Low-dose breast CT with monochromatic x-ray sources

Project description

Monochromatic X-ray source for accurate breast CT imaging

Advancements in breast cancer screening and treatment have reduced mortality rates by 30 %, yet over 600 000 women still die from the disease each year. Improved imaging techniques, such as the dynamic contrast-enhanced breast computed tomography developed by the BREAST4D project, are essential for personalised treatment. A new monochromatic X-ray source overcomes the limitations of traditional X-ray tubes. The ERC-funded MONOBREAST project will enhance BREAST4D’s results by integrating monochromatic X-ray sources with advanced image reconstruction methods for breast CT imaging. This system will reduce radiation doses. Also, it can be applied throughout the breast cancer care continuum – from non-contrast screening, similar to digital mammography, to static contrast-enhanced and 4D dynamic imaging for personalised diagnosis and treatment.

Objective

Although breast cancer screening and improvements in treatment have reduced breast cancer mortality by 30%, this disease still kills over 600,000 women yearly worldwide. To further reduce its morbidity and mortality, new and improved imaging modalities that improve the detection, diagnosis, and treatment of breast cancer are needed.
Over the last two decades, changes in x-ray detector technology have revolutionized x-ray-based breast imaging. Among other developments, new digital detectors made feasible the ERC Consolidator project BREAST4D during which a new imaging modality, dynamic contrast enhanced dedicated breast computed tomography (4D DCE-BCT) is being developed to personalize treatment of breast cancer.
However, x-ray source technology has remained essentially unchanged for the last 100 years. The continued use of the x-ray tube as the source of x rays restricts the reduction in dose and the quantitative accuracy achievable with advances in the rest of the system. Very recently, however, a new monochromatic x-ray source has been developed that provides the necessary flux, x-ray energy, field of view, and portability, to be used in x-ray breast imaging devices.
In MONOBREAST, the capabilities, applicability, and innovativeness of BREAST4D will be extended by introducing these monochromatic x-ray sources to breast CT imaging and combining them with the advanced image reconstruction method developed during BREAST4D. Resulting in a dose reduction of at least two thirds, such a monochromatic breast CT system will be applicable to every stage in the breast cancer chain, from screening with non-contrast BCT at doses equivalent to those of current screening with digital mammography and digital breast tomosynthesis, to static CE-BCT for diagnosis and the originally planned 4D DCE-BCT for treatment personalization. In addition, these new sources will not only result in substantially lower doses, but also in substantially higher accuracy with lower algorithmic complexity.

Fields of science (EuroSciVoc)

Programme(s)

Topic(s)

Funding Scheme

HORIZON-ERC-POC - HORIZON ERC Proof of Concept Grants

See all projects funded under this funding scheme

Call for proposal

(opens in new window) ERC-2022-POC1

See all projects funded under this call

Host institution

STICHTING RADBOUD UNIVERSITAIR MEDISCH CENTRUM
Net EU contribution
€ 150 000,00
Address
GEERT GROOTEPLEIN 10 ZUID
6525 GA Nijmegen
Netherlands
Region
Oost-Nederland Gelderland Arnhem/Nijmegen
Activity type
Higher or Secondary Education Establishments
Links
Total cost
No data

Beneficiaries (1)

Partners (1)