Work Package 1: the Steering Committee met regularly to oversee project progress. A key milestone was the successful organization of the 2nd Annual Consortium Meeting. Regular coordination meetings were held between EVI and UMCG and among WP2–5 leaders. The consortium also implemented an amendment replacing JHU with Mayo Clinic as a beneficiary and coordinated preparations for the 1st Project Review Meeting.
Work Package 2 -Sample preparation and sequencing: Methods for blood and joint fluid were compared and standardised. Blood cultures undergo human-material removal before bacterial DNA extraction; short incubation of joint fluid increases bacterial numbers enough to avoid additional human-DNA removal. Methods detect low bacterial concentrations and include contamination safeguards. Camtech delivered three DRAIGONprep prototypes and initial consumables; the platform was adapted to improved consortium workflows, with online training, validation and technical support. Overnight blood-culture concentration increased bacterial material >10-fold and enabled sequencing within 24 hours. Alternative DNA-removal methods were compared, including a cheaper, less labour-intensive option. OSS is conducting a retrospective proof-of-concept study of 112 periprosthetic synovial-fluid specimens from hip/knee revision patients, combining targeted bacterial/fungal extraction and long-read sequencing for pathogen identification and AMR prediction. Assessment uses the 2021 diagnostic criteria of the European Bone and Joint Infection Society and conventional microbiology; specimen selection, baseline-result review and frozen-pellet preparation are complete.
Work Package 3 – Pathogen profiling and gAST: DRAIGON Predict was released as web and locally installable software, producing genomic antibiograms against European breakpoints and identifying supporting resistance genes/mutations. pLIN classifies and tracks mobile resistance elements without a reference database. In a blinded hospital outbreak involving five species and 55 patients, it correctly identified the shared resistance element. Laboratory evolution experiments were established for model training and calibration.
Work Package 4 – Bloodstream infections: A reliable, standardised sequencing workflow was established. Recurrent failures were resolved through purification and enzymatic-treatment steps, producing reproducible performance across laboratories. DNA extraction/human-DNA removal were validated on routine material; detection limits and acceptance criteria were defined and paired clinical/standard-care data collection prepared. An inter-laboratory ring trial is scheduled for September 2026; prospective patient recruitment is planned afterwards.
Work Package 5 – Prosthetic joint infections: Procedures for joint and bloodstream infections were independently optimised and then harmonised by incorporating three bloodstream-processing steps into the joint procedure, increasing the feasibility of one automated approach for both sample types. An open data-preparation pipeline that feeds the project's prediction software is being developed; in a single automated run it checks the quality of raw data, removes human sequences, reconstructs the bacterial genome and verifies the result. Development continues, and the code is publicly accessible for transparency and reproducibility.
Work Package 6 – Capacity-building: At UHSN, the Oxford Nanopore WGS platform was established and integrated into microbiology with workflows and SOPs. UMCG provided training in laboratory procedures, sequencing, QC, bioinformatics and WGS interpretation. Pilot-study preparations are progressing. Sustainability measures include trained staff, SOPs, consumables/reagent planning and continuity of expertise and technical support, supporting future routine WGS-based AMR diagnostics and surveillance in Albania.
Work Package 7 – Health technology assessment: DRAIGON assesses clinical, organisational, patient and economic value. A survey of staff in the Netherlands, Austria and Albania found positive expectations for faster diagnosis and better decisions; challenges were cost, regulation, staffing and IT, while workflow integration, training and leadership were key enablers. Follow-up interviews have begun.
A living review/meta-analysis of >60 studies found earlier diagnosis associated with lower mortality, substantially faster appropriate antibiotic treatment and a more modest reduction in the length of hospital stay. The evidence is available via an interactive dashboard and has been updated.
A qualitative study is being prepared on patients’/caregivers’ information needs, concerns and acceptance of AI-guided diagnostics; ethics and recruitment arrangements are underway, with some procedural delays.
An economic simulation compares current bloodstream-infection care with DRAIGON, following patients through testing, treatment and outcomes. It will be refined with clinical data and expanded to other infections/countries. Initial sections of the overarching HTA report are being drafted.
Work Package 8 – Regulatory path to market: DRAIGON established its quality/regulatory foundation. The project quality system covers document control, training/competence, audits, deviations and management review. A product-level ISO 13485 system is being implemented, while IVDR requirements and the regulatory roadmap are being defined with the technology partner. The consortium will keep the prediction model proprietary while releasing the surrounding analysis pipeline openly for transparency and reproducibility.