European Commission logo
français français
CORDIS - Résultats de la recherche de l’UE
CORDIS

A miniature Bio-photonics Companion Diagnostics platform for reliable cancer diagnosis and treatment monitoring.

Livrables

Data managment plan

BIOCDx has decided to participate in the Open Research Data Pilot, introduced in Horizon 2020 Work Programme. In line with this decision, this deliverable will provide the Data Managment Plan (DMP) that will be defined in the first 6 months of the project in the framework of WP8. The Data Management Plan deals with all the concerns about the treatment of the data that will be involved in the whole project lifecycle and will be structured in compliance with the guidelines and the template conveyed by the European Commission.The main aspects that will be considered in the Data Management Plan, for each of the data set identified in the project are: types of data generated, collected or processed,standards used to manage data,data exploitation methodology, accessibility to data produced by the Project,data dissemination level, data Preservation and re-use. [ICCS/NTUA, All]

Report on the dissemination and outreach activities

Within this deliverable the dissemination activities of the project’s generated knowledge will be implemented including outreach activities to the public. [ICCS/NTUA, All]

Publications

Photonic Integrated Circuit based sensing modules with hybrid integration in the silicon nitride TriPleX™ platform

Auteurs: Arne Leinse, Douwe Geuzebroek
Publié dans: Optical Fiber Communication Conference (OFC) 2019, 2019, Page(s) Tu2D.4, ISBN 978-1-943580-53-8
Éditeur: OSA
DOI: 10.1364/ofc.2019.tu2d.4

Silicon-nitride biophotonic sensing platform

Auteurs: Douwe H. Geuzebroek, Geert Besselink, Erik Schreuder, Floris Falke, Arne Leinse, René Heideman
Publié dans: Integrated Optics: Devices, Materials, and Technologies XXIII, 2019, Page(s) 42, ISBN 9781510624856
Éditeur: SPIE
DOI: 10.1117/12.2507854

Microring resonator biosensing platform for sensitive detection of thrombin

Auteurs: Geert A. J. Besselink, Douwe H. Geuzebroek, Frederik Schreuder, Floris Falke, Arne Leinse, René G. Heideman
Publié dans: 2019
Éditeur: OSA Publishing

Design of ultra-compact multimode interference (MMI) couplers and high efficiency grating couplers in TriPleX platform as part of a photonic based sensor

Auteurs: Lefteris Gounaridis, Panos Groumas, Erik Schreuder, Christos Tsokos, Elias Mylonas, Adam Raptakis, René Heideman, Hercules Avramopoulos, Christos Kouloumentas
Publié dans: Integrated Optics: Devices, Materials, and Technologies XXIII, 2019, Page(s) 79, ISBN 9781510624856
Éditeur: SPIE
DOI: 10.1117/12.2510053

Ultra-sensitive photonic integrated circuit-based biosensors for healthcare applications

Auteurs: René Heideman, Arne Leinse, Douwe Geuzebroek, Erik Schreuder, Floris H. Falke, Ioanna Zergioti, Adriaan van der Meer, Anke Schuetz-Trilling, Luc Scheres, Rachel Vestering-Stenger
Publié dans: Integrated Optics: Devices, Materials, and Technologies XXIV, 2020, Page(s) 24, ISBN 9781510633308
Éditeur: SPIE
DOI: 10.1117/12.2551879

Apta- and Immuno-Sensors Performance Optimization: A Comparative Study of Surface Functionalization Techniques

Auteurs: George Tsekenis, Valentina Vanikioti, Konstantinos Kordatos, Ioanna Zergioti
Publié dans: Proceedings, Numéro 2/13, 2018, Page(s) 847, ISSN 2504-3900
Éditeur: mdpi
DOI: 10.3390/proceedings2130847

Comparative Assessment of Affinity-Based Techniques for Oriented Antibody Immobilization towards Immunosensor Performance Optimization

Auteurs: George Tsekenis, Marianneza Chatzipetrou, Maria Massaouti, Ioanna Zergioti
Publié dans: Journal of Sensors, Numéro 2019, 2019, Page(s) 1-10, ISSN 1687-725X
Éditeur: Hindawi Publishing Corporation
DOI: 10.1155/2019/6754398

Notch controls urothelial integrity in the mouse bladder

Auteurs: Varvara Paraskevopoulou, Vangelis Bonis, Vasilis S. Dionellis, Nikolaos Paschalidis, Pelagia Melissa, Evangelia Chavdoula, Eleni Vasilaki, Ioannis S. Pateras, Apostolos Klinakis
Publié dans: JCI Insight, Numéro 5/3, 2020, ISSN 2379-3708
Éditeur: The Journal of Clinical Investigation
DOI: 10.1172/jci.insight.133232

Analysis Cartridge for Companion Diagnostics

Auteurs: S. F. Graf, T. Volden, S. Berchtold, J. Goldowsky, N. Schmid, V. Revol, H. F. Knapp
Publié dans: CSEM Scientific and Technical Report, Numéro 2017, yearly, 2017, Page(s) 60
Éditeur: CSEM SA

Droits de propriété intellectuelle

Dual beam laser transfer

Numéro de demande/publication: US 2019129349A1
Date: 2017-12-28

Recherche de données OpenAIRE...

Une erreur s’est produite lors de la recherche de données OpenAIRE