Skip to main content

Portable Nano-Particle Emission Measurement System

Deliverables

Calibrated CPC with D50 ≤ 10 nm for PEMS use

Report describing calibrated CPC with D50 ≤ 10 nm for PEMS use – together with the documented calibration procedure . A demonstrator will be developed as well.

Implementation of a calibration procedure

Report describing the implementation of a calibration procedure.

Calibrated PEMS particle counting system and calibration procedure

Report on calibrated solid particle counting system for PEMS use – together with the documented calibration procedure. A demonstrator will be developed as well (DEM).

Calibrated laboratory particle counting system and calibration procedure

Report describing calibrated solid particle counting system for laboratory use – together with the documented calibration procedure.A demonstrator will be developed as well.

Calibrated CPC with D50 ≤ 10 nm for laboratory use

Report describing Calibrated CPC with D50 ≤ 10 nm for laboratory use – together with the documented calibration procedure. A demonstrator will be delivered as well (DEM)

Project website

Report describing the project website, including Project templates (reports, presentations, logo), database for Dissemination (stakeholders, interest groups, contact details)

Parametric and sensitivity studies

Report on parametric and sensitivity studies (OTHER)

Report on particle losses in the instruments

Report about particle losses related to the measurement instruments and the different sampling locations

Measurement procedure of the equipment

Report describing the measurement procedure of the equipment.

Report on criteria for project internal impact assessment

Report describing criteria for project internal impact assessment

Searching for OpenAIRE data...

Publications

Modelling particle mass and particle number emissions during the active regeneration of diesel particulate filters

Author(s): Chung Ting Lao, Jethro Akroyd, Nickolas Eaves, Alastair Smith, Neal Morgan, Amit Bhave, Markus Kraft
Published in: Proceedings of the Combustion Institute, Issue 37/4, 2019, Page(s) 4831-4838, ISSN 1540-7489
DOI: 10.1016/j.proci.2018.07.079

On the benefits of using multivariate analysis in mass spectrometric studies of combustion-generated aerosols

Author(s): D. Duca, C. Irimiea, A. Faccinetto, J. A. Noble, M. Vojkovic, Y. Carpentier, I. K. Ortega, C. Pirim, C. Focsa
Published in: Faraday Discussions, Issue 218, 2019, Page(s) 115-137, ISSN 1359-6640
DOI: 10.1039/C8FD00238J

Unveiling trends in soot nucleation and growth: When secondary ion mass spectrometry meets statistical analysis

Author(s): Cornelia Irimiea, Alessandro Faccinetto, Xavier Mercier, Ismael-Kenneth Ortega, Nicolas Nuns, Eric Therssen, Pascale Desgroux, Cristian Focsa
Published in: Carbon, Issue 144, 2019, Page(s) 815-830, ISSN 0008-6223
DOI: 10.1016/j.carbon.2018.12.015

A new methodology to calculate process rates in a kinetic Monte Carlo model of PAH growth

Author(s): Gustavo Leon, Nick Eaves, Jethro Akroyd, Sebastian Mosbach, Markus Kraft
Published in: Combustion and Flame, Issue 209, 2019, Page(s) 133-143, ISSN 0010-2180
DOI: 10.1016/j.combustflame.2019.07.032