Clocking the conduction velocity of the visual pathway with optically pumped magnetometers

Project description

Revolutionising visual pathway diagnostics

Neural signals travel from the retina – the light-sensitive tissue at the back of the eye – to the visual cortex of the brain where the visual information is processed. The speed at which this information is transmitted along the visual pathway could offer insights into neurodegeneration and potential diagnostic markers for conditions affecting the visual system. Funded by the European Research Council, the OptiVision project aims to create a diagnostic tool for measuring this retinocortical conduction time. The technology is based on optically pumped magnetometers and is intended to diagnose conditions before visible symptoms emerge by detecting disruptions in myelination, circulation and neural connectivity with enhanced accuracy and sensitivity.

Objective

The human visual pathway carries high volumes of information from the retina to distant regions of visual cortex. The speed of this information transfer, retinocortical conduction time, has been proposed as a diagnostic measure of neurodegeneration. This conduction time has typically been estimated based on relatively slow evoked responses, although we now know that high-frequency activity in both the retina and visual cortex precede slower evoked responses by several tens of milliseconds. In addition, the difference in timing between the onset of high-frequency activity in the retina and cortex is more in line with the expected conduction velocities of the heavily myelinated visual pathway.

This project proposes to develop and validate a new sensor technology, optically pumped magnetometers (OPMs), to measure this high-frequency retinocortical conduction time, with a view towards establishing a diagnostic suitable for patients in the neurology and eye clinics to assess disease progression. Impacts to myelination, circulation, and neural connectivity are all expected to reduce the conduction speed of the visual pathway, even before visual symptoms become apparent. The proposed high-frequency conduction time technique should provide a more accurate and sensitive measure to detect these impacts, with high potential for translation into a clinical diagnostic method. We will furthermore streamline the measurement procedure to increase the comfort, duration, and feasibility for potential patient groups.

Fields of science (EuroSciVoc)

Programme(s)

Topic(s)

Funding Scheme

HORIZON-ERC-POC - HORIZON ERC Proof of Concept Grants

See all projects funded under this funding scheme

Call for proposal

(opens in new window) ERC-2023-POC

See all projects funded under this call

Host institution

AARHUS UNIVERSITET
Net EU contribution
€ 150 000,00
Address
NORDRE RINGGADE 1
8000 Aarhus C
Denmark
Region
Danmark Midtjylland Østjylland
Activity type
Higher or Secondary Education Establishments
Links
Total cost
No data

Beneficiaries (1)