensing of a HTR in a European country (se abrirá en una nueva ventana)Path and conditions for pre-licensing of a HTR in an European country, M32, IRSN, TÜV, NCBJ, FRASAS
CFD simulations of a detonation of a hydrogen/air mixture in a hydrogen production facility coupled with a nuclear reactor (se abrirá en una nueva ventana)The report presents a safety study performed with the CFD tool CALIF3S, developedat IRSN, to evaluate the consequences of a potential accident of hydrogen release on the combined plant. The selectedscenario is the detonation of a stoichiometric hydrogen/air cloud.The explosive cloud is determined with the Multi Energy Method (MEM), reconstructed for hydrogen/air mixtures.The volume of the cloud is obtained, assuming that the reactor buildings are designed to withstand a 100 mbar overpressure wave (same value as for recent PWRs).Several numerical computations of detonation are performed and the impact of the blast waves on the reactor building is studied.A safety distance for the reactor building is also evaluated: the reactor should be located at around 470m from the leak to prevent damagesto its structure. Finally, the impact of the addition of a wall in front of the reactor building as safety barrier is carried out.
Identification of gaps in European Codes and Standards for the design of the GEMINI system (se abrirá en una nueva ventana)Identification of gaps in European Codes and Standards for the design of the GEMINI system, M35, FRA-SAS, NNL, NCBJ, JRC, CVR
Publicaciones
Autores:
Katarzyna Kiegiel; Dagmara Chmielewska-Śmietanko; Irena Herdzik-Koniecko; Agnieszka Miśkiewicz; Tomasz Smoliński; Marcin Rogowski; Albert Ntang; Nelson Kiprono Rotich; Krzysztof Madaj; Andrzej G. Chmielewski
Publicado en:
Energies, Edición 18, 2025, ISSN 1996-1073
Editor:
Multidisciplinary Digital Publishing Institute (MDPI)
DOI:
10.3390/EN18030622
Autores:
Canet Serin, Martin Glückler, Michel Pasquet, Claire Vaglio-Gaudard
Publicado en:
EPJ Nuclear Sciences & Technologies, Edición 11, 2025, ISSN 2491-9292
Editor:
EDP Sciences
DOI:
10.1051/EPJN/2025007