European Commission logo
français français
CORDIS - Résultats de la recherche de l’UE
CORDIS

Continuous Regional Analysis Device for neonate Lung

Livrables

Publications

Clinical performance of a novel textile interface for neonatal chest electrical impedance tomography

Auteurs: L Sophocleous, I Frerichs, M Miedema, M Kallio, T Papadouri, C Karaoli, T Becher, D G Tingay, A H van Kaam, R Bayford, A D Waldmann
Publié dans: Physiological Measurement, Numéro 39/4, 2018, Page(s) 044004, ISSN 1361-6579
Éditeur: Institute of Physics and Engineering in Medicine
DOI: 10.1088/1361-6579/aab513

A High Frame Rate Wearable EIT System Using Active Electrode ASICs for Lung Respiration and Heart Rate Monitoring

Auteurs: Yu Wu, Dai Jiang, Andy Bardill, Serena de Gelidi, Richard Bayford, Andreas Demosthenous
Publié dans: IEEE Transactions on Circuits and Systems I: Regular Papers, Numéro 65/11, 2018, Page(s) 3810-3820, ISSN 1549-8328
Éditeur: Institute of Electrical and Electronics Engineers
DOI: 10.1109/tcsi.2018.2858148

Optimized breath detection algorithm in electrical impedance tomography

Auteurs: D Khodadad, S Nordebo, B Müller, A Waldmann, R Yerworth, T Becher, I Frerichs, L Sophocleous, A van Kaam, M Miedema, N Seifnaraghi, R Bayford
Publié dans: Physiological Measurement, Numéro 39/9, 2018, Page(s) 094001, ISSN 1361-6579
Éditeur: IoPP Institute of Physics Publishing
DOI: 10.1088/1361-6579/aad7e6

A parametric model for the changes in the complex valued conductivity of a lung during tidal breathing

Auteurs: Sven Nordebo, Mariana Dalarsson, Davood Khodadad, Beat Müller, Andreas D Waldmann, Tobias Becher, Inez Frerichs, Louiza Sophocleous, Daniel Sjöberg, Nima Seifnaraghi, Richard Bayford
Publié dans: Journal of Physics D: Applied Physics, Numéro 51/20, 2018, Page(s) 205401, ISSN 0022-3727
Éditeur: Institute of Physics Publishing
DOI: 10.1088/1361-6463/aabc04

Electrical Impedance Tomography Can Identify Ventilation and Perfusion Defects: A Neonatal Case

Auteurs: David G. Tingay, Andreas D. Waldmann, Inéz Frerichs, Sarath Ranganathan, Andy Adler
Publié dans: American Journal of Respiratory and Critical Care Medicine, Numéro 199/3, 2019, Page(s) 384-386, ISSN 1073-449X
Éditeur: American Thoracic Society
DOI: 10.1164/rccm.201808-1551le

Chest electrical impedance tomography measures in neonatology and paediatrics – a survey on clinical usefulness

Auteurs: Inez Frerichs, Tobias Becher
Publié dans: Physiological Measurement, 2019, ISSN 0967-3334
Éditeur: Institute of Physics Publishing
DOI: 10.1088/1361-6579/ab1946

Chest electrical impedance tomography examination, data analysis, terminology, clinical use and recommendations: consensus statement of the TRanslational EIT developmeNt stuDy group

Auteurs: Inéz Frerichs, Marcelo B P Amato, Anton H van Kaam, David G Tingay, Zhanqi Zhao, Bartłomiej Grychtol, Marc Bodenstein, Hervé Gagnon, Stephan H Böhm, Eckhard Teschner, Ola Stenqvist, Tommaso Mauri, Vinicius Torsani, Luigi Camporota, Andreas Schibler, Gerhard K Wolf, Diederik Gommers, Steffen Leonhardt, Andy Adler
Publié dans: Thorax, Numéro 72/1, 2016, Page(s) 83-93, ISSN 0040-6376
Éditeur: BMJ Publishing Group
DOI: 10.1136/thoraxjnl-2016-208357

Torso shape detection to improve lung monitoring

Auteurs: S de Gelidi, N Seifnaraghi, A Bardill, A Tizzard, Y Wu, E Sorantin, S Nordebo, A Demosthenous, R Bayford
Publié dans: Physiological Measurement, Numéro 39/7, 2018, Page(s) 074001, ISSN 1361-6579
Éditeur: IoP Publishing
DOI: 10.1088/1361-6579/aacc1c

Compressive sensing in electrical impedance tomography for breathing monitoring

Auteurs: A Shiraz, D Khodadad, S Nordebo, R Yerworth, I Frerichs, A van Kaam, M Kallio, T Papadouri, R Bayford, A Demosthenous
Publié dans: Physiological Measurement, Numéro 40/3, 2019, Page(s) 034010, ISSN 1361-6579
Éditeur: IoP
DOI: 10.1088/1361-6579/ab0daa

Early Recognition of Pneumothorax in Neonatal RDS with Electrical Impedance Tomography

Auteurs: Marika Rahtu, Inéz Frerichs, Andreas D Waldmann, Claas Strodthoff, Tobias Becher, Richard Bayford, Merja Kallio
Publié dans: American Journal of Respiratory and Critical Care Medicine, 2019, ISSN 1073-449X
Éditeur: American Thoracic Society
DOI: 10.1164/rccm.201810-1999im

Changes in ventilation distribution from pressure controlled ventilation to neutrally adjusted ventilator assist

Auteurs: Marika Rahtu, Andreas D Waldmann, Esa Rahtu, Tobias Becher, Inéz Frerichs, Richard Bayford, Merja Kallio
Publié dans: 2018
Éditeur: EPNV 2018

Design of a CMOS active electrode IC for wearable electrical impedance tomography systems

Auteurs: Yu Wu, Peter Langlois, Richard Bayford, Andreas Demosthenous
Publié dans: 2016 IEEE International Symposium on Circuits and Systems (ISCAS), 2016, Page(s) 846-849, ISBN 978-1-4799-5341-7
Éditeur: IEEE
DOI: 10.1109/iscas.2016.7527373

A novel active electrode IC for wearable EIT system

Auteurs: Y. Wu, P. Langlois, R. Bayford and A. Demosthenous
Publié dans: 2016
Éditeur: Conference Organisation
DOI: 10.5281/zenodo.55753

Live demonstration: A wearable EIT system using active electrodes for monitoring respiration

Auteurs: Yu Wu, Dai Jiang, Andy Bardill, Serena De Gelidi, Richard Bayford, Andreas Demosthenous
Publié dans: 2017 IEEE International Symposium on Circuits and Systems (ISCAS), 2017, Page(s) 1-1, ISBN 978-1-4673-6853-7
Éditeur: IEEE
DOI: 10.1109/iscas.2017.8050713

A CMOS current driver with built-in common-mode signal reduction capability for EIT

Auteurs: Yu Wu, Dai Jiang, Peter Langlois, Richard Bayford, Andreas Demosthenous
Publié dans: ESSCIRC 2017 - 43rd IEEE European Solid State Circuits Conference, 2017, Page(s) 227-230, ISBN 978-1-5090-5025-3
Éditeur: IEEE
DOI: 10.1109/esscirc.2017.8094567

Graphical user interface for patient data overview of long and continuous EIT monitoring for research analysis

Auteurs: A. Dupré, M-R. Benissa, B. Müller, A. D. Waldmann, R. Yerworth, T. Becher, M. Miedema, S. Nordebo, D. Khodadad, I. Frerichs, R. Bayford, P. C. Rimensberger
Publié dans: 2019
Éditeur: International Conference on Biomedical Applications of Electrical Impedance Tomography

The Value of Phase Angle in Electrical Impedance Tomography Breath Detection

Auteurs: Davood Khodadad, Sven Nordebo, Nima Seifnaraghi, Rebecca Yerworth, Andreas D. Waldmann, Beat Muller, Inez Frerichs, Anton van Kaam, Martijn Miedema, Richard Bayford
Publié dans: 2018 Progress in Electromagnetics Research Symposium (PIERS-Toyama), 2018, Page(s) 1040-1043, ISBN 978-4-8855-2316-8
Éditeur: IEEE
DOI: 10.23919/piers.2018.8597702

Breath detection using short-time Fourier transform analysis in electrical impedance tomography

Auteurs: Davood Khodadad, Sven Nordebo, Nima Seifnaraghi, Andreas D. Waldmann, Beat Muller, Richard Bayford
Publié dans: 2017 XXXIInd General Assembly and Scientific Symposium of the International Union of Radio Science (URSI GASS), 2017, Page(s) 1-3, ISBN 978-90-825987-0-4
Éditeur: IEEE
DOI: 10.23919/ursigass.2017.8105231

Effect of suctioning on chest EIT findings in neonates: preliminary results of a multicentre clinical study

Auteurs: C Strodthoff
Publié dans: 2018
Éditeur: Edinburgh University

Clinical acceptance of various EIT parameters in neonatology and paediatrics: A systematic assessment of clinicians´ opinions

Auteurs: Tobias Becher and Inéz Frerichs
Publié dans: 2018
Éditeur: Edinburgh University
DOI: 10.5281/zenodo.1210247

Electrical impedance tomography: The past, the present and the future.

Auteurs: Inez Frerichs
Publié dans: 2019
Éditeur: Japanese Society of Intensive Care Medicine

Electrical impedance tomography for monitoring regional lung ventilation in critically ill patients.

Auteurs: Inez Frerichs
Publié dans: 2019
Éditeur: Japanese Society of Intensive Care Medicine

Estimation of Thorax Shape for Forward Modelling in Lungs EIT

Auteurs: Nima Seifnaraghi ,Andrew Tizzard, Serena de Gelidi, Davood Khodadad, Sven Nordebo, Anton Van Kaam, Inez Frerichs, Andreas Waldmann, Erich Sorantin, Sebastian Tschauner, Andreas Demosthenous, Stelios Christofides, Richard Bayford
Publié dans: 2017
Éditeur: Thayer School of Engineering at Dartmouth

Towards a thoracic conductive phantom for EIT

Auteurs: Serena de Gelidi, Andy Bardill, Nima Seifnaraghi, Yu Wu, Inéz Frerichs, Andreas Demosthenous, Andrew Tizzard, Richard Bayford
Publié dans: 2018
Éditeur: Edinburgh University

Effect of Thorax Deformation during Neonatal Lung EIT

Auteurs: Nima Seifnaraghi, Andrew Tizzard, Serena de Gelidi, Davood Khodadad, Sven Nordebo, Anton van Kaam, Inéz Frerichs, Andreas Waldmann, Erich Sorantin, Sebastian Tschauner, Andreas Demosthenous, Richard Bayford
Publié dans: 2018
Éditeur: The University of Edinburgh

Torso shape detection to improve lung monitoring

Auteurs: Serena de Gelidi, Andy Bardill, Yu Wu, Andreas Demosthenous, Andrew Tizzard, Richard Bayford
Publié dans: 2017
Éditeur: University College London, Middlesex University

Live Demonstration: A Wearable EIT System Using Active Electrodes for Monitoring Respiration

Auteurs: Yu Wu, Dai Jiang, Andy Bardill, Serena De Gelidi, Richard Bayford, Andreas Demosthenous
Publié dans: 2017
Éditeur: Middlesex University, University College London
DOI: 10.5281/zenodo.557093

Breath detection using short-time Fourier transform analysis in Electrical Impedance Tomography

Auteurs: D. Khodadad, S. Nordebo, N. Seifnaraghi, A. Waldmann, B. Muller, R. Bayford
Publié dans: 32nd URSI General Assembly & Scientific Symposium, 2017, Page(s) 2185-2187
Éditeur: URSI

DICOM for EIT presentation at the 18th International Conference on Biomedical Applications of Electrical Impedance Tomography

Auteurs: Yerworth RJ, Bayford R
Publié dans: 2017
Éditeur: Thayer School of Engineering

Continuous Regional Analysis Device for Neonatal Lung (CRADL)

Auteurs: Richard Bayford, Andrew Tizzard, Inéz Frerichs, Norbert Weiler, Christina Karaoli, Stelios Christofides, Charalambos Yiannakkaras, Peter Rimensberger, Sven Nordebo, Stephan H. Böhm, Anton van Kaam, Bruce Fifield, Christopher Knox, Lotte Steuten, Gimon de Graaf, Rebecca Yerworth, Micheal Butterworth, Andreas Demosthenous
Publié dans: 2016, Page(s) 172-172
Éditeur: Springer International Publishing Springer
DOI: 10.1007/978-3-319-32703-7_35

Recherche de données OpenAIRE...

Une erreur s’est produite lors de la recherche de données OpenAIRE