Skip to main content

Continuous Regional Analysis Device for neonate Lung

Deliverables

Clinical users trained in the application of current Swisscom clinical system and the pediatric version containing improvements made by the project.

Clinical users trained in the application of current Swisscom clinical system and the pediatric version containing improvements made by the project.

Website creation

Initial website will be set up within the second month of the project. This will be reviewed every 2 months and updated accordingly.

Contributions to EIT and EIDORS websites

Contributions to EIT and EIDORS websites

Validation of ability of EIT monitoring to detect adverse pulmonary effects associated with high ventilation heterogeneity

Validation of ability of EIT monitoring to detect adverse pulmonary effects associated with high ventilation heterogeneity

Increased user base of this technology

Increased user base of this technology

Optimised interface design for clinical users

Optimised interface design for clinical users

Searching for OpenAIRE data...

Publications

Clinical performance of a novel textile interface for neonatal chest electrical impedance tomography

Author(s): L Sophocleous, I Frerichs, M Miedema, M Kallio, T Papadouri, C Karaoli, T Becher, D G Tingay, A H van Kaam, R Bayford, A D Waldmann
Published in: Physiological Measurement, Issue 39/4, 2018, Page(s) 044004, ISSN 1361-6579
DOI: 10.1088/1361-6579/aab513

A High Frame Rate Wearable EIT System Using Active Electrode ASICs for Lung Respiration and Heart Rate Monitoring

Author(s): Yu Wu, Dai Jiang, Andy Bardill, Serena de Gelidi, Richard Bayford, Andreas Demosthenous
Published in: IEEE Transactions on Circuits and Systems I: Regular Papers, Issue 65/11, 2018, Page(s) 3810-3820, ISSN 1549-8328
DOI: 10.1109/tcsi.2018.2858148

Optimized breath detection algorithm in electrical impedance tomography

Author(s): D Khodadad, S Nordebo, B Müller, A Waldmann, R Yerworth, T Becher, I Frerichs, L Sophocleous, A van Kaam, M Miedema, N Seifnaraghi, R Bayford
Published in: Physiological Measurement, Issue 39/9, 2018, Page(s) 094001, ISSN 1361-6579
DOI: 10.1088/1361-6579/aad7e6

A parametric model for the changes in the complex valued conductivity of a lung during tidal breathing

Author(s): Sven Nordebo, Mariana Dalarsson, Davood Khodadad, Beat Müller, Andreas D Waldmann, Tobias Becher, Inez Frerichs, Louiza Sophocleous, Daniel Sjöberg, Nima Seifnaraghi, Richard Bayford
Published in: Journal of Physics D: Applied Physics, Issue 51/20, 2018, Page(s) 205401, ISSN 0022-3727
DOI: 10.1088/1361-6463/aabc04

Electrical Impedance Tomography Can Identify Ventilation and Perfusion Defects: A Neonatal Case

Author(s): David G. Tingay, Andreas D. Waldmann, Inéz Frerichs, Sarath Ranganathan, Andy Adler
Published in: American Journal of Respiratory and Critical Care Medicine, Issue 199/3, 2019, Page(s) 384-386, ISSN 1073-449X
DOI: 10.1164/rccm.201808-1551le

Chest electrical impedance tomography measures in neonatology and paediatrics – a survey on clinical usefulness

Author(s): Inez Frerichs, Tobias Becher
Published in: Physiological Measurement, 2019, ISSN 0967-3334
DOI: 10.1088/1361-6579/ab1946

Chest electrical impedance tomography examination, data analysis, terminology, clinical use and recommendations: consensus statement of the TRanslational EIT developmeNt stuDy group

Author(s): Inéz Frerichs, Marcelo B P Amato, Anton H van Kaam, David G Tingay, Zhanqi Zhao, Bartłomiej Grychtol, Marc Bodenstein, Hervé Gagnon, Stephan H Böhm, Eckhard Teschner, Ola Stenqvist, Tommaso Mauri, Vinicius Torsani, Luigi Camporota, Andreas Schibler, Gerhard K Wolf, Diederik Gommers, Steffen Leonhardt, Andy Adler
Published in: Thorax, Issue 72/1, 2016, Page(s) 83-93, ISSN 0040-6376
DOI: 10.1136/thoraxjnl-2016-208357

Torso shape detection to improve lung monitoring

Author(s): S de Gelidi, N Seifnaraghi, A Bardill, A Tizzard, Y Wu, E Sorantin, S Nordebo, A Demosthenous, R Bayford
Published in: Physiological Measurement, Issue 39/7, 2018, Page(s) 074001, ISSN 1361-6579
DOI: 10.1088/1361-6579/aacc1c

Compressive sensing in electrical impedance tomography for breathing monitoring

Author(s): A Shiraz, D Khodadad, S Nordebo, R Yerworth, I Frerichs, A van Kaam, M Kallio, T Papadouri, R Bayford, A Demosthenous
Published in: Physiological Measurement, Issue 40/3, 2019, Page(s) 034010, ISSN 1361-6579
DOI: 10.1088/1361-6579/ab0daa

Early Recognition of Pneumothorax in Neonatal RDS with Electrical Impedance Tomography

Author(s): Marika Rahtu, Inéz Frerichs, Andreas D Waldmann, Claas Strodthoff, Tobias Becher, Richard Bayford, Merja Kallio
Published in: American Journal of Respiratory and Critical Care Medicine, 2019, ISSN 1073-449X
DOI: 10.1164/rccm.201810-1999im

Changes in ventilation distribution from pressure controlled ventilation to neutrally adjusted ventilator assist

Author(s): Marika Rahtu, Andreas D Waldmann, Esa Rahtu, Tobias Becher, Inéz Frerichs, Richard Bayford, Merja Kallio
Published in: 2018

Design of a CMOS active electrode IC for wearable electrical impedance tomography systems

Author(s): Yu Wu, Peter Langlois, Richard Bayford, Andreas Demosthenous
Published in: 2016 IEEE International Symposium on Circuits and Systems (ISCAS), 2016, Page(s) 846-849
DOI: 10.1109/iscas.2016.7527373

A novel active electrode IC for wearable EIT system

Author(s): Y. Wu, P. Langlois, R. Bayford and A. Demosthenous
Published in: 2016
DOI: 10.5281/zenodo.55753

Live demonstration: A wearable EIT system using active electrodes for monitoring respiration

Author(s): Yu Wu, Dai Jiang, Andy Bardill, Serena De Gelidi, Richard Bayford, Andreas Demosthenous
Published in: 2017 IEEE International Symposium on Circuits and Systems (ISCAS), 2017, Page(s) 1-1
DOI: 10.1109/iscas.2017.8050713

A CMOS current driver with built-in common-mode signal reduction capability for EIT

Author(s): Yu Wu, Dai Jiang, Peter Langlois, Richard Bayford, Andreas Demosthenous
Published in: ESSCIRC 2017 - 43rd IEEE European Solid State Circuits Conference, 2017, Page(s) 227-230
DOI: 10.1109/esscirc.2017.8094567

Graphical user interface for patient data overview of long and continuous EIT monitoring for research analysis

Author(s): A. Dupré, M-R. Benissa, B. Müller, A. D. Waldmann, R. Yerworth, T. Becher, M. Miedema, S. Nordebo, D. Khodadad, I. Frerichs, R. Bayford, P. C. Rimensberger
Published in: 2019

The Value of Phase Angle in Electrical Impedance Tomography Breath Detection

Author(s): Davood Khodadad, Sven Nordebo, Nima Seifnaraghi, Rebecca Yerworth, Andreas D. Waldmann, Beat Muller, Inez Frerichs, Anton van Kaam, Martijn Miedema, Richard Bayford
Published in: 2018 Progress in Electromagnetics Research Symposium (PIERS-Toyama), 2018, Page(s) 1040-1043
DOI: 10.23919/piers.2018.8597702

Breath detection using short-time Fourier transform analysis in electrical impedance tomography

Author(s): Davood Khodadad, Sven Nordebo, Nima Seifnaraghi, Andreas D. Waldmann, Beat Muller, Richard Bayford
Published in: 2017 XXXIInd General Assembly and Scientific Symposium of the International Union of Radio Science (URSI GASS), 2017, Page(s) 1-3
DOI: 10.23919/ursigass.2017.8105231

Effect of suctioning on chest EIT findings in neonates: preliminary results of a multicentre clinical study

Author(s): C Strodthoff
Published in: 2018

Clinical acceptance of various EIT parameters in neonatology and paediatrics: A systematic assessment of clinicians´ opinions

Author(s): Tobias Becher and Inéz Frerichs
Published in: 2018
DOI: 10.5281/zenodo.1210247

Electrical impedance tomography: The past, the present and the future.

Author(s): Inez Frerichs
Published in: 2019

Electrical impedance tomography for monitoring regional lung ventilation in critically ill patients.

Author(s): Inez Frerichs
Published in: 2019

Estimation of Thorax Shape for Forward Modelling in Lungs EIT

Author(s): Nima Seifnaraghi ,Andrew Tizzard, Serena de Gelidi, Davood Khodadad, Sven Nordebo, Anton Van Kaam, Inez Frerichs, Andreas Waldmann, Erich Sorantin, Sebastian Tschauner, Andreas Demosthenous, Stelios Christofides, Richard Bayford
Published in: 2017

Towards a thoracic conductive phantom for EIT

Author(s): Serena de Gelidi, Andy Bardill, Nima Seifnaraghi, Yu Wu, Inéz Frerichs, Andreas Demosthenous, Andrew Tizzard, Richard Bayford
Published in: 2018

Effect of Thorax Deformation during Neonatal Lung EIT

Author(s): Nima Seifnaraghi, Andrew Tizzard, Serena de Gelidi, Davood Khodadad, Sven Nordebo, Anton van Kaam, Inéz Frerichs, Andreas Waldmann, Erich Sorantin, Sebastian Tschauner, Andreas Demosthenous, Richard Bayford
Published in: 2018

Torso shape detection to improve lung monitoring

Author(s): Serena de Gelidi, Andy Bardill, Yu Wu, Andreas Demosthenous, Andrew Tizzard, Richard Bayford
Published in: 2017

Live Demonstration: A Wearable EIT System Using Active Electrodes for Monitoring Respiration

Author(s): Yu Wu, Dai Jiang, Andy Bardill, Serena De Gelidi, Richard Bayford, Andreas Demosthenous
Published in: 2017
DOI: 10.5281/zenodo.557093

Breath detection using short-time Fourier transform analysis in Electrical Impedance Tomography




DICOM for EIT presentation at the 18th International Conference on Biomedical Applications of Electrical Impedance Tomography

Author(s): Yerworth RJ, Bayford R
Published in: 2017

Continuous Regional Analysis Device for Neonatal Lung (CRADL)

Author(s): Richard Bayford, Andrew Tizzard, Inéz Frerichs, Norbert Weiler, Christina Karaoli, Stelios Christofides, Charalambos Yiannakkaras, Peter Rimensberger, Sven Nordebo, Stephan H. Böhm, Anton van Kaam, Bruce Fifield, Christopher Knox, Lotte Steuten, Gimon de Graaf, Rebecca Yerworth, Micheal Butterworth, Andreas Demosthenous
Published in: 2016, Page(s) 172-172
DOI: 10.1007/978-3-319-32703-7_35